[{"data":1,"prerenderedAt":16155},["ShallowReactive",2],{"blog-teaser-fr":3},[4,523,923,1249,1577,2248,2594,2780,3056,3612,4296,4832,5097,5533,5806,6765,7451,7855,8774,9675,10906,11750,12043,12340,12532,12821,13248,13508,13751,13967,14351,14591,14767,15066,15337,15809],{"id":5,"title":6,"articleId":7,"body":8,"category":504,"date":505,"description":506,"extension":507,"lastUpdated":505,"locale":508,"meta":509,"navigation":510,"path":511,"publishDate":505,"readTime":512,"refreshInterval":497,"seo":513,"slug":514,"stem":515,"tags":516,"__hash__":522},"blog\u002Fblog\u002Falternative-trikker.fr.md","PlanElec comme alternative à Trikker : un comparatif (2026)","planelec-vs-trikker",{"type":9,"value":10,"toc":486},"minimark",[11,15,19,22,27,255,275,279,282,288,294,300,306,310,313,319,325,328,331,335,338,344,350,356,362,366,371,374,378,385,389,392,396,399,403,409,415,421,427,433,439,443,471,475],[12,13,6],"h1",{"id":14},"planelec-comme-alternative-à-trikker-un-comparatif-2026",[16,17,18],"p",{},"PlanElec est une alternative à Trikker fonctionnant dans le navigateur, pour établir schémas unifilaires et plans de situation d'installations belges. Trikker fonctionne sous Windows et coûte 45 € par mois HTVA. PlanElec fonctionne dans tout navigateur et est actuellement gratuit pendant l'Early Access. Qui travaille entièrement hors ligne reste mieux servi par Trikker.",[16,20,21],{},"Ce comparatif est rédigé par l'équipe de PlanElec. Les données relatives à Trikker proviennent de leur propre site, avec la source et la date de vérification, afin que vous puissiez contrôler chaque point vous-même.",[23,24,26],"h2",{"id":25},"comparatif-en-un-coup-dœil","Comparatif en un coup d'œil",[28,29,30,46],"table",{},[31,32,33],"thead",{},[34,35,36,40,43],"tr",{},[37,38,39],"th",{},"Critère",[37,41,42],{},"PlanElec",[37,44,45],{},"Trikker",[47,48,49,63,76,89,102,115,128,141,153,164,177,190,203,216,229,242],"tbody",{},[34,50,51,58,60],{},[52,53,54],"td",{},[55,56,57],"strong",{},"Éditeur",[52,59,42],{},[52,61,62],{},"Bluebits BV",[34,64,65,70,73],{},[52,66,67],{},[55,68,69],{},"Plateforme",[52,71,72],{},"Navigateur — Windows, macOS, Linux, iPad",[52,74,75],{},"Windows ; macOS annoncé pour la fin de l'été 2026, version web ensuite",[34,77,78,83,86],{},[52,79,80],{},[55,81,82],{},"Installation",[52,84,85],{},"Aucune",[52,87,88],{},"Installation puis activation via serveur de licences",[34,90,91,96,99],{},[52,92,93],{},[55,94,95],{},"Plusieurs appareils",[52,97,98],{},"Oui, avec le même compte",[52,100,101],{},"Une licence vaut pour un PC à la fois",[34,103,104,109,112],{},[52,105,106],{},[55,107,108],{},"Langues",[52,110,111],{},"Néerlandais, français, allemand, anglais",[52,113,114],{},"Néerlandais, français, anglais",[34,116,117,122,125],{},[52,118,119],{},[55,120,121],{},"Prix",[52,123,124],{},"Early Access, actuellement gratuit",[52,126,127],{},"45 €\u002Fmois ou 360 €\u002Fan, HTVA",[34,129,130,135,138],{},[52,131,132],{},[55,133,134],{},"Essai gratuit",[52,136,137],{},"Toutes les fonctions pendant l'Early Access",[52,139,140],{},"Démo : max. 5 circuits, 1 page de plan de situation, filigrane",[34,142,143,148,151],{},[52,144,145],{},[55,146,147],{},"Schéma unifilaire",[52,149,150],{},"Oui",[52,152,150],{},[34,154,155,160,162],{},[52,156,157],{},[55,158,159],{},"Plan de situation",[52,161,150],{},[52,163,150],{},[34,165,166,171,174],{},[52,167,168],{},[55,169,170],{},"Plan du bâtiment",[52,172,173],{},"Dessin dans l'application, ou plan DXF en arrière-plan",[52,175,176],{},"Import AutoCAD DWG ou DXF en arrière-plan",[34,178,179,184,187],{},[52,180,181],{},[55,182,183],{},"Échelle à l'import",[52,185,186],{},"Reprise du fichier ; à défaut d'unité, une confirmation",[52,188,189],{},"L'arrière-plan se place comme une image",[34,191,192,197,200],{},[52,193,194],{},[55,195,196],{},"Répartition du tableau",[52,198,199],{},"Partie distincte du projet",[52,201,202],{},"Intégrée au schéma",[34,204,205,210,213],{},[52,206,207],{},[55,208,209],{},"Autocontrôle RGIE",[52,211,212],{},"Aide à la conception, pas un contrôle officiel",[52,214,215],{},"Appréciation par l'auteur du plan",[34,217,218,223,226],{},[52,219,220],{},[55,221,222],{},"Travail hors ligne",[52,224,225],{},"Non, connexion internet requise",[52,227,228],{},"Oui, hors ligne un certain temps après activation",[34,230,231,236,239],{},[52,232,233],{},[55,234,235],{},"Maturité",[52,237,238],{},"Récent, base d'utilisateurs réduite",[52,240,241],{},"15+ ans, selon leurs chiffres 14 000+ électriciens",[34,243,244,249,252],{},[52,245,246],{},[55,247,248],{},"Reprise des fichiers",[52,250,251],{},"Pas d'import de fichiers Trikker",[52,253,254],{},"—",[16,256,257],{},[258,259,260,261,268,269,274],"em",{},"Données Trikker vérifiées le 20 août 2026 sur ",[262,263,267],"a",{"href":264,"rel":265},"https:\u002F\u002Fwww.trikker.be\u002F",[266],"nofollow","trikker.be"," et ",[262,270,273],{"href":271,"rel":272},"https:\u002F\u002Fwww.trikker.be\u002Fpricing",[266],"trikker.be\u002Fpricing",". Prix et fonctions peuvent évoluer. Si vous constatez un écart, signalez-le-nous — nous adaptons ce tableau.",[23,276,278],{"id":277},"pourquoi-des-électriciens-cherchent-une-alternative","Pourquoi des électriciens cherchent une alternative",[16,280,281],{},"Trikker est depuis plus de quinze ans la référence établie pour les schémas unifilaires en Belgique. Ceux qui cherchent une alternative ne le font généralement pas parce que le programme fonctionne mal, mais parce que leur façon de travailler ne correspond plus à un poste fixe.",[16,283,284,287],{},[55,285,286],{},"Travailler sur plusieurs appareils."," Une licence Trikker vaut pour un PC à la fois. En changeant d'ordinateur, vous ressaisissez votre code de licence ; s'il est encore actif sur un autre appareil, il doit d'abord y être libéré. Qui alterne entre bureau, domicile et chantier s'y heurte régulièrement.",[16,289,290,293],{},[55,291,292],{},"Pas de Windows."," Trikker fonctionne aujourd'hui sous Windows. Une version macOS est annoncée pour la fin de l'été 2026, une version web devrait suivre. Qui travaille déjà sur Mac ou iPad n'a pas de solution opérationnelle actuellement.",[16,295,296,299],{},[55,297,298],{},"Le coût pour quelques schémas par an."," 45 € par mois ou 360 € par an représentent un investissement justifié pour un usage quotidien. Pour une entreprise qui établit quelques schémas par an, ou pour un propriétaire avec un seul dossier de vente, le calcul est différent.",[16,301,302,305],{},[55,303,304],{},"Installateurs germanophones."," Trikker est proposé en néerlandais, français et anglais. Dans les Cantons de l'Est, une partie des installateurs travaille en allemand. PlanElec est disponible en quatre langues, allemand compris.",[23,307,309],{"id":308},"la-vraie-différence-dessiner-ou-concevoir","La vraie différence : dessiner ou concevoir",[16,311,312],{},"C'est là que se situe la différence de fond entre les deux programmes, et c'est elle qui détermine si PlanElec constitue une amélioration pour vous ou non.",[16,314,315,318],{},[55,316,317],{},"Trikker est un logiciel de dessin."," Vous glissez les symboles RGIE sur une feuille et construisez ainsi votre schéma unifilaire et votre plan de situation. Vous décidez de la structure, vous gardez la vue d'ensemble, et le résultat correspond exactement à ce que vous avez dessiné. Cela donne un contrôle total, et pour qui maîtrise la norme, le travail avance vite.",[16,320,321,324],{},[55,322,323],{},"PlanElec part d'un modèle de projet."," Vous dessinez d'abord le plan du bâtiment, y placez les consommateurs, définissez les circuits et répartissez le tableau. Le schéma unifilaire en est déduit. Si vous ajoutez ensuite une prise ou un circuit, la représentation est reconstruite sans que vous ayez à redessiner le schéma à la main.",[16,326,327],{},"Cette différence a deux conséquences. Plan, circuits, tableau et schéma ne peuvent pas diverger, puisqu'ils proviennent des mêmes données — avec deux dessins séparés, cette cohérence est à votre charge. En contrepartie, vous êtes moins libre dans la mise en page : ce que le modèle ne connaît pas, vous ne pouvez pas non plus le dessiner.",[16,329,330],{},"Pour qui intègre des modifications tout au long d'une rénovation, le modèle de projet représente l'avantage pratique le plus net. Pour qui établit un schéma une seule fois sans y revenir, cet avantage pèse moins lourd.",[23,332,334],{"id":333},"quand-trikker-reste-le-meilleur-choix","Quand Trikker reste le meilleur choix",[16,336,337],{},"Certaines situations nous amènent à recommander Trikker, bien que nous soyons concurrents.",[16,339,340,343],{},[55,341,342],{},"Vous travaillez sans connexion internet."," Trikker a besoin d'une connexion pour l'activation et revérifie la licence de temps à autre, mais fonctionne hors ligne un certain temps entre-temps. PlanElec fonctionne dans le navigateur et nécessite une connexion. Sur des chantiers sans couverture réseau, c'est déterminant.",[16,345,346,349],{},[55,347,348],{},"Vous recevez vos plans uniquement en DWG."," PlanElec lit le DXF, Trikker lit en plus le DWG. Si les plans de l'architecte arrivent systématiquement en DWG et que leur auteur ne peut pas fournir de DXF, Trikker vous épargne cette conversion.",[16,351,352,355],{},[55,353,354],{},"Vous avez une méthode de travail rodée."," Quinze ans d'historique produit signifient une bibliothèque de symboles aboutie, une communauté d'utilisateurs active et des organismes de contrôle habitués à ces schémas. Changer une méthode en place demande du temps, et cet effort doit se justifier.",[16,357,358,361],{},[55,359,360],{},"Vous ne voulez pas d'un produit en Early Access."," PlanElec est récent. Cela implique une base d'utilisateurs plus réduite et des fonctions encore en développement. Qui n'a pas cette marge de manœuvre choisira mieux un produit établi.",[23,363,365],{"id":364},"ce-quil-faut-savoir-avant-de-changer","Ce qu'il faut savoir avant de changer",[367,368,370],"h3",{"id":369},"vos-schémas-existants-ne-suivent-pas","Vos schémas existants ne suivent pas",[16,372,373],{},"PlanElec ne peut pas lire les fichiers Trikker. La voie praticable pour changer : terminer les dossiers en cours dans Trikker et démarrer avec PlanElec au prochain nouveau projet. Redessiner intégralement une installation existante est possible, mais représente le temps d'un établissement normal.",[367,375,377],{"id":376},"ce-que-fait-lautocontrôle-et-ce-quil-ne-fait-pas","Ce que fait l'autocontrôle — et ce qu'il ne fait pas",[16,379,380,381,384],{},"L'autocontrôle RGIE de PlanElec est une aide à la conception. Il signale des points d'attention pris en charge, par exemple pour les dispositifs de protection et les sections de câbles, et indique les données manquantes. Il ne constitue ",[55,382,383],{},"pas un contrôle de conformité officiel"," et ne remplace pas la réception par un organisme agréé. Le rapport précise lui-même quels contrôles sont pris en charge et lesquels ne le sont pas — lisez-le avant de vous y fier.",[367,386,388],{"id":387},"ce-quun-organisme-de-contrôle-attend-du-document","Ce qu'un organisme de contrôle attend du document",[16,390,391],{},"Aucun logiciel de dessin, Trikker compris, ne rend un schéma automatiquement conforme. Ce qui compte, c'est que la documentation soit lisible, complète et conforme à la norme, et qu'elle corresponde à l'installation réelle. Les deux programmes produisent un PDF qui peut y répondre ; l'exactitude du contenu reste la responsabilité de l'auteur.",[367,393,395],{"id":394},"ce-que-signifie-concrètement-early-access","Ce que signifie concrètement « Early Access »",[16,397,398],{},"PlanElec est actuellement gratuit et aucun traitement de paiement n'est actif. Nous n'annonçons pas de prix futur aujourd'hui, parce que nous ne l'avons pas encore fixé. Ce que nous garantissons : vous exportez à tout moment votre schéma unifilaire et votre plan de situation en PDF. Ces documents restent exploitables, y compris indépendamment de l'application.",[23,400,402],{"id":401},"questions-fréquentes","Questions fréquentes",[16,404,405,408],{},[55,406,407],{},"Combien coûte Trikker en 2026 ?","\n45 € par mois HTVA (54,45 € TVAC pour les particuliers) ou 360 € par an HTVA (435,60 € TVAC). Les deux licences se renouvellent automatiquement et sont résiliables via le portail client. Une licence gratuite avec filigrane existe pour l'enseignement. Vérifié le 20 août 2026.",[16,410,411,414],{},[55,412,413],{},"Existe-t-il une alternative gratuite à Trikker ?","\nTrikker propose lui-même une version de démonstration gratuite, limitée à cinq circuits et une page de plan de situation, avec filigrane — utilisable pour essayer, pas pour des plans officiels. PlanElec est actuellement gratuit pendant l'Early Access, avec toutes les fonctions, export PDF compris.",[16,416,417,420],{},[55,418,419],{},"Trikker fonctionne-t-il sur Mac ?","\nPas aujourd'hui. Trikker fonctionne sous Windows ; une version macOS est annoncée pour la fin de l'été 2026 et une version web devrait suivre. PlanElec fonctionne déjà dans le navigateur sous macOS, Windows, Linux et sur iPad.",[16,422,423,426],{},[55,424,425],{},"Puis-je importer mes schémas Trikker dans PlanElec ?","\nNon. Il n'existe pas d'import de fichiers Trikker. Qui change termine ses dossiers en cours dans Trikker et démarre avec PlanElec au projet suivant.",[16,428,429,432],{},[55,430,431],{},"Puis-je utiliser le plan de mon architecte ?","\nOui. Chargez le plan au format DXF : PlanElec le place en arrière-plan de votre plan. Si le fichier porte une unité, PlanElec en reprend l'échelle. À défaut — cas fréquent, car les coordonnées DXF sont en soi sans unité — PlanElec propose une unité d'après les dimensions du bâtiment et vous demande de la confirmer. Dans les deux cas, ni redessin ni mesure de votre part. PlanElec ne lit pas le DWG : demandez alors un export DXF, que tout logiciel de CAO produit en quelques secondes.",[16,434,435,438],{},[55,436,437],{},"Un organisme de contrôle accepte-t-il un schéma issu de PlanElec ?","\nUn contrôleur apprécie si la documentation est lisible, complète et conforme à la norme et si elle correspond à l'installation — pas avec quel programme elle a été réalisée. PlanElec exporte schéma unifilaire et plan de situation en PDF avec des symboles normalisés. L'exactitude du contenu reste du ressort de l'auteur.",[23,440,442],{"id":441},"articles-liés","Articles liés",[444,445,446,453,459,465],"ul",{},[447,448,449],"li",{},[262,450,452],{"href":451},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Réaliser un schéma unifilaire : le guide complet",[447,454,455],{},[262,456,458],{"href":457},"\u002Ffr\u002Fblog\u002Fplan-de-situation","Qu'est-ce qu'un plan de situation ?",[447,460,461],{},[262,462,464],{"href":463},"\u002Ffr\u002Fblog\u002Fplanifier-tableau-electrique","Planifier un tableau électrique : structure et répartition",[447,466,467],{},[262,468,470],{"href":469},"\u002Ffr\u002Fblog\u002Fpremiers-pas-planelec","Premiers pas avec PlanElec",[23,472,474],{"id":473},"essayer-par-vous-même","Essayer par vous-même",[16,476,477,478,480,481],{},"Avec ",[55,479,42],{},", vous concevez plan, circuits et tableau au sein d'un même projet et exportez schéma unifilaire et plan de situation en PDF. Pendant l'Early Access, c'est actuellement gratuit, sans installation. L'autocontrôle accompagne la préparation et ne remplace pas un contrôle officiel. ",[262,482,485],{"href":483,"rel":484},"https:\u002F\u002Fplanelec.be",[266],"Commencer →",{"title":487,"searchDepth":488,"depth":488,"links":489},"",2,[490,491,492,493,494,501,502,503],{"id":25,"depth":488,"text":26},{"id":277,"depth":488,"text":278},{"id":308,"depth":488,"text":309},{"id":333,"depth":488,"text":334},{"id":364,"depth":488,"text":365,"children":495},[496,498,499,500],{"id":369,"depth":497,"text":370},3,{"id":376,"depth":497,"text":377},{"id":387,"depth":497,"text":388},{"id":394,"depth":497,"text":395},{"id":401,"depth":488,"text":402},{"id":441,"depth":488,"text":442},{"id":473,"depth":488,"text":474},"comparison","2026-08-22","Un comparatif factuel de PlanElec et Trikker : plateforme, prix, méthode de travail et aide au RGIE — y compris les cas où Trikker reste le meilleur choix.","md","fr",{},true,"\u002Fblog\u002Falternative-trikker.fr","8 min",{"title":6,"description":506},"alternative-trikker","blog\u002Falternative-trikker.fr",[45,42,517,518,519,520,521],"comparatif","schéma unifilaire","plan de situation","logiciel","RGIE","GF7gmCxafx9eOxrbc0eU83z-Z4JYsicOqPF1d3Vw1lc",{"id":524,"title":525,"articleId":526,"body":527,"category":906,"date":907,"description":908,"extension":507,"lastUpdated":909,"locale":508,"meta":910,"navigation":510,"path":911,"publishDate":907,"readTime":912,"refreshInterval":913,"seo":914,"slug":915,"stem":916,"tags":917,"__hash__":922},"blog\u002Fblog\u002Fvoltage-drop-cable-sizing.fr.md","Calculer la chute de tension : quelle longueur de câble ?","voltage-drop-cable-sizing",{"type":9,"value":528,"toc":886},[529,533,536,540,543,546,550,560,568,572,584,604,618,622,625,706,709,716,720,724,727,732,743,747,750,755,762,766,774,781,785,788,792,824,826,830,833,837,840,844,847,851,859,863],[12,530,532],{"id":531},"calculer-la-chute-de-tension-et-choisir-la-section-du-câble","Calculer la chute de tension et choisir la section du câble",[16,534,535],{},"Associer une section au disjoncteur est indispensable, mais ce n’est que le début du dimensionnement. Plus la canalisation est longue et le courant élevé, plus la tension disponible diminue au récepteur. Une section suffisante près du tableau peut donc devenir inadéquate pour un garage, une annexe ou une borne de recharge. Il faut répondre à deux questions distinctes : la protection est-elle compatible avec le conducteur, et la chute de tension reste-t-elle maîtrisée ? Le résultat le plus contraignant fixe la section provisoire.",[23,537,539],{"id":538},"dans-quels-cas-faut-il-y-penser","Dans quels cas faut-il y penser ?",[16,541,542],{},"La chute de tension devient surtout visible sur les longues liaisons : abri de jardin, éclairage extérieur, tableau secondaire, pompe à chaleur ou borne de recharge. Elle dépend cependant de bien plus que la distance. Le courant, le réseau mono- ou triphasé, le cuivre ou l’aluminium, la section, la tension nominale et le facteur de puissance interviennent tous.",[16,544,545],{},"Il faut aussi raisonner sur le trajet électrique complet depuis le tableau. Calculer uniquement les derniers mètres jusqu’à l’appareil sous-estime le total lorsque plusieurs tronçons se succèdent.",[23,547,549],{"id":548},"ce-que-dit-le-rgie-et-ce-quil-ne-dit-pas","Ce que dit le RGIE — et ce qu’il ne dit pas",[16,551,552,553,268,556,559],{},"Le Livre 1 du RGIE, sous-section 5.2.5, ne donne pas de pourcentage numérique. Il impose de limiter la chute de tension aux valeurs décrites dans les règles de l’art. Les seuils couramment employés de ",[55,554,555],{},"3 % pour l’éclairage",[55,557,558],{},"5 % pour les autres circuits terminaux"," proviennent de l’application usuelle d’IEC\u002FNBN HD 60364-5-52 ; ce ne sont pas des chiffres écrits tels quels dans le RGIE.",[16,561,562,563,567],{},"La section 5.2.1.2 demande en outre que le choix de la canalisation permette le fonctionnement sûr des appareils alimentés. Le tableau 4.11 de 4.4.1.4 limite, pour les installations domestiques, le calibre du dispositif de protection selon la section. Il ne démontre pas à lui seul la capacité de transport du câble dans toutes les conditions de pose. Le tableau 4.11 complet — avec les colonnes fusible et disjoncteur — figure dans ",[262,564,566],{"href":565},"\u002Ffr\u002Fblog\u002Fsection-cable-disjoncteur","notre tableau section de câble et disjoncteur",".",[23,569,571],{"id":570},"la-formule-utilisée","La formule utilisée",[16,573,574,575,579,580,583],{},"En prenant ",[576,577,578],"code",{},"L"," comme longueur ",[55,581,582],{},"aller simple"," :",[444,585,586,592,598],{},[447,587,588,589],{},"monophasé : ",[576,590,591],{},"ΔU = 2 × ρ × L × I × cos φ \u002F S",[447,593,594,595],{},"triphasé : ",[576,596,597],{},"ΔU = √3 × ρ × L × I × cos φ \u002F S",[447,599,600,601],{},"pourcentage : ",[576,602,603],{},"ΔU% = ΔU \u002F Un × 100",[16,605,606,609,610,613,614,617],{},[576,607,608],{},"ρ"," représente la résistivité du conducteur, ",[576,611,612],{},"I"," le courant et ",[576,615,616],{},"S"," la section en mm². Pour ce prédimensionnement, PlanElec utilise 0,0175 Ω·mm²\u002Fm pour le cuivre, 0,029 pour l’aluminium, cos φ 0,95 par défaut, ainsi que la tension nominale du circuit : 230 V pour les circuits terminaux monophasés et, pour les circuits triphasés, la tension entre conducteurs de phase (230 V ou 400 V). C’est un modèle résistif : la réactance et les corrections thermiques ne sont pas incluses.",[23,619,621],{"id":620},"quelle-tension-sapplique-à-votre-circuit","Quelle tension s’applique à votre circuit ?",[16,623,624],{},"L’erreur de raisonnement la plus fréquente en matière de chute de tension consiste à confondre la forme du réseau et le circuit. Les 400 V d’un raccordement triphasé ne se mesurent qu’entre deux conducteurs de phase. Un circuit de prises ou d’éclairage ordinaire se raccorde, même dans une telle habitation, entre un conducteur de phase et le neutre : il voit 230 V.",[28,626,627,643],{},[31,628,629],{},[34,630,631,634,637,640],{},[37,632,633],{},"Réseau au raccordement",[37,635,636],{},"Circuit",[37,638,639],{},"Tension nominale",[37,641,642],{},"Facteur",[47,644,645,659,671,683,695],{},[34,646,647,650,653,656],{},[52,648,649],{},"1×230 V",[52,651,652],{},"monophasé",[52,654,655],{},"230 V",[52,657,658],{},"2",[34,660,661,664,667,669],{},[52,662,663],{},"3×230 V sans neutre",[52,665,666],{},"monophasé, L–L",[52,668,655],{},[52,670,658],{},[34,672,673,675,678,680],{},[52,674,663],{},[52,676,677],{},"triphasé",[52,679,655],{},[52,681,682],{},"√3",[34,684,685,688,691,693],{},[52,686,687],{},"3N~400\u002F230 V",[52,689,690],{},"monophasé, L–N",[52,692,655],{},[52,694,658],{},[34,696,697,699,701,704],{},[52,698,687],{},[52,700,677],{},[52,702,703],{},"400 V",[52,705,682],{},[16,707,708],{},"Comme le facteur et la tension de référence changent ensemble, l’écart est important : les mêmes 16 A sur 30 m avec 2,5 mm² donnent 2,78 % en monophasé, mais 1,38 % pour un circuit triphasé sous 400 V. Calculer par erreur un circuit monophasé comme s’il était triphasé produit un résultat environ deux fois plus favorable et conduit à sous-dimensionner la section.",[16,710,711,712,567],{},"Dans un réseau sans neutre, un circuit monophasé est raccordé entre deux conducteurs de phase. La tension y vaut également 230 V et, comme les deux conducteurs transportent le courant complet, le facteur 2 reste d’application. Pour identifier votre forme de réseau, consultez ",[262,713,715],{"href":714},"\u002Ffr\u002Fblog\u002Fmonophase-triphase-belgique","Monophasé ou triphasé en Belgique",[23,717,719],{"id":718},"deux-exemples-concrets","Deux exemples concrets",[367,721,723],{"id":722},"éclairage-dun-abri-de-jardin","Éclairage d’un abri de jardin",[16,725,726],{},"Prenons 45 m de câble en cuivre, 230 V monophasé, 8 A et 1,5 mm². Avec cos φ 0,95 :",[16,728,729],{},[576,730,731],{},"ΔU = 2 × 0,0175 × 45 × 8 × 0,95 \u002F 1,5 = 7,98 V",[16,733,734,735,738,739,742],{},"La perte vaut ",[55,736,737],{},"3,47 %",", donc plus que la valeur de 3 % utilisée pour l’éclairage. En passant à 2,5 mm², elle tombe à ",[55,740,741],{},"4,79 V, soit 2,08 %",". Cette section est la première taille standard qui satisfait ce critère dans le prédimensionnement.",[367,744,746],{"id":745},"circuit-de-prises-dans-un-garage","Circuit de prises dans un garage",[16,748,749],{},"Pour une liaison cuivre de 30 m, 230 V, 16 A et 2,5 mm² :",[16,751,752],{},[576,753,754],{},"ΔU = 2 × 0,0175 × 30 × 16 × 0,95 \u002F 2,5 = 6,38 V",[16,756,757,758,761],{},"La chute atteint ",[55,759,760],{},"2,78 %",". Le calcul préliminaire emploie 5 % pour ce type de circuit : 2,5 mm² convient donc du point de vue de la chute de tension. Cela ne prouve pas encore que le câble est suffisamment chargé dans son mode de pose réel.",[23,763,765],{"id":764},"utiliser-le-calculateur-gratuit","Utiliser le calculateur gratuit",[16,767,768,769,773],{},"Le ",[262,770,772],{"href":771},"\u002Ffr\u002Ftools\u002Fcalcul-section-cable","calculateur de chute de tension et de section"," contrôle une section choisie ou cherche une taille provisoire. Il couvre les trois formes de réseau (1×230 V, 3×230 V et 3N~400\u002F230 V) et distingue circuits monophasés et triphasés, avec une charge exprimée en A, W, kW ou kVA, ainsi que des conducteurs en cuivre ou en aluminium. Il compare les sections normalisées et distingue le contrôle de la protection de celui de la chute de tension.",[16,775,776,777,780],{},"Le calcul s’exécute directement dans le navigateur, pour que les curseurs et le résultat évoluent sans délai ; le même noyau de calcul est aussi disponible via l’API PlanElec. Ce résultat reste un ",[55,778,779],{},"prédimensionnement",". L’outil ne vérifie ni le mode de pose, ni le groupement, la température, l’isolant, la réactance, le courant admissible, la tenue au court-circuit, les conditions de coupure, les bornes ou les données fabricant. Une personne compétente doit valider le choix définitif.",[23,782,784],{"id":783},"que-faire-si-la-chute-est-trop-élevée","Que faire si la chute est trop élevée ?",[16,786,787],{},"La première solution consiste souvent à augmenter la section. On peut aussi raccourcir le tracé ou installer un tableau secondaire plus près des charges. L’aluminium peut être intéressant sur une longue alimentation, à condition de prévoir les connexions et le dimensionnement adaptés. Pour une borne ou une pompe à chaleur, une alimentation triphasée réduit fortement le courant par phase à puissance totale identique. Une gestion dynamique de la charge peut enfin éviter de dépasser la puissance disponible.",[23,789,791],{"id":790},"erreurs-fréquentes","Erreurs fréquentes",[444,793,794,800,806,812,818],{},[447,795,796,799],{},[55,797,798],{},"Appliquer 3 % à tous les circuits."," Le calcul préliminaire utilise 3 % pour l’éclairage et 5 % pour les autres circuits.",[447,801,802,805],{},[55,803,804],{},"S’arrêter au tableau disjoncteur-section."," Il ne tient pas compte de la longueur ni de la charge réelle.",[447,807,808,811],{},[55,809,810],{},"Encoder l’aller-retour."," Il faut saisir la distance simple ; la formule monophasée contient déjà le facteur 2.",[447,813,814,817],{},[55,815,816],{},"Oublier les tronçons en amont."," Les chutes successives s’additionnent.",[447,819,820,823],{},[55,821,822],{},"Présenter le résultat comme une preuve de conformité."," Les conditions de pose et de court-circuit manquent encore.",[23,825,402],{"id":401},[367,827,829],{"id":828},"faut-il-indiquer-la-longueur-simple-ou-laller-retour","Faut-il indiquer la longueur simple ou l’aller-retour ?",[16,831,832],{},"Indiquez la distance simple entre le tableau et la charge. Le facteur 2 couvre le conducteur de retour en monophasé ; le calcul triphasé utilise √3.",[367,834,836],{"id":835},"une-section-de-15-mm-est-elle-permise-pour-léclairage","Une section de 1,5 mm² est-elle permise pour l’éclairage ?",[16,838,839],{},"Le RGIE 5.2.1.2 autorise 1,5 mm² pour un circuit terminal sans prise, si la protection et les autres conditions conviennent. Une grande longueur peut malgré tout imposer 2,5 mm² ou davantage.",[367,841,843],{"id":842},"une-section-plus-grande-est-elle-toujours-préférable","Une section plus grande est-elle toujours préférable ?",[16,845,846],{},"Elle réduit les pertes, mais augmente le coût, l’encombrement et les contraintes de raccordement. Le bon choix est la première section qui réussit toutes les vérifications pertinentes.",[367,848,850],{"id":849},"le-résultat-suffit-il-pour-le-contrôle-électrique","Le résultat suffit-il pour le contrôle électrique ?",[16,852,853,854,858],{},"Non. Il s’agit d’un contrôle de plausibilité, pas d’une note de calcul complète. Le ",[262,855,857],{"href":856},"\u002Ffr\u002Fblog\u002Fcontrole-electrique","dossier du contrôle électrique"," comprend aussi les schémas, protections, liaisons équipotentielles et autres exigences.",[23,860,862],{"id":861},"articles-associés","Articles associés",[444,864,865,870,874,880],{},[447,866,867],{},[262,868,869],{"href":565},"Section de câble selon le disjoncteur",[447,871,872],{},[262,873,715],{"href":714},[447,875,876],{},[262,877,879],{"href":878},"\u002Ffr\u002Fblog\u002Fborne-recharge-rgie","Installer une borne de recharge selon le RGIE",[447,881,882],{},[262,883,885],{"href":884},"\u002Ffr\u002Fblog\u002Fcircuit-dedie-obligatoire-appareils","Circuits dédiés pour les appareils",{"title":487,"searchDepth":488,"depth":488,"links":887},[888,889,890,891,892,896,897,898,899,905],{"id":538,"depth":488,"text":539},{"id":548,"depth":488,"text":549},{"id":570,"depth":488,"text":571},{"id":620,"depth":488,"text":621},{"id":718,"depth":488,"text":719,"children":893},[894,895],{"id":722,"depth":497,"text":723},{"id":745,"depth":497,"text":746},{"id":764,"depth":488,"text":765},{"id":783,"depth":488,"text":784},{"id":790,"depth":488,"text":791},{"id":401,"depth":488,"text":402,"children":900},[901,902,903,904],{"id":828,"depth":497,"text":829},{"id":835,"depth":497,"text":836},{"id":842,"depth":497,"text":843},{"id":849,"depth":497,"text":850},{"id":861,"depth":488,"text":862},"guide","2026-08-02","Calculez la chute de tension de votre câble et voyez quand une section plus grande s'impose. Outil gratuit pour la Belgique, sans inscription.","2026-08-17",{},"\u002Fblog\u002Fvoltage-drop-cable-sizing.fr","7 min",12,{"title":525,"description":908},"chute-de-tension-section-cable","blog\u002Fvoltage-drop-cable-sizing.fr",[918,919,920,921],"chute-de-tension","section-cable","calculateur","rgie","DibERU8cJ9pLRzPK4OtjdT8kCE04GXY0MGXbSDItZLY",{"id":924,"title":925,"articleId":926,"body":927,"category":906,"date":1230,"description":1231,"extension":507,"lastUpdated":1232,"locale":508,"meta":1233,"navigation":510,"path":1234,"publishDate":1230,"readTime":1235,"refreshInterval":913,"seo":1236,"slug":1237,"stem":1238,"tags":1239,"__hash__":1248},"blog\u002Fblog\u002Fsingle-phase-vs-three-phase.fr.md","Monophasé ou triphasé ? Réseau et raccordement en Belgique","single-phase-vs-three-phase",{"type":9,"value":928,"toc":1218},[929,933,936,951,962,966,1037,1040,1044,1047,1086,1089,1093,1113,1122,1126,1129,1133,1136,1140,1143,1147,1150,1154,1191,1193,1212],[23,930,932],{"id":931},"réponse-courte-il-nexiste-pas-seulement-deux-cas","Réponse courte : il n'existe pas seulement deux cas",[16,934,935],{},"En Belgique, il faut distinguer deux questions :",[937,938,939,945],"ol",{},[447,940,941,944],{},[55,942,943],{},"Le réseau basse tension dans la rue :"," 230 V sans neutre ou 400\u002F230 V avec neutre.",[447,946,947,950],{},[55,948,949],{},"Le raccordement individuel du bâtiment :"," monophasé ou triphasé.",[16,952,953,954,957,958,961],{},"« Monophasé = 1×230 V » décrit donc un raccordement, pas une forme distincte du réseau de rue. Le 230 V monophasé peut être fourni ",[55,955,956],{},"phase–neutre"," depuis un réseau 400\u002F230 V ou ",[55,959,960],{},"phase–phase"," depuis un réseau 3×230 V. ORES précise qu'un raccordement monophasé ne comporte pas systématiquement un neutre.",[23,963,965],{"id":964},"les-quatre-combinaisons","Les quatre combinaisons",[28,967,968,984],{},[31,969,970],{},[34,971,972,975,978,981],{},[37,973,974],{},"Réseau de rue",[37,976,977],{},"Raccordement du bâtiment",[37,979,980],{},"Conducteurs au raccordement",[37,982,983],{},"Notation technique",[47,985,986,1000,1012,1025],{},[34,987,988,991,994,997],{},[52,989,990],{},"400\u002F230 V avec N",[52,992,993],{},"Monophasé",[52,995,996],{},"L + N",[52,998,999],{},"1×230 V, L–N",[34,1001,1002,1004,1007,1010],{},[52,1003,990],{},[52,1005,1006],{},"Triphasé",[52,1008,1009],{},"L1 + L2 + L3 + N",[52,1011,687],{},[34,1013,1014,1017,1019,1022],{},[52,1015,1016],{},"230 V sans N",[52,1018,993],{},[52,1020,1021],{},"Deux conducteurs de phase",[52,1023,1024],{},"1×230 V, L–L",[34,1026,1027,1029,1031,1034],{},[52,1028,1016],{},[52,1030,1006],{},[52,1032,1033],{},"Trois conducteurs de phase",[52,1035,1036],{},"3×230 V sans N",[16,1038,1039],{},"Le réseau 3×230 V n'est pas anecdotique. Fluvius comptait encore 18 101 km de réseau basse tension 230 V fin 2024, surtout dans les zones urbaines et occidentales. Sibelga indique qu'environ 80 % de Bruxelles est couvert en 230 V. Cela ne signifie pas que chaque logement y est triphasé : Sibelga présente 9,2 kVA, en monophasé 230 V à 40 A, comme raccordement domestique standard.",[23,1041,1043],{"id":1042},"puissance-avec-le-même-calibre","Puissance avec le même calibre",[16,1045,1046],{},"ORES publie les valeurs suivantes à 40 A :",[28,1048,1049,1060],{},[31,1050,1051],{},[34,1052,1053,1056],{},[37,1054,1055],{},"Raccordement",[37,1057,1059],{"align":1058},"right","Puissance apparente à 40 A",[47,1061,1062,1070,1078],{},[34,1063,1064,1067],{},[52,1065,1066],{},"Monophasé 230 V",[52,1068,1069],{"align":1058},"9,2 kVA",[34,1071,1072,1075],{},[52,1073,1074],{},"Triphasé 3×230 V",[52,1076,1077],{"align":1058},"15,9 kVA",[34,1079,1080,1083],{},[52,1081,1082],{},"Triphasé 3N~400\u002F230 V",[52,1084,1085],{"align":1058},"27,7 kVA",[16,1087,1088],{},"La capacité réelle dépend toujours du disjoncteur de raccordement et des données du gestionnaire de réseau.",[23,1090,1092],{"id":1091},"borne-pompe-à-chaleur-et-photovoltaïque","Borne, pompe à chaleur et photovoltaïque",[444,1094,1095,1101,1107],{},[447,1096,1097,1100],{},[55,1098,1099],{},"Borne de recharge :"," 3,7 ou 7,4 kW peuvent être possibles en monophasé. Pour 11 ou 22 kW, il faut normalement un raccordement triphasé adapté. Tous les appareils ne fonctionnent pas en 3×230 V ; Sibelga signale des restrictions pour la recharge à 11\u002F22 kW.",[447,1102,1103,1106],{},[55,1104,1105],{},"Pompe à chaleur et taque de cuisson :"," vérifiez la plaque signalétique. Un appareil prévu pour 3N~400 V ne fonctionne pas automatiquement sur 3×230 V sans neutre.",[447,1108,1109,1112],{},[55,1110,1111],{},"Photovoltaïque :"," la puissance d'onduleur admise et la répartition des phases dépendent du gestionnaire et du raccordement réel. Une limite belge générale de 5 kWc serait trompeuse.",[16,1114,1115,1116,268,1119,567],{},"Avant un achat important, vérifiez donc à la fois ",[55,1117,1118],{},"mono\u002Ftriphasé",[55,1120,1121],{},"230 V sans N\u002F400-230 V avec N",[23,1123,1125],{"id":1124},"différentiel-sur-un-réseau-3230-v","Différentiel sur un réseau 3×230 V",[16,1127,1128],{},"Un dispositif différentiel n'a pas besoin du neutre comme « référence ». Il compare les courants dans tous les conducteurs actifs qui le traversent. En 3×230 V, les conducteurs de phase concernés doivent donc être mesurés et coupés ensemble. L'ancienne affirmation générale selon laquelle l'absence de neutre réduirait la protection différentielle était incorrecte.",[23,1130,1132],{"id":1131},"équilibrage-des-phases","Équilibrage des phases",[16,1134,1135],{},"Une répartition raisonnable des charges est une bonne pratique pour un raccordement triphasé. Le RGIE ne fixe toutefois pas une limite générale exacte de 30 %. Un tel seuil peut servir d'alerte de planification, mais ne doit pas être présenté comme une citation réglementaire. En monophasé, il n'y a pas trois phases à équilibrer.",[23,1137,1139],{"id":1138},"identifier-votre-raccordement","Identifier votre raccordement",[16,1141,1142],{},"Vérifiez le compteur, le disjoncteur de raccordement et les conducteurs entrants sans ouvrir les parties plombées. ORES illustre le monophasé 230 V, le 3×230 V et le 3×400 V + N. En cas de doute, le gestionnaire ou un électricien peut confirmer le raccordement. Le simple comptage des fils visibles peut être trompeur à cause du PE, du câblage interne ou d'une ancienne installation.",[23,1144,1146],{"id":1145},"renforcement-ou-modification","Renforcement ou modification",[16,1148,1149],{},"Il n'existe ni prix ni délai belge unique. Ils dépendent du gestionnaire, de la puissance demandée, du réseau disponible dans la rue, de l'emplacement du compteur et des adaptations intérieures. Demandez d'abord une offre concrète au gestionnaire compétent. Une modification importante peut aussi imposer des schémas mis à jour et un nouveau contrôle.",[23,1151,1153],{"id":1152},"sources","Sources",[444,1155,1156,1163,1170,1177,1184],{},[447,1157,1158],{},[262,1159,1162],{"href":1160,"rel":1161},"https:\u002F\u002Fwww.ores.be\u002Fparticulier\u002Freconnaitre-informations-techniques\u002F",[266],"ORES : reconnaître les informations techniques",[447,1164,1165],{},[262,1166,1169],{"href":1167,"rel":1168},"https:\u002F\u002Fwww.sibelga.be\u002Ffr\u002Fraccordements-compteurs\u002Fmon-raccordement\u002Fpuissance-electrique",[266],"Sibelga : puissance électrique et raccordement",[447,1171,1172],{},[262,1173,1176],{"href":1174,"rel":1175},"https:\u002F\u002Fwww.sibelga.be\u002Ffr\u002Fraccordements-compteurs\u002Frecharge-electrique\u002Frecharge-a-domicile",[266],"Sibelga : recharge à domicile",[447,1178,1179],{},[262,1180,1183],{"href":1181,"rel":1182},"https:\u002F\u002Fover.fluvius.be\u002Fsites\u002Ffluvius\u002Ffiles\u002F2025-06\u002Finvesteringsplan-2026-2035-versie-publieke-consultatie.pdf",[266],"Fluvius : plan d'investissement 2026–2035",[447,1185,1186],{},[262,1187,1190],{"href":1188,"rel":1189},"https:\u002F\u002Fdownload.schneider-electric.com\u002Ffiles?p_File_Id=905251744&p_File_Name=ECT114.pdf&p_Reference=ECT114&p_enDocType=Cahier+Technique",[266],"Schneider Electric : principe de fonctionnement des différentiels, y compris les circuits triphasés sans neutre",[23,1192,862],{"id":861},[444,1194,1195,1201,1206],{},[447,1196,1197],{},[262,1198,1200],{"href":1199},"\u002Ffr\u002Fblog\u002Fchute-de-tension-section-cable","Calculer la chute de tension et choisir la section",[447,1202,1203],{},[262,1204,1205],{"href":878},"Installer une borne en Belgique",[447,1207,1208],{},[262,1209,1211],{"href":1210},"\u002Ffr\u002Fblog\u002Fpanneaux-solaires-schema","Déclarer et documenter une installation PV",[16,1213,1214],{},[262,1215,1217],{"href":1216},"\u002F","Documenter séparément réseau et raccordement dans PlanElec →",{"title":487,"searchDepth":488,"depth":488,"links":1219},[1220,1221,1222,1223,1224,1225,1226,1227,1228,1229],{"id":931,"depth":488,"text":932},{"id":964,"depth":488,"text":965},{"id":1042,"depth":488,"text":1043},{"id":1091,"depth":488,"text":1092},{"id":1124,"depth":488,"text":1125},{"id":1131,"depth":488,"text":1132},{"id":1138,"depth":488,"text":1139},{"id":1145,"depth":488,"text":1146},{"id":1152,"depth":488,"text":1153},{"id":861,"depth":488,"text":862},"2026-07-27","1×230 V, 3×230 V ou 3N~400\u002F230 V : distinguez réseau de rue, neutre et nombre de phases du raccordement.","2026-08-03",{},"\u002Fblog\u002Fsingle-phase-vs-three-phase.fr","6 min",{"title":925,"description":1231},"monophase-triphase-belgique","blog\u002Fsingle-phase-vs-three-phase.fr",[1240,521,652,677,1241,1242,1243,1244,1245,1246,1247,518],"AREI","Belgique","Fluvius","ORES","Sibelga","borne de recharge","pompe à chaleur","panneaux solaires","gp9dAeeWm6kXmQfeU9oQnekqiDM7CfxAFstDVoHDgAg",{"id":1250,"title":1251,"articleId":1252,"body":1253,"category":906,"date":1563,"description":1564,"extension":507,"lastUpdated":909,"locale":508,"meta":1565,"navigation":510,"path":1566,"publishDate":1563,"readTime":512,"refreshInterval":1567,"seo":1568,"slug":1569,"stem":1570,"tags":1571,"__hash__":1576},"blog\u002Fblog\u002Fplanelec-capabilities-overview.fr.md","Que peut-on faire avec PlanElec ? Fonctions, automatisation et exports","planelec-capabilities-overview",{"type":9,"value":1254,"toc":1551},[1255,1258,1264,1268,1362,1366,1369,1372,1376,1379,1402,1410,1414,1417,1420,1424,1427,1446,1449,1452,1460,1464,1467,1474,1478,1481,1491,1499,1503,1524,1527,1531,1534],[16,1256,1257],{},"PlanElec réunit le flux belge de planification électrique dans un projet commun : du plan aux récepteurs, câbles, circuits et tableau, puis au schéma unifilaire, au plan de situation et aux différentes sorties PDF. L'outil s'adresse en priorité aux entreprises d'électricité et aux bureaux d'études, tout en restant accessible aux maîtres d'ouvrage et propriétaires motivés.",[16,1259,1260,1261],{},"La réponse courte est la suivante : ",[55,1262,1263],{},"vous modélisez une fois la structure spatiale et électrique, puis vous en déduisez des plans, des listes et un auto-contrôle RGIE pris en charge.",[23,1265,1267],{"id":1266},"le-flux-en-un-coup-dœil","Le flux en un coup d'œil",[28,1269,1270,1283],{},[31,1271,1272],{},[34,1273,1274,1277,1280],{},[37,1275,1276],{},"Étape",[37,1278,1279],{},"Ce que vous faites dans PlanElec",[37,1281,1282],{},"Résultat",[47,1284,1285,1296,1307,1318,1329,1340,1351],{},[34,1286,1287,1290,1293],{},[52,1288,1289],{},"Projet",[52,1291,1292],{},"Créer le bâtiment, les étages et les métadonnées",[52,1294,1295],{},"Base commune des plans et cartouches",[34,1297,1298,1301,1304],{},[52,1299,1300],{},"Plan",[52,1302,1303],{},"Dessiner les murs et les pièces ou calibrer une image de référence",[52,1305,1306],{},"Modèle spatial",[34,1308,1309,1312,1315],{},[52,1310,1311],{},"Équipements",[52,1313,1314],{},"Placer prises, interrupteurs, luminaires, raccordements fixes et tableaux",[52,1316,1317],{},"Plan de situation et base des récepteurs",[34,1319,1320,1323,1326],{},[52,1321,1322],{},"Topologie",[52,1324,1325],{},"Relier circuits, protections, câbles et dérivations",[52,1327,1328],{},"Modèle électrique",[34,1330,1331,1334,1337],{},[52,1332,1333],{},"Tableau",[52,1335,1336],{},"Disposer les modules sur les rails DIN et vérifier les chaînes de protection",[52,1338,1339],{},"Planification modifiable du tableau",[34,1341,1342,1345,1348],{},[52,1343,1344],{},"Schéma et contrôle",[52,1346,1347],{},"Vérifier le schéma unifilaire et lancer l'auto-contrôle pris en charge",[52,1349,1350],{},"Constats et schéma documentable",[34,1352,1353,1356,1359],{},[52,1354,1355],{},"Export",[52,1357,1358],{},"Produire des PDF séparés ou un dossier de travail sélectionnable",[52,1360,1361],{},"Documents de projet pour contrôle et coordination",[23,1363,1365],{"id":1364},"créer-le-plan-et-le-plan-de-situation","Créer le plan et le plan de situation",[16,1367,1368],{},"Dans l'éditeur SVG, vous dessinez les murs extérieurs et intérieurs sous forme de polygone, de rectangle ou de segments. Les surfaces fermées deviennent des pièces. Vous pouvez importer un plan existant comme image de référence, le faire pivoter et le calibrer sur une distance connue.",[16,1370,1371],{},"Vous placez ensuite les symboles électriques sur les murs ou librement dans la pièce : prises, interrupteurs, luminaires, raccordements spéciaux, boîtes de connexion et de dérivation, tableaux, entre autres. Les chaînes d'interrupteurs et les chemins de câble restent visibles dans le même modèle spatial. Le plan de situation produit reprend ces positions réelles.",[23,1373,1375],{"id":1374},"préparer-automatiquement-les-étapes-répétitives","Préparer automatiquement les étapes répétitives",[16,1377,1378],{},"PlanElec propose plusieurs automatismes que vous pouvez contrôler séparément :",[444,1380,1381,1384,1387,1390,1393,1396,1399],{},[447,1382,1383],{},"propositions de prises, d'éclairage, d'équipement standard et de grilles de spots ;",[447,1385,1386],{},"liaison automatique des interrupteurs et luminaires libres d'une pièce ;",[447,1388,1389],{},"segments de câble issus des relations topologiques et trajets le long des murs ;",[447,1391,1392],{},"regroupement et affectation automatiques des récepteurs aux circuits ;",[447,1394,1395],{},"traitement séparé des appareils spéciaux pris en charge ;",[447,1397,1398],{},"répartition des phases dans une installation polyphasée ;",[447,1400,1401],{},"placement automatique des protections existantes sur les rails DIN avec réserve de place.",[16,1403,1404,1405,1409],{},"L'automatisation ne constitue pas une étude professionnelle infaillible. Les propositions peuvent être déplacées et réaffectées, et les trajets ou longueurs de câble peuvent être corrigés manuellement. Le guide ",[262,1406,1408],{"href":1407},"\u002Ffr\u002Fhelp\u002Fplanification-automatique","Planification automatique"," décrit le processus en détail.",[23,1411,1413],{"id":1412},"planifier-ensemble-le-tableau-et-le-schéma-unifilaire","Planifier ensemble le tableau et le schéma unifilaire",[16,1415,1416],{},"Dans l'éditeur du tableau, vous disposez l'interrupteur principal, les différentiels, les disjoncteurs et les accessoires pris en charge sur une grille réelle en modules. Les protections peuvent être placées automatiquement, puis déplacées ou reliées manuellement. Pour plusieurs phases, PlanElec affiche les charges modélisées et avertit en cas de déséquilibre marqué.",[16,1418,1419],{},"Le schéma unifilaire est dérivé de la topologie électrique. Les branches de récepteurs, protections, dérivations et données de câble restent ainsi reliées au modèle du projet. Après une modification, le schéma peut être reconstruit à partir de l'état actuel, sans devoir comparer manuellement plusieurs dessins indépendants.",[23,1421,1423],{"id":1422},"quels-documents-peut-on-exporter","Quels documents peut-on exporter ?",[16,1425,1426],{},"Les sorties centrales actuellement disponibles sont :",[444,1428,1429,1436,1441],{},[447,1430,1431,1432,1435],{},"le ",[55,1433,1434],{},"schéma unifilaire en PDF multipage"," ;",[447,1437,1431,1438,1435],{},[55,1439,1440],{},"plan de situation en PDF",[447,1442,1431,1443,567],{},[55,1444,1445],{},"rapport indicatif d'auto-contrôle RGIE",[16,1447,1448],{},"Le flux de développement\u002Fpilote ajoute les listes de circuits, de matériel et de câbles. La liste de matériel décompose les contributions modélisées de manière générique et indépendante des fabricants, en affichant ses hypothèses standard. Elle ne contient ni prix ni référence fabricant concrète et ne constitue pas encore une validation de commande.",[16,1450,1451],{},"Le générateur de dossier peut réunir les documents sélectionnés dans un PDF de travail avec page de garde, sommaire et pagination globale. Ce dossier est une sortie locale de pilote et de contrôle, pas encore un snapshot serveur final versionné. Le PDF du tableau n'est disponible que si le feature flag correspondant est actif et si le tableau contient des données.",[16,1453,1454,1455,1459],{},"Consultez ",[262,1456,1458],{"href":1457},"\u002Ffr\u002Fhelp\u002Fexporter-les-documents","Exporter les documents"," pour le statut de chaque sortie et les étapes de téléchargement.",[23,1461,1463],{"id":1462},"que-contrôle-planelec-par-rapport-au-rgie","Que contrôle PlanElec par rapport au RGIE ?",[16,1465,1466],{},"L'auto-contrôle assisté par logiciel couvre une partie documentée des règles évaluables à partir des données enregistrées. Il peut afficher des constats dans les domaines pris en charge et signaler les lacunes de couverture détectées.",[16,1468,1469,1470,1473],{},"Il ne s'agit ",[55,1471,1472],{},"ni d'un certificat de conformité",", ni d'une garantie de réussite au contrôle. Les mesures, conditions sur place, justificatifs de fabricants et domaines réglementaires qui ne sont pas entièrement modélisés restent hors de portée d'un contrôle purement logiciel. Seul un organisme de contrôle agréé rend l'évaluation officielle.",[367,1475,1477],{"id":1476},"quelle-est-létendue-exacte-de-cette-partie","Quelle est l'étendue exacte de cette partie ?",[16,1479,1480],{},"Un installateur nous a posé la question sans détour : PlanElec couvre-t-il tout le Livre 1, y compris toutes les exceptions, ou seulement les cas les plus courants ? La réponse honnête est la seconde.",[16,1482,768,1483,1486,1487,1490],{},[55,1484,1485],{},"texte réglementaire intégré"," est complet — Livre 1, Version 06, Parties 1 à 9. La ",[55,1488,1489],{},"logique de contrôle automatique"," n'en couvre qu'une partie : l'accent porte sur la protection, la mise à la terre, le dimensionnement des câbles et la complétude du dossier dans une installation domestique à courant alternatif. Le côté courant continu, onze des quatorze chapitres consacrés aux installations particulières ainsi que les exceptions transitoires des articles 59 et 69 n'en font pas partie.",[16,1492,1493,1494,1498],{},"Nous préférons publier cette limite plutôt que de la laisser découvrir : ",[262,1495,1497],{"href":1496},"\u002Ffr\u002Fhelp\u002Fce-que-verifie-l-autocontrole","la liste complète de ce que l'autocontrôle vérifie et ne vérifie pas"," figure dans la base de connaissances.",[23,1500,1502],{"id":1501},"à-qui-planelec-sadresse-t-il","À qui PlanElec s'adresse-t-il ?",[444,1504,1505,1512,1518],{},[447,1506,1507,1508,1511],{},"Les ",[55,1509,1510],{},"entreprises d'électricité"," disposent d'un flux continu de la saisie aux plans et aux listes.",[447,1513,1507,1514,1517],{},[55,1515,1516],{},"bureaux d'études"," peuvent modéliser ensemble les relations spatiales et électriques et adapter les variantes de manière traçable.",[447,1519,1507,1520,1523],{},[55,1521,1522],{},"maîtres d'ouvrage et propriétaires motivés"," peuvent structurer un relevé ou une préparation, mais doivent faire valider le résultat par un électricien qualifié avant les travaux.",[16,1525,1526],{},"PlanElec ne remplace ni l'étude professionnelle, ni l'exécution, ni le contrôle officiel.",[23,1528,1530],{"id":1529},"état-actuel-de-learly-access","État actuel de l'Early Access",[16,1532,1533],{},"L'Early Access coûte actuellement 0 EUR et aucun paiement n'est encore actif. Les fonctions pilotes restent accompagnées de leur statut visible. Aucun prix public ni abonnement Pro achetable n'est publié à ce jour.",[16,1535,1536,1537,1541,1542,1546,1547,567],{},"Pour aller plus loin, consultez la ",[262,1538,1540],{"href":1539},"\u002Ffr\u002Ffeatures","vue complète des fonctionnalités",", suivez les guides de la ",[262,1543,1545],{"href":1544},"\u002Ffr\u002Fhelp","base de connaissances"," ou ",[262,1548,1550],{"href":1549},"\u002Fauth\u002Fregister","inscrivez-vous à PlanElec",{"title":487,"searchDepth":488,"depth":488,"links":1552},[1553,1554,1555,1556,1557,1558,1561,1562],{"id":1266,"depth":488,"text":1267},{"id":1364,"depth":488,"text":1365},{"id":1374,"depth":488,"text":1375},{"id":1412,"depth":488,"text":1413},{"id":1422,"depth":488,"text":1423},{"id":1462,"depth":488,"text":1463,"children":1559},[1560],{"id":1476,"depth":497,"text":1477},{"id":1501,"depth":488,"text":1502},{"id":1529,"depth":488,"text":1530},"2026-07-20","Du plan à l’affectation automatique des circuits et du tableau, puis au schéma unifilaire, au plan de situation et au dossier PDF : un aperçu honnête.",{},"\u002Fblog\u002Fplanelec-capabilities-overview.fr",6,{"title":1251,"description":1564},"que-peut-on-faire-avec-planelec","blog\u002Fplanelec-capabilities-overview.fr",[42,1572,519,518,1573,1574,1575],"planification électrique","tableau électrique","automatisation","export PDF","kP0LTXyR0shwWHDNd903o81_GbvPlJO1jndUmSYNAus",{"id":1578,"title":1579,"articleId":1580,"body":1581,"category":906,"date":1563,"description":2233,"extension":507,"lastUpdated":2234,"locale":508,"meta":2235,"navigation":510,"path":2236,"publishDate":1563,"readTime":512,"refreshInterval":913,"seo":2237,"slug":2238,"stem":2239,"tags":2240,"__hash__":2247},"blog\u002Fblog\u002Frenovation-electrical-plans.fr.md","Rénovation et RGIE : Quand avez-vous besoin de nouveaux plans électriques ?","renovation-electrical-plans",{"type":9,"value":1582,"toc":2210},[1583,1587,1594,1598,1602,1605,1688,1692,1695,1758,1771,1775,1778,1785,1789,1792,1817,1821,1842,1846,1849,1904,1908,1911,1935,1939,1943,1946,1966,1970,1977,1997,2005,2009,2065,2069,2072,2101,2105,2108,2145,2148,2175,2179,2205],[23,1584,1586],{"id":1585},"quand-une-rénovation-déclenche-t-elle-un-contrôle-obligatoire","Quand une rénovation déclenche-t-elle un contrôle obligatoire ?",[16,1588,1589,1590,1593],{},"Toute rénovation ne nécessite pas de nouveaux plans électriques et un nouveau contrôle. Le RGIE distingue clairement les travaux qui déclenchent un ",[55,1591,1592],{},"nouveau contrôle"," de ceux qui ne le font pas. Ce guide vous explique quelle règle s'applique à votre rénovation.",[23,1595,1597],{"id":1596},"larbre-de-décision-nouveau-contrôle-oui-ou-non","L'arbre de décision : Nouveau contrôle oui ou non ?",[367,1599,1601],{"id":1600},"nouveau-contrôle-requis","Nouveau contrôle REQUIS",[16,1603,1604],{},"Les travaux suivants déclenchent un contrôle obligatoire (Art. 6.4.7.3) :",[28,1606,1607,1617],{},[31,1608,1609],{},[34,1610,1611,1614],{},[37,1612,1613],{},"Travaux",[37,1615,1616],{},"Raison",[47,1618,1619,1629,1639,1648,1658,1668,1678],{},[34,1620,1621,1626],{},[52,1622,1623],{},[55,1624,1625],{},"Ajouter de nouveaux circuits",[52,1627,1628],{},"Extension de l'installation",[34,1630,1631,1636],{},[52,1632,1633],{},[55,1634,1635],{},"Remplacer le tableau de distribution",[52,1637,1638],{},"Modification des dispositifs de protection",[34,1640,1641,1646],{},[52,1642,1643],{},[55,1644,1645],{},"Installer un sous-tableau",[52,1647,1628],{},[34,1649,1650,1655],{},[52,1651,1652],{},[55,1653,1654],{},"Poser de nouveaux câbles",[52,1656,1657],{},"Modification substantielle",[34,1659,1660,1665],{},[52,1661,1662],{},[55,1663,1664],{},"Modifier l'installation de mise à la terre",[52,1666,1667],{},"Critique pour la sécurité",[34,1669,1670,1675],{},[52,1671,1672],{},[55,1673,1674],{},"Passer en triphasé",[52,1676,1677],{},"Modification fondamentale",[34,1679,1680,1685],{},[52,1681,1682],{},[55,1683,1684],{},"Raccorder une borne de recharge \u002F pompe à chaleur",[52,1686,1687],{},"Nouveau circuit dédié",[367,1689,1691],{"id":1690},"nouveau-contrôle-non-requis","Nouveau contrôle NON REQUIS",[16,1693,1694],{},"Ces travaux sont considérés comme de la maintenance :",[28,1696,1697,1706],{},[31,1698,1699],{},[34,1700,1701,1703],{},[37,1702,1613],{},[37,1704,1705],{},"Pourquoi pas de nouveau contrôle",[47,1707,1708,1718,1728,1738,1748],{},[34,1709,1710,1715],{},[52,1711,1712],{},[55,1713,1714],{},"Remplacement 1-pour-1 d'une prise\u002Finterrupteur",[52,1716,1717],{},"Même position, même puissance",[34,1719,1720,1725],{},[52,1721,1722],{},[55,1723,1724],{},"Remplacer une lampe par une LED",[52,1726,1727],{},"Pas d'intervention sur l'installation",[34,1729,1730,1735],{},[52,1731,1732],{},[55,1733,1734],{},"Peindre, tapisser, poser des sols",[52,1736,1737],{},"Cosmétique, pas de raccordement électrique",[34,1739,1740,1745],{},[52,1741,1742],{},[55,1743,1744],{},"Remplacement 1-pour-1 d'un disjoncteur",[52,1746,1747],{},"Même type et courant nominal",[34,1749,1750,1755],{},[52,1751,1752],{},[55,1753,1754],{},"Changer un couvercle de prise",[52,1756,1757],{},"Pas d'intervention sur le câblage",[1759,1760,1761],"blockquote",{},[16,1762,1763,1766,1767,1770],{},[55,1764,1765],{},"Zone grise"," : Déplacer une prise vers une ",[55,1768,1769],{},"autre position"," constitue déjà une modification. Toute modification ou extension significative déclenche un nouveau contrôle (Art. 6.4.7.3) — même si le circuit reste le même.",[23,1772,1774],{"id":1773},"la-règle-de-contamination","La règle de contamination",[16,1776,1777],{},"La règle de contamination est le concept le plus important lors des rénovations :",[1759,1779,1780],{},[16,1781,1782],{},[55,1783,1784],{},"Si vous modifiez une partie de l'installation, le contrôleur peut remettre en question l'ensemble de l'installation.",[367,1786,1788],{"id":1787},"ce-que-cela-signifie-en-pratique","Ce que cela signifie en pratique",[16,1790,1791],{},"Supposons que vous rénovez votre salle de bain et y installez de nouvelles prises et un nouvel éclairage :",[937,1793,1794,1805,1811],{},[447,1795,1796,1797,1800,1801,1804],{},"La ",[55,1798,1799],{},"salle de bain"," est évaluée selon le ",[55,1802,1803],{},"RGIE actuel"," — toutes les prescriptions actuelles s'appliquent",[447,1806,1807,1808],{},"Le contrôleur peut également vérifier le ",[55,1809,1810],{},"reste de l'installation",[447,1812,1813,1814],{},"Les défauts existants (p. ex. différentiels manquants à la cave) peuvent ",[55,1815,1816],{},"également être signalés",[367,1818,1820],{"id":1819},"comment-limiter-la-contamination","Comment limiter la contamination",[444,1822,1823,1829,1835],{},[447,1824,1825,1828],{},[55,1826,1827],{},"Documentez précisément"," quelles parties ont été modifiées et lesquelles ne l'ont pas été",[447,1830,1831,1832],{},"Marquez dans le schéma unifilaire les ",[55,1833,1834],{},"circuits nouveaux\u002Fmodifiés",[447,1836,1837,1838,1841],{},"Les parties inchangées relèvent du ",[55,1839,1840],{},"Part 8"," (exigences assouplies)",[23,1843,1845],{"id":1844},"part-8-vs-rgie-complet-que-sapplique-quand","Part 8 vs. RGIE complet : Que s'applique quand ?",[16,1847,1848],{},"Le RGIE distingue entre ancien et nouveau :",[28,1850,1851,1864],{},[31,1852,1853],{},[34,1854,1855,1858,1861],{},[37,1856,1857],{},"Partie de l'installation",[37,1859,1860],{},"Prescription applicable",[37,1862,1863],{},"Exigences",[47,1865,1866,1879,1892],{},[34,1867,1868,1873,1876],{},[52,1869,1870],{},[55,1871,1872],{},"Inchangée, avant 1981",[52,1874,1875],{},"Part 8 Art. 8.2 (installation existante)",[52,1877,1878],{},"Assouplies — p. ex. pas de différentiel par circuit requis, anciens types de câbles tolérés",[34,1880,1881,1886,1889],{},[52,1882,1883],{},[55,1884,1885],{},"Inchangée, 1981–2020",[52,1887,1888],{},"Part 8 Section 8.2.2 (dérogations pour installations domestiques selon l'ancien R.G.I.E.)",[52,1890,1891],{},"Doit correspondre à la prescription de l'époque, avec des allègements limités selon Art. 8.2.2",[34,1893,1894,1899,1901],{},[52,1895,1896],{},[55,1897,1898],{},"Modifiée \u002F Nouvelle",[52,1900,1803],{},[52,1902,1903],{},"Toutes les prescriptions actuelles (différentiel principal 300 mA + différentiel 30 mA à haute sensibilité pour les circuits prises, éclairage et salle de bain, SPD pour la partie nouvelle\u002Fmodifiée, normes de câbles)",[367,1905,1907],{"id":1906},"scénario-typique-maison-des-années-1960","Scénario typique : Maison des années 1960",[16,1909,1910],{},"Vous rénovez la cuisine et la salle de bain d'une maison de 1965 :",[444,1912,1913,1919,1925],{},[447,1914,1915,1918],{},[55,1916,1917],{},"Cuisine + salle de bain"," (nouveaux circuits) : RGIE actuel complet — SPD attendu selon les règles de l'art (Art. 4.5.1, principe général ; uniquement pour la partie nouvelle\u002Fmodifiée de l'installation), différentiel principal 300 mA pour l'ensemble de l'installation (Art. 4.2.4.3) + différentiel 30 mA à haute sensibilité pour les circuits prises, éclairage et salle de bain (Art. 4.2.4.3 point b), types de câbles actuels",[447,1920,1921,1924],{},[55,1922,1923],{},"Chambres, salon"," (inchangés) : Part 8 — anciens câbles VOB tolérés, pas de différentiel par circuit requis",[447,1926,1927,1930,1931,1934],{},[55,1928,1929],{},"Mais"," : Si le contrôleur constate que l'ancienne installation présente un ",[55,1932,1933],{},"risque de sécurité direct"," (p. ex. fils dénudés, mise à la terre manquante), il peut quand même exiger une mise en conformité",[23,1936,1938],{"id":1937},"documentation-lors-dune-rénovation","Documentation lors d'une rénovation",[367,1940,1942],{"id":1941},"maisons-avec-plans-existants","Maisons avec plans existants",[16,1944,1945],{},"Si un schéma unifilaire et un plan de situation actuels existent :",[937,1947,1948,1954,1960],{},[447,1949,1950,1953],{},[55,1951,1952],{},"Mettre à jour les plans"," — ajouter les nouveaux circuits, positions modifiées",[447,1955,1956,1959],{},[55,1957,1958],{},"Marquer"," ce qui est ancien et ce qui est nouveau",[447,1961,1962,1965],{},[55,1963,1964],{},"Présenter les plans mis à jour"," au contrôleur",[367,1967,1969],{"id":1968},"maisons-sans-plans-avant-1981","Maisons sans plans (avant 1981)",[16,1971,1972,1973,1976],{},"De nombreuses maisons anciennes n'ont ",[55,1974,1975],{},"pas de documentation existante",". Dans ce cas (Art. 9.1.2) :",[937,1978,1979,1985,1991],{},[447,1980,1981,1984],{},[55,1982,1983],{},"Relever l'installation complète"," — y compris les parties inchangées",[447,1986,1987,1990],{},[55,1988,1989],{},"Créer un nouveau schéma unifilaire complet"," — pour toute l'installation",[447,1992,1993,1996],{},[55,1994,1995],{},"Établir un plan de situation"," — dessiner toutes les prises, interrupteurs, points lumineux",[1759,1998,1999],{},[16,2000,2001,2004],{},[55,2002,2003],{},"Attention"," : C'est l'une des raisons les plus fréquentes pour lesquelles les rénovations coûtent nettement plus cher que prévu — l'obligation de documentation pour l'ensemble de l'installation.",[23,2006,2008],{"id":2007},"budget-coûts-typiques","Budget : Coûts typiques",[28,2010,2011,2021],{},[31,2012,2013],{},[34,2014,2015,2018],{},[37,2016,2017],{},"Poste",[37,2019,2020],{},"Coût",[47,2022,2023,2031,2041,2049,2057],{},[34,2024,2025,2028],{},[52,2026,2027],{},"Schéma unifilaire + plan de situation (électricien)",[52,2029,2030],{},"300 € – 600 €",[34,2032,2033,2036],{},[52,2034,2035],{},"Schéma unifilaire + plan de situation (PlanElec)",[52,2037,2038],{},[55,2039,2040],{},"Early Access actuellement gratuit",[34,2042,2043,2046],{},[52,2044,2045],{},"Contrôle RGIE",[52,2047,2048],{},"125 € – 170 €",[34,2050,2051,2054],{},[52,2052,2053],{},"Recontrôle (en cas de défauts)",[52,2055,2056],{},"80 € – 120 €",[34,2058,2059,2062],{},[52,2060,2061],{},"Correction des défauts",[52,2063,2064],{},"500 € – 5 000 €+",[367,2066,2068],{"id":2067},"lavantage-planelec-pour-les-rénovations","L'avantage PlanElec pour les rénovations",[16,2070,2071],{},"Avec PlanElec, vous pouvez :",[444,2073,2074,2079,2084,2090,2096],{},[447,2075,2076],{},[55,2077,2078],{},"Documenter l'installation existante",[447,2080,2081,2083],{},[55,2082,1625],{}," et les faire valider automatiquement",[447,2085,2086,2089],{},[55,2087,2088],{},"Séparer clairement"," ancien et nouveau",[447,2091,2092,2095],{},[55,2093,2094],{},"Exporter le résultat en PDF"," pour le contrôleur",[447,2097,2098,2100],{},[55,2099,2040],{}," ; aucun paiement n'est encore activé",[23,2102,2104],{"id":2103},"checklist-pour-les-rénovateurs","Checklist pour les rénovateurs",[16,2106,2107],{},"Avant le début des travaux :",[444,2109,2112,2121,2127,2133,2139],{"className":2110},[2111],"contains-task-list",[447,2113,2116,2120],{"className":2114},[2115],"task-list-item",[2117,2118],"input",{"disabled":510,"type":2119},"checkbox"," Vérifier : Mes travaux déclenchent-ils un nouveau contrôle ?",[447,2122,2124,2126],{"className":2123},[2115],[2117,2125],{"disabled":510,"type":2119}," Rechercher les plans électriques existants (si disponibles)",[447,2128,2130,2132],{"className":2129},[2115],[2117,2131],{"disabled":510,"type":2119}," Prévoir un budget pour la documentation + le contrôle",[447,2134,2136,2138],{"className":2135},[2115],[2117,2137],{"disabled":510,"type":2119}," Impliquer un électricien à temps (pour l'installation)",[447,2140,2142,2144],{"className":2141},[2115],[2117,2143],{"disabled":510,"type":2119}," Utiliser PlanElec pour la documentation (créer les plans soi-même)",[16,2146,2147],{},"Après la rénovation :",[444,2149,2151,2157,2163,2169],{"className":2150},[2111],[447,2152,2154,2156],{"className":2153},[2115],[2117,2155],{"disabled":510,"type":2119}," Plans mis à jour créés ?",[447,2158,2160,2162],{"className":2159},[2115],[2117,2161],{"disabled":510,"type":2119}," Tous les nouveaux circuits dans le schéma unifilaire ?",[447,2164,2166,2168],{"className":2165},[2115],[2117,2167],{"disabled":510,"type":2119}," Organisme de contrôle contacté ?",[447,2170,2172,2174],{"className":2171},[2115],[2117,2173],{"disabled":510,"type":2119}," Contrôle réussi ?",[23,2176,2178],{"id":2177},"articles-connexes","Articles connexes",[444,2180,2181,2187,2193,2199],{},[447,2182,2183],{},[262,2184,2186],{"href":2185},"\u002Ffr\u002Fblog\u002Fancien-rgie-part-8","L'électricité dans les bâtiments anciens en Belgique : Part 8 du RGIE expliqué",[447,2188,2189],{},[262,2190,2192],{"href":2191},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique ? Comparatif de prix 2026",[447,2194,2195],{},[262,2196,2198],{"href":2197},"\u002Ffr\u002Fblog\u002Fque-verifie-controleur-inspection","Que vérifie le contrôleur lors de l'inspection ?",[447,2200,2201],{},[262,2202,2204],{"href":2203},"\u002Ffr\u002Fblog\u002Fdossier-electrique-vente-immobiliere","Dossier électrique lors de la vente immobilière",[16,2206,2207],{},[262,2208,2209],{"href":1216},"Planifiez votre rénovation conformément au RGIE avec PlanElec →",{"title":487,"searchDepth":488,"depth":488,"links":2211},[2212,2213,2217,2221,2224,2228,2231,2232],{"id":1585,"depth":488,"text":1586},{"id":1596,"depth":488,"text":1597,"children":2214},[2215,2216],{"id":1600,"depth":497,"text":1601},{"id":1690,"depth":497,"text":1691},{"id":1773,"depth":488,"text":1774,"children":2218},[2219,2220],{"id":1787,"depth":497,"text":1788},{"id":1819,"depth":497,"text":1820},{"id":1844,"depth":488,"text":1845,"children":2222},[2223],{"id":1906,"depth":497,"text":1907},{"id":1937,"depth":488,"text":1938,"children":2225},[2226,2227],{"id":1941,"depth":497,"text":1942},{"id":1968,"depth":497,"text":1969},{"id":2007,"depth":488,"text":2008,"children":2229},[2230],{"id":2067,"depth":497,"text":2068},{"id":2103,"depth":488,"text":2104},{"id":2177,"depth":488,"text":2178},"Toute rénovation ne nécessite pas de nouveaux plans électriques. Découvrez quels travaux déclenchent un nouveau contrôle et ce que signifie la règle de contamination.","2026-06-05",{},"\u002Fblog\u002Frenovation-electrical-plans.fr",{"title":1579,"description":2233},"renovation-rgie-plans-electriques","blog\u002Frenovation-electrical-plans.fr",[1240,521,2241,2242,2243,1592,2244,1840,2245,518,519,1241,2246],"rénovation","travaux","plans électriques","règle de contamination","installation existante","contrôle électrique","pskrogmRqJWTAe8uqagWBkG-SWIRTPB01k5T573VlFo",{"id":2249,"title":2250,"articleId":2251,"body":2252,"category":2574,"date":2575,"description":2576,"extension":507,"lastUpdated":2234,"locale":508,"meta":2577,"navigation":510,"path":2578,"publishDate":2575,"readTime":2579,"refreshInterval":913,"seo":2580,"slug":2581,"stem":2582,"tags":2583,"__hash__":2593},"blog\u002Fblog\u002Fdedicated-circuits-appliances.fr.md","Circuit dédié obligatoire : Quels appareils nécessitent leur propre disjoncteur ?","dedicated-circuits-appliances",{"type":9,"value":2253,"toc":2563},[2254,2258,2265,2269,2412,2428,2432,2435,2455,2459,2462,2488,2492,2499,2503,2506,2522,2530,2534,2537,2539,2558],[23,2255,2257],{"id":2256},"oui-certains-appareils-doivent-avoir-leur-propre-circuit","Oui — certains appareils doivent avoir leur propre circuit",[16,2259,2260,2261,2264],{},"Le RGIE (Art. 5.2.1.2) impose pour les ",[55,2262,2263],{},"appareils de forte puissance"," un circuit dédié avec son propre disjoncteur. Ces appareils ne peuvent pas être raccordés à un circuit de prises partagé.",[23,2266,2268],{"id":2267},"quels-appareils-nécessitent-un-circuit-dédié","Quels appareils nécessitent un circuit dédié ?",[28,2270,2271,2286],{},[31,2272,2273],{},[34,2274,2275,2278,2281,2284],{},[37,2276,2277],{},"Appareil",[37,2279,2280],{},"Disjoncteur (MCB)",[37,2282,2283],{},"Câble",[37,2285,1055],{},[47,2287,2288,2304,2320,2336,2349,2362,2377,2397],{},[34,2289,2290,2295,2298,2301],{},[52,2291,2292],{},[55,2293,2294],{},"Cuisinière \u002F plaque de cuisson",[52,2296,2297],{},"32A, bipolaire en monophasé ; en triphasé (3×400V) MCB 3 ou 4 pôles",[52,2299,2300],{},"6 mm² (XVB 3G6)",[52,2302,2303],{},"Raccordement fixe ou Perilex",[34,2305,2306,2311,2314,2317],{},[52,2307,2308],{},[55,2309,2310],{},"Four",[52,2312,2313],{},"25A",[52,2315,2316],{},"4 mm² (XVB 3G4)",[52,2318,2319],{},"Raccordement fixe ou prise dédiée",[34,2321,2322,2327,2330,2333],{},[52,2323,2324],{},[55,2325,2326],{},"Lave-linge",[52,2328,2329],{},"20A",[52,2331,2332],{},"2,5 mm² (XVB 3G2,5)",[52,2334,2335],{},"Prise 16A",[34,2337,2338,2343,2345,2347],{},[52,2339,2340],{},[55,2341,2342],{},"Sèche-linge",[52,2344,2329],{},[52,2346,2332],{},[52,2348,2335],{},[34,2350,2351,2356,2358,2360],{},[52,2352,2353],{},[55,2354,2355],{},"Lave-vaisselle",[52,2357,2329],{},[52,2359,2332],{},[52,2361,2335],{},[34,2363,2364,2370,2372,2374],{},[52,2365,2366,2369],{},[55,2367,2368],{},"Chauffe-eau"," (à partir de 2 600 W de puissance nominale — obligation RGIE)",[52,2371,2329],{},[52,2373,2332],{},[52,2375,2376],{},"Prise 16A ou raccordement fixe",[34,2378,2379,2384,2387,2390],{},[52,2380,2381],{},[55,2382,2383],{},"Borne de recharge",[52,2385,2386],{},"20–40A",[52,2388,2389],{},"4–6 mm²",[52,2391,2392,2393,2396],{},"Raccordement fixe ; en plus obligatoire : RCD 30 mA ",[55,2394,2395],{},"Type B"," (ou Type A-EV avec protection DC 6mA intégrée dans la borne) par point de charge (Art. 7.22.4)",[34,2398,2399,2404,2407,2409],{},[52,2400,2401],{},[55,2402,2403],{},"Pompe à chaleur",[52,2405,2406],{},"20–32A",[52,2408,2389],{},[52,2410,2411],{},"Raccordement fixe",[1759,2413,2414],{},[16,2415,2416,2419,2420,2423,2424,2427],{},[55,2417,2418],{},"Règle générale"," : Tout appareil fixe d'une puissance nominale égale ou supérieure à ",[55,2421,2422],{},"2 600 Watts"," (2,6 kW) doit avoir son propre circuit selon le RGIE (Art. 5.2.1.2). Les lave-linge, sèche-linge et lave-vaisselle doivent être raccordés derrière un ",[55,2425,2426],{},"différentiel 30 mA"," (Art. 4.2.4.3b). Les appareils fixes comme les cuisinières et réfrigérateurs peuvent être raccordés directement derrière le différentiel 300 mA au point d'alimentation.",[23,2429,2431],{"id":2430},"pourquoi-un-circuit-dédié","Pourquoi un circuit dédié ?",[16,2433,2434],{},"Trois raisons pour lesquelles le RGIE impose des circuits dédiés :",[937,2436,2437,2443,2449],{},[447,2438,2439,2442],{},[55,2440,2441],{},"Sécurité"," : Les appareils de forte puissance sollicitent le circuit en permanence près de sa limite. Un circuit partagé peut surchauffer.",[447,2444,2445,2448],{},[55,2446,2447],{},"Disponibilité"," : Si le disjoncteur déclenche, seul l'appareil concerné est coupé — pas toute la cuisine.",[447,2450,2451,2454],{},[55,2452,2453],{},"Protection des câbles"," : La section du câble peut être adaptée exactement à l'appareil.",[23,2456,2458],{"id":2457},"planification-de-la-cuisine-minimum-3-circuits-dédiés","Planification de la cuisine : Minimum 3 circuits dédiés",[16,2460,2461],{},"Une cuisine typique nécessite au minimum :",[444,2463,2464,2470,2476,2482],{},[447,2465,2466,2469],{},[55,2467,2468],{},"1× plaque de cuisson"," (32A, 6 mm²)",[447,2471,2472,2475],{},[55,2473,2474],{},"1× four"," (20A, 4 mm²)",[447,2477,2478,2481],{},[55,2479,2480],{},"1× lave-vaisselle"," (20A, 2,5 mm²)",[447,2483,2484,2487],{},[55,2485,2486],{},"Plus"," : 1–2 circuits de prises généraux pour les petits appareils (cafetière, grille-pain, micro-ondes)",[367,2489,2491],{"id":2490},"lerreur-la-plus-fréquente","L'erreur la plus fréquente",[16,2493,2494,2495,2498],{},"L'infraction RGIE la plus courante en cuisine : ",[55,2496,2497],{},"le lave-vaisselle sur le circuit de prises commun",". L'installateur le branche sur la prise libre la plus proche au lieu de prévoir un circuit dédié. Lors du contrôle, c'est signalé comme défaut.",[23,2500,2502],{"id":2501},"buanderie-local-technique","Buanderie \u002F local technique",[16,2504,2505],{},"Même principe : chaque gros appareil obtient son propre circuit :",[444,2507,2508,2513,2517],{},[447,2509,2510,2512],{},[55,2511,2326],{}," : circuit dédié 20A",[447,2514,2515,2512],{},[55,2516,2342],{},[447,2518,2519,2521],{},[55,2520,2368],{}," : circuit dédié 20A (à partir de 2 600 W — obligation RGIE)",[1759,2523,2524],{},[16,2525,2526,2529],{},[55,2527,2528],{},"Conseil"," : Prévoyez également dans la buanderie un circuit de prises séparé pour le fer à repasser et autres consommateurs.",[23,2531,2533],{"id":2532},"planelec-aide-à-contrôler-les-circuits-dédiés","PlanElec aide à contrôler les circuits dédiés",[16,2535,2536],{},"L'auto-contrôle PlanElec peut signaler, pour les appareils pris en charge, qu'aucun circuit dédié n'est renseigné. L'alerte reste une aide à la planification et ne remplace ni le dimensionnement professionnel ni le contrôle officiel.",[23,2538,2178],{"id":2177},[444,2540,2541,2546,2552],{},[447,2542,2543],{},[262,2544,2545],{"href":565},"Quelle section de câble pour quel disjoncteur ?",[447,2547,2548],{},[262,2549,2551],{"href":2550},"\u002Ffr\u002Fblog\u002F30ma-ddr-par-prise","Ai-je besoin d'un différentiel 30mA par prise ?",[447,2553,2554],{},[262,2555,2557],{"href":2556},"\u002Ffr\u002Fblog\u002Fprises-par-circuit","Combien de prises par circuit ?",[16,2559,2560],{},[262,2561,2562],{"href":1216},"Planifiez vos circuits conformément au RGIE avec PlanElec — gratuit →",{"title":487,"searchDepth":488,"depth":488,"links":2564},[2565,2566,2567,2568,2571,2572,2573],{"id":2256,"depth":488,"text":2257},{"id":2267,"depth":488,"text":2268},{"id":2430,"depth":488,"text":2431},{"id":2457,"depth":488,"text":2458,"children":2569},[2570],{"id":2490,"depth":497,"text":2491},{"id":2501,"depth":488,"text":2502},{"id":2532,"depth":488,"text":2533},{"id":2177,"depth":488,"text":2178},"faq","2026-07-13","Cuisinière, lave-linge, sèche-linge — le RGIE impose un circuit dédié pour certains appareils. Voici la liste complète.",{},"\u002Fblog\u002Fdedicated-circuits-appliances.fr","3 min",{"title":2250,"description":2576},"circuit-dedie-obligatoire-appareils","blog\u002Fdedicated-circuits-appliances.fr",[1240,521,2584,2585,2586,2587,2588,2589,2590,2591,2592,1241,2246],"circuit dédié","circuit individuel","lave-linge","sèche-linge","cuisinière","lave-vaisselle","chauffe-eau","disjoncteur","section câble","YYpzzr-FaIiyDf_6yQ7GxeDb6cjLL1Oppwd9LxqyWj4",{"id":2595,"title":2596,"articleId":2597,"body":2598,"category":906,"date":2765,"description":2766,"extension":507,"lastUpdated":1563,"locale":508,"meta":2767,"navigation":510,"path":2768,"publishDate":2769,"readTime":512,"refreshInterval":1567,"seo":2770,"slug":2771,"stem":2772,"tags":2773,"__hash__":2779},"blog\u002Fblog\u002Fgetting-started-guide.fr.md","Premiers pas avec PlanElec : du plan au premier export","getting-started-guide",{"type":9,"value":2599,"toc":2754},[2600,2606,2610,2617,2620,2624,2630,2633,2637,2640,2643,2647,2650,2653,2656,2660,2663,2669,2673,2679,2682,2686,2689,2692,2696,2701,2707,2711,2737,2740],[16,2601,2602,2603],{},"PlanElec accompagne le projet depuis le plan spatial jusqu'au tableau, au schéma unifilaire et aux documents, en passant par la topologie électrique. Le principe essentiel pour bien débuter est le suivant : ",[55,2604,2605],{},"un symbole sur le plan indique d'abord une position ; son affectation électrique en fait ensuite un élément du schéma.",[23,2607,2609],{"id":2608},"_1-créer-le-projet-le-bâtiment-et-les-étages","1. Créer le projet, le bâtiment et les étages",[16,2611,2612,2613,2616],{},"Après connexion, ouvrez la liste des projets et choisissez ",[55,2614,2615],{},"Créer un projet",". Vous pouvez démarrer avec le parcours guidé, un modèle ou un projet vide. Pour un premier projet, le parcours guidé est recommandé car il détermine la prochaine étape à partir de l'état réel des données.",[16,2618,2619],{},"Créez ensuite le bâtiment et ses étages. Ouvrez les métadonnées du projet et renseignez le nom, l'adresse de l'installation et l'installateur. Ces informations alimenteront les cartouches, le rapport d'auto-contrôle et le dossier.",[23,2621,2623],{"id":2622},"_2-dessiner-le-plan-et-créer-les-pièces","2. Dessiner le plan et créer les pièces",[16,2625,2626,2627,2629],{},"Dans la section ",[55,2628,1300],{},", dessinez les murs extérieurs et intérieurs sous forme de polygone ou de rectangle. Vous pouvez aussi importer un plan existant comme image de référence et le calibrer sur une distance connue.",[16,2631,2632],{},"Lorsque les murs délimitent une surface fermée, PlanElec reconnaît une pièce. Nommez et classez chaque pièce. Cela facilite ensuite le choix des équipements, la vue matériel et le contrôle professionnel.",[23,2634,2636],{"id":2635},"_3-placer-les-équipements-électriques","3. Placer les équipements électriques",[16,2638,2639],{},"Ouvrez la palette et placez les prises, interrupteurs, luminaires, raccordements fixes, boîtes de connexion et le tableau à leur position prévue. Les équipements muraux s'alignent sur le mur, tandis que les luminaires peuvent rester libres dans la pièce.",[16,2641,2642],{},"Dans les pièces appropriées, PlanElec peut proposer des prises, de l'éclairage, un équipement standard ou une grille de spots. Vérifiez chaque proposition en tenant compte des portes, fenêtres, éléments fixes, usages et zones humides. L'automatisation fournit un point de départ modifiable, pas une étude professionnelle terminée.",[23,2644,2646],{"id":2645},"_4-relier-interrupteurs-récepteurs-et-topologie","4. Relier interrupteurs, récepteurs et topologie",[16,2648,2649],{},"Reliez les interrupteurs aux luminaires associés. Une chaîne peut être proposée pour les éléments encore libres d'une pièce. Contrôlez ensuite la liste des composants non connectés.",[16,2651,2652],{},"Affectez les récepteurs au tableau et au circuit appropriés. L'affectation automatique peut regrouper les points d'éclairage et les prises ordinaires et traiter séparément les appareils spéciaux pris en charge. Vérifiez les protections, la phase et les données de câble avant d'accepter la proposition.",[16,2654,2655],{},"Une boîte de connexion ou de dérivation doit être reliée comme un vrai nœud topologique pour diviser le câble en plusieurs segments. La proximité spatiale d'une boîte ne suffit pas pour l'insérer automatiquement dans le chemin électrique.",[23,2657,2659],{"id":2658},"_5-contrôler-les-chemins-de-câble","5. Contrôler les chemins de câble",[16,2661,2662],{},"Pour les équipements connectés, PlanElec peut calculer un trajet de câble le long des murs. Vérifiez le départ, l'arrivée et le parcours, puis ajoutez des points de passage manuels si nécessaire. Une longueur déterminée professionnellement peut remplacer la longueur calculée.",[16,2664,2665,2666,2668],{},"Le type, la section, le mode de pose et la longueur du câble doivent correspondre à l'installation réelle. Le guide ",[262,2667,1408],{"href":1407}," réunit le déroulement pour les récepteurs, les câbles, les circuits et le tableau.",[23,2670,2672],{"id":2671},"_6-remplir-le-tableau-électrique","6. Remplir le tableau électrique",[16,2674,2675,2676,2678],{},"Ouvrez la section ",[55,2677,1333],{},", choisissez le coffret et la configuration des pôles, puis lancez le placement automatique. Les interrupteurs principaux, différentiels et disjoncteurs déjà présents sont disposés sur les rails DIN, avec une réserve de place prévue par défaut.",[16,2680,2681],{},"Contrôlez ensuite la largeur des modules, les groupes protégés et les connexions. Ajoutez les relations manquantes avec l'outil de liaison ou déplacez les modules manuellement. Dans une installation polyphasée, vérifiez également l'aperçu des phases.",[23,2683,2685],{"id":2684},"_7-contrôler-le-schéma-unifilaire-et-lauto-contrôle","7. Contrôler le schéma unifilaire et l'auto-contrôle",[16,2687,2688],{},"Le schéma unifilaire est dérivé de la topologie électrique. Vérifiez que les branches de récepteurs, protections, données de câble et dérivations sont complètes. Si une affectation est incorrecte, corrigez la relation dans le modèle de projet commun, puis contrôlez à nouveau le schéma.",[16,2690,2691],{},"L'auto-contrôle RGIE signale des constats dans les domaines actuellement pris en charge et évaluables à partir des données du projet. L'absence d'erreur ne garantit pas la conformité et ne remplace pas le contrôle officiel.",[23,2693,2695],{"id":2694},"_8-exporter-les-documents","8. Exporter les documents",[16,2697,2626,2698,2700],{},[55,2699,1355],{},", vous pouvez produire en PDF le schéma unifilaire, le plan de situation et le rapport indicatif d'auto-contrôle. Le flux de développement\u002Fpilote ajoute les listes de circuits, de matériel et de câbles ainsi qu'un dossier de travail sélectionnable. Le PDF du tableau n'apparaît que si le feature flag est actif et si le tableau contient des données.",[16,2702,2703,2704,2706],{},"Avant toute transmission, contrôlez les métadonnées, la lisibilité, l'ordre des pages et les constats ouverts. La page ",[262,2705,1458],{"href":1457}," détaille le statut de chaque sortie.",[23,2708,2710],{"id":2709},"liste-de-contrôle","Liste de contrôle",[444,2712,2713,2716,2719,2722,2725,2728,2731,2734],{},[447,2714,2715],{},"Le bâtiment, les étages et les pièces sont entièrement créés.",[447,2717,2718],{},"Tous les équipements électriques se trouvent à la bonne position.",[447,2720,2721],{},"Les récepteurs sont reliés à la topologie, au circuit et au tableau.",[447,2723,2724],{},"Les trajets et longueurs de câble ont été contrôlés.",[447,2726,2727],{},"La chaîne de protection et le placement du tableau sont plausibles.",[447,2729,2730],{},"Le schéma unifilaire et le plan de situation ont été vérifiés visuellement.",[447,2732,2733],{},"Les métadonnées du projet sont complètes pour la version du document.",[447,2735,2736],{},"Les constats et lacunes de couverture ont été compris et évalués.",[16,2738,2739],{},"PlanElec ne remplace ni l'étude et l'exécution professionnelles, ni le contrôle officiel. Faites vérifier le résultat par un électricien qualifié avant les travaux. Seul un organisme de contrôle agréé rend l'évaluation officielle.",[16,2741,2742,2743,2745,2746,2749,2750,2753],{},"Retrouvez d'autres instructions dans la ",[262,2744,1545],{"href":1544}," et l'ensemble du périmètre dans la ",[262,2747,2748],{"href":1539},"vue des fonctionnalités",". Vous pouvez ",[262,2751,2752],{"href":1549},"vous inscrire à PlanElec"," pendant l'Early Access actuel.",{"title":487,"searchDepth":488,"depth":488,"links":2755},[2756,2757,2758,2759,2760,2761,2762,2763,2764],{"id":2608,"depth":488,"text":2609},{"id":2622,"depth":488,"text":2623},{"id":2635,"depth":488,"text":2636},{"id":2645,"depth":488,"text":2646},{"id":2658,"depth":488,"text":2659},{"id":2671,"depth":488,"text":2672},{"id":2684,"depth":488,"text":2685},{"id":2694,"depth":488,"text":2695},{"id":2709,"depth":488,"text":2710},"2026-07-07","Guide pas à pas : créer le projet et ses étages, dessiner le plan de situation, connecter les récepteurs, contrôler le tableau et exporter les PDF.",{},"\u002Fblog\u002Fgetting-started-guide.fr","2026-07-14",{"title":2596,"description":2766},"premiers-pas-planelec","blog\u002Fgetting-started-guide.fr",[2774,2775,2776,519,2777,1573,2778],"premiers pas","onboarding","plan","récepteurs","export","FT8D1G0uzSnK2HE-mVBb0QE0JsXZ7D0Wai8WLpDPFVc",{"id":2781,"title":2782,"articleId":2783,"body":2784,"category":2574,"date":3042,"description":3043,"extension":507,"lastUpdated":2234,"locale":508,"meta":3044,"navigation":510,"path":3045,"publishDate":3042,"readTime":2579,"refreshInterval":913,"seo":3046,"slug":3047,"stem":3048,"tags":3049,"__hash__":3055},"blog\u002Fblog\u002Fsurge-protection-spd-mandatory.fr.md","Parafoudre selon le RGIE — Ce qu'il faut savoir","surge-protection-spd-mandatory",{"type":9,"value":2785,"toc":3033},[2786,2790,2797,2801,2808,2866,2870,2880,2889,2896,2903,2907,2921,2927,2931,2941,2955,2962,2966,3016,3018,3028],[23,2787,2789],{"id":2788},"protection-contre-les-surtensions-dans-le-rgie","Protection contre les surtensions dans le RGIE",[16,2791,2792,2793,2796],{},"Le RGIE prescrit dans l'Art. 4.5.1 comme ",[55,2794,2795],{},"principe général"," que les personnes et les biens doivent être protégés contre les effets nuisibles des surtensions — entre autres les phénomènes atmosphériques et les surtensions de commutation. Toutefois, le RGIE ne contient pas d'obligation explicite pour un type de SPD spécifique (p.ex. « Type 2 »). En pratique, un dispositif de protection contre les surtensions est attendu et recommandé par les organismes de contrôle pour les nouvelles installations.",[23,2798,2800],{"id":2799},"quest-ce-quun-parafoudre","Qu'est-ce qu'un parafoudre ?",[16,2802,2803,2804,2807],{},"Un SPD (Surge Protection Device) protège vos appareils électriques contre les ",[55,2805,2806],{},"pics de surtension"," causés par la foudre, les commutations dans le réseau ou d'autres perturbations. Ces pics peuvent détruire l'électronique sensible comme les ordinateurs, téléviseurs, pompes à chaleur et onduleurs.",[28,2809,2810,2823],{},[31,2811,2812],{},[34,2813,2814,2817,2820],{},[37,2815,2816],{},"Type SPD",[37,2818,2819],{},"Protection contre",[37,2821,2822],{},"Lieu d'installation",[47,2824,2825,2838,2853],{},[34,2826,2827,2832,2835],{},[52,2828,2829],{},[55,2830,2831],{},"Type 1",[52,2833,2834],{},"Foudre directe",[52,2836,2837],{},"Au raccordement principal (uniquement avec paratonnerre externe)",[34,2839,2840,2845,2848],{},[52,2841,2842],{},[55,2843,2844],{},"Type 2",[52,2846,2847],{},"Surtension indirecte",[52,2849,2850],{},[55,2851,2852],{},"Au tableau principal — recommandé",[34,2854,2855,2860,2863],{},[52,2856,2857],{},[55,2858,2859],{},"Type 3",[52,2861,2862],{},"Surtension résiduelle",[52,2864,2865],{},"À la prise (protection fine, optionnel)",[23,2867,2869],{"id":2868},"où-installer-le-spd","Où installer le SPD ?",[16,2871,2872,2873,2876,2877,583],{},"Le SPD Type 2 s'installe dans le tableau de distribution. Une variante courante est ",[55,2874,2875],{},"après le différentiel principal"," (DDR) et ",[55,2878,2879],{},"avant les circuits de départ",[2881,2882,2887],"pre",{"className":2883,"code":2885,"language":2886},[2884],"language-text","Réseau → Interrupteur principal → Différentiel principal (300mA) → SPD Type 2 → Différentiels de groupe → Disjoncteurs\n","text",[576,2888,2885],{"__ignoreMap":487},[16,2890,2891,2892,2895],{},"Le SPD peut aussi être installé directement après l'interrupteur principal, ",[55,2893,2894],{},"avant"," le différentiel principal, avec son propre fusible de protection — selon les prescriptions du fabricant et le concept d'installation.",[16,2897,2898,2899,2902],{},"Dans le schéma unifilaire, le SPD est représenté comme une dérivation dédiée, protégée par un disjoncteur dédié (typiquement 20A). ",[55,2900,2901],{},"Important"," : Le fusible de protection maximal est prescrit par le fabricant du SPD et n'est pas librement choisi. Certains SPD nécessitent un fusible à cartouche (gL\u002FgG) au lieu d'un disjoncteur.",[23,2904,2906],{"id":2905},"cela-sapplique-t-il-aux-installations-existantes","Cela s'applique-t-il aux installations existantes ?",[16,2908,2909,2912,2913,2916,2917,2920],{},[55,2910,2911],{},"Non"," — pour les installations existantes contrôlées avant la révision du RGIE de 2020, il n'y a ",[55,2914,2915],{},"pas d'obligation de mise en conformité rétroactive"," (Part 8). Lors du prochain contrôle périodique, l'absence de SPD ",[55,2918,2919],{},"n'est pas"," considérée comme un défaut.",[16,2922,2923,2926],{},[55,2924,2925],{},"Néanmoins recommandé"," : Le coût d'un module SPD (50–150 €) est minime par rapport aux dommages qu'une surtension peut causer à votre électronique (téléviseur, routeur, pompe à chaleur — facilement plusieurs milliers d'euros).",[23,2928,2930],{"id":2929},"spd-et-panneaux-photovoltaïques-pv","SPD et panneaux photovoltaïques (PV)",[16,2932,2933,2934,2937,2938,583],{},"Si vous avez une ",[55,2935,2936],{},"installation PV",", vous avez besoin d'une protection contre les surtensions des ",[55,2939,2940],{},"deux côtés",[444,2942,2943,2949],{},[447,2944,2945,2948],{},[55,2946,2947],{},"Côté AC"," (courant alternatif) : SPD Type 2 dans le tableau principal — comme décrit ci-dessus",[447,2950,2951,2954],{},[55,2952,2953],{},"Côté DC"," (courant continu) : SPD Type 2 à l'onduleur — protège les modules et l'onduleur contre les dommages de foudre. Le RGIE (Chapitre 7.112) n'impose pas explicitement de SPD côté DC pour les installations PV domestiques ; un SPD DC à l'onduleur est néanmoins vivement recommandé par les règles de l'art et les prescriptions du fabricant, en particulier en cas de longs câbles DC ou de câblage passant sur le toit (risque accru de foudre)",[1759,2956,2957],{},[16,2958,2959,2961],{},[55,2960,2901],{}," : De nombreux onduleurs disposent déjà d'un SPD DC intégré. Consultez la fiche technique de votre onduleur.",[23,2963,2965],{"id":2964},"combien-coûte-la-protection-contre-les-surtensions","Combien coûte la protection contre les surtensions ?",[28,2967,2968,2977],{},[31,2969,2970],{},[34,2971,2972,2975],{},[37,2973,2974],{},"Composant",[37,2976,2020],{},[47,2978,2979,2987,2995,3003],{},[34,2980,2981,2984],{},[52,2982,2983],{},"Module SPD Type 2 (monophasé)",[52,2985,2986],{},"50 € – 80 €",[34,2988,2989,2992],{},[52,2990,2991],{},"Module SPD Type 2 (triphasé)",[52,2993,2994],{},"80 € – 150 €",[34,2996,2997,3000],{},[52,2998,2999],{},"Installation par électricien",[52,3001,3002],{},"50 € – 100 €",[34,3004,3005,3011],{},[52,3006,3007,3010],{},[55,3008,3009],{},"Protection"," : électronique du ménage",[52,3012,3013],{},[55,3014,3015],{},"5 000 € – 20 000 €+",[23,3017,2178],{"id":2177},[444,3019,3020,3024],{},[447,3021,3022],{},[262,3023,2551],{"href":2550},[447,3025,3026],{},[262,3027,2198],{"href":2197},[16,3029,3030],{},[262,3031,3032],{"href":1216},"Créez votre schéma unifilaire conforme au RGIE avec SPD — gratuit →",{"title":487,"searchDepth":488,"depth":488,"links":3034},[3035,3036,3037,3038,3039,3040,3041],{"id":2788,"depth":488,"text":2789},{"id":2799,"depth":488,"text":2800},{"id":2868,"depth":488,"text":2869},{"id":2905,"depth":488,"text":2906},{"id":2929,"depth":488,"text":2930},{"id":2964,"depth":488,"text":2965},{"id":2177,"depth":488,"text":2178},"2026-07-06","Le RGIE prescrit une protection générale contre les surtensions (Art. 4.5.1), sans imposer un type de SPD spécifique. Découvrez ce que le RGIE exige réellement.",{},"\u002Fblog\u002Fsurge-protection-spd-mandatory.fr",{"title":2782,"description":3043},"parafoudre-obligatoire-rgie","blog\u002Fsurge-protection-spd-mandatory.fr",[1240,521,3050,3051,3052,3053,2844,3054,1573,1241,2246],"parafoudre","SPD","Surge Protection Device","protection contre la foudre","nouvelle installation","On8OPK7EZxYjz0g5Z5oGBQm1odLo7eKSjY8WvXROgfw",{"id":3057,"title":3058,"articleId":3059,"body":3060,"category":906,"date":3599,"description":3600,"extension":507,"lastUpdated":2234,"locale":508,"meta":3601,"navigation":510,"path":3602,"publishDate":3599,"readTime":3603,"refreshInterval":913,"seo":3604,"slug":3605,"stem":3606,"tags":3607,"__hash__":3611},"blog\u002Fblog\u002Fproperty-sale-electrical-dossier.fr.md","Dossier électrique lors de la vente immobilière : Ce que le notaire et l'acheteur attendent","property-sale-electrical-dossier",{"type":9,"value":3061,"toc":3577},[3062,3066,3073,3077,3080,3084,3091,3115,3128,3132,3139,3153,3160,3164,3171,3185,3189,3200,3204,3211,3215,3222,3233,3237,3243,3281,3292,3296,3303,3377,3381,3388,3392,3399,3419,3429,3433,3436,3478,3482,3485,3509,3513,3516,3555,3557,3572],[23,3063,3065],{"id":3064},"le-dossier-électrique-obligatoire-lors-de-la-vente","Le dossier électrique — obligatoire lors de la vente",[16,3067,3068,3069,3072],{},"Si vous vendez un bien immobilier en Belgique, vous avez besoin d'un ",[55,3070,3071],{},"dossier électrique"," complet. Sans ce dossier, le notaire ne peut pas authentifier l'acte de vente. Ce guide vous explique les documents requis, comment vous préparer et ce qui se passe en cas de non-conformité.",[23,3074,3076],{"id":3075},"quels-documents-le-notaire-exige-t-il","Quels documents le notaire exige-t-il ?",[16,3078,3079],{},"Le notaire exige un dossier électrique complet composé de trois éléments légalement obligatoires :",[367,3081,3083],{"id":3082},"_1-rapport-de-contrôle","1. Rapport de contrôle",[16,3085,3086,3087,3090],{},"Le rapport de contrôle est établi par un ",[55,3088,3089],{},"organisme de contrôle agréé"," (p. ex. BTV, Vinçotte, AIB). Il documente :",[444,3092,3093,3096,3099,3108],{},[447,3094,3095],{},"Date et résultat de l'inspection",[447,3097,3098],{},"Défauts et infractions constatés",[447,3100,3101,3102,1546,3105],{},"Statut de conformité : ",[55,3103,3104],{},"conforme",[55,3106,3107],{},"non conforme",[447,3109,3110,3111,3114],{},"Durée de validité : ",[55,3112,3113],{},"25 ans"," pour une installation conforme",[1759,3116,3117],{},[16,3118,3119,3121,3122,3124,3125,567],{},[55,3120,2901],{}," : Le rapport de contrôle ne peut pas avoir plus de ",[55,3123,3113],{}," lors de la vente. En cas d'installation non conforme, le nouveau propriétaire doit faire corriger les défauts dans un délai de ",[55,3126,3127],{},"18 mois",[367,3129,3131],{"id":3130},"_2-schéma-unifilaire","2. Schéma unifilaire",[16,3133,3134,3135,3138],{},"Le schéma unifilaire montre la ",[55,3136,3137],{},"structure électrique"," de votre installation :",[444,3140,3141,3144,3147,3150],{},[447,3142,3143],{},"Tous les circuits avec numérotation",[447,3145,3146],{},"Disjoncteurs (MCB) et différentiels (RCD)",[447,3148,3149],{},"Sections et types de câbles",[447,3151,3152],{},"Consommateurs par circuit",[16,3154,3155,3156,3159],{},"Le schéma doit refléter l'",[55,3157,3158],{},"état actuel"," de l'installation — pas les plans de construction originaux.",[367,3161,3163],{"id":3162},"_3-plan-de-situation","3. Plan de situation",[16,3165,3166,3167,3170],{},"Le plan de situation montre la ",[55,3168,3169],{},"disposition spatiale"," de tous les composants électriques :",[444,3172,3173,3176,3179,3182],{},[447,3174,3175],{},"Position des prises, interrupteurs et points lumineux",[447,3177,3178],{},"Emplacement du tableau de distribution",[447,3180,3181],{},"Tracés des câbles (si connus)",[447,3183,3184],{},"Installation de mise à la terre",[367,3186,3188],{"id":3187},"note-concernant-lattestation-de-conformité","Note concernant l'attestation de conformité",[16,3190,3191,3192,3195,3196,3199],{},"Pour les installations plus récentes (après 1981) ou après une rénovation complète, il existe souvent une ",[55,3193,3194],{},"attestation de conformité"," de l'installateur d'origine. Celle-ci n'est cependant ",[55,3197,3198],{},"pas un élément légalement obligatoire"," du dossier électrique lors de la vente immobilière. Les seuls documents légalement obligatoires sont le rapport de contrôle de l'organisme de contrôle agréé, le schéma unifilaire et le plan de situation. L'attestation de conformité est un document complémentaire qui peut être remis s'il est disponible.",[23,3201,3203],{"id":3202},"que-se-passe-t-il-en-cas-dinstallation-non-conforme","Que se passe-t-il en cas d'installation non conforme ?",[16,3205,3206,3207,3210],{},"Une installation non conforme ne signifie ",[55,3208,3209],{},"pas"," que vous ne pouvez pas vendre le bien. Cependant, des règles particulières s'appliquent :",[367,3212,3214],{"id":3213},"la-règle-des-18-mois","La règle des 18 mois",[16,3216,3217,3218,3221],{},"Si le rapport de contrôle mentionne des défauts, l'",[55,3219,3220],{},"acheteur dispose de 18 mois à partir de la date de l'acte notarié"," pour :",[937,3223,3224,3227,3230],{},[447,3225,3226],{},"Corriger les défauts constatés",[447,3228,3229],{},"Faire effectuer un nouveau contrôle",[447,3231,3232],{},"Obtenir un rapport de conformité",[367,3234,3236],{"id":3235},"négociation-du-prix-en-cas-de-défauts","Négociation du prix en cas de défauts",[16,3238,3239,3240,583],{},"En pratique, une installation non conforme entraîne presque toujours une ",[55,3241,3242],{},"réduction de prix",[28,3244,3245,3255],{},[31,3246,3247],{},[34,3248,3249,3252],{},[37,3250,3251],{},"Type de défauts",[37,3253,3254],{},"Réduction typique",[47,3256,3257,3265,3273],{},[34,3258,3259,3262],{},[52,3260,3261],{},"Défauts mineurs (couvercles manquants, étiquetage)",[52,3263,3264],{},"500 € – 1 500 €",[34,3266,3267,3270],{},[52,3268,3269],{},"Défauts moyens (différentiels manquants, mise à la terre)",[52,3271,3272],{},"1 500 € – 3 000 €",[34,3274,3275,3278],{},[52,3276,3277],{},"Défauts graves (installation vétuste, risques de sécurité)",[52,3279,3280],{},"3 000 € – 5 000 €+",[1759,3282,3283],{},[16,3284,3285,3287,3288,3291],{},[55,3286,2528],{}," : Il est presque toujours avantageux de corriger les défauts ",[55,3289,3290],{},"avant la vente",". Les coûts réels de réparation sont souvent nettement inférieurs à la réduction de prix lors de la négociation.",[23,3293,3295],{"id":3294},"calendrier-quand-commencer-la-préparation","Calendrier : Quand commencer la préparation ?",[16,3297,3298,3299,3302],{},"Prévoyez au minimum ",[55,3300,3301],{},"6 à 8 semaines"," avant le début de la mise en vente :",[28,3304,3305,3315],{},[31,3306,3307],{},[34,3308,3309,3312],{},[37,3310,3311],{},"Moment",[37,3313,3314],{},"Action",[47,3316,3317,3327,3337,3347,3357,3367],{},[34,3318,3319,3324],{},[52,3320,3321],{},[55,3322,3323],{},"8 semaines avant",[52,3325,3326],{},"Vérifier les documents existants — avez-vous un schéma unifilaire et un plan de situation ?",[34,3328,3329,3334],{},[52,3330,3331],{},[55,3332,3333],{},"6–7 semaines avant",[52,3335,3336],{},"Faire établir les plans manquants — possible en quelques heures avec PlanElec",[34,3338,3339,3344],{},[52,3340,3341],{},[55,3342,3343],{},"5–6 semaines avant",[52,3345,3346],{},"Contacter l'organisme de contrôle (délais d'attente : 2–4 semaines)",[34,3348,3349,3354],{},[52,3350,3351],{},[55,3352,3353],{},"3–4 semaines avant",[52,3355,3356],{},"Faire réaliser l'inspection",[34,3358,3359,3364],{},[52,3360,3361],{},[55,3362,3363],{},"2–3 semaines avant",[52,3365,3366],{},"En cas de défauts : réparer et éventuellement recontrôler",[34,3368,3369,3374],{},[52,3370,3371],{},[55,3372,3373],{},"Début de vente",[52,3375,3376],{},"Remettre le dossier complet à l'agent immobilier\u002Fnotaire",[367,3378,3380],{"id":3379},"tenir-compte-des-délais-dattente","Tenir compte des délais d'attente",[16,3382,3383,3384,3387],{},"Les organismes de contrôle ont souvent ",[55,3385,3386],{},"2 à 4 semaines de délai",". En haute saison (printemps\u002Fété), cela peut être plus long. Planifiez donc à temps.",[23,3389,3391],{"id":3390},"problèmes-courants-avec-les-biens-anciens","Problèmes courants avec les biens anciens",[16,3393,3394,3395,3398],{},"Pour les bâtiments construits ",[55,3396,3397],{},"avant 1981",", il y a souvent des défis supplémentaires :",[444,3400,3401,3407,3413],{},[447,3402,3403,3406],{},[55,3404,3405],{},"Pas de plans existants"," : Le schéma unifilaire et le plan de situation doivent être entièrement recréés",[447,3408,3409,3412],{},[55,3410,3411],{},"Installation vétuste"," : Ancien câblage, mise à la terre manquante, pas de différentiels",[447,3414,3415,3418],{},[55,3416,3417],{},"Part 8 RGIE"," : Des exigences assouplies s'appliquent partiellement aux installations existantes — mais uniquement pour les parties inchangées",[1759,3420,3421],{},[16,3422,3423,3425,3426,567],{},[55,3424,2003],{}," : Dès que vous avez modifié même une partie de l'installation (p. ex. nouvelles prises dans la salle de bain), le RGIE actuel s'applique à ",[55,3427,3428],{},"toute la partie modifiée",[23,3430,3432],{"id":3431},"combien-coûte-le-dossier-électrique","Combien coûte le dossier électrique ?",[16,3434,3435],{},"Les coûts se composent de plusieurs éléments :",[28,3437,3438,3447],{},[31,3439,3440],{},[34,3441,3442,3445],{},[37,3443,3444],{},"Prestation",[37,3446,2020],{},[47,3448,3449,3456,3464,3471],{},[34,3450,3451,3453],{},[52,3452,2027],{},[52,3454,3455],{},"269 € – 600 €",[34,3457,3458,3460],{},[52,3459,2035],{},[52,3461,3462],{},[55,3463,2040],{},[34,3465,3466,3469],{},[52,3467,3468],{},"Contrôle RGIE (inspection)",[52,3470,2048],{},[34,3472,3473,3476],{},[52,3474,3475],{},"Correction des défauts (si nécessaire)",[52,3477,2064],{},[367,3479,3481],{"id":3480},"planelec-lalternative-rapide-et-économique","PlanElec : L'alternative rapide et économique",[16,3483,3484],{},"Au lieu de confier la création des plans à un électricien pour 269–600 €, vous pouvez créer vos plans vous-même avec PlanElec :",[444,3486,3487,3493,3498,3504],{},[447,3488,3489,3492],{},[55,3490,3491],{},"Bibliothèque de symboles électriques"," et auto-contrôle indicatif",[447,3494,3495,3497],{},[55,3496,159],{}," directement à partir du plan d'étage",[447,3499,3500,3503],{},[55,3501,3502],{},"Export PDF"," comme base pour la vérification professionnelle",[447,3505,3506,3508],{},[55,3507,2040],{}," — aucun paiement n'est encore activé",[23,3510,3512],{"id":3511},"checklist-pour-les-vendeurs","Checklist pour les vendeurs",[16,3514,3515],{},"Avant d'aller chez le notaire, vérifiez :",[444,3517,3519,3525,3531,3537,3543,3549],{"className":3518},[2111],[447,3520,3522,3524],{"className":3521},[2115],[2117,3523],{"disabled":510,"type":2119}," Rapport de contrôle présent et valide (max. 25 ans) ?",[447,3526,3528,3530],{"className":3527},[2115],[2117,3529],{"disabled":510,"type":2119}," Schéma unifilaire à jour et complet ?",[447,3532,3534,3536],{"className":3533},[2115],[2117,3535],{"disabled":510,"type":2119}," Plan de situation présent ?",[447,3538,3540,3542],{"className":3539},[2115],[2117,3541],{"disabled":510,"type":2119}," Tous les circuits correctement étiquetés ?",[447,3544,3546,3548],{"className":3545},[2115],[2117,3547],{"disabled":510,"type":2119}," Différentiels présents et fonctionnels ?",[447,3550,3552,3554],{"className":3551},[2115],[2117,3553],{"disabled":510,"type":2119}," Installation de mise à la terre vérifiée ?",[23,3556,2178],{"id":2177},[444,3558,3559,3563,3568],{},[447,3560,3561],{},[262,3562,2192],{"href":2191},[447,3564,3565],{},[262,3566,3567],{"href":856},"Contrôle électrique en Belgique — ce qu'il faut savoir",[447,3569,3570],{},[262,3571,2198],{"href":2197},[16,3573,3574],{},[262,3575,3576],{"href":1216},"Préparez le schéma unifilaire et le plan de situation avec PlanElec, puis faites vérifier le dossier par un professionnel →",{"title":487,"searchDepth":488,"depth":488,"links":3578},[3579,3580,3586,3590,3593,3594,3597,3598],{"id":3064,"depth":488,"text":3065},{"id":3075,"depth":488,"text":3076,"children":3581},[3582,3583,3584,3585],{"id":3082,"depth":497,"text":3083},{"id":3130,"depth":497,"text":3131},{"id":3162,"depth":497,"text":3163},{"id":3187,"depth":497,"text":3188},{"id":3202,"depth":488,"text":3203,"children":3587},[3588,3589],{"id":3213,"depth":497,"text":3214},{"id":3235,"depth":497,"text":3236},{"id":3294,"depth":488,"text":3295,"children":3591},[3592],{"id":3379,"depth":497,"text":3380},{"id":3390,"depth":488,"text":3391},{"id":3431,"depth":488,"text":3432,"children":3595},[3596],{"id":3480,"depth":497,"text":3481},{"id":3511,"depth":488,"text":3512},{"id":2177,"depth":488,"text":2178},"2026-06-29","Lors de la vente d'un bien immobilier en Belgique, un dossier électrique complet est obligatoire. Découvrez les documents exigés par le notaire et comment vous préparer.",{},"\u002Fblog\u002Fproperty-sale-electrical-dossier.fr","9 min",{"title":3058,"description":3600},"dossier-electrique-vente-immobiliere","blog\u002Fproperty-sale-electrical-dossier.fr",[1240,521,3608,3071,3609,518,519,3194,3610,1241,2246],"vente immobilière","rapport de contrôle","notaire","cou7SdlHyWhKPznVyDR7j-bHsqK_SryWHSn9Rx-lTbs",{"id":3613,"title":3614,"articleId":3615,"body":3616,"category":906,"date":4280,"description":4281,"extension":507,"lastUpdated":2234,"locale":508,"meta":4282,"navigation":510,"path":4283,"publishDate":4280,"readTime":512,"refreshInterval":913,"seo":4284,"slug":4285,"stem":4286,"tags":4287,"__hash__":4295},"blog\u002Fblog\u002Ftop-10-arei-violations.fr.md","Les 10 infractions RGIE les plus fréquentes : Identifier, éviter et corriger","top-10-arei-violations",{"type":9,"value":3617,"toc":4217},[3618,3621,3624,3627,3631,3637,3641,3644,3648,3655,3659,3670,3674,3677,3679,3683,3688,3691,3700,3703,3706,3709,3723,3726,3732,3734,3738,3743,3746,3749,3752,3755,3758,3772,3775,3778,3780,3784,3789,3792,3799,3802,3805,3808,3819,3822,3825,3827,3831,3836,3839,3842,3845,3848,3851,3865,3868,3871,3873,3877,3882,3885,3888,3891,3898,3901,3969,3980,3983,3986,3988,3992,3997,4000,4007,4010,4013,4016,4027,4030,4033,4035,4039,4044,4047,4054,4057,4060,4063,4074,4077,4080,4082,4086,4091,4094,4097,4100,4103,4106,4117,4120,4123,4125,4129,4134,4137,4140,4143,4146,4149,4160,4163,4166,4168,4172,4175,4177,4182,4207],[12,3619,3614],{"id":3620},"les-10-infractions-rgie-les-plus-fréquentes-identifier-éviter-et-corriger",[16,3622,3623],{},"Lors des contrôles électriques en Belgique, les mêmes infractions reviennent sans cesse. Environ 40 % de tous les contrôles sont négatifs — et les raisons sont souvent identiques. Dans ce guide, nous présentons les dix infractions RGIE les plus fréquentes, expliquons pourquoi elles posent problème et montrons comment les corriger.",[3625,3626],"hr",{},[23,3628,3630],{"id":3629},"_1-différentiel-absent-ou-inadéquat","1. Différentiel absent ou inadéquat",[16,3632,3633,3636],{},[55,3634,3635],{},"Article RGIE :"," Art. 4.2.4.3 (RCD principal) \u002F Art. 4.2.4.3b (obligation différentiel 30 mA par groupe)",[367,3638,3640],{"id":3639},"description","Description",[16,3642,3643],{},"Le défaut le plus fréquent : un différentiel (RCD) absent ou mal dimensionné. Le RGIE prescrit que la plupart des circuits terminaux (en particulier les prises, l'éclairage, la salle de bains, les lave-linge\u002Flave-vaisselle) doivent être protégés par un différentiel de 30 mA.",[367,3645,3647],{"id":3646},"pourquoi-cest-un-problème","Pourquoi c'est un problème",[16,3649,3650,3651,3654],{},"Le différentiel est la protection des personnes la plus importante dans une installation électrique. Il détecte les courants de fuite (par ex. quand du courant traverse le corps humain) et coupe en quelques millisecondes. Sans différentiel, il y a ",[55,3652,3653],{},"danger de mort"," en cas de défaut d'isolement.",[367,3656,3658],{"id":3657},"comment-corriger","Comment corriger",[444,3660,3661,3664,3667],{},[447,3662,3663],{},"Ajouter un RCD 30 mA (Type A) pour la plupart des circuits. Pour les bornes de recharge et PV avec onduleur sans transformateur, le Type B (ou équivalent) est requis — le Type A ne suffit pas pour tous les circuits.",[447,3665,3666],{},"Maximum 8 circuits terminaux par RCD 30 mA (RGIE Art. 4.2.4.3b)",[447,3668,3669],{},"En complément : RCD principal 300 mA (Type A-S, sélectif) comme protection principale",[367,3671,3673],{"id":3672},"coûts-typiques","Coûts typiques",[16,3675,3676],{},"100-200 € par RCD (matériel + installation par électricien)",[3625,3678],{},[23,3680,3682],{"id":3681},"_2-plans-électriques-absents-ou-obsolètes","2. Plans électriques absents ou obsolètes",[16,3684,3685,3687],{},[55,3686,3635],{}," Art. 9.1.2 Nr. 1 (schéma unifilaire), Art. 9.1.2 Nr. 2 (plan de situation)",[367,3689,3640],{"id":3690},"description-1",[16,3692,3693,3694,3696,3697,3699],{},"Le RGIE exige un ",[55,3695,518],{}," et un ",[55,3698,519],{}," à jour pour toute installation électrique. Souvent, ces plans manquent complètement ou ne reflètent pas l'état actuel de l'installation — par exemple parce que des circuits ont été ajoutés ou modifiés après la construction.",[367,3701,3647],{"id":3702},"pourquoi-cest-un-problème-1",[16,3704,3705],{},"Sans plans actuels, ni le contrôleur ni un électricien ne peut évaluer l'installation en toute sécurité. En cas d'urgence (incendie, accident), il manque la documentation indiquant quel interrupteur alimente quelle zone.",[367,3707,3658],{"id":3708},"comment-corriger-1",[444,3710,3711,3714,3717],{},[447,3712,3713],{},"Établir ou mettre à jour le schéma unifilaire et le plan de situation",[447,3715,3716],{},"Documenter tous les circuits, disjoncteurs, RCD et consommateurs",[447,3718,3719,3720],{},"Les plans doivent montrer l'",[55,3721,3722],{},"état réel actuel",[367,3724,3673],{"id":3725},"coûts-typiques-1",[16,3727,3728,3729],{},"150-400 € chez un électricien — ou ",[55,3730,3731],{},"gratuitement avec PlanElec",[3625,3733],{},[23,3735,3737],{"id":3736},"_3-mise-à-la-terre-défectueuse","3. Mise à la terre défectueuse",[16,3739,3740,3742],{},[55,3741,3635],{}," Art. 4.2.3",[367,3744,3640],{"id":3745},"description-2",[16,3747,3748],{},"La mise à la terre est le filet de sécurité de l'installation électrique. Une résistance de terre supérieure à 30 Ohm — le seuil réglementaire selon l'Art. 4.2.4.3b, au-delà duquel des exigences renforcées s'appliquent (entre autres au moins deux RCD 30 mA, max. 16 prises par RCD) — ou une mise à la terre complètement absente constitue un défaut grave. Les connexions desserrées ou les conducteurs de terre corrodés sont également contestés.",[367,3750,3647],{"id":3751},"pourquoi-cest-un-problème-2",[16,3753,3754],{},"Sans mise à la terre fonctionnelle, des boîtiers métalliques peuvent être sous tension sans que le différentiel ne se déclenche. Cela crée un piège mortel invisible.",[367,3756,3658],{"id":3757},"comment-corriger-2",[444,3759,3760,3763,3766,3769],{},[447,3761,3762],{},"Faire mesurer la résistance de terre",[447,3764,3765],{},"Si >30 Ohm : ajouter des électrodes de terre supplémentaires ou renouveler les existantes",[447,3767,3768],{},"Vérifier toutes les connexions de terre et les resserrer si nécessaire",[447,3770,3771],{},"Contrôler la corrosion du conducteur de terre",[367,3773,3673],{"id":3774},"coûts-typiques-2",[16,3776,3777],{},"200-500 € (selon les travaux nécessaires pour de nouvelles électrodes)",[3625,3779],{},[23,3781,3783],{"id":3782},"_4-interrupteur-principal-absent","4. Interrupteur principal absent",[16,3785,3786,3788],{},[55,3787,3635],{}," Art. 5.3.5.1b (interrupteur-sectionneur principal)",[367,3790,3640],{"id":3791},"description-3",[16,3793,3794,3795,3798],{},"Toute installation électrique doit disposer d'un ",[55,3796,3797],{},"interrupteur principal omnipolaire"," permettant de mettre toute l'installation hors tension. L'interrupteur principal doit être d'au moins 40A (pour les habitations standard).",[367,3800,3647],{"id":3801},"pourquoi-cest-un-problème-3",[16,3803,3804],{},"En cas d'urgence, toute l'installation doit pouvoir être coupée d'un seul geste — par exemple en cas d'incendie, d'inondation ou d'accident. L'absence d'interrupteur principal peut coûter des secondes vitales.",[367,3806,3658],{"id":3807},"comment-corriger-3",[444,3809,3810,3813,3816],{},[447,3811,3812],{},"Installer un interrupteur principal omnipolaire ≥40A avant le premier RCD",[447,3814,3815],{},"L'interrupteur doit être facilement accessible (tableau de distribution)",[447,3817,3818],{},"Pour installation triphasée : utiliser un interrupteur principal 4 pôles",[367,3820,3673],{"id":3821},"coûts-typiques-3",[16,3823,3824],{},"80-150 € (matériel + installation)",[3625,3826],{},[23,3828,3830],{"id":3829},"_5-zones-salle-de-bains-non-respectées","5. Zones salle de bains non respectées",[16,3832,3833,3835],{},[55,3834,3635],{}," Art. 7.1",[367,3837,3640],{"id":3838},"description-4",[16,3840,3841],{},"Le RGIE définit des zones de protection dans la salle de bains (Zone 0, 1, 2 et 3), dans lesquelles seuls certains appareils électriques sont autorisés. Infractions fréquentes : prises dans la zone 0 ou 1, protection contre les éclaboussures manquante, interrupteurs trop proches de la baignoire ou de la douche.",[367,3843,3647],{"id":3844},"pourquoi-cest-un-problème-4",[16,3846,3847],{},"L'eau et l'électricité forment une combinaison mortelle. Les zones de salle de bains garantissent que les appareils électriques maintiennent une distance de sécurité suffisante par rapport aux sources d'eau.",[367,3849,3658],{"id":3850},"comment-corriger-4",[444,3852,3853,3856,3859,3862],{},[447,3854,3855],{},"Déplacer prises et interrupteurs hors des zones 0 et 1 (minimum 60 cm de la baignoire\u002Fdouche)",[447,3857,3858],{},"En zone 2 : uniquement des appareils IPX4 (protection contre les éclaboussures)",[447,3860,3861],{},"Protéger tous les circuits salle de bains par un RCD 30 mA",[447,3863,3864],{},"Pas de boîtes de dérivation en zone 0 ou 1",[367,3866,3673],{"id":3867},"coûts-typiques-4",[16,3869,3870],{},"200-600 € (selon l'ampleur du déplacement)",[3625,3872],{},[23,3874,3876],{"id":3875},"_6-section-de-câble-trop-faible-pour-le-disjoncteur","6. Section de câble trop faible pour le disjoncteur",[16,3878,3879,3881],{},[55,3880,3635],{}," Art. 4.4.1 (protection contre les surintensités) \u002F Art. 5.2.1.2 (choix des canalisations électriques)",[367,3883,3640],{"id":3884},"description-5",[16,3886,3887],{},"Le disjoncteur (MCB) doit correspondre à la section du câble. Une combinaison fréquente : disjoncteur 20A sur un câble de 1.5 mm² (qui ne supporte que 16A). Le disjoncteur ne protège alors plus le câble contre la surcharge.",[367,3889,3647],{"id":3890},"pourquoi-cest-un-problème-5",[16,3892,3893,3894,3897],{},"Quand un câble transporte plus de courant qu'il ne peut supporter, il s'échauffe et peut provoquer des incendies. Le disjoncteur doit ",[55,3895,3896],{},"toujours être inférieur ou égal"," à la capacité du câble.",[367,3899,3658],{"id":3900},"comment-corriger-5",[28,3902,3903,3916],{},[31,3904,3905],{},[34,3906,3907,3910,3913],{},[37,3908,3909],{},"Section de câble",[37,3911,3912],{},"Fusible max. (gG)",[37,3914,3915],{},"Disjoncteur max.",[47,3917,3918,3929,3938,3947,3958],{},[34,3919,3920,3923,3926],{},[52,3921,3922],{},"1.5 mm²",[52,3924,3925],{},"10A",[52,3927,3928],{},"16A",[34,3930,3931,3934,3936],{},[52,3932,3933],{},"2.5 mm²",[52,3935,3928],{},[52,3937,2329],{},[34,3939,3940,3943,3945],{},[52,3941,3942],{},"4 mm²",[52,3944,2329],{},[52,3946,2313],{},[34,3948,3949,3952,3955],{},[52,3950,3951],{},"6 mm²",[52,3953,3954],{},"32A",[52,3956,3957],{},"40A",[34,3959,3960,3963,3966],{},[52,3961,3962],{},"10 mm²",[52,3964,3965],{},"50A",[52,3967,3968],{},"63A",[444,3970,3971,3977],{},[447,3972,3973,3974],{},"Réduire le disjoncteur à la valeur correcte ",[55,3975,3976],{},"ou",[447,3978,3979],{},"Remplacer le câble par une section plus grande",[367,3981,3673],{"id":3982},"coûts-typiques-5",[16,3984,3985],{},"20-50 € (remplacement du disjoncteur seul) à 200-500 € (remplacement du câble)",[3625,3987],{},[23,3989,3991],{"id":3990},"_7-trop-de-circuits-par-différentiel","7. Trop de circuits par différentiel",[16,3993,3994,3996],{},[55,3995,3635],{}," Art. 4.2.4.3b (max. 8 circuits terminaux par RCD 30 mA) ; Art. 5.3.5.2b (max. 8 prises par circuit terminal)",[367,3998,3640],{"id":3999},"description-6",[16,4001,4002,4003,4006],{},"Le RGIE limite le nombre de circuits par RCD 30 mA à ",[55,4004,4005],{},"maximum 8",". Dans les installations anciennes, tous les circuits sont souvent raccordés à un seul différentiel.",[367,4008,3647],{"id":4009},"pourquoi-cest-un-problème-6",[16,4011,4012],{},"Avec trop de circuits sur un même RCD, la probabilité de déclenchements intempestifs augmente (par addition des courants de fuite). De plus, en cas de défaut, toute l'habitation est privée de courant — pas seulement la zone concernée.",[367,4014,3658],{"id":4015},"comment-corriger-6",[444,4017,4018,4021,4024],{},[447,4019,4020],{},"Installer des RCD 30 mA supplémentaires",[447,4022,4023],{},"Répartir les circuits de manière logique (par ex. par étage ou fonction)",[447,4025,4026],{},"Maximum 8 circuits par RCD 30 mA",[367,4028,3673],{"id":4029},"coûts-typiques-6",[16,4031,4032],{},"100-200 € par RCD supplémentaire",[3625,4034],{},[23,4036,4038],{"id":4037},"_8-étiquetage-manquant-des-circuits","8. Étiquetage manquant des circuits",[16,4040,4041,4043],{},[55,4042,3635],{}," Art. 3.1.3.1 (identification des circuits)",[367,4045,3640],{"id":4046},"description-7",[16,4048,4049,4050,4053],{},"Tous les disjoncteurs et RCD dans le tableau de distribution doivent être ",[55,4051,4052],{},"clairement étiquetés",". L'étiquetage doit indiquer quelle pièce ou quel appareil est alimenté par le circuit concerné.",[367,4055,3647],{"id":4056},"pourquoi-cest-un-problème-7",[16,4058,4059],{},"Sans étiquetage, le bon circuit ne peut pas être rapidement coupé en cas d'urgence. Pour les travaux de maintenance également, une attribution claire est indispensable.",[367,4061,3658],{"id":4062},"comment-corriger-7",[444,4064,4065,4068,4071],{},[447,4066,4067],{},"Apposer des étiquettes lisibles sur tous les disjoncteurs",[447,4069,4070],{},"Dénomination par pièce et\u002Fou fonction (par ex. \"Cuisine prises\", \"Salle de bains éclairage\")",[447,4072,4073],{},"L'étiquetage doit correspondre au schéma unifilaire",[367,4075,3673],{"id":4076},"coûts-typiques-7",[16,4078,4079],{},"10-30 € (étiquettes et marqueur — réalisable soi-même)",[3625,4081],{},[23,4083,4085],{"id":4084},"_9-câbles-sans-protection","9. Câbles sans protection",[16,4087,4088,4090],{},[55,4089,3635],{}," Art. 5.2.2 (modes de pose) \u002F Art. 5.2.1.5 (résistance mécanique)",[367,4092,3640],{"id":4093},"description-8",[16,4095,4096],{},"Les câbles électriques doivent être posés dans des tubes de protection (gaines), des goulottes ou des saignées murales. Des câbles apparents sans protection mécanique — par exemple en saillie ou en vrac dans la cave — constituent une infraction.",[367,4098,3647],{"id":4099},"pourquoi-cest-un-problème-8",[16,4101,4102],{},"Les câbles non protégés peuvent être endommagés mécaniquement (clou, vis, rongeurs). Un isolant de câble endommagé peut provoquer des courts-circuits et des incendies.",[367,4104,3658],{"id":4105},"comment-corriger-8",[444,4107,4108,4111,4114],{},[447,4109,4110],{},"Placer les câbles apparents dans des goulottes (tubes de protection)",[447,4112,4113],{},"Pour le montage en saillie : utiliser des goulottes adaptées",[447,4115,4116],{},"Étanchéifier les traversées de murs avec des manchons coupe-feu",[367,4118,3673],{"id":4119},"coûts-typiques-8",[16,4121,4122],{},"100-400 € (selon la quantité de câbles et le mode de pose)",[3625,4124],{},[23,4126,4128],{"id":4127},"_10-parafoudre-spd-absent-pour-nouvelle-installation","10. Parafoudre (SPD) absent pour nouvelle installation",[16,4130,4131,4133],{},[55,4132,3635],{}," Art. 4.5.1",[367,4135,3640],{"id":4136},"description-9",[16,4138,4139],{},"L'Art. 4.5.1 prescrit de manière générale que les personnes et les biens doivent être protégés contre les effets nuisibles des surtensions — selon les règles de l'art. En pratique, un SPD (parafoudre) est exigé pour les nouvelles installations et les extensions substantielles. Pour les installations existantes, il est recommandé mais pas expressément imposé.",[367,4141,3647],{"id":4142},"pourquoi-cest-un-problème-9",[16,4144,4145],{},"Les surtensions dues à la foudre ou aux perturbations du réseau peuvent détruire l'électronique sensible. Un SPD dévie les surtensions en toute sécurité vers la terre et protège les appareils connectés.",[367,4147,3658],{"id":4148},"comment-corriger-9",[444,4150,4151,4154,4157],{},[447,4152,4153],{},"Installer un SPD Type 2 dans le tableau de distribution (après l'interrupteur principal, avant les RCD)",[447,4155,4156],{},"En cas d'installation paratonnerre : ajouter un SPD Type 1",[447,4158,4159],{},"Vérifier régulièrement l'indicateur d'état du SPD (vert = OK)",[367,4161,3673],{"id":4162},"coûts-typiques-9",[16,4164,4165],{},"80-200 € (matériel + installation)",[3625,4167],{},[23,4169,4171],{"id":4170},"conclusion-lauto-contrôle-comme-aide-à-la-planification","Conclusion : L'auto-contrôle comme aide à la planification",[16,4173,4174],{},"PlanElec signale certains problèmes de planification pris en charge, par exemple pour les différentiels, protections, sections de câble ou étiquettes. Un outil de planification ne peut pas détecter les défauts physiques. L'auto-contrôle n'est ni complet ni officiel ; l'état interne des règles date actuellement du 31.03.2025 et doit encore intégrer les modifications de 2026.",[3625,4176],{},[16,4178,4179],{},[55,4180,4181],{},"Articles connexes :",[444,4183,4184,4190,4196,4201],{},[447,4185,4186],{},[262,4187,4189],{"href":4188},"\u002Ffr\u002Fblog\u002Fcontrole-electrique-refuse","Contrôle électrique refusé — que faire ?",[447,4191,4192],{},[262,4193,4195],{"href":4194},"\u002Ffr\u002Fblog\u002Fdifferentiel-30ma","Différentiel 30 mA : quand est-il obligatoire ?",[447,4197,4198],{},[262,4199,4200],{"href":565},"Section de câble et disjoncteur : la bonne combinaison",[447,4202,4203],{},[262,4204,4206],{"href":4205},"\u002Ffr\u002Fblog\u002Fcables-salle-de-bains-zones-rgie","Câbles salle de bains et zones RGIE",[16,4208,4209,4212,4213],{},[55,4210,4211],{},"Structurez votre planification avec PlanElec et utilisez l'auto-contrôle pour préparer la vérification professionnelle et le contrôle officiel."," ",[262,4214,4216],{"href":483,"rel":4215},[266],"Commencer maintenant →",{"title":487,"searchDepth":488,"depth":488,"links":4218},[4219,4225,4231,4237,4243,4249,4255,4261,4267,4273,4279],{"id":3629,"depth":488,"text":3630,"children":4220},[4221,4222,4223,4224],{"id":3639,"depth":497,"text":3640},{"id":3646,"depth":497,"text":3647},{"id":3657,"depth":497,"text":3658},{"id":3672,"depth":497,"text":3673},{"id":3681,"depth":488,"text":3682,"children":4226},[4227,4228,4229,4230],{"id":3690,"depth":497,"text":3640},{"id":3702,"depth":497,"text":3647},{"id":3708,"depth":497,"text":3658},{"id":3725,"depth":497,"text":3673},{"id":3736,"depth":488,"text":3737,"children":4232},[4233,4234,4235,4236],{"id":3745,"depth":497,"text":3640},{"id":3751,"depth":497,"text":3647},{"id":3757,"depth":497,"text":3658},{"id":3774,"depth":497,"text":3673},{"id":3782,"depth":488,"text":3783,"children":4238},[4239,4240,4241,4242],{"id":3791,"depth":497,"text":3640},{"id":3801,"depth":497,"text":3647},{"id":3807,"depth":497,"text":3658},{"id":3821,"depth":497,"text":3673},{"id":3829,"depth":488,"text":3830,"children":4244},[4245,4246,4247,4248],{"id":3838,"depth":497,"text":3640},{"id":3844,"depth":497,"text":3647},{"id":3850,"depth":497,"text":3658},{"id":3867,"depth":497,"text":3673},{"id":3875,"depth":488,"text":3876,"children":4250},[4251,4252,4253,4254],{"id":3884,"depth":497,"text":3640},{"id":3890,"depth":497,"text":3647},{"id":3900,"depth":497,"text":3658},{"id":3982,"depth":497,"text":3673},{"id":3990,"depth":488,"text":3991,"children":4256},[4257,4258,4259,4260],{"id":3999,"depth":497,"text":3640},{"id":4009,"depth":497,"text":3647},{"id":4015,"depth":497,"text":3658},{"id":4029,"depth":497,"text":3673},{"id":4037,"depth":488,"text":4038,"children":4262},[4263,4264,4265,4266],{"id":4046,"depth":497,"text":3640},{"id":4056,"depth":497,"text":3647},{"id":4062,"depth":497,"text":3658},{"id":4076,"depth":497,"text":3673},{"id":4084,"depth":488,"text":4085,"children":4268},[4269,4270,4271,4272],{"id":4093,"depth":497,"text":3640},{"id":4099,"depth":497,"text":3647},{"id":4105,"depth":497,"text":3658},{"id":4119,"depth":497,"text":3673},{"id":4127,"depth":488,"text":4128,"children":4274},[4275,4276,4277,4278],{"id":4136,"depth":497,"text":3640},{"id":4142,"depth":497,"text":3647},{"id":4148,"depth":497,"text":3658},{"id":4162,"depth":497,"text":3673},{"id":4170,"depth":488,"text":4171},"2026-06-20","Quelles infractions RGIE sont les plus fréquemment constatées lors du contrôle électrique en Belgique ? Ce guide présente le top 10 avec les articles RGIE, les solutions et les coûts typiques.",{},"\u002Fblog\u002Ftop-10-arei-violations.fr",{"title":3614,"description":4281},"10-infractions-rgie-frequentes","blog\u002Ftop-10-arei-violations.fr",[921,4288,4289,4290,4291,4292,4293,4294],"infractions","controle-electrique","controle","differentiel","mise-a-la-terre","belgique","defauts","g8OipPDC_tfl3l_KWTjZpTxEgo36wbcviQ9EGjOyIio",{"id":4297,"title":4298,"articleId":4299,"body":4300,"category":906,"date":4821,"description":4822,"extension":507,"lastUpdated":2234,"locale":508,"meta":4823,"navigation":510,"path":4824,"publishDate":4821,"readTime":1235,"refreshInterval":913,"seo":4825,"slug":4826,"stem":4827,"tags":4828,"__hash__":4831},"blog\u002Fblog\u002Finspection-failed-what-now.fr.md","Contrôle électrique refusé — que faire ? Guide étape par étape après un contrôle négatif","inspection-failed-what-now",{"type":9,"value":4301,"toc":4801},[4302,4305,4311,4314,4318,4325,4329,4397,4404,4408,4412,4419,4423,4430,4434,4441,4445,4597,4601,4605,4608,4619,4623,4630,4634,4637,4657,4664,4678,4682,4689,4693,4704,4708,4715,4718,4732,4736,4742,4768,4771,4773,4777,4793],[12,4303,4298],{"id":4304},"contrôle-électrique-refusé-que-faire-guide-étape-par-étape-après-un-contrôle-négatif",[16,4306,4307,4310],{},[55,4308,4309],{},"Pas de panique."," Environ 40 % de tous les contrôles électriques en Belgique sont négatifs. Un contrôle négatif ne signifie pas que toute votre installation est dangereuse — il s'agit souvent de défauts formels ou de problèmes facilement corrigeables.",[16,4312,4313],{},"Dans ce guide, vous découvrirez ce qu'il faut faire après un contrôle négatif, quels sont les codes d'infraction et comment vous préparer au recontrôle.",[23,4315,4317],{"id":4316},"que-se-passe-t-il-après-un-contrôle-négatif","Que se passe-t-il après un contrôle négatif ?",[16,4319,4320,4321,4324],{},"Après le contrôle, vous recevez un ",[55,4322,4323],{},"rapport détaillé"," de l'organisme de contrôle (par ex. BTV, Vinçotte, AIB). Ce rapport liste toutes les infractions constatées, chacune avec un code :",[367,4326,4328],{"id":4327},"comprendre-les-codes-dinfraction","Comprendre les codes d'infraction",[28,4330,4331,4347],{},[31,4332,4333],{},[34,4334,4335,4338,4341,4344],{},[37,4336,4337],{},"Code",[37,4339,4340],{},"Gravité",[37,4342,4343],{},"Signification",[37,4345,4346],{},"Délai",[47,4348,4349,4365,4381],{},[34,4350,4351,4356,4359,4362],{},[52,4352,4353],{},[55,4354,4355],{},"C1",[52,4357,4358],{},"Léger",[52,4360,4361],{},"Défaut mineur, pas de danger immédiat",[52,4363,4364],{},"Corriger à la prochaine occasion",[34,4366,4367,4372,4375,4378],{},[52,4368,4369],{},[55,4370,4371],{},"C2",[52,4373,4374],{},"Moyen",[52,4376,4377],{},"Défaut à corriger à moyen terme",[52,4379,4380],{},"Doit être corrigé lors du recontrôle",[34,4382,4383,4388,4391,4394],{},[52,4384,4385],{},[55,4386,4387],{},"C3",[52,4389,4390],{},"Grave",[52,4392,4393],{},"Danger sérieux — action immédiate requise",[52,4395,4396],{},"Corriger immédiatement",[16,4398,4399,4400,4403],{},"En présence d'infractions C2 et C3, le contrôle est ",[55,4401,4402],{},"négatif"," et un recontrôle est nécessaire. Avec uniquement des infractions C1, le contrôle peut tout de même être positif.",[23,4405,4407],{"id":4406},"délais-selon-la-situation","Délais selon la situation",[367,4409,4411],{"id":4410},"lors-dune-vente-immobilière","Lors d'une vente immobilière",[16,4413,4414,4415,4418],{},"Si vous achetez un bien immobilier et que le contrôle électrique est négatif, vous disposez en tant qu'acheteur d'un ",[55,4416,4417],{},"délai de 18 mois"," à compter de la date d'achat pour corriger toutes les infractions et obtenir un recontrôle positif.",[367,4420,4422],{"id":4421},"pour-une-nouvelle-installation","Pour une nouvelle installation",[16,4424,4425,4426,4429],{},"Pour une nouvelle installation électrique (construction neuve, rénovation complète), l'installation doit être conforme ",[55,4427,4428],{},"AVANT la mise en service",". Le gestionnaire de réseau (Fluvius, ORES) n'active le courant que lorsqu'un certificat de contrôle positif est présenté.",[367,4431,4433],{"id":4432},"lors-du-contrôle-périodique","Lors du contrôle périodique",[16,4435,4436,4437,4440],{},"Le contrôle périodique (tous les 25 ans pour les habitations) donne, en cas de résultat négatif, un délai indiqué dans le rapport — typiquement ",[55,4438,4439],{},"1 an"," pour le recontrôle.",[23,4442,4444],{"id":4443},"les-10-causes-de-refus-les-plus-fréquentes","Les 10 causes de refus les plus fréquentes",[28,4446,4447,4463],{},[31,4448,4449],{},[34,4450,4451,4454,4457,4460],{},[37,4452,4453],{},"N°",[37,4455,4456],{},"Défaut",[37,4458,4459],{},"Article RGIE",[37,4461,4462],{},"Fréquence",[47,4464,4465,4479,4491,4505,4518,4531,4544,4557,4570,4584],{},[34,4466,4467,4470,4473,4476],{},[52,4468,4469],{},"1",[52,4471,4472],{},"Différentiel 30 mA absent ou inadéquat",[52,4474,4475],{},"Art. 4.2.4.3",[52,4477,4478],{},"Très fréquent",[34,4480,4481,4483,4486,4489],{},[52,4482,658],{},[52,4484,4485],{},"Plans électriques absents ou obsolètes (obligation de documentation : Art. 9.1.2 Nr. 1 schéma unifilaire, Art. 9.1.2 Nr. 2 plan de situation)",[52,4487,4488],{},"Art. 9.1.2 \u002F 3.1.2",[52,4490,4478],{},[34,4492,4493,4496,4499,4502],{},[52,4494,4495],{},"3",[52,4497,4498],{},"Mise à la terre défectueuse (résistance de terre trop élevée : Art. 4.2.4.3b fixe 30 Ω comme seuil réglementaire — en cas de dépassement, des dispositifs différentiels à haute sensibilité supplémentaires sont requis ; formule générale : R_A × I∆n ≤ 50 V)",[52,4500,4501],{},"Art. 4.2.4.3b",[52,4503,4504],{},"Fréquent",[34,4506,4507,4510,4513,4516],{},[52,4508,4509],{},"4",[52,4511,4512],{},"Étiquetage manquant des circuits",[52,4514,4515],{},"Art. 6.4.6",[52,4517,4504],{},[34,4519,4520,4523,4526,4529],{},[52,4521,4522],{},"5",[52,4524,4525],{},"Câbles sans tube de protection\u002Fgoulotte (les câbles XVB peuvent être posés en apparent sans tube de protection. Les conducteurs VOB individuels doivent toujours être posés dans des tubes de protection)",[52,4527,4528],{},"Art. 5.2.1.5",[52,4530,4504],{},[34,4532,4533,4536,4539,4542],{},[52,4534,4535],{},"6",[52,4537,4538],{},"Zones salle de bains non respectées",[52,4540,4541],{},"Art. 7.1",[52,4543,4374],{},[34,4545,4546,4549,4552,4555],{},[52,4547,4548],{},"7",[52,4550,4551],{},"Interrupteur principal absent (ou \u003C40A)",[52,4553,4554],{},"Art. 5.3.5.1b",[52,4556,4374],{},[34,4558,4559,4562,4565,4568],{},[52,4560,4561],{},"8",[52,4563,4564],{},"Disjoncteur surdimensionné pour la section de câble",[52,4566,4567],{},"Art. 4.4.3.2",[52,4569,4374],{},[34,4571,4572,4575,4578,4581],{},[52,4573,4574],{},"9",[52,4576,4577],{},"SPD absent pour nouvelle installation",[52,4579,4580],{},"Art. 4.5.1",[52,4582,4583],{},"Construction neuve",[34,4585,4586,4589,4592,4595],{},[52,4587,4588],{},"10",[52,4590,4591],{},"Détecteurs de fumée absents sur le plan de situation (les détecteurs de fumée ne sont pas une exigence RGIE à proprement parler, mais une prescription du droit de la construction\u002Fdu logement — régionale : Flandre, Wallonie, Bruxelles. L'absence peut être notée comme remarque dans le rapport de contrôle)",[52,4593,4594],{},"Régional",[52,4596,4504],{},[23,4598,4600],{"id":4599},"étape-par-étape-après-le-contrôle-négatif","Étape par étape : après le contrôle négatif",[367,4602,4604],{"id":4603},"étape-1-lire-attentivement-le-rapport","Étape 1 : Lire attentivement le rapport",[16,4606,4607],{},"Examinez chaque infraction individuellement. Notez :",[444,4609,4610,4613,4616],{},[447,4611,4612],{},"Quel code (C1\u002FC2\u002FC3) ?",[447,4614,4615],{},"Où se situe exactement le problème (pièce, circuit) ?",[447,4617,4618],{},"Que reproche-t-on exactement ?",[367,4620,4622],{"id":4621},"étape-2-établir-les-priorités","Étape 2 : Établir les priorités",[16,4624,4625,4626,4629],{},"Commencez par les ",[55,4627,4628],{},"infractions C3"," (graves) — elles représentent un danger immédiat. Ensuite les infractions C2. Les infractions C1 peuvent être résolues en parallèle ou ultérieurement.",[367,4631,4633],{"id":4632},"étape-3-professionnel-ou-soi-même","Étape 3 : Professionnel ou soi-même ?",[16,4635,4636],{},"Beaucoup de défauts peuvent être corrigés soi-même :",[444,4638,4639,4645,4651],{},[447,4640,4641,4644],{},[55,4642,4643],{},"Apposer l'étiquetage"," — étiqueter les disjoncteurs dans le tableau",[447,4646,4647,4650],{},[55,4648,4649],{},"Mettre à jour le plan de situation"," — créer avec PlanElec",[447,4652,4653,4656],{},[55,4654,4655],{},"Installer des détecteurs de fumée"," — simple montage au plafond",[16,4658,4659,4660,4663],{},"Pour d'autres défauts, un ",[55,4661,4662],{},"électricien"," est nécessaire :",[444,4665,4666,4669,4672,4675],{},[447,4667,4668],{},"Ajouter ou remplacer le différentiel",[447,4670,4671],{},"Améliorer la mise à la terre",[447,4673,4674],{},"Placer les câbles dans des tubes de protection",[447,4676,4677],{},"Installer l'interrupteur principal",[367,4679,4681],{"id":4680},"étape-4-mettre-à-jour-les-plans","Étape 4 : Mettre à jour les plans",[16,4683,4684,4685,4688],{},"L'un des défauts les plus fréquents est un schéma unifilaire et un plan de situation absents ou obsolètes. Ceux-ci doivent refléter ",[55,4686,4687],{},"l'état actuel"," de l'installation — pas l'état d'il y a 20 ans.",[367,4690,4692],{"id":4691},"étape-5-planifier-le-recontrôle","Étape 5 : Planifier le recontrôle",[16,4694,4695,4696,4699,4700,4703],{},"Il est recommandé de prendre rendez-vous auprès du ",[55,4697,4698],{},"même organisme de contrôle"," qui a effectué le contrôle initial — mais le propriétaire peut aussi choisir un autre organisme de contrôle accrédité. Lors du recontrôle, ",[55,4701,4702],{},"seuls les points contestés"," sont réexaminés — pas l'installation complète.",[23,4705,4707],{"id":4706},"coût-du-recontrôle","Coût du recontrôle",[16,4709,4710,4711,4714],{},"Le coût d'un recontrôle se situe typiquement entre ",[55,4712,4713],{},"80 € et 120 €",", selon l'organisme de contrôle et le nombre de points à vérifier. C'est généralement moins cher que le premier contrôle.",[16,4716,4717],{},"S'ajoutent les coûts de correction des défauts :",[444,4719,4720,4723,4726,4729],{},[447,4721,4722],{},"Ajouter un différentiel : 100-200 € (matériel + main-d'oeuvre)",[447,4724,4725],{},"Améliorer la mise à la terre : 200-500 €",[447,4727,4728],{},"Faire établir les plans : 150-400 € (ou gratuitement avec PlanElec)",[447,4730,4731],{},"Installer l'interrupteur principal : 80-150 €",[23,4733,4735],{"id":4734},"comment-planelec-vous-aide","Comment PlanElec vous aide",[16,4737,4738,4739,583],{},"PlanElec peut détecter bon nombre des causes de refus les plus fréquentes ",[55,4740,4741],{},"AVANT le contrôle",[444,4743,4744,4750,4756,4762],{},[447,4745,4746,4749],{},[55,4747,4748],{},"La validation"," vérifie automatiquement les différentiels manquants, la protection inadéquate et plus encore",[447,4751,4752,4755],{},[55,4753,4754],{},"Le schéma unifilaire"," est généré conformément au RGIE — l'une des causes de refus les plus courantes est éliminée",[447,4757,4758,4761],{},[55,4759,4760],{},"Le plan de situation"," avec les symboles RGIE corrects",[447,4763,4764,4767],{},[55,4765,4766],{},"L'étiquetage"," de tous les circuits est automatiquement documenté dans le schéma",[16,4769,4770],{},"Vous évitez ainsi les erreurs typiques avant la visite du contrôleur.",[3625,4772],{},[16,4774,4775],{},[55,4776,4181],{},[444,4778,4779,4785,4789],{},[447,4780,4781],{},[262,4782,4784],{"href":4783},"\u002Ffr\u002Fblog\u002F10-infractions-rgie-frequentes","Les 10 infractions RGIE les plus fréquentes",[447,4786,4787],{},[262,4788,4195],{"href":4194},[447,4790,4791],{},[262,4792,4200],{"href":565},[16,4794,4795,4212,4798],{},[55,4796,4797],{},"Préparez vos plans électriques avec PlanElec et utilisez l'auto-contrôle comme aide avant la vérification professionnelle et le contrôle officiel.",[262,4799,4216],{"href":483,"rel":4800},[266],{"title":487,"searchDepth":488,"depth":488,"links":4802},[4803,4806,4811,4812,4819,4820],{"id":4316,"depth":488,"text":4317,"children":4804},[4805],{"id":4327,"depth":497,"text":4328},{"id":4406,"depth":488,"text":4407,"children":4807},[4808,4809,4810],{"id":4410,"depth":497,"text":4411},{"id":4421,"depth":497,"text":4422},{"id":4432,"depth":497,"text":4433},{"id":4443,"depth":488,"text":4444},{"id":4599,"depth":488,"text":4600,"children":4813},[4814,4815,4816,4817,4818],{"id":4603,"depth":497,"text":4604},{"id":4621,"depth":497,"text":4622},{"id":4632,"depth":497,"text":4633},{"id":4680,"depth":497,"text":4681},{"id":4691,"depth":497,"text":4692},{"id":4706,"depth":488,"text":4707},{"id":4734,"depth":488,"text":4735},"2026-06-16","Votre contrôle électrique est négatif ? Pas de panique — environ 40 % des contrôles échouent. Découvrez ce que signifient les codes d'infraction, comment corriger les problèmes et combien coûte le recontrôle.",{},"\u002Fblog\u002Finspection-failed-what-now.fr",{"title":4298,"description":4822},"controle-electrique-refuse","blog\u002Finspection-failed-what-now.fr",[4290,4289,4829,4288,4830,921,4293],"refuse","recontrole","xwVFvDJ8UR_D1jeKKT5jPFfc7sUFhy6dKTkXHL-LbsM",{"id":4833,"title":4834,"articleId":4835,"body":4836,"category":2574,"date":5084,"description":5085,"extension":507,"lastUpdated":2234,"locale":508,"meta":5086,"navigation":510,"path":5087,"publishDate":5084,"readTime":2579,"refreshInterval":913,"seo":5088,"slug":5089,"stem":5090,"tags":5091,"__hash__":5096},"blog\u002Fblog\u002Fsmart-home-domotica-arei.fr.md","Smart Home et RGIE : Que faut-il savoir sur la domotique ?","smart-home-domotica-arei",{"type":9,"value":4837,"toc":5076},[4838,4841,4847,4851,4857,4860,4874,4878,4885,4892,4896,4991,4995,5002,5005,5009,5016,5033,5037,5044,5046,5050,5068],[12,4839,4834],{"id":4840},"smart-home-et-rgie-que-faut-il-savoir-sur-la-domotique",[16,4842,4843,4846],{},[55,4844,4845],{},"Le RGIE ne réglemente pas directement les appareils Smart Home"," — mais l'installation électrique sous-jacente doit dans tous les cas être conforme au RGIE. Qu'il s'agisse d'interrupteurs WiFi, de prises intelligentes ou de modules DIN-rail : tant que l'installation de base respecte les prescriptions, les solutions Smart Home ne posent aucun problème.",[23,4848,4850],{"id":4849},"quest-ce-qui-est-autorisé","Qu'est-ce qui est autorisé ?",[16,4852,4853,4854,567],{},"Les appareils Smart Home comme les interrupteurs WiFi (Shelly, Sonoff), les prises intelligentes (TP-Link, Hue Smart Plug) ou les ampoules connectées (Philips Hue, IKEA TRADFRI) peuvent être utilisés sans problème — ",[55,4855,4856],{},"tant que l'installation électrique sous-jacente est conforme au RGIE",[16,4858,4859],{},"Cela signifie :",[444,4861,4862,4865,4868,4871],{},[447,4863,4864],{},"Le câblage doit être correctement dimensionné",[447,4866,4867],{},"Les disjoncteurs et différentiels doivent être présents et correctement assignés",[447,4869,4870],{},"L'installation doit être mise à la terre",[447,4872,4873],{},"Les modules Smart Home dans l'installation fixe doivent porter le marquage CE et être homologués pour l'installation fixe",[23,4875,4877],{"id":4876},"modules-smart-din-rail-dans-le-tableau-de-distribution","Modules Smart DIN-rail dans le tableau de distribution",[16,4879,4880,4881,4884],{},"Une catégorie particulière concerne les ",[55,4882,4883],{},"modules Smart DIN-rail"," comme Shelly Pro, Shelly Pro 3EM ou les modules DIN Sonoff. Ceux-ci sont installés directement dans le tableau de distribution sur le rail DIN.",[16,4886,4887,4888,4891],{},"Important : comme ils font partie de l'installation fixe dans le tableau, ",[55,4889,4890],{},"les modules DIN-rail apparaissent dans le schéma unifilaire"," (qui, selon la Section 3.1.2.2.a, doit notamment représenter les dispositifs de protection, les interrupteurs et les appareils fixes ; l'obligation de conserver le schéma au sein du dossier de l'installation découle de l'Art. 9.1.2). Ils doivent y être correctement représentés, tout comme les autres composants du tableau.",[23,4893,4895],{"id":4894},"aperçu-types-smart-home-et-rgie","Aperçu : Types Smart Home et RGIE",[28,4897,4898,4913],{},[31,4899,4900],{},[34,4901,4902,4905,4907,4910],{},[37,4903,4904],{},"Type Smart Home",[37,4906,2822],{},[37,4908,4909],{},"RGIE pertinent ?",[37,4911,4912],{},"Dans le schéma unifilaire ?",[47,4914,4915,4929,4941,4953,4966,4979],{},[34,4916,4917,4920,4923,4926],{},[52,4918,4919],{},"Interrupteur WiFi (Shelly 1, Sonoff)",[52,4921,4922],{},"Derrière interrupteur existant",[52,4924,4925],{},"Non, si installation de base conforme",[52,4927,4928],{},"Non, si aucune modification du câblage. Oui, si le câblage fixe est modifié (par ex. neutre tiré vers l'interrupteur)",[34,4930,4931,4934,4937,4939],{},[52,4932,4933],{},"Prise intelligente (plug-in)",[52,4935,4936],{},"Dans prise existante",[52,4938,2911],{},[52,4940,2911],{},[34,4942,4943,4946,4949,4951],{},[52,4944,4945],{},"Ampoule connectée (Hue, TRADFRI)",[52,4947,4948],{},"Dans douille existante",[52,4950,2911],{},[52,4952,2911],{},[34,4954,4955,4958,4961,4964],{},[52,4956,4957],{},"Module DIN-rail (Shelly Pro)",[52,4959,4960],{},"Tableau de distribution",[52,4962,4963],{},"Oui — installation fixe",[52,4965,150],{},[34,4967,4968,4971,4974,4977],{},[52,4969,4970],{},"Thermostat intelligent (Nest, tado)",[52,4972,4973],{},"Montage mural",[52,4975,4976],{},"Non, si correctement câblé",[52,4978,2911],{},[34,4980,4981,4984,4987,4989],{},[52,4982,4983],{},"Serrure connectée",[52,4985,4986],{},"Cadre de porte",[52,4988,2911],{},[52,4990,2911],{},[23,4992,4994],{"id":4993},"linterrupteur-physique-reste-obligatoire","L'interrupteur physique reste obligatoire",[16,4996,4997,4998,5001],{},"Une erreur fréquente : ",[55,4999,5000],{},"les appareils Smart Home ne remplacent PAS les interrupteurs physiques prescrits",". L'installation doit pouvoir à tout moment être commandée et coupée en toute sécurité — et les interrupteurs et dispositifs de commande eux-mêmes doivent être conformes à la norme et, lorsqu'ils assurent une fonction de sectionnement, couper simultanément tous les conducteurs actifs (Art. 5.3.5.4). Un module Shelly derrière l'interrupteur est autorisé — supprimer l'interrupteur et commander uniquement via l'application ne l'est pas.",[16,5003,5004],{},"Cela s'applique aussi aux prises : une prise intelligente ne remplace pas la prise fixe installée derrière elle.",[23,5006,5008],{"id":5007},"lors-du-contrôle-électrique","Lors du contrôle électrique",[16,5010,5011,5012,5015],{},"Lors du contrôle électrique, l'organisme de contrôle vérifie l'",[55,5013,5014],{},"installation électrique",", pas la logique Smart Home. Cela signifie :",[444,5017,5018,5021,5024,5030],{},[447,5019,5020],{},"Le câblage, les disjoncteurs et la mise à la terre sont vérifiés",[447,5022,5023],{},"Les modules DIN-rail doivent figurer dans le schéma",[447,5025,5026,5027],{},"L'application Smart Home ou les règles d'automatisation ne sont ",[55,5028,5029],{},"pas contrôlées",[447,5031,5032],{},"Les interrupteurs WiFi derrière le mur ne sont généralement pas contestés si l'installation de base est conforme",[23,5034,5036],{"id":5035},"modules-shelly-dans-le-cabinet-editor-avec-planelec","Modules Shelly dans le Cabinet Editor avec PlanElec",[16,5038,5039,5040,5043],{},"Avec PlanElec, vous pouvez placer des modules Shelly DIN-rail et d'autres composants Smart Home dans le ",[55,5041,5042],{},"Cabinet Editor"," sur le rail DIN et les documenter correctement dans le schéma unifilaire.",[3625,5045],{},[16,5047,5048],{},[55,5049,4181],{},[444,5051,5052,5058,5062],{},[447,5053,5054],{},[262,5055,5057],{"href":5056},"\u002Ffr\u002Fblog\u002Fcircuits-dedies","Circuits dédiés : quels appareils nécessitent leur propre circuit ?",[447,5059,5060],{},[262,5061,4784],{"href":4783},[447,5063,5064],{},[262,5065,5067],{"href":5066},"\u002Ffr\u002Fblog\u002Freglementation-rgie-2026","Réglementation RGIE 2026 : qu'est-ce qui a changé ?",[16,5069,5070,4212,5073],{},[55,5071,5072],{},"Documentez votre installation Smart Home conformément au RGIE avec PlanElec — y compris les modules DIN-rail dans le schéma unifilaire.",[262,5074,4216],{"href":483,"rel":5075},[266],{"title":487,"searchDepth":488,"depth":488,"links":5077},[5078,5079,5080,5081,5082,5083],{"id":4849,"depth":488,"text":4850},{"id":4876,"depth":488,"text":4877},{"id":4894,"depth":488,"text":4895},{"id":4993,"depth":488,"text":4994},{"id":5007,"depth":488,"text":5008},{"id":5035,"depth":488,"text":5036},"2026-06-09","Une installation Smart Home doit-elle être conforme au RGIE ? Oui — l'installation électrique sous-jacente doit respecter les prescriptions. Découvrez ce qui est autorisé et les points d'attention.",{},"\u002Fblog\u002Fsmart-home-domotica-arei.fr",{"title":4834,"description":5085},"domotique-rgie","blog\u002Fsmart-home-domotica-arei.fr",[5092,5093,921,5094,5095,1574,4290],"smart-home","domotique","shelly","din-rail","rIeqODZGRFmPi_cE4HqPftM31UlH0qZrj990H2TDU8o",{"id":5098,"title":5099,"articleId":5100,"body":5101,"category":906,"date":5518,"description":5519,"extension":507,"lastUpdated":2234,"locale":508,"meta":5520,"navigation":510,"path":5521,"publishDate":5518,"readTime":1235,"refreshInterval":913,"seo":5522,"slug":5523,"stem":5524,"tags":5525,"__hash__":5532},"blog\u002Fblog\u002Fhome-battery-arei.fr.md","Batterie domestique et RGIE : Intégrer correctement un stockage batterie dans l'installation électrique","home-battery-arei",{"type":9,"value":5102,"toc":5497},[5103,5106,5109,5113,5116,5119,5123,5127,5134,5148,5152,5159,5163,5170,5174,5181,5185,5188,5191,5194,5214,5217,5220,5237,5241,5244,5258,5262,5269,5273,5280,5294,5301,5305,5308,5334,5338,5412,5416,5442,5445,5449,5455,5469,5471,5475,5489],[12,5104,5099],{"id":5105},"batterie-domestique-et-rgie-intégrer-correctement-un-stockage-batterie-dans-linstallation-électrique",[16,5107,5108],{},"Les batteries domestiques sont de plus en plus populaires en Belgique. Avec une installation PV, un stockage batterie permet de maximiser l'autoconsommation et de réduire la consommation depuis le réseau. Mais comment réaliser une installation conforme au RGIE ? Ce guide vous accompagne à travers toutes les exigences.",[23,5110,5112],{"id":5111},"pourquoi-une-batterie-domestique","Pourquoi une batterie domestique ?",[16,5114,5115],{},"Avec le compteur numérique en Belgique, l'autoconsommation est plus rentable que jamais. Une batterie domestique stocke l'excédent de production solaire pendant la journée et le restitue le soir. L'économie typique se situe entre 30 et 60 % de la consommation réseau, selon la capacité de la batterie et le profil de consommation.",[16,5117,5118],{},"Le RGIE ne comporte pas de chapitre propre pour le stockage par batterie domestique — ce sont les règles générales qui s'appliquent (protection contre les chocs électriques, protection contre les surintensités, séparation\u002Fcoupure de sécurité). Le chapitre dédié aux batteries 7.103 (batteries d'accumulateurs industrielles) exclut explicitement les installations domestiques. Lorsque la batterie est couplée à une installation PV, l'Art. 7.112 (installations photovoltaïques domestiques à basse tension ≤ 10 kVA) s'applique à la partie PV ; la batterie elle-même n'en relève pas.",[23,5120,5122],{"id":5121},"exigences-rgie-pour-les-batteries-domestiques","Exigences RGIE pour les batteries domestiques",[367,5124,5126],{"id":5125},"circuit-dédié","Circuit dédié",[16,5128,5129,5130,5133],{},"La batterie domestique (plus précisément l'onduleur\u002Fonduleur hybride) nécessite un ",[55,5131,5132],{},"circuit propre et dédié"," dans le tableau de distribution. Ce circuit ne peut pas être partagé avec d'autres consommateurs.",[444,5135,5136,5142],{},[447,5137,5138,5141],{},[55,5139,5140],{},"Protection :"," MCB propre (disjoncteur), typiquement 20A ou 32A selon la puissance de l'onduleur. Sections de câble : protection 20 A → min. 2,5 mm², protection 32 A → min. 6 mm²",[447,5143,5144,5147],{},[55,5145,5146],{},"Différentiel :"," RCD 30 mA en amont. Pour un onduleur monophasé, le Type A suffit. Pour un onduleur triphasé sans surveillance intégrée des courants de défaut DC (RCMU), le Type B est requis. De nombreux onduleurs modernes (Huawei, Fronius) disposent d'un RCMU intégré qui permet l'utilisation du Type A",[367,5149,5151],{"id":5150},"interrupteur-de-séparation-point-de-coupure","Interrupteur de séparation (point de coupure)",[16,5153,5154,5155,5158],{},"Entre la batterie\u002Fl'onduleur et le réseau, un ",[55,5156,5157],{},"interrupteur de séparation omnipolaire"," doit être installé. Il permet de séparer complètement l'installation batterie du réseau — important pour les travaux de maintenance et la sécurité des techniciens réseau.",[367,5160,5162],{"id":5161},"protection-contre-les-surtensions-spd","Protection contre les surtensions (SPD)",[16,5164,5165,5166,5169],{},"Un ",[55,5167,5168],{},"parafoudre (SPD)"," est recommandé côté AC. L'Art. 4.5.1 formule le principe général que les personnes et les biens doivent être protégés contre les surtensions, mais ne prescrit pas de type SPD spécifique. Côté DC, un SPD est également conseillé, surtout en cas de câblage extérieur.",[367,5171,5173],{"id":5172},"ventilation-pour-batteries-lithium","Ventilation pour batteries lithium",[16,5175,5176,5177,5180],{},"Les batteries lithium-ion (utilisées dans toutes les batteries domestiques courantes) exigent une ",[55,5178,5179],{},"ventilation suffisante"," de la pièce d'installation. La pièce ne doit pas développer de chaleur excessive (recommandé : max. 35°C). Pour les systèmes plus grands, une ventilation active peut être nécessaire.",[23,5182,5184],{"id":5183},"intégration-dans-le-schéma-unifilaire","Intégration dans le schéma unifilaire",[16,5186,5187],{},"Le schéma unifilaire doit représenter correctement la batterie domestique. L'intégration comprend deux côtés :",[367,5189,2953],{"id":5190},"côté-dc",[16,5192,5193],{},"Le côté courant continu montre le trajet du pack batterie via le système de gestion de batterie (BMS) jusqu'à l'onduleur :",[444,5195,5196,5211],{},[447,5197,5198,5201,5202,5201,5205,5201,5208],{},[55,5199,5200],{},"Batterie"," → ",[55,5203,5204],{},"BMS",[55,5206,5207],{},"Interrupteur-sectionneur DC",[55,5209,5210],{},"Onduleur hybride",[447,5212,5213],{},"Pour les systèmes couplés AC : Batterie → onduleur batterie dédié → raccordement AC",[367,5215,2947],{"id":5216},"côté-ac",[16,5218,5219],{},"Le côté courant alternatif montre l'intégration dans le réseau domestique :",[444,5221,5222,5234],{},[447,5223,5224,5201,5226,5201,5229,5201,5232],{},[55,5225,5210],{},[55,5227,5228],{},"Interrupteur de séparation AC",[55,5230,5231],{},"MCB",[55,5233,4960],{},[447,5235,5236],{},"Le raccordement se fait typiquement après l'interrupteur principal, mais avant les RCD individuels des circuits",[367,5238,5240],{"id":5239},"représentation-dans-le-schéma","Représentation dans le schéma",[16,5242,5243],{},"Dans le schéma unifilaire, la batterie domestique apparaît comme un départ propre, similaire à l'installation PV. Les symboles comprennent :",[444,5245,5246,5249,5252,5255],{},[447,5247,5248],{},"Symbole de batterie (selon IEC 60617)",[447,5250,5251],{},"Symbole d'onduleur",[447,5253,5254],{},"Interrupteur de séparation",[447,5256,5257],{},"MCB et RCD associés",[23,5259,5261],{"id":5260},"fonction-de-secours-backup","Fonction de secours \u002F Backup",[16,5263,5264,5265,5268],{},"De nombreuses batteries domestiques modernes offrent une ",[55,5266,5267],{},"fonction de secours"," (backup). En cas de coupure du réseau, la batterie continue d'alimenter des circuits sélectionnés.",[367,5270,5272],{"id":5271},"dispositif-de-commutation","Dispositif de commutation",[16,5274,5275,5276,5279],{},"Si une fonction backup est souhaitée, un ",[55,5277,5278],{},"dispositif de commutation"," doit être installé :",[444,5281,5282,5288],{},[447,5283,5284,5287],{},[55,5285,5286],{},"Commutation automatique (ATS) :"," L'onduleur bascule automatiquement en mode îlot. La plupart des onduleurs hybrides ont cette fonction intégrée.",[447,5289,5290,5293],{},[55,5291,5292],{},"Commutation manuelle :"," Un commutateur permet la séparation manuelle du réseau et le fonctionnement en mode îlot.",[16,5295,5296,5297,5300],{},"Le dispositif de commutation doit être représenté dans le schéma unifilaire et être ",[55,5298,5299],{},"omnipolaire",", afin qu'aucun courant ne soit réinjecté dans le réseau en panne (danger pour les techniciens réseau).",[23,5302,5304],{"id":5303},"déclaration-au-gestionnaire-de-réseau","Déclaration au gestionnaire de réseau",[16,5306,5307],{},"L'installation d'une batterie domestique doit être déclarée au gestionnaire de réseau (Fluvius en Flandre, ORES\u002FRESA en Wallonie, Sibelga à Bruxelles) :",[444,5309,5310,5316,5322,5328],{},[447,5311,5312,5315],{},[55,5313,5314],{},"Avec installation PV existante :"," Déclaration de modification — l'installation est enregistrée comme PV + batterie",[447,5317,5318,5321],{},[55,5319,5320],{},"Données techniques :"," Capacité (kWh), puissance onduleur (kW), couplage AC ou DC",[447,5323,5324,5327],{},[55,5325,5326],{},"Nouveau schéma unifilaire :"," Un schéma mis à jour doit être soumis",[447,5329,5330,5333],{},[55,5331,5332],{},"Adaptation du contrôle électrique :"," En cas de modifications substantielles, un nouveau contrôle peut être nécessaire",[23,5335,5337],{"id":5336},"systèmes-populaires-en-belgique","Systèmes populaires en Belgique",[28,5339,5340,5359],{},[31,5341,5342],{},[34,5343,5344,5347,5350,5353,5356],{},[37,5345,5346],{},"Système",[37,5348,5349],{},"Capacité",[37,5351,5352],{},"Puissance",[37,5354,5355],{},"Couplage",[37,5357,5358],{},"Particularité",[47,5360,5361,5378,5395],{},[34,5362,5363,5366,5369,5372,5375],{},[52,5364,5365],{},"Huawei LUNA 2000",[52,5367,5368],{},"5-30 kWh",[52,5370,5371],{},"2.5-5 kW",[52,5373,5374],{},"DC (avec Huawei SUN2000)",[52,5376,5377],{},"Extensible par modules",[34,5379,5380,5383,5386,5389,5392],{},[52,5381,5382],{},"Tesla Powerwall 3",[52,5384,5385],{},"13.5 kWh",[52,5387,5388],{},"11.5 kW",[52,5390,5391],{},"AC ou DC",[52,5393,5394],{},"Onduleur intégré",[34,5396,5397,5400,5403,5406,5409],{},[52,5398,5399],{},"BYD HVS\u002FHVM",[52,5401,5402],{},"5.1-22.1 kWh",[52,5404,5405],{},"selon onduleur",[52,5407,5408],{},"DC (avec SMA\u002FFronius)",[52,5410,5411],{},"Flexible, éprouvé",[23,5413,5415],{"id":5414},"coûts-et-rentabilité","Coûts et rentabilité",[444,5417,5418,5424,5430,5436],{},[447,5419,5420,5423],{},[55,5421,5422],{},"Investissement :"," 4 000-8 000 € pour un système de 5-10 kWh de capacité (installation comprise)",[447,5425,5426,5429],{},[55,5427,5428],{},"Économie :"," 300-600 € par an, selon la part d'autoconsommation",[447,5431,5432,5435],{},[55,5433,5434],{},"ROI :"," 8-15 ans — rentable surtout avec une consommation diurne élevée et une grande installation PV",[447,5437,5438,5441],{},[55,5439,5440],{},"Primes :"," Vérifiez les primes régionales (varient selon la région et l'année)",[16,5443,5444],{},"Le ROI s'améliore avec la hausse des prix de l'électricité et la baisse des coûts des batteries. Un dimensionnement réaliste est essentiel : une batterie trop grande allonge le temps de retour sur investissement.",[23,5446,5448],{"id":5447},"batterie-domestique-dans-le-schéma-unifilaire-avec-planelec","Batterie domestique dans le schéma unifilaire avec PlanElec",[16,5450,5451,5452,5454],{},"Avec PlanElec, vous pouvez documenter correctement la batterie domestique dans le ",[55,5453,518],{},". Le logiciel prend en compte :",[444,5456,5457,5460,5463,5466],{},[447,5458,5459],{},"Circuit dédié avec MCB et RCD",[447,5461,5462],{},"Interrupteur de séparation et SPD",[447,5464,5465],{},"Symboles corrects selon IEC 60617",[447,5467,5468],{},"Validation de la conformité RGIE",[3625,5470],{},[16,5472,5473],{},[55,5474,4181],{},[444,5476,5477,5481,5485],{},[447,5478,5479],{},[262,5480,5067],{"href":5066},[447,5482,5483],{},[262,5484,5057],{"href":5056},[447,5486,5487],{},[262,5488,4200],{"href":565},[16,5490,5491,4212,5494],{},[55,5492,5493],{},"Documentez votre batterie domestique conformément au RGIE avec PlanElec — intégralement dans le schéma unifilaire.",[262,5495,4216],{"href":483,"rel":5496},[266],{"title":487,"searchDepth":488,"depth":488,"links":5498},[5499,5500,5506,5511,5514,5515,5516,5517],{"id":5111,"depth":488,"text":5112},{"id":5121,"depth":488,"text":5122,"children":5501},[5502,5503,5504,5505],{"id":5125,"depth":497,"text":5126},{"id":5150,"depth":497,"text":5151},{"id":5161,"depth":497,"text":5162},{"id":5172,"depth":497,"text":5173},{"id":5183,"depth":488,"text":5184,"children":5507},[5508,5509,5510],{"id":5190,"depth":497,"text":2953},{"id":5216,"depth":497,"text":2947},{"id":5239,"depth":497,"text":5240},{"id":5260,"depth":488,"text":5261,"children":5512},[5513],{"id":5271,"depth":497,"text":5272},{"id":5303,"depth":488,"text":5304},{"id":5336,"depth":488,"text":5337},{"id":5414,"depth":488,"text":5415},{"id":5447,"depth":488,"text":5448},"2026-06-02","Comment installer une batterie domestique selon le RGIE ? Ce guide explique les exigences en matière de circuit dédié, interrupteur de séparation, schéma unifilaire et déclaration au gestionnaire de réseau.",{},"\u002Fblog\u002Fhome-battery-arei.fr",{"title":5099,"description":5519},"batterie-domestique-rgie","blog\u002Fhome-battery-arei.fr",[5526,5527,921,5528,5529,5530,5531],"batterie-domestique","stockage-energie","photovoltaique","pv","schema-unifilaire","secours","-bsm5CKFhLtjP_5OdUvcQ2kEsY0z7BBA7p1qFywF8pw",{"id":5534,"title":5535,"articleId":5536,"body":5537,"category":2574,"date":5794,"description":5795,"extension":507,"lastUpdated":2234,"locale":508,"meta":5796,"navigation":510,"path":5797,"publishDate":5794,"readTime":2579,"refreshInterval":913,"seo":5798,"slug":5799,"stem":5800,"tags":5801,"__hash__":5805},"blog\u002Fblog\u002Fsmoke-detector-mandatory.fr.md","Détecteur de fumée obligatoire en Belgique : que prévoit la loi en Flandre, Wallonie et Bruxelles ?","smoke-detector-mandatory",{"type":9,"value":5538,"toc":5783},[5539,5542,5548,5552,5556,5559,5582,5586,5592,5607,5611,5618,5635,5639,5706,5710,5717,5720,5724,5753,5757,5763,5765,5769,5775],[12,5540,5535],{"id":5541},"détecteur-de-fumée-obligatoire-en-belgique-que-prévoit-la-loi-en-flandre-wallonie-et-bruxelles",[16,5543,5544,5547],{},[55,5545,5546],{},"Oui, les détecteurs de fumée sont obligatoires en Belgique"," — mais la législation est régionale. Selon que vous habitez en Flandre, en Wallonie ou à Bruxelles, les exigences en termes de nombre et d'emplacement diffèrent.",[23,5549,5551],{"id":5550},"réglementation-régionale-en-un-coup-doeil","Réglementation régionale en un coup d'oeil",[367,5553,5555],{"id":5554},"flandre","Flandre",[16,5557,5558],{},"Depuis le 1er janvier 2020, tous les logements en Flandre doivent être équipés de détecteurs de fumée. Les règles :",[444,5560,5561,5566,5572,5579],{},[447,5562,5563],{},[55,5564,5565],{},"Au minimum un détecteur de fumée par étage",[447,5567,5568,5571],{},[55,5569,5570],{},"Dans chaque voie d'évacuation"," (couloir, cage d'escalier) un détecteur doit être installé",[447,5573,5574,5575,5578],{},"Dans les chambres à coucher, l'installation est ",[55,5576,5577],{},"recommandée"," mais pas obligatoire",[447,5580,5581],{},"S'applique à tous les logements locatifs et propriétés",[367,5583,5585],{"id":5584},"wallonie","Wallonie",[16,5587,5588,5589,583],{},"La Wallonie a été pionnière avec l'obligation ",[55,5590,5591],{},"depuis 2010",[444,5593,5594,5598,5604],{},[447,5595,5596],{},[55,5597,5565],{},[447,5599,5600,5601],{},"Emplacements obligatoires : ",[55,5602,5603],{},"couloirs et cages d'escalier",[447,5605,5606],{},"En cas de location, le propriétaire doit assurer l'installation",[367,5608,5610],{"id":5609},"bruxelles","Bruxelles",[16,5612,5613,5614,5617],{},"La Région de Bruxelles-Capitale impose l'obligation ",[55,5615,5616],{},"depuis 2005"," — la plus ancienne réglementation en Belgique :",[444,5619,5620,5625,5632],{},[447,5621,5622],{},[55,5623,5624],{},"Un détecteur de fumée par étage",[447,5626,5627,5628,5631],{},"Obligatoire dans les ",[55,5629,5630],{},"voies d'évacuation"," (couloirs, escaliers)",[447,5633,5634],{},"S'applique à tous les bâtiments résidentiels",[23,5636,5638],{"id":5637},"tableau-récapitulatif","Tableau récapitulatif",[28,5640,5641,5660],{},[31,5642,5643],{},[34,5644,5645,5648,5651,5654,5657],{},[37,5646,5647],{},"Région",[37,5649,5650],{},"Obligatoire depuis",[37,5652,5653],{},"Nombre minimum",[37,5655,5656],{},"Emplacements obligatoires",[37,5658,5659],{},"Norme",[47,5661,5662,5678,5692],{},[34,5663,5664,5666,5669,5672,5675],{},[52,5665,5555],{},[52,5667,5668],{},"2020",[52,5670,5671],{},"1 par étage",[52,5673,5674],{},"Voies d'évacuation (couloirs, escaliers)",[52,5676,5677],{},"NBN EN 14604",[34,5679,5680,5682,5685,5687,5690],{},[52,5681,5585],{},[52,5683,5684],{},"2010",[52,5686,5671],{},[52,5688,5689],{},"Couloirs, cages d'escalier",[52,5691,5677],{},[34,5693,5694,5696,5699,5701,5704],{},[52,5695,5610],{},[52,5697,5698],{},"2005",[52,5700,5671],{},[52,5702,5703],{},"Voies d'évacuation",[52,5705,5677],{},[23,5707,5709],{"id":5708},"lien-avec-le-rgie-détecteurs-de-fumée-et-le-contrôle-électrique","Lien avec le RGIE : Détecteurs de fumée et le contrôle électrique",[16,5711,5712,5713,5716],{},"Point important : ",[55,5714,5715],{},"les détecteurs de fumée ne sont pas directement réglementés par le RGIE."," Le RGIE régit principalement l'installation électrique — câbles, fusibles, mise à la terre, etc. L'Art. 9.1.2 Nr. 2 exige que le dossier de l'installation électrique comprenne un plan de situation ; son contenu prescrit est défini de manière limitative (prises de courant, interrupteurs, points lumineux ainsi qu'appareils ou machines fixes) et ne comprend pas les détecteurs de fumée.",[16,5718,5719],{},"Comme les détecteurs de fumée ne font pas partie de l'installation électrique réglementée par le RGIE, ils ne font pas l'objet du contrôle électrique ; l'absence d'un détecteur de fumée ne constitue pas un défaut RGIE. Certains installateurs ou organismes de contrôle représentent néanmoins les détecteurs de fumée sur le plan de situation à titre informatif, afin de documenter la position de tous les appareils pertinents dans le logement.",[23,5721,5723],{"id":5722},"entretien-et-remplacement","Entretien et remplacement",[444,5725,5726,5732,5738,5744],{},[447,5727,5728,5731],{},[55,5729,5730],{},"Mensuellement :"," Appuyer sur le bouton de test pour vérifier le fonctionnement",[447,5733,5734,5737],{},[55,5735,5736],{},"Annuellement :"," Test approfondi et dépoussiérage",[447,5739,5740,5743],{},[55,5741,5742],{},"Tous les 10 ans :"," Remplacer complètement le détecteur (les capteurs perdent en sensibilité)",[447,5745,5746,5747,5750,5751],{},"Utilisez uniquement des détecteurs avec le ",[55,5748,5749],{},"marquage CE"," et conformes à la norme ",[55,5752,5677],{},[23,5754,5756],{"id":5755},"détecteurs-de-fumée-dans-le-plan-de-situation-avec-planelec","Détecteurs de fumée dans le plan de situation avec PlanElec",[16,5758,5759,5760,5762],{},"Avec PlanElec, vous pouvez dessiner les détecteurs de fumée directement dans le ",[55,5761,519],{}," de votre logement. Le symbole du détecteur de fumée est affiché correctement selon la norme RGIE, assurant que votre plan est complet lors du contrôle électrique.",[3625,5764],{},[16,5766,5767],{},[55,5768,4181],{},[444,5770,5771],{},[447,5772,5773],{},[262,5774,5067],{"href":5066},[16,5776,5777,4212,5780],{},[55,5778,5779],{},"Créez votre plan électrique conforme au RGIE avec PlanElec — y compris les symboles de détecteur de fumée dans le plan de situation.",[262,5781,4216],{"href":483,"rel":5782},[266],{"title":487,"searchDepth":488,"depth":488,"links":5784},[5785,5790,5791,5792,5793],{"id":5550,"depth":488,"text":5551,"children":5786},[5787,5788,5789],{"id":5554,"depth":497,"text":5555},{"id":5584,"depth":497,"text":5585},{"id":5609,"depth":497,"text":5610},{"id":5637,"depth":488,"text":5638},{"id":5708,"depth":488,"text":5709},{"id":5722,"depth":488,"text":5723},{"id":5755,"depth":488,"text":5756},"2026-05-28","Les détecteurs de fumée sont-ils obligatoires en Belgique ? Oui — mais les règles varient selon la région. Découvrez ce qui s'applique en Flandre, Wallonie et Bruxelles.",{},"\u002Fblog\u002Fsmoke-detector-mandatory.fr",{"title":5535,"description":5795},"detecteur-fumee-obligatoire-belgique","blog\u002Fsmoke-detector-mandatory.fr",[5802,5803,4293,5554,5584,5609,5804],"detecteur-fumee","securite-incendie","securite","BKaCFr08o7LztMJFWhHRk7KKbSnjiCpmjFqJYrsyNks",{"id":5807,"title":5808,"articleId":5809,"body":5810,"category":906,"date":6752,"description":6753,"extension":507,"lastUpdated":2234,"locale":508,"meta":6754,"navigation":510,"path":6755,"publishDate":6752,"readTime":512,"refreshInterval":913,"seo":6756,"slug":6757,"stem":6758,"tags":6759,"__hash__":6764},"blog\u002Fblog\u002Fborne-recharge-rgie.fr.md","Installer une borne de recharge selon le RGIE : Le guide complet pour la Belgique","ev-charger-installation-arei",{"type":9,"value":5811,"toc":6713},[5812,5815,5818,5822,5825,5827,5834,5838,5841,5844,5847,5849,5852,5856,5860,5925,5930,5941,5946,5954,5958,6023,6028,6039,6044,6055,6059,6066,6070,6074,6142,6148,6151,6158,6180,6187,6191,6194,6198,6209,6215,6219,6230,6236,6242,6246,6253,6257,6264,6270,6275,6277,6280,6284,6331,6335,6360,6364,6367,6378,6381,6385,6391,6395,6437,6441,6446,6460,6464,6468,6548,6604,6620,6624,6627,6631,6669,6673,6676,6678,6680,6693,6701,6705],[12,5813,5808],{"id":5814},"installer-une-borne-de-recharge-selon-le-rgie-le-guide-complet-pour-la-belgique",[16,5816,5817],{},"L'installation d'une borne de recharge (wallbox) pour véhicules électriques en Belgique est soumise à des prescriptions strictes du RGIE. L'article 7.22 du RGIE réglemente les exigences spécifiques pour l'infrastructure de recharge. Dans ce guide, nous expliquons toutes les prescriptions, exigences de câblage et mesures de protection — pour que votre installation soit conforme aux normes et passe le contrôle.",[23,5819,5821],{"id":5820},"exigences-rgie-pour-borne-de-recharge-art-722","Exigences RGIE pour borne de recharge (Art. 7.22)",[16,5823,5824],{},"Le RGIE pose les exigences de base suivantes pour les installations de bornes de recharge :",[367,5826,5126],{"id":5125},[16,5828,5829,5830,5833],{},"La borne de recharge ",[55,5831,5832],{},"doit"," disposer de son propre circuit dédié. Elle ne peut pas être raccordée à un circuit existant (par ex. prises dans le garage). Ce circuit dédié doit aller directement du coffret de distribution à la borne.",[367,5835,5837],{"id":5836},"différentiel-protection-différentielle","Différentiel (protection différentielle)",[16,5839,5840],{},"Chaque borne de recharge nécessite son propre différentiel (RCD). Le type de différentiel dépend de la borne (plus de détails ci-dessous).",[367,5842,5843],{"id":2591},"Disjoncteur",[16,5845,5846],{},"Un disjoncteur (MCB) correctement dimensionné protège le circuit de la borne contre les surcharges et les courts-circuits.",[367,5848,5162],{"id":5161},[16,5850,5851],{},"L'art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art. En pratique, un SPD central est installé dans le coffret de distribution, protégeant tous les circuits y compris celui de la borne de recharge contre les surtensions transitoires causées par la foudre ou les commutations dans le réseau.",[23,5853,5855],{"id":5854},"monophasé-vs-triphasé-quelle-borne","Monophasé vs. triphasé : Quelle borne ?",[367,5857,5859],{"id":5858},"monophasé-37-kw-ou-74-kw","Monophasé — 3,7 kW ou 7,4 kW",[28,5861,5862,5875],{},[31,5863,5864],{},[34,5865,5866,5869,5872],{},[37,5867,5868],{},"Caractéristique",[37,5870,5871],{},"3,7 kW (16A)",[37,5873,5874],{},"7,4 kW (32A)",[47,5876,5877,5886,5895,5904,5914],{},[34,5878,5879,5881,5884],{},[52,5880,1055],{},[52,5882,5883],{},"Monophasé, 230V",[52,5885,5883],{},[34,5887,5888,5891,5893],{},[52,5889,5890],{},"Intensité",[52,5892,3928],{},[52,5894,3954],{},[34,5896,5897,5899,5902],{},[52,5898,3909],{},[52,5900,5901],{},"2,5 mm²",[52,5903,3951],{},[34,5905,5906,5908,5911],{},[52,5907,5843],{},[52,5909,5910],{},"20A type C",[52,5912,5913],{},"40A type C",[34,5915,5916,5919,5922],{},[52,5917,5918],{},"Temps de charge (batterie 50 kWh)",[52,5920,5921],{},"~14 heures",[52,5923,5924],{},"~7 heures",[16,5926,5927],{},[55,5928,5929],{},"Avantages monophasé :",[444,5931,5932,5935,5938],{},[447,5933,5934],{},"Installation moins chère",[447,5936,5937],{},"Câblage plus simple",[447,5939,5940],{},"Suffisant pour la plupart des ménages (charge nocturne)",[16,5942,5943],{},[55,5944,5945],{},"Inconvénients monophasé :",[444,5947,5948,5951],{},[447,5949,5950],{},"Puissance de charge limitée",[447,5952,5953],{},"À 7,4 kW : déséquilibre de phase possible (attention lors de la déclaration)",[367,5955,5957],{"id":5956},"triphasé-11-kw-ou-22-kw","Triphasé — 11 kW ou 22 kW",[28,5959,5960,5972],{},[31,5961,5962],{},[34,5963,5964,5966,5969],{},[37,5965,5868],{},[37,5967,5968],{},"11 kW (16A)",[37,5970,5971],{},"22 kW (32A)",[47,5973,5974,5983,5993,6003,6013],{},[34,5975,5976,5978,5981],{},[52,5977,1055],{},[52,5979,5980],{},"Triphasé, 400V",[52,5982,5980],{},[34,5984,5985,5987,5990],{},[52,5986,5890],{},[52,5988,5989],{},"3x 16A",[52,5991,5992],{},"3x 32A",[34,5994,5995,5997,6000],{},[52,5996,3909],{},[52,5998,5999],{},"2,5 mm² (5G2,5)",[52,6001,6002],{},"6 mm² (5G6)",[34,6004,6005,6007,6010],{},[52,6006,5843],{},[52,6008,6009],{},"20A tripolaire type C",[52,6011,6012],{},"32A tripolaire type C",[34,6014,6015,6017,6020],{},[52,6016,5918],{},[52,6018,6019],{},"~5 heures",[52,6021,6022],{},"~2,5 heures",[16,6024,6025],{},[55,6026,6027],{},"Avantages triphasé :",[444,6029,6030,6033,6036],{},[447,6031,6032],{},"Charge nettement plus rapide",[447,6034,6035],{},"Répartition de charge équilibrée (pas de déséquilibre)",[447,6037,6038],{},"Pérenne",[16,6040,6041],{},[55,6042,6043],{},"Inconvénients triphasé :",[444,6045,6046,6049,6052],{},[447,6047,6048],{},"Installation plus coûteuse",[447,6050,6051],{},"Raccordement triphasé au coffret nécessaire",[447,6053,6054],{},"Coûts de matériel plus élevés (câbles plus épais, dispositifs de protection plus chers)",[367,6056,6058],{"id":6057},"notre-recommandation","Notre recommandation",[16,6060,6061,6062,6065],{},"Pour la plupart des maisons unifamiliales, nous recommandons une ",[55,6063,6064],{},"borne de recharge triphasée 11 kW",". Elle offre le meilleur compromis entre puissance de charge, coûts et pérennité. Un véhicule électrique est entièrement chargé en 4-5 heures pendant la nuit — cela suffit pour l'usage quotidien.",[23,6067,6069],{"id":6068},"câble-et-protection-le-bon-dimensionnement","Câble et protection : Le bon dimensionnement",[367,6071,6073],{"id":6072},"aperçu-des-sections-de-câble","Aperçu des sections de câble",[28,6075,6076,6090],{},[31,6077,6078],{},[34,6079,6080,6082,6085,6088],{},[37,6081,5352],{},[37,6083,6084],{},"Type de câble",[37,6086,6087],{},"Section",[37,6089,5843],{},[47,6091,6092,6104,6116,6129],{},[34,6093,6094,6097,6100,6102],{},[52,6095,6096],{},"3,7 kW (1P, 16A)",[52,6098,6099],{},"XVB 3G2,5",[52,6101,5901],{},[52,6103,5910],{},[34,6105,6106,6109,6112,6114],{},[52,6107,6108],{},"7,4 kW (1P, 32A)",[52,6110,6111],{},"XVB 3G6",[52,6113,3951],{},[52,6115,5913],{},[34,6117,6118,6121,6124,6126],{},[52,6119,6120],{},"11 kW (3P, 16A)",[52,6122,6123],{},"XVB 5G2,5",[52,6125,5901],{},[52,6127,6128],{},"20A 3P type C",[34,6130,6131,6134,6137,6139],{},[52,6132,6133],{},"22 kW (3P, 32A)",[52,6135,6136],{},"XVB 5G6",[52,6138,3951],{},[52,6140,6141],{},"32A 3P type C",[16,6143,6144,6147],{},[55,6145,6146],{},"Important :"," Pour de longues longueurs de câble (>15m), la section doit éventuellement être augmentée pour limiter la chute de tension (RGIE Art. 5.2.5 — variation de tension ; Art. 5.2.1.2b — choix des canalisations). Planifiez le parcours du câble à l'avance et consultez les tableaux de chute de tension en cas de doute.",[367,6149,6084],{"id":6150},"type-de-câble",[16,6152,6153,6154,6157],{},"En Belgique, on utilise habituellement du ",[55,6155,6156],{},"câble XVB"," pour les installations fixes :",[444,6159,6160,6165,6170,6175],{},[447,6161,6162,6164],{},[55,6163,6099],{}," pour monophasé 16A",[447,6166,6167,6169],{},[55,6168,6111],{}," pour monophasé 32A",[447,6171,6172,6174],{},[55,6173,6123],{}," pour triphasé 16A",[447,6176,6177,6179],{},[55,6178,6136],{}," pour triphasé 32A",[16,6181,6182,6183,6186],{},"Pour une pose en tube Preflex, des ",[55,6184,6185],{},"conducteurs VOB individuels"," sont envisageables (H07V-U), à condition que le tube soit suffisamment dimensionné.",[23,6188,6190],{"id":6189},"type-de-différentiel-le-dispositif-de-protection-le-plus-important","Type de différentiel : Le dispositif de protection le plus important",[16,6192,6193],{},"Le choix du bon différentiel est particulièrement important pour les bornes de recharge — et peut entraîner des différences de coût considérables.",[367,6195,6197],{"id":6196},"type-a-avec-capteur-de-courant-résiduel-dc-recommandé","Type A avec capteur de courant résiduel DC (recommandé)",[16,6199,6200,6201,6204,6205,6208],{},"La plupart des bornes de recharge modernes (par ex. Wallbox Pulsar Plus, ABB Terra, Easee) disposent d'un ",[55,6202,6203],{},"capteur de courant résiduel DC intégré (6 mA DC)",". Dans ce cas, un ",[55,6206,6207],{},"différentiel type A (30 mA)"," suffit, car la borne assure elle-même la protection DC.",[16,6210,6211,6214],{},[55,6212,6213],{},"Coût type A :"," ~€30-50 (bipolaire, monophasé) ou ~€50-80 (tétrapolaire, triphasé)",[367,6216,6218],{"id":6217},"type-b-si-pas-de-capteur-dc-dans-la-borne","Type B (si pas de capteur DC dans la borne)",[16,6220,6221,6222,6225,6226,6229],{},"Si votre borne ",[55,6223,6224],{},"n'a pas"," de capteur de courant résiduel DC intégré, vous avez besoin d'un ",[55,6227,6228],{},"différentiel type B",". Celui-ci détecte également les courants de défaut continus (DC), qui peuvent survenir avec les chargeurs AC\u002FDC.",[16,6231,6232,6235],{},[55,6233,6234],{},"Coût type B :"," ~€200-400",[16,6237,6238,6241],{},[55,6239,6240],{},"Conseil :"," Lors de l'achat de la borne, vérifiez qu'un capteur de courant résiduel DC est intégré. Cela vous fait économiser €120-370 sur le différentiel (type B ~€200-400 au lieu du type A ~€30-80, selon le nombre de pôles) !",[367,6243,6245],{"id":6244},"type-a-si-alternative","Type A-SI (alternative)",[16,6247,6248,6249,6252],{},"Certains fabricants proposent aussi un ",[55,6250,6251],{},"différentiel type A-SI"," (sélectif, résistant aux courants impulsionnels), qui peut être un bon choix pour les bornes afin d'éviter les déclenchements intempestifs dus aux courants d'appel.",[23,6254,6256],{"id":6255},"protection-contre-les-surtensions-spd-centralisée-pour-toute-linstallation","Protection contre les surtensions (SPD) — centralisée pour toute l'installation",[16,6258,6259,6260,6263],{},"L'art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art. En pratique, un ",[55,6261,6262],{},"SPD (parafoudre)"," est installé dans le coffret de distribution, protégeant tous les appareils raccordés y compris la borne de recharge contre les surtensions transitoires. Le RGIE ne mentionne pas de « Type 2 » spécifique — la désignation de type provient de la norme produit (IEC 61643-11).",[16,6265,6266,6269],{},[55,6267,6268],{},"Coût SPD :"," ~€50-80",[16,6271,6272,6274],{},[55,6273,6146],{}," Le SPD doit être protégé par un fusible amont (fusible gR ou MCB). Respectez les prescriptions du fabricant.",[23,6276,5304],{"id":5303},[16,6278,6279],{},"En Belgique, les installations de bornes de recharge à partir d'une certaine puissance doivent être déclarées au gestionnaire de réseau compétent :",[367,6281,6283],{"id":6282},"obligation-de-déclaration-à-partir-de-575-kw","Obligation de déclaration à partir de 5,75 kW",[28,6285,6286,6298],{},[31,6287,6288],{},[34,6289,6290,6293,6295],{},[37,6291,6292],{},"Gestionnaire de réseau",[37,6294,5647],{},[37,6296,6297],{},"Obligation",[47,6299,6300,6311,6321],{},[34,6301,6302,6306,6308],{},[52,6303,6304],{},[55,6305,1242],{},[52,6307,5555],{},[52,6309,6310],{},"À partir de 5,75 kW",[34,6312,6313,6317,6319],{},[52,6314,6315],{},[55,6316,1243],{},[52,6318,5585],{},[52,6320,6310],{},[34,6322,6323,6327,6329],{},[52,6324,6325],{},[55,6326,1244],{},[52,6328,5610],{},[52,6330,6310],{},[16,6332,6333],{},[55,6334,4859],{},[444,6336,6337,6343,6349,6354],{},[447,6338,6339,6342],{},[55,6340,6341],{},"3,7 kW monophasé :"," Pas de déclaration nécessaire",[447,6344,6345,6348],{},[55,6346,6347],{},"7,4 kW monophasé :"," Déclaration requise",[447,6350,6351,6348],{},[55,6352,6353],{},"11 kW triphasé :",[447,6355,6356,6359],{},[55,6357,6358],{},"22 kW triphasé :"," Déclaration requise + éventuellement vérification de capacité réseau",[367,6361,6363],{"id":6362},"comment-déclarer","Comment déclarer ?",[16,6365,6366],{},"La déclaration se fait en ligne via le portail du gestionnaire de réseau concerné :",[444,6368,6369,6372,6375],{},[447,6370,6371],{},"Fluvius : via Mijn Fluvius",[447,6373,6374],{},"ORES : via le portail client ORES",[447,6376,6377],{},"Sibelga : via le portail Sibelga",[16,6379,6380],{},"Ayez les informations suivantes à portée de main : numéro EAN de votre compteur, puissance de la borne, date d'installation souhaitée.",[23,6382,6384],{"id":6383},"mettre-à-jour-le-schéma-unifilaire","Mettre à jour le schéma unifilaire",[16,6386,6387,6388,6390],{},"Après l'installation d'une borne de recharge, le schéma unifilaire de votre installation électrique ",[55,6389,5832],{}," être mis à jour. La borne est représentée comme un départ propre dans le schéma :",[367,6392,6394],{"id":6393},"que-doit-figurer-dans-le-schéma","Que doit figurer dans le schéma ?",[937,6396,6397,6403,6409,6414,6419,6425,6431],{},[447,6398,6399,6402],{},[55,6400,6401],{},"Circuit propre"," depuis le coffret de distribution",[447,6404,6405,6408],{},[55,6406,6407],{},"Différentiel"," avec indication du type (A ou B)",[447,6410,6411,6413],{},[55,6412,5843],{}," avec courant nominal",[447,6415,6416,6418],{},[55,6417,3051],{}," (protection contre les surtensions)",[447,6420,6421,6424],{},[55,6422,6423],{},"Symbole de borne de recharge"," avec indication de puissance",[447,6426,6427,6430],{},[55,6428,6429],{},"Désignation du câble"," (par ex. XVB 5G2,5)",[447,6432,6433,6436],{},[55,6434,6435],{},"Attribution des phases"," (en triphasé : L1\u002FL2\u002FL3)",[367,6438,6440],{"id":6439},"planelec-simplifie-les-choses","PlanElec simplifie les choses",[16,6442,6443,6445],{},[55,6444,42],{}," aide à documenter une borne de recharge dans le projet :",[444,6447,6448,6451,6454,6457],{},[447,6449,6450],{},"Un symbole de borne est disponible pour la représentation sur le plan",[447,6452,6453],{},"L'auto-contrôle peut signaler certaines données prises en charge sur le circuit, le différentiel et le parafoudre",[447,6455,6456],{},"L'attribution des phases peut être saisie directement",[447,6458,6459],{},"L'export PDF reprend les données saisies dans le projet",[23,6461,6463],{"id":6462},"exemple-dinstallation-avec-aperçu-des-coûts","Exemple d'installation avec aperçu des coûts",[367,6465,6467],{"id":6466},"scénario-borne-11-kw-triphasée-10m-de-câble","Scénario : Borne 11 kW (triphasée), 10m de câble",[28,6469,6470,6479],{},[31,6471,6472],{},[34,6473,6474,6477],{},[37,6475,6476],{},"Matériel",[37,6478,2020],{},[47,6480,6481,6489,6497,6505,6513,6520,6528,6536],{},[34,6482,6483,6486],{},[52,6484,6485],{},"Borne de recharge (par ex. Pulsar Plus, avec capteur DC)",[52,6487,6488],{},"€600-900",[34,6490,6491,6494],{},[52,6492,6493],{},"Câble XVB 5G2,5 (10m)",[52,6495,6496],{},"€30-40",[34,6498,6499,6502],{},[52,6500,6501],{},"Différentiel type A 30mA tétrapolaire (capteur DC dans la borne)",[52,6503,6504],{},"€50-80",[34,6506,6507,6510],{},[52,6508,6509],{},"Disjoncteur 20A tripolaire type C",[52,6511,6512],{},"€25-40",[34,6514,6515,6518],{},[52,6516,6517],{},"SPD type 2 tripolaire",[52,6519,6504],{},[34,6521,6522,6525],{},[52,6523,6524],{},"Fusible amont SPD",[52,6526,6527],{},"€10-15",[34,6529,6530,6533],{},[52,6531,6532],{},"Petit matériel (bornes, fixation, passe-câble)",[52,6534,6535],{},"€20-30",[34,6537,6538,6543],{},[52,6539,6540],{},[55,6541,6542],{},"Matériel total",[52,6544,6545],{},[55,6546,6547],{},"€785-1.185",[28,6549,6550,6559],{},[31,6551,6552],{},[34,6553,6554,6557],{},[37,6555,6556],{},"Main d'œuvre",[37,6558,2020],{},[47,6560,6561,6569,6576,6584,6592],{},[34,6562,6563,6566],{},[52,6564,6565],{},"Installation par électricien (4-6 h)",[52,6567,6568],{},"€200-360",[34,6570,6571,6574],{},[52,6572,6573],{},"Mise à jour schéma unifilaire (avec PlanElec)",[52,6575,2040],{},[34,6577,6578,6581],{},[52,6579,6580],{},"Contrôle (si nécessaire)",[52,6582,6583],{},"€150-200",[34,6585,6586,6589],{},[52,6587,6588],{},"Déclaration gestionnaire de réseau",[52,6590,6591],{},"€0 (gratuit)",[34,6593,6594,6599],{},[52,6595,6596],{},[55,6597,6598],{},"Main d'œuvre total",[52,6600,6601],{},[55,6602,6603],{},"€399-609",[28,6605,6606],{},[31,6607,6608],{},[34,6609,6610,6615],{},[37,6611,6612],{},[55,6613,6614],{},"Coût total",[37,6616,6617],{},[55,6618,6619],{},"€1.184-1.794",[367,6621,6623],{"id":6622},"astuce-économie-acheter-le-matériel-soi-même","Astuce économie : Acheter le matériel soi-même",[16,6625,6626],{},"Vous pouvez économiser considérablement en achetant le matériel vous-même et en ne faisant réaliser que l'installation par l'électricien. Vérifiez le marquage CE et achetez chez des grossistes en électricité spécialisés (par ex. Rexel, Cebeo, Solar).",[23,6628,6630],{"id":6629},"éviter-les-erreurs-courantes","Éviter les erreurs courantes",[937,6632,6633,6639,6645,6651,6657,6663],{},[447,6634,6635,6638],{},[55,6636,6637],{},"Pas de circuit dédié :"," Brancher la borne sur une prise existante est non seulement dangereux, mais contraire au RGIE.",[447,6640,6641,6644],{},[55,6642,6643],{},"Mauvais type de différentiel :"," Sans capteur DC dans la borne, un type B est obligatoire.",[447,6646,6647,6650],{},[55,6648,6649],{},"Parafoudre manquant :"," La protection contre les surtensions (SPD) est souvent oubliée — le contrôleur le remarquera.",[447,6652,6653,6656],{},[55,6654,6655],{},"Pas de schéma unifilaire mis à jour :"," Toute modification de l'installation doit être documentée dans le schéma.",[447,6658,6659,6662],{},[55,6660,6661],{},"Pas de déclaration au gestionnaire de réseau :"," À partir de 5,75 kW, la déclaration est obligatoire.",[447,6664,6665,6668],{},[55,6666,6667],{},"Section de câble trop faible :"," Surtout pour les longs parcours (>15m), surveillez la chute de tension.",[23,6670,6672],{"id":6671},"conclusion","Conclusion",[16,6674,6675],{},"L'installation d'une borne de recharge en Belgique est tout à fait réalisable, mais exige le respect des prescriptions RGIE selon l'article 7.22. Les points essentiels : circuit dédié, bon type de différentiel, protection contre les surtensions (Art. 4.5.1) et schéma unifilaire mis à jour. Avec une planification soigneuse et les bons matériaux, vous passerez le contrôle sans problème.",[3625,6677],{},[23,6679,2178],{"id":2177},[444,6681,6682,6687],{},[447,6683,6684],{},[262,6685,6686],{"href":1199},"Calculer la chute de tension d'une longue alimentation",[447,6688,6689],{},[262,6690,6692],{"href":6691},"\u002Ffr\u002Fblog\u002Fcomparatif-cout-soi-meme-vs-electricien","Comparatif coût : dessiner soi-même vs. électricien",[444,6694,6695],{},[447,6696,6697],{},[262,6698,6700],{"href":6699},"\u002Ffr\u002Fblog\u002Fplanelec-vs-excel-papier","PlanElec vs. Excel\u002Fpapier",[23,6702,6704],{"id":6703},"documenter-votre-borne-dans-le-schéma-unifilaire","Documenter votre borne dans le schéma unifilaire",[16,6706,477,6707,6709,6710],{},[55,6708,42],{},", documentez votre borne dans le schéma unifilaire et exportez le projet en PDF. L'auto-contrôle aide à la préparation, mais ne remplace ni le dimensionnement professionnel ni le contrôle officiel. ",[262,6711,4216],{"href":483,"rel":6712},[266],{"title":487,"searchDepth":488,"depth":488,"links":6714},[6715,6721,6726,6730,6735,6736,6740,6744,6748,6749,6750,6751],{"id":5820,"depth":488,"text":5821,"children":6716},[6717,6718,6719,6720],{"id":5125,"depth":497,"text":5126},{"id":5836,"depth":497,"text":5837},{"id":2591,"depth":497,"text":5843},{"id":5161,"depth":497,"text":5162},{"id":5854,"depth":488,"text":5855,"children":6722},[6723,6724,6725],{"id":5858,"depth":497,"text":5859},{"id":5956,"depth":497,"text":5957},{"id":6057,"depth":497,"text":6058},{"id":6068,"depth":488,"text":6069,"children":6727},[6728,6729],{"id":6072,"depth":497,"text":6073},{"id":6150,"depth":497,"text":6084},{"id":6189,"depth":488,"text":6190,"children":6731},[6732,6733,6734],{"id":6196,"depth":497,"text":6197},{"id":6217,"depth":497,"text":6218},{"id":6244,"depth":497,"text":6245},{"id":6255,"depth":488,"text":6256},{"id":5303,"depth":488,"text":5304,"children":6737},[6738,6739],{"id":6282,"depth":497,"text":6283},{"id":6362,"depth":497,"text":6363},{"id":6383,"depth":488,"text":6384,"children":6741},[6742,6743],{"id":6393,"depth":497,"text":6394},{"id":6439,"depth":497,"text":6440},{"id":6462,"depth":488,"text":6463,"children":6745},[6746,6747],{"id":6466,"depth":497,"text":6467},{"id":6622,"depth":497,"text":6623},{"id":6629,"depth":488,"text":6630},{"id":6671,"depth":488,"text":6672},{"id":2177,"depth":488,"text":2178},{"id":6703,"depth":488,"text":6704},"2026-05-25","Tout sur les exigences RGIE pour l'installation de bornes de recharge en Belgique : section de câble, protection différentielle, parafoudre, déclaration au gestionnaire de réseau et schéma unifilaire. Avec aperçu des coûts.",{},"\u002Fblog\u002Fborne-recharge-rgie.fr",{"title":5808,"description":6753},"borne-recharge-rgie","blog\u002Fborne-recharge-rgie.fr",[1245,6760,521,6761,6762,6763,1241,518],"wallbox","voiture électrique","installation","protection différentielle","hT8F2deX4KUZ-sOhNWZfUreNFeSzSDp6DJkpgLp4kMQ",{"id":6766,"title":6767,"articleId":6768,"body":6769,"category":504,"date":7438,"description":7439,"extension":507,"lastUpdated":7438,"locale":508,"meta":7440,"navigation":510,"path":7441,"publishDate":7438,"readTime":7442,"refreshInterval":913,"seo":7443,"slug":7444,"stem":7445,"tags":7446,"__hash__":7450},"blog\u002Fblog\u002Fcomparatif-cout-soi-meme-vs-electricien.fr.md","Comparatif coût : Dessiner son schéma unifilaire soi-même vs. faire appel à un électricien","cost-comparison-diy-vs-electrician",{"type":9,"value":6770,"toc":7414},[6771,6774,6777,6781,6847,6851,6854,6858,6890,6894,6897,6914,6918,6923,6943,6947,6950,6954,6961,6965,6972,6976,6979,6983,6986,6990,6994,6999,7053,7058,7098,7101,7104,7108,7112,7164,7168,7204,7207,7211,7215,7265,7269,7304,7307,7310,7314,7317,7343,7347,7350,7380,7383,7385,7388,7391,7393,7395,7401,7405],[12,6772,6767],{"id":6773},"comparatif-coût-dessiner-son-schéma-unifilaire-soi-même-vs-faire-appel-à-un-électricien",[16,6775,6776],{},"Si vous avez besoin d'un contrôle électrique en Belgique, vous devez disposer d'un schéma unifilaire et d'un plan de situation à jour. La question se pose naturellement : le faire soi-même ou faire appel à un électricien ? Nous faisons le calcul pour trois scénarios typiques.",[23,6778,6780],{"id":6779},"tldr-comparatif-des-coûts-en-un-coup-dœil","TL;DR — Comparatif des coûts en un coup d'œil",[28,6782,6783,6799],{},[31,6784,6785],{},[34,6786,6787,6790,6793,6796],{},[37,6788,6789],{},"Scénario",[37,6791,6792],{},"Électricien",[37,6794,6795],{},"PlanElec (soi-même)",[37,6797,6798],{},"Économie",[47,6800,6801,6818,6832],{},[34,6802,6803,6809,6812,6815],{},[52,6804,6805,6808],{},[55,6806,6807],{},"Plan existant"," (contrôle)",[52,6810,6811],{},"€269-450",[52,6813,6814],{},"Early Access actuellement 0 €",[52,6816,6817],{},"selon le projet",[34,6819,6820,6825,6828,6830],{},[52,6821,6822,6824],{},[55,6823,4583],{}," (15-20 circuits)",[52,6826,6827],{},"€400-600",[52,6829,6814],{},[52,6831,6817],{},[34,6833,6834,6840,6843,6845],{},[52,6835,6836,6839],{},[55,6837,6838],{},"Vente immobilière"," (urgent)",[52,6841,6842],{},"€350-600+",[52,6844,6814],{},[52,6846,6817],{},[23,6848,6850],{"id":6849},"que-coûte-lélectricien","Que coûte l'électricien ?",[16,6852,6853],{},"Les prix pour la réalisation d'un schéma unifilaire par un électricien en Belgique varient selon la région, l'entreprise et l'ampleur de l'installation :",[367,6855,6857],{"id":6856},"prix-typiques-état-2026","Prix typiques (état 2026)",[444,6859,6860,6866,6872,6878,6884],{},[447,6861,6862,6865],{},[55,6863,6864],{},"Relevé sur place + schéma unifilaire :"," €269-450",[447,6867,6868,6871],{},[55,6869,6870],{},"Schéma unifilaire + plan de situation :"," €350-600",[447,6873,6874,6877],{},[55,6875,6876],{},"Taux horaire électricien :"," €40-60\u002Fheure (hors TVA)",[447,6879,6880,6883],{},[55,6881,6882],{},"Supplément urgent :"," +30-50% pour les commandes pressantes",[447,6885,6886,6889],{},[55,6887,6888],{},"Frais de déplacement :"," €30-50 forfaitaire ou par déplacement",[367,6891,6893],{"id":6892},"relevé-sur-place","Relevé sur place",[16,6895,6896],{},"Pour un schéma unifilaire correct, l'électricien doit relever l'intégralité de votre installation sur place. Cela prend pour un logement moyen 2 à 4 heures :",[444,6898,6899,6902,6905,6908,6911],{},[447,6900,6901],{},"Documenter le coffret de distribution",[447,6903,6904],{},"Identifier et suivre tous les circuits",[447,6906,6907],{},"Noter les dispositifs de protection (différentiel, disjoncteurs)",[447,6909,6910],{},"Vérifier les sections de câble",[447,6912,6913],{},"Relever les appareils dans chaque pièce",[23,6915,6917],{"id":6916},"que-coûte-planelec","Que coûte PlanElec ?",[16,6919,6920,6922],{},[55,6921,42],{}," est actuellement en Early Access gratuit :",[444,6924,6925,6931,6937],{},[447,6926,6927,6930],{},[55,6928,6929],{},"Aucun frais de produit actuellement"," et aucun paiement actif",[447,6932,6933,6936],{},[55,6934,6935],{},"Disponible :"," planification du projet, éditeur de tableau, schéma unifilaire et plan de situation en PDF, rapport d'auto-contrôle indicatif",[447,6938,6939,6942],{},[55,6940,6941],{},"Encore sur la feuille de route :"," liste de matériel, dossier complet et devis",[23,6944,6946],{"id":6945},"coûts-cachés-chez-lélectricien","Coûts cachés chez l'électricien",[16,6948,6949],{},"Au-delà du simple honoraire, il y a souvent des coûts cachés qui augmentent encore le prix :",[367,6951,6953],{"id":6952},"temps-dattente","Temps d'attente",[16,6955,6956,6957,6960],{},"Les bons électriciens sont très demandés en Belgique. Comptez ",[55,6958,6959],{},"2 à 4 semaines d'attente"," avant le rendez-vous. Pour les affaires urgentes (par ex. vente immobilière avec deadline de contrôle), cela peut devenir problématique — et le supplément urgent fait grimper le prix.",[367,6962,6964],{"id":6963},"frais-de-déplacement","Frais de déplacement",[16,6966,6967,6968,6971],{},"De nombreuses entreprises facturent un forfait de déplacement de ",[55,6969,6970],{},"€30-50",", surtout en zones rurales.",[367,6973,6975],{"id":6974},"les-modifications-coûtent-extra","Les modifications coûtent extra",[16,6977,6978],{},"Quelque chose a changé depuis le relevé ? Un circuit oublié ? Chez la plupart des électriciens, les modifications au plan finalisé coûtent un supplément — souvent à nouveau le taux horaire.",[367,6980,6982],{"id":6981},"deuxième-rendez-vous","Deuxième rendez-vous",[16,6984,6985],{},"Parfois une seule visite ne suffit pas. Pour les installations complexes ou une documentation incomplète, un second rendez-vous sur place peut être nécessaire.",[23,6987,6989],{"id":6988},"_3-exemples-de-calcul-avec-des-chiffres-concrets","3 exemples de calcul avec des chiffres concrets",[367,6991,6993],{"id":6992},"exemple-1-plan-existant-pour-contrôle-maison-unifamiliale-12-circuits","Exemple 1 : Plan existant pour contrôle (maison unifamiliale, ~12 circuits)",[16,6995,6996],{},[55,6997,6998],{},"Chez l'électricien :",[28,7000,7001,7009],{},[31,7002,7003],{},[34,7004,7005,7007],{},[37,7006,2017],{},[37,7008,2020],{},[47,7010,7011,7019,7027,7034,7041],{},[34,7012,7013,7016],{},[52,7014,7015],{},"Relevé sur place (3 h)",[52,7017,7018],{},"€150",[34,7020,7021,7024],{},[52,7022,7023],{},"Création schéma unifilaire",[52,7025,7026],{},"€120",[34,7028,7029,7031],{},[52,7030,159],{},[52,7032,7033],{},"€80",[34,7035,7036,7038],{},[52,7037,6964],{},[52,7039,7040],{},"€40",[34,7042,7043,7048],{},[52,7044,7045],{},[55,7046,7047],{},"Total",[52,7049,7050],{},[55,7051,7052],{},"€390",[16,7054,7055],{},[55,7056,7057],{},"Avec PlanElec :",[28,7059,7060,7068],{},[31,7061,7062],{},[34,7063,7064,7066],{},[37,7065,2017],{},[37,7067,2020],{},[47,7069,7070,7078,7086],{},[34,7071,7072,7075],{},[52,7073,7074],{},"PlanElec Early Access",[52,7076,7077],{},"0 €",[34,7079,7080,7083],{},[52,7081,7082],{},"Temps de travail personnel (~2-3 h)",[52,7084,7085],{},"€0*",[34,7087,7088,7093],{},[52,7089,7090],{},[55,7091,7092],{},"Total hors temps personnel",[52,7094,7095],{},[55,7096,7097],{},"0 € de frais produit",[16,7099,7100],{},"*Votre temps n'est pas gratuit. Selon le projet, des coûts de relevé, de vérification professionnelle et de contrôle peuvent aussi s'ajouter.",[16,7102,7103],{},"L'économie dépend du travail personnel et de l'accompagnement professionnel requis.",[367,7105,7107],{"id":7106},"exemple-2-construction-neuve-18-circuits-appartement-3-chambres","Exemple 2 : Construction neuve (18 circuits, appartement 3 chambres)",[16,7109,7110],{},[55,7111,6998],{},[28,7113,7114,7122],{},[31,7115,7116],{},[34,7117,7118,7120],{},[37,7119,2017],{},[37,7121,2020],{},[47,7123,7124,7132,7139,7146,7153],{},[34,7125,7126,7129],{},[52,7127,7128],{},"Planification et conseil",[52,7130,7131],{},"€200",[34,7133,7134,7136],{},[52,7135,7023],{},[52,7137,7138],{},"€180",[34,7140,7141,7143],{},[52,7142,159],{},[52,7144,7145],{},"€100",[34,7147,7148,7151],{},[52,7149,7150],{},"Frais de déplacement (2 rdv)",[52,7152,7033],{},[34,7154,7155,7159],{},[52,7156,7157],{},[55,7158,7047],{},[52,7160,7161],{},[55,7162,7163],{},"€560",[16,7165,7166],{},[55,7167,7057],{},[28,7169,7170,7178],{},[31,7171,7172],{},[34,7173,7174,7176],{},[37,7175,2017],{},[37,7177,2020],{},[47,7179,7180,7186,7193],{},[34,7181,7182,7184],{},[52,7183,7074],{},[52,7185,7077],{},[34,7187,7188,7191],{},[52,7189,7190],{},"Temps de travail personnel (~3-4 h)",[52,7192,7085],{},[34,7194,7195,7200],{},[52,7196,7197],{},[55,7198,7199],{},"Total hors temps personnel et vérification professionnelle",[52,7201,7202],{},[55,7203,7097],{},[16,7205,7206],{},"Sans relevé du projet, aucune économie fixe ne peut être calculée sérieusement.",[367,7208,7210],{"id":7209},"exemple-3-vente-immobilière-urgent-contrôle-dans-2-semaines","Exemple 3 : Vente immobilière (urgent, contrôle dans 2 semaines)",[16,7212,7213],{},[55,7214,6998],{},[28,7216,7217,7225],{},[31,7218,7219],{},[34,7220,7221,7223],{},[37,7222,2017],{},[37,7224,2020],{},[47,7226,7227,7234,7240,7248,7254],{},[34,7228,7229,7232],{},[52,7230,7231],{},"Supplément urgent (+40%)",[52,7233,254],{},[34,7235,7236,7238],{},[52,7237,7015],{},[52,7239,7131],{},[34,7241,7242,7245],{},[52,7243,7244],{},"Schéma unifilaire + plan de situation",[52,7246,7247],{},"€250",[34,7249,7250,7252],{},[52,7251,6964],{},[52,7253,7040],{},[34,7255,7256,7260],{},[52,7257,7258],{},[55,7259,7047],{},[52,7261,7262],{},[55,7263,7264],{},"€490+",[16,7266,7267],{},[55,7268,7057],{},[28,7270,7271,7279],{},[31,7272,7273],{},[34,7274,7275,7277],{},[37,7276,2017],{},[37,7278,2020],{},[47,7280,7281,7287,7294],{},[34,7282,7283,7285],{},[52,7284,7074],{},[52,7286,7077],{},[34,7288,7289,7292],{},[52,7290,7291],{},"Temps de travail personnel (week-end)",[52,7293,7085],{},[34,7295,7296,7300],{},[52,7297,7298],{},[55,7299,7092],{},[52,7301,7302],{},[55,7303,7097],{},[16,7305,7306],{},"L'économie réelle dépend du projet et de l'accompagnement professionnel nécessaire.",[16,7308,7309],{},"Lors d'une vente immobilière, le facteur temps joue également : avec PlanElec, vous pouvez commencer immédiatement, au lieu d'attendre 2 à 4 semaines pour l'électricien.",[23,7311,7313],{"id":7312},"quand-faire-appel-à-lélectricien","Quand faire appel à l'électricien ?",[16,7315,7316],{},"Il existe des situations où un électricien est le meilleur choix :",[444,7318,7319,7325,7331,7337],{},[447,7320,7321,7324],{},[55,7322,7323],{},"Installations industrielles complexes :"," Les installations triphasées avec des dizaines de circuits, variateurs de fréquence ou installations de compensation dépassent le cadre de PlanElec.",[447,7326,7327,7330],{},[55,7328,7329],{},"Triphasé avec beaucoup de circuits :"," À partir de 30+ circuits avec alimentation triphasée, la planification peut devenir exigeante.",[447,7332,7333,7336],{},[55,7334,7335],{},"Si vous vous sentez incertain :"," Si vous ne connaissez pas votre installation ou ne vous sentez pas à l'aise avec l'électrotechnique, l'aide professionnelle est judicieuse.",[447,7338,7339,7342],{},[55,7340,7341],{},"Anciennes installations sans documentation :"," Pour les maisons très anciennes (avant 1981) sans aucun document, le relevé peut être complexe.",[23,7344,7346],{"id":7345},"dessiner-soi-même-est-ce-vraiment-possible","Dessiner soi-même — est-ce vraiment possible ?",[16,7348,7349],{},"PlanElec peut aussi être utilisé par des non-spécialistes pour la documentation technique. Il ne remplace toutefois ni les compétences professionnelles, ni un électricien, ni un organisme de contrôle :",[937,7351,7352,7358,7363,7369,7375],{},[447,7353,7354,7357],{},[55,7355,7356],{},"Assistant pas à pas"," vous guide tout au long du processus",[447,7359,7360,7362],{},[55,7361,3491],{}," pour une représentation cohérente",[447,7364,7365,7368],{},[55,7366,7367],{},"Mise en page automatique"," limitant le dessin manuel",[447,7370,7371,7374],{},[55,7372,7373],{},"Auto-contrôle RGIE"," signalant certains problèmes pris en charge",[447,7376,7377,7379],{},[55,7378,3502],{}," fournissant une base pour la vérification professionnelle",[16,7381,7382],{},"Ce que vous devez savoir : quels appareils se trouvent dans quelle pièce et comment votre coffret de distribution est configuré. Vous pouvez documenter cela vous-même sur place.",[23,7384,6672],{"id":6671},[16,7386,7387],{},"PlanElec est actuellement gratuit en Early Access, mais la vérification professionnelle et le contrôle officiel restent des coûts séparés. Une économie fixe ne peut donc pas être promise.",[16,7389,7390],{},"Pour les particuliers, PlanElec est une option technique complémentaire. Si l'installation ne peut pas être relevée ou évaluée en toute sécurité, faites appel à une entreprise d'électricité.",[3625,7392],{},[23,7394,2178],{"id":2177},[444,7396,7397],{},[447,7398,7399],{},[262,7400,6700],{"href":6699},[23,7402,7404],{"id":7403},"économisez-sur-votre-schéma-unifilaire","Économisez sur votre schéma unifilaire",[16,7406,7407,7408,7410,7411],{},"Créez votre projet électrique avec ",[55,7409,42],{}," pendant l'Early Access actuellement gratuit, directement dans le navigateur. Le rapport d'auto-contrôle est indicatif et ne remplace pas le contrôle officiel. ",[262,7412,4216],{"href":483,"rel":7413},[266],{"title":487,"searchDepth":488,"depth":488,"links":7415},[7416,7417,7421,7422,7428,7433,7434,7435,7436,7437],{"id":6779,"depth":488,"text":6780},{"id":6849,"depth":488,"text":6850,"children":7418},[7419,7420],{"id":6856,"depth":497,"text":6857},{"id":6892,"depth":497,"text":6893},{"id":6916,"depth":488,"text":6917},{"id":6945,"depth":488,"text":6946,"children":7423},[7424,7425,7426,7427],{"id":6952,"depth":497,"text":6953},{"id":6963,"depth":497,"text":6964},{"id":6974,"depth":497,"text":6975},{"id":6981,"depth":497,"text":6982},{"id":6988,"depth":488,"text":6989,"children":7429},[7430,7431,7432],{"id":6992,"depth":497,"text":6993},{"id":7106,"depth":497,"text":7107},{"id":7209,"depth":497,"text":7210},{"id":7312,"depth":488,"text":7313},{"id":7345,"depth":488,"text":7346},{"id":6671,"depth":488,"text":6672},{"id":2177,"depth":488,"text":2178},{"id":7403,"depth":488,"text":7404},"2026-05-19","Combien coûte un schéma unifilaire par un électricien ? Et avec PlanElec soi-même ? Trois exemples de calcul pour plan existant, construction neuve et vente immobilière en Belgique.",{},"\u002Fblog\u002Fcomparatif-cout-soi-meme-vs-electricien.fr","5 min",{"title":6767,"description":7439},"comparatif-cout-soi-meme-vs-electricien","blog\u002Fcomparatif-cout-soi-meme-vs-electricien.fr",[7447,4662,518,7448,42,7449,1241],"coûts","faire soi-même","contrôle","OEHgKdGT-lYA_PakjmKrnqzkmuE268DwGdOcbqp0ZKg",{"id":7452,"title":7453,"articleId":7454,"body":7455,"category":504,"date":7843,"description":7844,"extension":507,"lastUpdated":2234,"locale":508,"meta":7845,"navigation":510,"path":7846,"publishDate":7843,"readTime":7442,"refreshInterval":913,"seo":7847,"slug":7848,"stem":7849,"tags":7850,"__hash__":7854},"blog\u002Fblog\u002Fplanelec-vs-excel-papier.fr.md","PlanElec vs. Excel & papier : Pourquoi les schémas unifilaires numériques sont meilleurs","planelec-vs-excel-paper",{"type":9,"value":7456,"toc":7815},[7457,7460,7463,7467,7599,7603,7606,7609,7613,7617,7620,7624,7627,7631,7634,7638,7641,7645,7649,7652,7656,7659,7663,7666,7670,7673,7677,7681,7684,7688,7691,7695,7698,7714,7718,7721,7725,7728,7732,7735,7740,7762,7767,7771,7781,7784,7788,7791,7793,7796,7799,7801,7803,7807],[12,7458,7453],{"id":7459},"planelec-vs-excel-papier-pourquoi-les-schémas-unifilaires-numériques-sont-meilleurs",[16,7461,7462],{},"De nombreux propriétaires et même certains électriciens utilisent encore un stylo et du papier ou Excel lorsqu'ils doivent créer un schéma unifilaire. Cela semble gratuit et simple au premier abord — mais comporte des risques considérables. Dans cette comparaison, nous montrons pourquoi un outil spécialisé comme PlanElec est le meilleur choix.",[23,7464,7466],{"id":7465},"tldr-comparaison-en-un-coup-dœil","TL;DR — Comparaison en un coup d'œil",[28,7468,7469,7483],{},[31,7470,7471],{},[34,7472,7473,7475,7477,7480],{},[37,7474,39],{},[37,7476,42],{},[37,7478,7479],{},"Excel\u002FWord",[37,7481,7482],{},"Papier",[47,7484,7485,7498,7514,7529,7542,7556,7572,7586],{},[34,7486,7487,7491,7493,7496],{},[52,7488,7489],{},[55,7490,2020],{},[52,7492,2040],{},[52,7494,7495],{},"\"Gratuit\"",[52,7497,7495],{},[34,7499,7500,7505,7508,7511],{},[52,7501,7502],{},[55,7503,7504],{},"Symboles RGIE",[52,7506,7507],{},"✅ Corrects",[52,7509,7510],{},"❌ Aucun",[52,7512,7513],{},"❌ Souvent faux",[34,7515,7516,7521,7524,7527],{},[52,7517,7518],{},[55,7519,7520],{},"Mise en page auto",[52,7522,7523],{},"✅",[52,7525,7526],{},"❌",[52,7528,7526],{},[34,7530,7531,7535,7538,7540],{},[52,7532,7533],{},[55,7534,7373],{},[52,7536,7537],{},"✅ Indicatif",[52,7539,7526],{},[52,7541,7526],{},[34,7543,7544,7548,7551,7554],{},[52,7545,7546],{},[55,7547,3502],{},[52,7549,7550],{},"✅ Centralisé",[52,7552,7553],{},"⚠️ Manuel",[52,7555,7526],{},[34,7557,7558,7563,7566,7569],{},[52,7559,7560],{},[55,7561,7562],{},"Modifications",[52,7564,7565],{},"✅ À tout moment",[52,7567,7568],{},"⚠️ Laborieux",[52,7570,7571],{},"❌ Redessiner",[34,7573,7574,7579,7582,7584],{},[52,7575,7576],{},[55,7577,7578],{},"Contrôle officiel",[52,7580,7581],{},"Requis séparément",[52,7583,7581],{},[52,7585,7581],{},[34,7587,7588,7592,7595,7597],{},[52,7589,7590],{},[55,7591,159],{},[52,7593,7594],{},"✅ Intégré",[52,7596,7526],{},[52,7598,7526],{},[23,7600,7602],{"id":7601},"la-réalité-beaucoup-dessinent-encore-à-la-main","La réalité : Beaucoup dessinent encore à la main",[16,7604,7605],{},"Bien que nous soyons en 2026, la réalité en Belgique est souvent encore analogique. Lors de rénovations, d'extensions ou de la vente d'un bien immobilier, les propriétaires doivent présenter un schéma unifilaire et un plan de situation à jour. Beaucoup se tournent alors vers ce qu'ils connaissent : une feuille de papier ou un tableau Excel.",[16,7607,7608],{},"Le problème ? Le contrôleur lors du contrôle électrique attend des plans conformes aux normes — et ceux-ci sont pratiquement impossibles à réaliser sur papier ou dans Excel.",[23,7610,7612],{"id":7611},"problèmes-avec-le-papier","Problèmes avec le papier",[367,7614,7616],{"id":7615},"non-conforme-aux-normes","Non conforme aux normes",[16,7618,7619],{},"Le RGIE (Règlement Général sur les Installations Électriques) prescrit certains symboles (Tableau 2.23, basé sur IEC 60617). Les symboles dessinés à la main ne correspondent presque jamais aux exigences normatives. Un contrôleur peut refuser le plan si les symboles ne sont pas corrects.",[367,7621,7623],{"id":7622},"difficile-à-modifier","Difficile à modifier",[16,7625,7626],{},"Vous avez fait une erreur ou oublié une prise ? Avec un plan dessiné à la main, vous devez redessiner l'intégralité du schéma. Pour des installations complexes avec 20+ circuits, c'est un investissement en temps énorme.",[367,7628,7630],{"id":7629},"illisible","Illisible",[16,7632,7633],{},"L'écriture manuscrite est subjective. Ce qui est clair pour vous peut être illisible pour le contrôleur. Les corrections rayées aggravent encore la situation.",[367,7635,7637],{"id":7636},"risque-de-refus-au-contrôle","Risque de refus au contrôle",[16,7639,7640],{},"De plus en plus de contrôleurs n'acceptent les plans dessinés à la main qu'à contrecœur. Le RGIE (Art. 9.1.2) ne prescrit pas que les plans doivent être réalisés de manière numérique. L'essentiel est que la documentation soit lisible, complète et conforme aux normes. Un plan soigneusement dessiné à la main avec des symboles RGIE corrects est autorisé selon le RGIE — mais le risque de contestation en cas de dessins manuscrits illisibles ou erronés reste élevé.",[23,7642,7644],{"id":7643},"problèmes-avec-excel","Problèmes avec Excel",[367,7646,7648],{"id":7647},"pas-de-symboles-rgie","Pas de symboles RGIE",[16,7650,7651],{},"Excel ne connaît pas les symboles électriques. Vous devriez insérer chaque symbole comme image ou le reconstituer laborieusement avec des formes. Le résultat a l'air non professionnel et ne respecte pas la norme.",[367,7653,7655],{"id":7654},"pas-de-mise-en-page-automatique","Pas de mise en page automatique",[16,7657,7658],{},"Un schéma unifilaire a une structure claire : interrupteur principal, différentiels, disjoncteurs, consommateurs — le tout dans une hiérarchie définie. Dans Excel, vous devez construire cette structure manuellement et l'adapter à chaque modification.",[367,7660,7662],{"id":7661},"pas-de-validation","Pas de validation",[16,7664,7665],{},"Excel ne vérifie pas si votre schéma est conforme au RGIE. Manque-t-il un différentiel ? La section de câble est-elle trop petite ? Avez-vous trop de circuits par RCD ? Excel ne le sait pas — mais le contrôleur, si.",[367,7667,7669],{"id":7668},"problèmes-de-mise-en-forme","Problèmes de mise en forme",[16,7671,7672],{},"Les schémas plus grands ne tiennent pas sur une page A4. L'aperçu d'impression d'Excel est tristement célèbre pour ses sauts de page inattendus et ses contenus coupés.",[23,7674,7676],{"id":7675},"avantages-de-planelec-en-détail","Avantages de PlanElec en détail",[367,7678,7680],{"id":7679},"symboles-conformes-aux-normes","Symboles conformes aux normes",[16,7682,7683],{},"PlanElec fournit un catalogue de symboles électriques pour le contexte de planification belge. Le professionnel doit déterminer les symboles et données requis pour le projet concret.",[367,7685,7687],{"id":7686},"mise-en-page-automatique-goethals-jacobs","Mise en page automatique (Goethals-Jacobs)",[16,7689,7690],{},"PlanElec déduit de la topologie saisie une représentation structurée avec jeux de barres, protections et récepteurs. La justesse professionnelle dépend des données du projet.",[367,7692,7694],{"id":7693},"auto-contrôle-rgie-assisté","Auto-contrôle RGIE assisté",[16,7696,7697],{},"L'auto-contrôle signale certaines erreurs de planification prises en charge, notamment pour les protections et le dimensionnement des câbles. Il ne constitue pas une preuve complète de conformité. L'état interne des règles date actuellement du 31.03.2025 ; les modifications de 2026 restent à intégrer.",[444,7699,7700,7703,7706,7708,7711],{},[447,7701,7702],{},"Nombre maximum de circuits par RCD : max. 8 (Art. 4.2.4.3b)",[447,7704,7705],{},"Sections de câble adaptées au disjoncteur",[447,7707,5162],{},[447,7709,7710],{},"Protection zones salle de bain (Art. 7.1)",[447,7712,7713],{},"Et bien plus encore",[367,7715,7717],{"id":7716},"modifiable-à-tout-moment","Modifiable à tout moment",[16,7719,7720],{},"Prise oubliée ? Ajouter un circuit ? Avec PlanElec, vous ajoutez des modifications en secondes. La mise en page s'adapte automatiquement — pas besoin de redessiner, pas de chaos de mise en forme.",[367,7722,7724],{"id":7723},"export-pdf-professionnel","Export PDF professionnel",[16,7726,7727],{},"Un clic et vous obtenez un PDF professionnel au format A4 paysage — avec cartouche, pagination et symboles conformes aux normes. Exactement ce que le contrôleur attend.",[23,7729,7731],{"id":7730},"largument-du-prix-gratuit-a-un-coût","L'argument du prix : \"Gratuit\" a un coût",[16,7733,7734],{},"Papier et Excel semblent gratuits. Mais faisons le calcul :",[16,7736,7737],{},[55,7738,7739],{},"Scénario : Refus au contrôle",[937,7741,7742,7745,7751,7757],{},[447,7743,7744],{},"Vous dessinez votre schéma sur papier ou dans Excel : €0",[447,7746,7747,7748],{},"Le contrôleur refuse le plan : recontrôle ",[55,7749,7750],{},"€80-120",[447,7752,7753,7754],{},"Vous engagez un électricien pour refaire le plan : ",[55,7755,7756],{},"€150-300",[447,7758,7759,7760],{},"Nouveau contrôle : ",[55,7761,6583],{},[16,7763,7764],{},[55,7765,7766],{},"Coût total en cas de refus : €380-620",[16,7768,7769],{},[55,7770,7057],{},[937,7772,7773,7778],{},[447,7774,7775,7776],{},"Créer le schéma unifilaire avec PlanElec : ",[55,7777,2040],{},[447,7779,7780],{},"Faire vérifier la documentation par un professionnel et effectuer séparément le contrôle officiel",[16,7782,7783],{},"Les coûts de la vérification professionnelle et du contrôle officiel restent indépendants de l'outil de planification utilisé. Une économie totale fixe ne peut donc pas être promise sérieusement.",[23,7785,7787],{"id":7786},"quand-le-papier-fonctionne-encore","Quand le papier fonctionne encore",[16,7789,7790],{},"En toute honnêteté : pour des installations très simples (par ex. un seul circuit dans un abri de jardin), certains contrôleurs acceptent encore un plan proprement dessiné à la main. Mais dès que l'installation comporte plus de 3-4 circuits, le papier devient confus et source d'erreurs.",[23,7792,6672],{"id":6671},[16,7794,7795],{},"Le papier et Excel ne sont pas des outils adaptés à la création de schémas unifilaires. L'absence de symboles normalisés, la mise en page manuelle et l'absence de validation annulent rapidement l'avantage supposé du coût — au plus tard lors du contrôle.",[16,7797,7798],{},"PlanElec réunit le plan, la topologie électrique et la planification du tableau et exporte aujourd'hui le schéma unifilaire et le plan de situation en PDF. Le rapport d'auto-contrôle intégré est indicatif et ne remplace pas le contrôle officiel.",[3625,7800],{},[23,7802,2178],{"id":2177},[23,7804,7806],{"id":7805},"fini-le-papier-et-excel","Fini le papier et Excel !",[16,7808,477,7809,7811,7812],{},[55,7810,42],{},", planifiez le plan, la topologie électrique et le tableau dans un même projet, puis exportez le schéma unifilaire et le plan de situation en PDF. L'auto-contrôle aide à la préparation et ne remplace pas le contrôle officiel. ",[262,7813,4216],{"href":483,"rel":7814},[266],{"title":487,"searchDepth":488,"depth":488,"links":7816},[7817,7818,7819,7825,7831,7838,7839,7840,7841,7842],{"id":7465,"depth":488,"text":7466},{"id":7601,"depth":488,"text":7602},{"id":7611,"depth":488,"text":7612,"children":7820},[7821,7822,7823,7824],{"id":7615,"depth":497,"text":7616},{"id":7622,"depth":497,"text":7623},{"id":7629,"depth":497,"text":7630},{"id":7636,"depth":497,"text":7637},{"id":7643,"depth":488,"text":7644,"children":7826},[7827,7828,7829,7830],{"id":7647,"depth":497,"text":7648},{"id":7654,"depth":497,"text":7655},{"id":7661,"depth":497,"text":7662},{"id":7668,"depth":497,"text":7669},{"id":7675,"depth":488,"text":7676,"children":7832},[7833,7834,7835,7836,7837],{"id":7679,"depth":497,"text":7680},{"id":7686,"depth":497,"text":7687},{"id":7693,"depth":497,"text":7694},{"id":7716,"depth":497,"text":7717},{"id":7723,"depth":497,"text":7724},{"id":7730,"depth":488,"text":7731},{"id":7786,"depth":488,"text":7787},{"id":6671,"depth":488,"text":6672},{"id":2177,"depth":488,"text":2178},{"id":7805,"depth":488,"text":7806},"2026-05-05","Comparaison entre PlanElec et la création de schémas unifilaires avec Excel ou sur papier. Pourquoi les plans dessinés à la main échouent au contrôle et pourquoi les outils numériques font gagner temps et argent.",{},"\u002Fblog\u002Fplanelec-vs-excel-papier.fr",{"title":7453,"description":7844},"planelec-vs-excel-papier","blog\u002Fplanelec-vs-excel-papier.fr",[42,7851,7852,7853,518,521,7449],"Excel","papier","comparaison","KR4Xvx7nF9EVN5fzCLNQWS52hqbKEGYHwuUMq1ncNhI",{"id":7856,"title":7857,"articleId":7858,"body":7859,"category":906,"date":8761,"description":8762,"extension":507,"lastUpdated":2234,"locale":508,"meta":8763,"navigation":510,"path":8764,"publishDate":8761,"readTime":512,"refreshInterval":913,"seo":8765,"slug":8766,"stem":8767,"tags":8768,"__hash__":8773},"blog\u002Fblog\u002Fpv-system-documentation.fr.md","Panneaux solaires dans le schéma : Documentation et prescriptions RGIE pour les installations PV","pv-system-documentation",{"type":9,"value":7860,"toc":8729},[7861,7864,7867,7869,7873,7876,7896,7901,7912,7914,7918,7921,7925,7931,7935,8015,8017,8021,8025,8080,8095,8099,8151,8155,8211,8222,8224,8226,8230,8267,8271,8303,8307,8326,8330,8357,8359,8363,8367,8374,8394,8401,8405,8412,8430,8432,8443,8445,8449,8452,8456,8462,8466,8469,8485,8497,8499,8503,8514,8631,8635,8642,8663,8669,8671,8675,8678,8692,8694,8696,8717,8719],[12,7862,7857],{"id":7863},"panneaux-solaires-dans-le-schéma-documentation-et-prescriptions-rgie-pour-les-installations-pv",[16,7865,7866],{},"Une installation photovoltaïque (PV) sur le toit n'est pas seulement un investissement pour l'avenir en Belgique — elle doit aussi être correctement documentée et déclarée auprès du gestionnaire de réseau de distribution (GRD). Dans cet article, vous apprendrez comment l'installation PV est représentée dans le schéma unifilaire, quels dispositifs de protection sont nécessaires et ce qu'il faut savoir lors de la déclaration.",[3625,7868],{},[23,7870,7872],{"id":7871},"pourquoi-la-documentation-est-elle-obligatoire","Pourquoi la documentation est-elle obligatoire ?",[16,7874,7875],{},"Toute installation PV doit apparaître dans la documentation électrique de votre bâtiment — c'est-à-dire :",[937,7877,7878,7884,7890],{},[447,7879,7880,7883],{},[55,7881,7882],{},"Schéma unifilaire :"," L'installation PV avec tous ses composants (modules, onduleur, protections) doit être dessinée.",[447,7885,7886,7889],{},[55,7887,7888],{},"Plan de situation :"," La position de l'onduleur et du sectionneur DC doit être marquée.",[447,7891,7892,7895],{},[55,7893,7894],{},"Déclaration au GRD :"," L'installation doit être enregistrée auprès du gestionnaire de réseau compétent.",[16,7897,7898],{},[55,7899,7900],{},"Sans documentation correcte :",[444,7902,7903,7906,7909],{},[447,7904,7905],{},"Le contrôle RGIE échoue.",[447,7907,7908],{},"Le GRD peut refuser le raccordement au réseau.",[447,7910,7911],{},"Le droit à la compensation ou au tarif prosommateur est perdu.",[3625,7913],{},[23,7915,7917],{"id":7916},"que-doit-contenir-le-schéma-unifilaire","Que doit contenir le schéma unifilaire ?",[16,7919,7920],{},"L'installation PV est représentée comme une branche distincte dans le schéma unifilaire. Le flux de signal va des modules jusqu'au point d'injection :",[367,7922,7924],{"id":7923},"chaîne-de-composants","Chaîne de composants",[2881,7926,7929],{"className":7927,"code":7928,"language":2886},[2884],"Modules PV (strings)\n   │\n   ├── Câble DC (câble solaire, par ex. 6 mm²)\n   │\n   ├── Sectionneur DC (interrupteur pompiers)\n   │\n   ├── Parafoudre DC (côté DC)\n   │\n   └── Onduleur (Inverter)\n         │\n         ├── Parafoudre AC (côté AC)\n         │\n         ├── Disjoncteur pour circuit PV (par ex. C20A)\n         │\n         ├── Différentiel 30 mA Type A (ou Type B pour onduleur sans transformateur)\n         │\n         └── Point d'injection (raccordement au tableau principal)\n",[576,7930,7928],{"__ignoreMap":487},[367,7932,7934],{"id":7933},"symboles-dans-le-schéma","Symboles dans le schéma",[28,7936,7937,7949],{},[31,7938,7939],{},[34,7940,7941,7943,7946],{},[37,7942,2974],{},[37,7944,7945],{},"Symbole RGIE",[37,7947,7948],{},"Remarque",[47,7950,7951,7962,7973,7984,7995,8005],{},[34,7952,7953,7956,7959],{},[52,7954,7955],{},"Module PV",[52,7957,7958],{},"Rectangle avec symbole soleil",[52,7960,7961],{},"Indiquer nombre et puissance (par ex. « 12x 400 Wc »)",[34,7963,7964,7967,7970],{},[52,7965,7966],{},"Onduleur",[52,7968,7969],{},"Rectangle avec « ~ » et « = »",[52,7971,7972],{},"Entrée DC \u002F Sortie AC",[34,7974,7975,7978,7981],{},[52,7976,7977],{},"Sectionneur DC",[52,7979,7980],{},"Symbole interrupteur avec « DC »",[52,7982,7983],{},"Coupure pompiers",[34,7985,7986,7989,7992],{},[52,7987,7988],{},"Parafoudre",[52,7990,7991],{},"Symbole éclair avec terre",[52,7993,7994],{},"Côté DC ET côté AC",[34,7996,7997,7999,8002],{},[52,7998,5843],{},[52,8000,8001],{},"Symbole MCB standard",[52,8003,8004],{},"La caractéristique B suffit pour la plupart des onduleurs modernes avec soft-start ; C uniquement en cas de courant d'appel élevé (consultez les spécifications du fabricant)",[34,8006,8007,8009,8012],{},[52,8008,6407],{},[52,8010,8011],{},"Symbole RCD standard",[52,8013,8014],{},"Indiquer le type (A ou B)",[3625,8016],{},[23,8018,8020],{"id":8019},"dispositifs-de-protection-pour-installations-pv","Dispositifs de protection pour installations PV",[367,8022,8024],{"id":8023},"côté-dc-entre-modules-et-onduleur","Côté DC (entre modules et onduleur)",[28,8026,8027,8040],{},[31,8028,8029],{},[34,8030,8031,8034,8037],{},[37,8032,8033],{},"Dispositif",[37,8035,8036],{},"Fonction",[37,8038,8039],{},"Obligatoire ?",[47,8041,8042,8054,8067],{},[34,8043,8044,8048,8051],{},[52,8045,8046],{},[55,8047,7977],{},[52,8049,8050],{},"Mise hors tension des modules PV",[52,8052,8053],{},"Recommandé \u002F bonne pratique (souvent une exigence du fabricant ou du GRD ; ne découle pas de l'Art. 7.112)",[34,8055,8056,8061,8064],{},[52,8057,8058],{},[55,8059,8060],{},"Parafoudre DC",[52,8062,8063],{},"Protection contre les surtensions côté DC",[52,8065,8066],{},"Art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art ; en pratique recommandé pour le PV, notamment pour modules à >10 m de l'onduleur ou câbles en toiture",[34,8068,8069,8074,8077],{},[52,8070,8071],{},[55,8072,8073],{},"Fusibles de string",[52,8075,8076],{},"Protection en cas de strings multiples",[52,8078,8079],{},"À partir de 3+ strings parallèles",[1759,8081,8082],{},[16,8083,8084,8087,8088,268,8091,8094],{},[55,8085,8086],{},"Sectionneur DC :"," Un dispositif de sectionnement DC relève des bonnes pratiques (et est exigé par de nombreux fabricants d'onduleurs ou GRD) ; il ne découle toutefois pas de l'Art. 7.112. Il devrait être ",[55,8089,8090],{},"facilement accessible",[55,8092,8093],{},"clairement identifié",", et peut également être installé à l'intérieur du bâtiment, à condition de rester repérable.",[367,8096,8098],{"id":8097},"côté-ac-entre-onduleur-et-tableau","Côté AC (entre onduleur et tableau)",[28,8100,8101,8111],{},[31,8102,8103],{},[34,8104,8105,8107,8109],{},[37,8106,8033],{},[37,8108,8036],{},[37,8110,8039],{},[47,8112,8113,8126,8138],{},[34,8114,8115,8120,8123],{},[52,8116,8117],{},[55,8118,8119],{},"Parafoudre AC",[52,8121,8122],{},"Protection contre les surtensions côté AC",[52,8124,8125],{},"Art. 4.5.1 — protection contre les surtensions selon les règles de l'art",[34,8127,8128,8133,8136],{},[52,8129,8130],{},[55,8131,8132],{},"Disjoncteur (caractéristique C)",[52,8134,8135],{},"Protection contre court-circuit et surcharge",[52,8137,150],{},[34,8139,8140,8145,8148],{},[52,8141,8142],{},[55,8143,8144],{},"Différentiel 30 mA",[52,8146,8147],{},"Protection différentielle",[52,8149,8150],{},"Recommandé (un RCD dédié par circuit AC PV n'est pas imposé par le RGIE ; le circuit doit être protégé par les mesures de protection générales)",[367,8152,8154],{"id":8153},"quel-type-de-différentiel","Quel type de différentiel ?",[28,8156,8157,8170],{},[31,8158,8159],{},[34,8160,8161,8164,8167],{},[37,8162,8163],{},"Type d'onduleur",[37,8165,8166],{},"Type de différentiel",[37,8168,8169],{},"Pourquoi ?",[47,8171,8172,8186,8199],{},[34,8173,8174,8180,8183],{},[52,8175,8176,8179],{},[55,8177,8178],{},"Avec transformateur"," (séparation galvanique)",[52,8181,8182],{},"Type A",[52,8184,8185],{},"Pas de courant de défaut DC possible",[34,8187,8188,8194,8196],{},[52,8189,8190,8193],{},[55,8191,8192],{},"Sans transformateur"," (sans séparation galvanique)",[52,8195,2395],{},[52,8197,8198],{},"Courants de défaut DC possibles",[34,8200,8201,8206,8208],{},[52,8202,8203],{},[55,8204,8205],{},"Avec RCMU intégrée",[52,8207,8182],{},[52,8209,8210],{},"La RCMU détecte les courants DC en interne",[1759,8212,8213],{},[16,8214,8215,8217,8218,8221],{},[55,8216,6240],{}," Les onduleurs modernes ont souvent une ",[55,8219,8220],{},"RCMU"," (Residual Current Monitoring Unit) intégrée qui détecte les courants de défaut DC. Dans ce cas, un différentiel Type A suffit. Vérifiez les spécifications du fabricant.",[3625,8223],{},[23,8225,5304],{"id":5303},[367,8227,8229],{"id":8228},"grd-compétents-en-belgique","GRD compétents en Belgique",[28,8231,8232,8240],{},[31,8233,8234],{},[34,8235,8236,8238],{},[37,8237,5647],{},[37,8239,6292],{},[47,8241,8242,8250,8259],{},[34,8243,8244,8248],{},[52,8245,8246],{},[55,8247,5555],{},[52,8249,1242],{},[34,8251,8252,8256],{},[52,8253,8254],{},[55,8255,5585],{},[52,8257,8258],{},"ORES, RESA, REW",[34,8260,8261,8265],{},[52,8262,8263],{},[55,8264,5610],{},[52,8266,1244],{},[367,8268,8270],{"id":8269},"déroulement-de-la-déclaration","Déroulement de la déclaration",[937,8272,8273,8279,8285,8291,8297],{},[447,8274,8275,8278],{},[55,8276,8277],{},"Avant l'installation :"," Demande de raccordement \u002F augmentation de capacité auprès du GRD (souvent nécessaire pour installations > 5 kVA).",[447,8280,8281,8284],{},[55,8282,8283],{},"Après l'installation :"," Soumettre la déclaration de conformité de l'installateur.",[447,8286,8287,8290],{},[55,8288,8289],{},"Contrôle RGIE :"," Par un organisme de contrôle agréé (par ex. BTV, Vinçotte, AIB).",[447,8292,8293,8296],{},[55,8294,8295],{},"Changement de compteur :"," Passage au compteur bidirectionnel (numérique).",[447,8298,8299,8302],{},[55,8300,8301],{},"Activation :"," Le GRD autorise l'injection.",[367,8304,8306],{"id":8305},"documents-requis","Documents requis",[444,8308,8309,8312,8314,8317,8320,8323],{},[447,8310,8311],{},"Schéma unifilaire (avec installation PV)",[447,8313,159],{},[447,8315,8316],{},"Fiche technique des modules PV",[447,8318,8319],{},"Fiche technique de l'onduleur",[447,8321,8322],{},"Déclaration de conformité de l'installateur",[447,8324,8325],{},"Rapport de contrôle RGIE",[367,8327,8329],{"id":8328},"délais","Délais",[444,8331,8332,8342,8351],{},[447,8333,8334,8337,8338,8341],{},[55,8335,8336],{},"Fluvius (Flandre) :"," Déclaration dans les ",[55,8339,8340],{},"30 jours"," après la mise en service.",[447,8343,8344,8347,8348,8350],{},[55,8345,8346],{},"ORES (Wallonie) :"," Déclaration ",[55,8349,2894],{}," la mise en service recommandée.",[447,8352,8353,8356],{},[55,8354,8355],{},"Sibelga (Bruxelles) :"," Pré-déclaration pour installations > 5 kVA.",[3625,8358],{},[23,8360,8362],{"id":8361},"autoconsommation-vs-injection","Autoconsommation vs. injection",[367,8364,8366],{"id":8365},"flandre-compteur-numérique","Flandre : Compteur numérique",[16,8368,8369,8370,8373],{},"Depuis 2021, tous les compteurs analogiques en Flandre sont progressivement remplacés par des ",[55,8371,8372],{},"compteurs numériques",". Le compteur numérique mesure la consommation et l'injection séparément :",[444,8375,8376,8382,8388],{},[447,8377,8378,8381],{},[55,8379,8380],{},"L'autoconsommation"," est directement déduite (pas de frais de réseau).",[447,8383,8384,8387],{},[55,8385,8386],{},"L'injection"," est rémunérée au prix du marché actuel (tarif d'injection).",[447,8389,8390,8393],{},[55,8391,8392],{},"Le prélèvement réseau"," est facturé au tarif normal.",[1759,8395,8396],{},[16,8397,8398,8400],{},[55,8399,6240],{}," Maximisez l'autoconsommation grâce à une gestion intelligente (pompe à chaleur, boiler, borne de recharge pendant la journée).",[367,8402,8404],{"id":8403},"wallonie-tarif-prosommateur","Wallonie : Tarif prosommateur",[16,8406,8407,8408,8411],{},"En Wallonie, depuis 2024, le ",[55,8409,8410],{},"tarif prosommateur"," s'applique :",[444,8413,8414,8421,8424],{},[447,8415,8416,8417,8420],{},"Compensation entre injection et consommation sur ",[55,8418,8419],{},"base annuelle"," (encore jusqu'à fin 2030).",[447,8422,8423],{},"À partir de 2031, transition progressive vers la mesure en temps réel.",[447,8425,8426,8427,567],{},"Les frais de réseau sont calculés sur la base de la ",[55,8428,8429],{},"consommation annuelle",[367,8431,5610],{"id":5609},[444,8433,8434,8440],{},[447,8435,8436,8439],{},[55,8437,8438],{},"Système de certificats verts"," : Certificats verts par MWh produit.",[447,8441,8442],{},"Compensation via le compteur possible (selon le type de compteur).",[3625,8444],{},[23,8446,8448],{"id":8447},"intégration-de-batterie-dans-le-schéma","Intégration de batterie dans le schéma",[16,8450,8451],{},"Si vous ajoutez un stockage par batterie, le schéma s'enrichit :",[367,8453,8455],{"id":8454},"composants-supplémentaires","Composants supplémentaires",[2881,8457,8460],{"className":8458,"code":8459,"language":2886},[2884],"Onduleur (onduleur hybride)\n   │\n   ├── Sortie AC → Tableau principal (comme ci-dessus)\n   │\n   └── Raccordement batterie DC\n         │\n         ├── Sectionneur batterie (DC)\n         │\n         ├── BMS (Système de Gestion de Batterie, interne)\n         │\n         └── Stockage batterie (par ex. 10 kWh LFP)\n",[576,8461,8459],{"__ignoreMap":487},[367,8463,8465],{"id":8464},"commutation-de-secours-optionnel","Commutation de secours (optionnel)",[16,8467,8468],{},"Pour un système capable de fournir du courant de secours :",[444,8470,8471,8476,8482],{},[447,8472,8473,8475],{},[55,8474,5272],{}," (automatique ou manuel) : isole la maison du réseau et l'alimente depuis la batterie.",[447,8477,8478,8479,567],{},"Doit être dessiné dans le schéma unifilaire comme ",[55,8480,8481],{},"commutateur",[447,8483,8484],{},"Les circuits de secours doivent être identifiés.",[1759,8486,8487],{},[16,8488,8489,8492,8493,8496],{},[55,8490,8491],{},"Prescription RGIE :"," Pour les systèmes de secours, il faut garantir qu'",[55,8494,8495],{},"aucune réinjection dans le réseau"," n'a lieu lorsque le réseau est coupé (protection anti-îlotage).",[3625,8498],{},[23,8500,8502],{"id":8501},"règles-spéciales-rgie-pour-le-pv-art-7112","Règles spéciales RGIE pour le PV (Art. 7.112)",[16,8504,8505,8506,8509,8510,8513],{},"Le RGIE consacre une section propre aux installations photovoltaïques domestiques à basse tension ",[55,8507,8508],{},"jusqu'à 10 kVA"," — ",[55,8511,8512],{},"Art. 7.112"," (ces règles spéciales ne s'appliquent pas aux installations > 10 kVA). Les mesures particulières prévues à l'Art. 7.112.2 sont : la mise à disposition de la documentation visée à la Section 9.1.2, l'identification des conducteurs à courant continu et des conducteurs actifs à courant alternatif, les panneaux d'avertissement (« Ne pas couper en charge » \u002F « L'installation électrique est toujours sous tension ») et la mise à la terre des cadres des modules. En complément, il existe d'autres bonnes pratiques et exigences des fabricants\u002FGRD :",[28,8515,8516,8529],{},[31,8517,8518],{},[34,8519,8520,8523,8526],{},[37,8521,8522],{},"Règle",[37,8524,8525],{},"Détails",[37,8527,8528],{},"Base",[47,8530,8531,8544,8556,8568,8580,8593,8605,8618],{},[34,8532,8533,8538,8541],{},[52,8534,8535],{},[55,8536,8537],{},"Identification conducteurs",[52,8539,8540],{},"Identifier les conducteurs à courant continu et les conducteurs actifs à courant alternatif",[52,8542,8543],{},"Art. 7.112.2",[34,8545,8546,8551,8554],{},[52,8547,8548],{},[55,8549,8550],{},"Panneaux d'avertissement",[52,8552,8553],{},"« Ne pas couper en charge » et « L'installation électrique est toujours sous tension » (ou équiv.)",[52,8555,8543],{},[34,8557,8558,8563,8566],{},[52,8559,8560],{},[55,8561,8562],{},"Mise à la terre des cadres",[52,8564,8565],{},"Conducteur de protection ≥ 2,5 mm² (avec) ou ≥ 4 mm² (sans protection mécanique)",[52,8567,8543],{},[34,8569,8570,8574,8577],{},[52,8571,8572],{},[55,8573,7977],{},[52,8575,8576],{},"Facilement accessible, clairement identifié",[52,8578,8579],{},"Bonne pratique \u002F fabricant",[34,8581,8582,8587,8590],{},[52,8583,8584],{},[55,8585,8586],{},"Cheminement câbles DC",[52,8588,8589],{},"Séparer des câbles AC (goulotte\u002Ftube dédié)",[52,8591,8592],{},"Bonne pratique \u002F CEI",[34,8594,8595,8600,8603],{},[52,8596,8597],{},[55,8598,8599],{},"Classe de protection câble",[52,8601,8602],{},"Câble DC min. classe II (double isolation)",[52,8604,8592],{},[34,8606,8607,8612,8615],{},[52,8608,8609],{},[55,8610,8611],{},"Protection foudre",[52,8613,8614],{},"Pour bâtiments avec paratonnerre : intégrer le PV dans le concept de protection foudre",[52,8616,8617],{},"Bonne pratique",[34,8619,8620,8625,8628],{},[52,8621,8622],{},[55,8623,8624],{},"Fixation toiture",[52,8626,8627],{},"Pas de prescription RGIE, mais droit de la construction (charge vent, statique)",[52,8629,8630],{},"Droit de la construction",[367,8632,8634],{"id":8633},"signalisation-sur-le-bâtiment","Signalisation sur le bâtiment",[16,8636,8637,8638,8641],{},"Selon le RGIE, un ",[55,8639,8640],{},"panneau d'avertissement"," doit être apposé sur le bâtiment indiquant la présence de l'installation PV :",[444,8643,8644,8651,8656],{},[447,8645,8646,8647,8650],{},"Au ",[55,8648,8649],{},"coffret de comptage"," ou tableau principal",[447,8652,8646,8653],{},[55,8654,8655],{},"sectionneur DC",[447,8657,8658,8659,8662],{},"À l'",[55,8660,8661],{},"entrée du bâtiment"," (information pompiers)",[16,8664,8665,8666],{},"Texte : ",[258,8667,8668],{},"« Attention : Installation photovoltaïque. Une tension DC peut être présente même lorsque le réseau est coupé. »",[3625,8670],{},[23,8672,8674],{"id":8673},"planelec-pv-dans-le-schéma-unifilaire","PlanElec : PV dans le schéma unifilaire",[16,8676,8677],{},"Avec PlanElec, vous pouvez documenter votre installation PV directement dans le schéma unifilaire :",[444,8679,8680,8683,8686,8689],{},[447,8681,8682],{},"Ajouter les modules PV comme source",[447,8684,8685],{},"Placer l'onduleur et les dispositifs de protection",[447,8687,8688],{},"Auto-contrôle assisté pour les protections et données saisies",[447,8690,8691],{},"Export PDF pour examen ultérieur par un professionnel, le GRD ou l'organisme de contrôle",[3625,8693],{},[23,8695,2178],{"id":2177},[444,8697,8698,8703,8708,8712],{},[447,8699,8700],{},[262,8701,8702],{"href":451},"Créer un schéma unifilaire en Belgique",[447,8704,8705],{},[262,8706,8707],{"href":463},"Planifier un tableau électrique : Conception et dimensionnement",[447,8709,8710],{},[262,8711,4200],{"href":565},[447,8713,8714],{},[262,8715,8716],{"href":856},"Contrôle électrique en Belgique",[3625,8718],{},[16,8720,8721],{},[258,8722,8723,8724,8726,8727],{},"Documentez l'onduleur, les protections et le stockage batterie avec ",[55,8725,42],{}," dans le schéma unifilaire. L'auto-contrôle est indicatif ; faites vérifier les documents avant leur remise. ",[262,8728,4216],{"href":1216},{"title":487,"searchDepth":488,"depth":488,"links":8730},[8731,8732,8736,8741,8747,8752,8756,8759,8760],{"id":7871,"depth":488,"text":7872},{"id":7916,"depth":488,"text":7917,"children":8733},[8734,8735],{"id":7923,"depth":497,"text":7924},{"id":7933,"depth":497,"text":7934},{"id":8019,"depth":488,"text":8020,"children":8737},[8738,8739,8740],{"id":8023,"depth":497,"text":8024},{"id":8097,"depth":497,"text":8098},{"id":8153,"depth":497,"text":8154},{"id":5303,"depth":488,"text":5304,"children":8742},[8743,8744,8745,8746],{"id":8228,"depth":497,"text":8229},{"id":8269,"depth":497,"text":8270},{"id":8305,"depth":497,"text":8306},{"id":8328,"depth":497,"text":8329},{"id":8361,"depth":488,"text":8362,"children":8748},[8749,8750,8751],{"id":8365,"depth":497,"text":8366},{"id":8403,"depth":497,"text":8404},{"id":5609,"depth":497,"text":5610},{"id":8447,"depth":488,"text":8448,"children":8753},[8754,8755],{"id":8454,"depth":497,"text":8455},{"id":8464,"depth":497,"text":8465},{"id":8501,"depth":488,"text":8502,"children":8757},[8758],{"id":8633,"depth":497,"text":8634},{"id":8673,"depth":488,"text":8674},{"id":2177,"depth":488,"text":2178},"2026-04-21","Guide complet pour la documentation d'une installation PV dans le schéma unifilaire. Dispositifs de protection, déclaration au GRD, intégration batterie et RGIE Art. 7.112.",{},"\u002Fblog\u002Fpv-system-documentation.fr",{"title":7857,"description":8762},"panneaux-solaires-schema","blog\u002Fpv-system-documentation.fr",[8769,1247,518,521,8770,8771,8772,1242],"PV","onduleur","gestionnaire de réseau","batterie","QXOevRotXr7uERV5mXXUajTFn5myFFFVgC3O5HKdVfQ",{"id":8775,"title":8776,"articleId":8777,"body":8778,"category":906,"date":9664,"description":9665,"extension":507,"lastUpdated":2234,"locale":508,"meta":9666,"navigation":510,"path":9667,"publishDate":9664,"readTime":512,"refreshInterval":913,"seo":9668,"slug":9669,"stem":9670,"tags":9671,"__hash__":9674},"blog\u002Fblog\u002Fold-building-arei-part8.fr.md","Ancien bâtiment et RGIE Partie 8 : Règles spéciales pour les installations existantes","old-building-arei-part8",{"type":9,"value":8779,"toc":9627},[8780,8783,8790,8792,8796,8803,8814,8821,8823,8827,8834,8838,8841,8845,8852,8856,8882,8890,8892,8896,8899,8903,8940,8944,8980,8992,8996,8999,9027,9031,9037,9041,9062,9066,9069,9071,9075,9082,9086,9179,9183,9186,9212,9214,9218,9222,9228,9232,9239,9250,9254,9324,9335,9337,9341,9346,9350,9357,9377,9381,9399,9401,9405,9412,9416,9430,9434,9445,9449,9460,9464,9526,9528,9532,9586,9588,9590,9614,9616],[12,8781,8776],{"id":8782},"ancien-bâtiment-et-rgie-partie-8-règles-spéciales-pour-les-installations-existantes",[16,8784,8785,8786,8789],{},"Toute installation électrique en Belgique ne doit pas forcément répondre aux dernières prescriptions du RGIE. Pour les bâtiments plus anciens, la ",[55,8787,8788],{},"Partie 8"," constitue un ensemble de règles spécifiques qui tolère certaines dérogations par rapport au standard actuel — tant qu'il n'existe pas de danger immédiat. Cet article explique quand la Partie 8 s'applique, ce qui est autorisé et où se trouvent les limites.",[3625,8791],{},[23,8793,8795],{"id":8794},"quest-ce-que-la-partie-8","Qu'est-ce que la Partie 8 ?",[16,8797,8798,8799,8802],{},"La Partie 8 du RGIE (Règlement Général sur les Installations Électriques) est une ",[55,8800,8801],{},"réglementation spéciale pour les installations existantes"," qui ont été réalisées et réceptionnées avant l'entrée en vigueur du RGIE actuel.",[16,8804,8805,8806,8809,8810,8813],{},"Le principe de base : tant qu'une installation fonctionne de manière ",[55,8807,8808],{},"sûre"," et ne représente ",[55,8811,8812],{},"aucun danger immédiat",", elle n'a pas à être entièrement mise aux normes actuelles — même si elle ne répond pas à toutes les prescriptions en vigueur.",[1759,8815,8816],{},[16,8817,8818,8820],{},[55,8819,6146],{}," La Partie 8 n'est pas un blanc-seing. Elle définit clairement quelles dérogations sont tolérées et lesquelles ne le sont pas.",[3625,8822],{},[23,8824,8826],{"id":8825},"quand-la-partie-8-sapplique-t-elle","Quand la Partie 8 s'applique-t-elle ?",[16,8828,8829,8830,8833],{},"La Partie 8 s'applique aux installations qui remplissent ",[55,8831,8832],{},"l'une"," des conditions suivantes :",[367,8835,8837],{"id":8836},"condition-1-installation-avant-le-01101981","Condition 1 : Installation avant le 01.10.1981",[16,8839,8840],{},"Les installations réalisées avant le 1er octobre 1981 (date d'entrée en vigueur du RGIE original) tombent en principe sous la Partie 8.",[367,8842,8844],{"id":8843},"condition-2-réceptionnée-sous-lancien-rgie","Condition 2 : Réceptionnée sous l'ancien RGIE",[16,8846,8847,8848,8851],{},"Les installations qui ont été réceptionnées sous une version antérieure du RGIE et qui n'ont ",[55,8849,8850],{},"pas été substantiellement modifiées"," depuis la dernière réception.",[367,8853,8855],{"id":8854},"quest-ce-quune-modification-substantielle","Qu'est-ce qu'une « modification substantielle » ?",[444,8857,8858,8864,8870,8876],{},[447,8859,8860,8861],{},"Ajout de ",[55,8862,8863],{},"nouveaux circuits",[447,8865,8866,8867],{},"Extension du ",[55,8868,8869],{},"tableau de distribution",[447,8871,8872,8873],{},"Modification de l'",[55,8874,8875],{},"installation de comptage",[447,8877,8878,8881],{},[55,8879,8880],{},"Recâblage"," important",[1759,8883,8884],{},[16,8885,8886,8889],{},[55,8887,8888],{},"Attention :"," Les petites modifications comme le remplacement d'une prise ou d'un interrupteur ne comptent PAS comme modification substantielle.",[3625,8891],{},[23,8893,8895],{"id":8894},"ce-qui-est-autorisé-sous-la-partie-8-dérogations-tolérées","Ce qui est autorisé sous la Partie 8 (Dérogations tolérées)",[16,8897,8898],{},"Les points suivants s'écartent du RGIE actuel, mais sont tolérés sous la Partie 8 lors du contrôle :",[367,8900,8902],{"id":8901},"_1-anciens-types-de-câbles","1. Anciens types de câbles",[28,8904,8905,8914],{},[31,8906,8907],{},[34,8908,8909,8911],{},[37,8910,1803],{},[37,8912,8913],{},"Partie 8 tolère",[47,8915,8916,8924,8932],{},[34,8917,8918,8921],{},[52,8919,8920],{},"XVB \u002F VOBst en Preflex",[52,8922,8923],{},"Câbles VOB dans d'anciennes gaines",[34,8925,8926,8929],{},[52,8927,8928],{},"Classe de réaction au feu Cca",[52,8930,8931],{},"Types de câbles plus anciens sans classification CPR",[34,8933,8934,8937],{},[52,8935,8936],{},"Section minimale 2,5 mm² pour les prises",[52,8938,8939],{},"Minimum 1 mm² avec fusible max. 6 A ou disjoncteur max. 10 A (Art. 8.2.1 Nr. 5)",[367,8941,8943],{"id":8942},"_2-différentiels-rcd","2. Différentiels (RCD)",[28,8945,8946,8954],{},[31,8947,8948],{},[34,8949,8950,8952],{},[37,8951,1803],{},[37,8953,8913],{},[47,8955,8956,8964,8972],{},[34,8957,8958,8961],{},[52,8959,8960],{},"Différentiel 30 mA par circuit prises",[52,8962,8963],{},"Pas de 30 mA nécessaire (seulement 300 mA principal)",[34,8965,8966,8969],{},[52,8967,8968],{},"Différentiel 30 mA obligatoire pour salle de bain",[52,8970,8971],{},"Reste obligatoire (non couvert par la dérogation Partie 8, Art. 4.2.4.3 b N° 3 \u002F Art. 7.1.4.3)",[34,8973,8974,8977],{},[52,8975,8976],{},"Max. 8 circuits par RCD",[52,8978,8979],{},"Plus de circuits autorisés",[1759,8981,8982],{},[16,8983,8984,8987,8988,8991],{},[55,8985,8986],{},"Note :"," Même sous la Partie 8, un ",[55,8989,8990],{},"différentiel principal 300 mA"," est recommandé et souvent exigé par le gestionnaire de réseau lors d'une nouvelle installation de compteur.",[367,8993,8995],{"id":8994},"_3-prises-sans-contact-de-terre","3. Prises sans contact de terre",[16,8997,8998],{},"Les anciennes prises (type C, sans broche de terre) sont tolérées sous la Partie 8, à condition que :",[444,9000,9001,9008,9015,9024],{},[447,9002,9003,9004,9007],{},"La prise soit protégée par un ",[55,9005,9006],{},"différentiel à haute ou très haute sensibilité"," (max. 30 mA) (Art. 8.2.1 N° 6 lettre b).",[447,9009,9010,9011,9014],{},"Aucun appareil de ",[55,9012,9013],{},"classe de protection I"," (avec boîtier métallique) ne soit branché.",[447,9016,9017,9018,9020,9021,567],{},"La prise ne soit pas dans la ",[55,9019,1799],{}," ou dans un ",[55,9022,9023],{},"lieu humide",[447,9025,9026],{},"Le circuit soit par ailleurs intact.",[367,9028,9030],{"id":9029},"_4-pas-de-parafoudre-spd","4. Pas de parafoudre (SPD)",[16,9032,9033,9034,567],{},"Le RGIE actuel prescrit un parafoudre (SPD) Type 2 pour les nouvelles installations. Sous la Partie 8, ce n'est ",[55,9035,9036],{},"pas requis",[367,9038,9040],{"id":9039},"_5-ancienne-technique-de-distribution","5. Ancienne technique de distribution",[444,9042,9043,9049,9055],{},[447,9044,1507,9045,9048],{},[55,9046,9047],{},"fusibles"," au lieu de disjoncteurs sont autorisés.",[447,9050,1507,9051,9054],{},[55,9052,9053],{},"fusibles à vis"," (Diazed) sont tolérés.",[447,9056,9057,9058,9061],{},"L'absence d'",[55,9059,9060],{},"étiquetage"," est mentionnée comme défaut, mais n'entraîne pas un échec.",[367,9063,9065],{"id":9064},"_6-pas-de-classification-de-réaction-au-feu-des-câbles","6. Pas de classification de réaction au feu des câbles",[16,9067,9068],{},"Les câbles sans classification CPR (installés avant 2017) sont tolérés, car le règlement CPR ne s'applique qu'à partir de juillet 2017 pour les nouvelles installations.",[3625,9070],{},[23,9072,9074],{"id":9073},"ce-qui-nest-pas-autorisé-même-sous-la-partie-8","Ce qui n'est PAS autorisé (même sous la Partie 8)",[16,9076,9077,9078,9081],{},"Certaines situations ne sont ",[55,9079,9080],{},"jamais tolérées",", quel que soit l'âge de l'installation :",[367,9083,9085],{"id":9084},"absolument-inadmissible","Absolument inadmissible :",[28,9087,9088,9097],{},[31,9089,9090],{},[34,9091,9092,9095],{},[37,9093,9094],{},"Situation",[37,9096,8169],{},[47,9098,9099,9109,9119,9129,9139,9149,9159,9169],{},[34,9100,9101,9106],{},[52,9102,9103],{},[55,9104,9105],{},"Câbles dénudés ou endommagés",[52,9107,9108],{},"Danger immédiat d'électrocution",[34,9110,9111,9116],{},[52,9112,9113],{},[55,9114,9115],{},"Absence totale de mise à la terre",[52,9117,9118],{},"Pas de protection en cas de défaut d'isolement",[34,9120,9121,9126],{},[52,9122,9123],{},[55,9124,9125],{},"Eau en contact avec l'électricité",[52,9127,9128],{},"Danger de mort",[34,9130,9131,9136],{},[52,9132,9133],{},[55,9134,9135],{},"Parties sous tension accessibles",[52,9137,9138],{},"Risque de contact direct",[34,9140,9141,9146],{},[52,9142,9143],{},[55,9144,9145],{},"Câbles ou connexions en surchauffe",[52,9147,9148],{},"Risque d'incendie",[34,9150,9151,9156],{},[52,9152,9153],{},[55,9154,9155],{},"Connexions desserrées dans les boîtes de dérivation",[52,9157,9158],{},"Risque d'arc\u002Fincendie",[34,9160,9161,9166],{},[52,9162,9163],{},[55,9164,9165],{},"Boîtes de dérivation sans couvercle",[52,9167,9168],{},"Protection contre les contacts manquante",[34,9170,9171,9176],{},[52,9172,9173],{},[55,9174,9175],{},"Prise de salle de bain en zone 0 ou 1",[52,9177,9178],{},"Danger de mort, interdit même sous Partie 8",[367,9180,9182],{"id":9181},"exigences-minimales-de-sécurité","Exigences minimales de sécurité :",[16,9184,9185],{},"Même sous la Partie 8, il faut garantir :",[444,9187,9188,9194,9200,9206],{},[447,9189,9190,9193],{},[55,9191,9192],{},"Section suffisante"," pour la charge réelle (pas de câble 0,75 mm² surchargé).",[447,9195,9196,9199],{},[55,9197,9198],{},"Fusibles fonctionnels"," (pas de fusibles « pontés »).",[447,9201,9202,9205],{},[55,9203,9204],{},"Mise à la terre du tableau principal"," (connexion à l'électrode de terre).",[447,9207,9208,9211],{},[55,9209,9210],{},"Accessibilité"," du tableau de distribution.",[3625,9213],{},[23,9215,9217],{"id":9216},"contrôle-périodique","Contrôle périodique",[367,9219,9221],{"id":9220},"tous-les-25-ans-obligatoire","Tous les 25 ans obligatoire",[16,9223,9224,9225,9227],{},"Les installations existantes sous la Partie 8 doivent subir un contrôle périodique tous les ",[55,9226,3113],{}," par un organisme de contrôle agréé.",[367,9229,9231],{"id":9230},"lors-dun-changement-de-propriétaire","Lors d'un changement de propriétaire",[16,9233,9234,9235,9238],{},"Lors de la ",[55,9236,9237],{},"vente d'un bien immobilier",", une attestation de contrôle valide (de moins de 25 ans) est obligatoire. Si elle n'existe pas, un contrôle doit être effectué avant la vente.",[1759,9240,9241],{},[16,9242,9243,9246,9247,9249],{},[55,9244,9245],{},"Délai de 18 mois (Art. 8.4.2.2) :"," Lors de l'achat d'un bien immobilier avec un rapport de contrôle négatif, l'acheteur dispose de ",[55,9248,3127],{}," à compter de la date d'achat pour remédier aux défauts et faire effectuer un recontrôle.",[367,9251,9253],{"id":9252},"que-vérifie-t-on-lors-du-contrôle-périodique","Que vérifie-t-on lors du contrôle périodique ?",[28,9255,9256,9266],{},[31,9257,9258],{},[34,9259,9260,9263],{},[37,9261,9262],{},"Point de contrôle",[37,9264,9265],{},"Évaluation",[47,9267,9268,9276,9284,9292,9300,9308,9316],{},[34,9269,9270,9273],{},[52,9271,9272],{},"Inspection visuelle des câbles et connexions",[52,9274,9275],{},"Dommages, surchauffe",[34,9277,9278,9281],{},[52,9279,9280],{},"Mesure de la résistance de terre",[52,9282,9283],{},"≤ 30 Ω (seuil réglementaire selon Art. 4.2.4.3b ; au-delà, des mesures de protection supplémentaires sont nécessaires)",[34,9285,9286,9289],{},[52,9287,9288],{},"Mesure de la résistance d'isolement",[52,9290,9291],{},"> 0,5 MΩ",[34,9293,9294,9297],{},[52,9295,9296],{},"Test RCD (si présent)",[52,9298,9299],{},"Temps et courant de déclenchement",[34,9301,9302,9305],{},[52,9303,9304],{},"Vérification de la protection contre les courts-circuits",[52,9306,9307],{},"Fusibles \u002F disjoncteurs présents",[34,9309,9310,9313],{},[52,9311,9312],{},"Protection contre les contacts directs",[52,9314,9315],{},"Couvercles, protection IP",[34,9317,9318,9321],{},[52,9319,9320],{},"Documentation",[52,9322,9323],{},"Schéma unifilaire + plan de situation présents ?",[1759,9325,9326],{},[16,9327,9328,8987,9330,3696,9332,9334],{},[55,9329,8986],{},[55,9331,518],{},[55,9333,519],{}," doivent être disponibles — même s'ils doivent être établis rétroactivement.",[3625,9336],{},[23,9338,9340],{"id":9339},"la-règle-de-contamination-lors-dune-rénovation-partielle","La règle de contamination lors d'une rénovation partielle",[16,9342,9343,9344,567],{},"Un aspect particulièrement important pour les anciens bâtiments : la ",[55,9345,2244],{},[367,9347,9349],{"id":9348},"comment-fonctionne-t-elle","Comment fonctionne-t-elle ?",[16,9351,9352,9353,9356],{},"Lorsque vous modifiez ",[55,9354,9355],{},"substantiellement"," une partie de votre installation (par ex. ajout de nouveaux circuits) :",[937,9358,9359,9365,9371],{},[447,9360,1796,9361,9364],{},[55,9362,9363],{},"nouvelle partie"," doit entièrement répondre au RGIE actuel.",[447,9366,1796,9367,9370],{},[55,9368,9369],{},"partie existante"," continue d'être évaluée selon la Partie 8.",[447,9372,9373,9376],{},[55,9374,9375],{},"MAIS :"," Si la nouvelle partie « contamine » la partie existante (par ex. nouveaux câbles dans le même tableau), le contrôleur peut décider que l'ensemble du tableau doit répondre au RGIE actuel.",[367,9378,9380],{"id":9379},"conséquences-pratiques","Conséquences pratiques :",[444,9382,9383,9389,9396],{},[447,9384,9385,9386,567],{},"Planifiez les rénovations de manière à ce que les parties nouvelles et anciennes soient ",[55,9387,9388],{},"clairement séparées",[447,9390,9391,9392,9395],{},"Idéalement, un ",[55,9393,9394],{},"sous-tableau séparé"," pour les nouveaux circuits.",[447,9397,9398],{},"Documentez précisément ce qui est ancien et ce qui est nouveau.",[3625,9400],{},[23,9402,9404],{"id":9403},"recommandation-modernisation-progressive","Recommandation : Modernisation progressive",[16,9406,9407,9408,9411],{},"Même si la Partie 8 tolère des dérogations, une ",[55,9409,9410],{},"modernisation progressive"," est recommandée :",[367,9413,9415],{"id":9414},"priorité-1-critique-pour-la-sécurité","Priorité 1 (Critique pour la sécurité)",[444,9417,9418,9421,9424,9427],{},[447,9419,9420],{},"Installer un différentiel principal 300 mA (s'il est absent)",[447,9422,9423],{},"Remplacer les câbles endommagés",[447,9425,9426],{},"Réparer les connexions desserrées",[447,9428,9429],{},"Vérifier et améliorer la mise à la terre si nécessaire",[367,9431,9433],{"id":9432},"priorité-2-recommandé","Priorité 2 (Recommandé)",[444,9435,9436,9439,9442],{},[447,9437,9438],{},"Différentiels de groupe 30 mA pour salle de bain et cuisine",[447,9440,9441],{},"Remplacer les anciens fusibles par des disjoncteurs",[447,9443,9444],{},"Installer un parafoudre Type 2",[367,9446,9448],{"id":9447},"priorité-3-confort-pérennité","Priorité 3 (Confort + pérennité)",[444,9450,9451,9454,9457],{},[447,9452,9453],{},"Moderniser le tableau (plus de rangées, étiquetage)",[447,9455,9456],{},"Installer des prises avec terre",[447,9458,9459],{},"Préparation pour borne de recharge \u002F installation PV",[367,9461,9463],{"id":9462},"orientation-des-coûts","Orientation des coûts",[28,9465,9466,9476],{},[31,9467,9468],{},[34,9469,9470,9473],{},[37,9471,9472],{},"Mesure",[37,9474,9475],{},"Coût estimé",[47,9477,9478,9486,9494,9502,9510,9518],{},[34,9479,9480,9483],{},[52,9481,9482],{},"Installer différentiel principal 300 mA",[52,9484,9485],{},"150–300 EUR",[34,9487,9488,9491],{},[52,9489,9490],{},"Différentiel de groupe 30 mA (par pièce)",[52,9492,9493],{},"80–150 EUR",[34,9495,9496,9499],{},[52,9497,9498],{},"Parafoudre Type 2",[52,9500,9501],{},"100–250 EUR",[34,9503,9504,9507],{},[52,9505,9506],{},"Set de disjoncteurs (10 pièces)",[52,9508,9509],{},"50–100 EUR",[34,9511,9512,9515],{},[52,9513,9514],{},"Nouveau tableau 4 rangées (complet)",[52,9516,9517],{},"500–1.500 EUR",[34,9519,9520,9523],{},[52,9521,9522],{},"Recâblage complet (maison)",[52,9524,9525],{},"5.000–15.000 EUR",[3625,9527],{},[23,9529,9531],{"id":9530},"résumé","Résumé",[28,9533,9534,9544],{},[31,9535,9536],{},[34,9537,9538,9541],{},[37,9539,9540],{},"Question",[37,9542,9543],{},"Réponse",[47,9545,9546,9554,9562,9570,9578],{},[34,9547,9548,9551],{},[52,9549,9550],{},"Mon ancien bâtiment doit-il répondre au RGIE actuel ?",[52,9552,9553],{},"Pas entièrement, la Partie 8 autorise des dérogations",[34,9555,9556,9559],{},[52,9557,9558],{},"Ai-je besoin d'un différentiel 30 mA ?",[52,9560,9561],{},"Pas obligatoire sous Partie 8, mais fortement recommandé",[34,9563,9564,9567],{},[52,9565,9566],{},"Les anciennes prises sans terre sont-elles autorisées ?",[52,9568,9569],{},"Sous conditions oui (pas de salle de bain, pas d'appareils classe I)",[34,9571,9572,9575],{},[52,9573,9574],{},"À quelle fréquence faut-il contrôler ?",[52,9576,9577],{},"Tous les 25 ans + lors d'un changement de propriétaire",[34,9579,9580,9583],{},[52,9581,9582],{},"Que se passe-t-il en cas de rénovation partielle ?",[52,9584,9585],{},"Nouvelle partie = RGIE actuel, ancienne = Partie 8 (règle de contamination)",[3625,9587],{},[23,9589,2178],{"id":2177},[444,9591,9592,9597,9603,9609],{},[447,9593,9594],{},[262,9595,9596],{"href":856},"Contrôle électrique en Belgique : Que vérifie-t-on ?",[447,9598,9599],{},[262,9600,9602],{"href":9601},"\u002Ffr\u002Fblog\u002Frgie-2026-changements","Que change le RGIE 2026 ?",[447,9604,9605],{},[262,9606,9608],{"href":9607},"\u002Ffr\u002Fblog\u002Fpreflex-vs-pose-libre","Preflex vs. pose libre",[447,9610,9611],{},[262,9612,9613],{"href":463},"Planifier un tableau électrique",[3625,9615],{},[16,9617,9618],{},[258,9619,9620,9621,9623,9624],{},"Même pour les anciens bâtiments, ",[55,9622,42],{}," aide à construire numériquement le schéma unifilaire et le plan de situation. L'auto-contrôle est indicatif ; faites vérifier les documents et les dérogations applicables par un professionnel. ",[262,9625,9626],{"href":1216},"Commencer gratuitement →",{"title":487,"searchDepth":488,"depth":488,"links":9628},[9629,9630,9635,9643,9647,9652,9656,9662,9663],{"id":8794,"depth":488,"text":8795},{"id":8825,"depth":488,"text":8826,"children":9631},[9632,9633,9634],{"id":8836,"depth":497,"text":8837},{"id":8843,"depth":497,"text":8844},{"id":8854,"depth":497,"text":8855},{"id":8894,"depth":488,"text":8895,"children":9636},[9637,9638,9639,9640,9641,9642],{"id":8901,"depth":497,"text":8902},{"id":8942,"depth":497,"text":8943},{"id":8994,"depth":497,"text":8995},{"id":9029,"depth":497,"text":9030},{"id":9039,"depth":497,"text":9040},{"id":9064,"depth":497,"text":9065},{"id":9073,"depth":488,"text":9074,"children":9644},[9645,9646],{"id":9084,"depth":497,"text":9085},{"id":9181,"depth":497,"text":9182},{"id":9216,"depth":488,"text":9217,"children":9648},[9649,9650,9651],{"id":9220,"depth":497,"text":9221},{"id":9230,"depth":497,"text":9231},{"id":9252,"depth":497,"text":9253},{"id":9339,"depth":488,"text":9340,"children":9653},[9654,9655],{"id":9348,"depth":497,"text":9349},{"id":9379,"depth":497,"text":9380},{"id":9403,"depth":488,"text":9404,"children":9657},[9658,9659,9660,9661],{"id":9414,"depth":497,"text":9415},{"id":9432,"depth":497,"text":9433},{"id":9447,"depth":497,"text":9448},{"id":9462,"depth":497,"text":9463},{"id":9530,"depth":488,"text":9531},{"id":2177,"depth":488,"text":2178},"2026-04-14","Ce qui s'applique aux anciennes installations électriques en Belgique. RGIE Partie 8 expliqué : dérogations autorisées, contrôle périodique et conseils pour une modernisation progressive.",{},"\u002Fblog\u002Fold-building-arei-part8.fr",{"title":8776,"description":9665},"ancien-rgie-part-8","blog\u002Fold-building-arei-part8.fr",[9672,521,8788,2245,2241,7449,9673],"ancien bâtiment","périodique","omOCczz1zDQZeVaE62RW1l8-T0oTm2JMKjCL3B7oMdM",{"id":9676,"title":9677,"articleId":9678,"body":9679,"category":906,"date":10892,"description":10893,"extension":507,"lastUpdated":2234,"locale":508,"meta":10894,"navigation":510,"path":10895,"publishDate":10892,"readTime":512,"refreshInterval":913,"seo":10896,"slug":10897,"stem":10898,"tags":10899,"__hash__":10905},"blog\u002Fblog\u002Fdistribution-board-planning.fr.md","Planifier un tableau électrique : Conception et dimensionnement selon le RGIE","distribution-board-planning",{"type":9,"value":9680,"toc":10865},[9681,9684,9687,9689,9693,9697,9708,9712,9723,9812,9816,9819,9887,9894,9896,9900,9903,10046,10057,10059,10063,10070,10074,10080,10084,10152,10156,10163,10165,10169,10173,10180,10184,10238,10240,10244,10250,10261,10265,10276,10278,10282,10285,10289,10370,10374,10480,10484,10587,10591,10690,10695,10697,10701,10795,10797,10801,10808,10819,10826,10828,10830,10851,10853],[12,9682,9677],{"id":9683},"planifier-un-tableau-électrique-conception-et-dimensionnement-selon-le-rgie",[16,9685,9686],{},"Le tableau de distribution (aussi coffret électrique ou tableau divisionnaire) est le cœur de toute installation électrique. C'est là que tous les circuits convergent, c'est là que se trouvent les dispositifs de protection qui protègent votre habitation et votre famille contre les dangers électriques. Une planification réfléchie permet non seulement d'économiser de l'argent, mais aussi d'éviter les problèmes lors du contrôle RGIE.",[3625,9688],{},[23,9690,9692],{"id":9691},"bases-structure-dun-tableau-de-distribution","Bases : Structure d'un tableau de distribution",[367,9694,9696],{"id":9695},"rail-din-rail-oméga","Rail DIN (rail oméga)",[16,9698,9699,9700,9703,9704,9707],{},"Tous les modules du tableau sont encliquetés sur des ",[55,9701,9702],{},"rails DIN"," standardisés (rail oméga 35 mm selon EN 60715). Chaque rail forme une ",[55,9705,9706],{},"rangée"," dans le tableau.",[367,9709,9711],{"id":9710},"modules-unités-de-division","Modules (unités de division)",[16,9713,9714,9715,9718,9719,9722],{},"La largeur d'un module est mesurée en ",[55,9716,9717],{},"modules"," (aussi appelés pas de 9 mm ou TE). Un module correspond à ",[55,9720,9721],{},"18 mm",". Largeurs typiques :",[28,9724,9725,9735],{},[31,9726,9727],{},[34,9728,9729,9732],{},[37,9730,9731],{},"Module",[37,9733,9734],{},"Largeur (modules)",[47,9736,9737,9745,9753,9761,9768,9776,9783,9790,9798,9805],{},[34,9738,9739,9742],{},[52,9740,9741],{},"Disjoncteur 1 pôle",[52,9743,9744],{},"1 module",[34,9746,9747,9750],{},[52,9748,9749],{},"Disjoncteur 2 pôles",[52,9751,9752],{},"2 modules",[34,9754,9755,9758],{},[52,9756,9757],{},"Disjoncteur 3 pôles",[52,9759,9760],{},"3 modules",[34,9762,9763,9766],{},[52,9764,9765],{},"Différentiel 2 pôles (30 mA \u002F 300 mA)",[52,9767,9752],{},[34,9769,9770,9773],{},[52,9771,9772],{},"Différentiel 4 pôles",[52,9774,9775],{},"4 modules",[34,9777,9778,9781],{},[52,9779,9780],{},"Interrupteur principal 2 pôles",[52,9782,9752],{},[34,9784,9785,9788],{},[52,9786,9787],{},"Interrupteur principal 4 pôles",[52,9789,9775],{},[34,9791,9792,9795],{},[52,9793,9794],{},"Parafoudre (SPD)",[52,9796,9797],{},"2–4 modules",[34,9799,9800,9803],{},[52,9801,9802],{},"Transformateur de sonnerie",[52,9804,9752],{},[34,9806,9807,9810],{},[52,9808,9809],{},"Minuterie",[52,9811,9752],{},[367,9813,9815],{"id":9814},"dimensions-des-tableaux","Dimensions des tableaux",[16,9817,9818],{},"Les tableaux sont dimensionnés selon le nombre de rangées et de modules par rangée :",[28,9820,9821,9837],{},[31,9822,9823],{},[34,9824,9825,9828,9831,9834],{},[37,9826,9827],{},"Désignation",[37,9829,9830],{},"Rangées",[37,9832,9833],{},"Modules\u002Frangée",[37,9835,9836],{},"Total modules",[47,9838,9839,9851,9863,9875],{},[34,9840,9841,9844,9846,9849],{},[52,9842,9843],{},"1 rangée",[52,9845,4469],{},[52,9847,9848],{},"12–18",[52,9850,9848],{},[34,9852,9853,9856,9858,9860],{},[52,9854,9855],{},"2 rangées",[52,9857,658],{},[52,9859,9848],{},[52,9861,9862],{},"24–36",[34,9864,9865,9868,9870,9872],{},[52,9866,9867],{},"3 rangées",[52,9869,4495],{},[52,9871,9848],{},[52,9873,9874],{},"36–54",[34,9876,9877,9880,9882,9884],{},[52,9878,9879],{},"4 rangées",[52,9881,4509],{},[52,9883,9848],{},[52,9885,9886],{},"48–72",[1759,9888,9889],{},[16,9890,9891],{},[55,9892,9893],{},"Pour une maison unifamiliale typique, nous recommandons au minimum un tableau 4 rangées avec 18 modules par rangée (72 modules au total).",[3625,9895],{},[23,9897,9899],{"id":9898},"étape-1-compter-les-circuits","Étape 1 : Compter les circuits",[16,9901,9902],{},"Listez tous les circuits nécessaires. Pour une maison unifamiliale moyenne (3 chambres, 150 m²) :",[28,9904,9905,9917],{},[31,9906,9907],{},[34,9908,9909,9912,9915],{},[37,9910,9911],{},"Type",[37,9913,9914],{},"Nombre",[37,9916,5843],{},[47,9918,9919,9930,9941,9951,9961,9970,9978,9986,9995,10004,10014,10023,10033],{},[34,9920,9921,9924,9927],{},[52,9922,9923],{},"Éclairage",[52,9925,9926],{},"3–4 circuits",[52,9928,9929],{},"B10A ou B16A",[34,9931,9932,9935,9938],{},[52,9933,9934],{},"Prises générales",[52,9936,9937],{},"4–6 circuits",[52,9939,9940],{},"B16A",[34,9942,9943,9946,9948],{},[52,9944,9945],{},"Cuisine dédiée (four)",[52,9947,4469],{},[52,9949,9950],{},"B20A ou B32A",[34,9952,9953,9956,9958],{},[52,9954,9955],{},"Cuisine dédiée (taque)",[52,9957,4469],{},[52,9959,9960],{},"B32A (triphasé évent.)",[34,9962,9963,9966,9968],{},[52,9964,9965],{},"Cuisine dédiée (lave-vaisselle)",[52,9967,4469],{},[52,9969,9940],{},[34,9971,9972,9974,9976],{},[52,9973,2326],{},[52,9975,4469],{},[52,9977,9940],{},[34,9979,9980,9982,9984],{},[52,9981,2342],{},[52,9983,4469],{},[52,9985,9940],{},[34,9987,9988,9991,9993],{},[52,9989,9990],{},"Prises salle de bain",[52,9992,4469],{},[52,9994,9940],{},[34,9996,9997,10000,10002],{},[52,9998,9999],{},"Prises extérieures",[52,10001,4469],{},[52,10003,9940],{},[34,10005,10006,10009,10011],{},[52,10007,10008],{},"Chauffe-eau \u002F boiler",[52,10010,4469],{},[52,10012,10013],{},"B16A ou B20A",[34,10015,10016,10019,10021],{},[52,10017,10018],{},"Garage",[52,10020,4469],{},[52,10022,9940],{},[34,10024,10025,10028,10030],{},[52,10026,10027],{},"Borne de recharge (si présente)",[52,10029,4469],{},[52,10031,10032],{},"B32A",[34,10034,10035,10039,10044],{},[52,10036,10037],{},[55,10038,7047],{},[52,10040,10041],{},[55,10042,10043],{},"17–20 circuits",[52,10045],{},[1759,10047,10048],{},[16,10049,10050,10052,10053,10056],{},[55,10051,6240],{}," Maximum ",[55,10054,10055],{},"8 prises simples ou multiples"," par circuit terminal (RGIE Art. 5.3.5.2b). Les circuits d'éclairage peuvent avoir plus de points, mais en pratique on recommande max. 8 luminaires par circuit.",[3625,10058],{},[23,10060,10062],{"id":10061},"étape-2-choisir-les-dispositifs-de-protection","Étape 2 : Choisir les dispositifs de protection",[16,10064,10065,10066,10069],{},"Les dispositifs de protection sont disposés de manière ",[55,10067,10068],{},"hiérarchique"," — de l'alimentation (en haut) vers le bas :",[367,10071,10073],{"id":10072},"hiérarchie-des-protections","Hiérarchie des protections",[2881,10075,10078],{"className":10076,"code":10077,"language":2886},[2884],"Interrupteur principal (40A ou 63A)\n   └── Différentiel principal 300 mA (Type A-S, sélectif)\n        ├── Différentiel groupe 30 mA #1 (Type A)\n        │    ├── Disj. Éclairage RDC (B10A)\n        │    ├── Disj. Éclairage étage (B10A)\n        │    ├── Disj. Prises séjour (B16A)\n        │    └── Disj. Prises couloir (B16A)\n        ├── Différentiel groupe 30 mA #2 (Type A)\n        │    ├── Disj. Prises cuisine (B16A)\n        │    ├── Disj. Four (B20A)\n        │    ├── Disj. Lave-vaisselle (B16A)\n        │    └── Disj. Prises chambres (B16A)\n        └── Différentiel groupe 30 mA #3 (Type A)\n             ├── Disj. Lave-linge (B16A)\n             ├── Disj. Salle de bain (B16A)\n             ├── Disj. Extérieur (B16A)\n             └── Disj. Garage (B16A)\n",[576,10079,10077],{"__ignoreMap":487},[367,10081,10083],{"id":10082},"types-de-différentiels","Types de différentiels",[28,10085,10086,10098],{},[31,10087,10088],{},[34,10089,10090,10092,10095],{},[37,10091,9911],{},[37,10093,10094],{},"Courant de déclenchement",[37,10096,10097],{},"Application",[47,10099,10100,10113,10126,10139],{},[34,10101,10102,10107,10110],{},[52,10103,10104],{},[55,10105,10106],{},"300 mA Type A-S",[52,10108,10109],{},"300 mA, sélectif (temporisé)",[52,10111,10112],{},"Différentiel principal, déclenche uniquement en cas de défaut en aval",[34,10114,10115,10120,10123],{},[52,10116,10117],{},[55,10118,10119],{},"30 mA Type A",[52,10121,10122],{},"30 mA, instantané",[52,10124,10125],{},"Différentiel de groupe, protection des personnes",[34,10127,10128,10133,10136],{},[52,10129,10130],{},[55,10131,10132],{},"30 mA Type B",[52,10134,10135],{},"30 mA, tous courants",[52,10137,10138],{},"Pour borne de recharge \u002F onduleur avec composante CC",[34,10140,10141,10146,10149],{},[52,10142,10143],{},[55,10144,10145],{},"30 mA Type F",[52,10147,10148],{},"30 mA, indépendant de la fréquence",[52,10150,10151],{},"Pour variateurs de fréquence (pompe à chaleur)",[367,10153,10155],{"id":10154},"sélectivité","Sélectivité",[16,10157,10158,10159,10162],{},"Le différentiel principal (300 mA, ",[55,10160,10161],{},"Type S"," = sélectif) est temporisé et ne déclenche que lorsque le différentiel de groupe (30 mA) n'a pas réagi. Ainsi, en cas de défaut, seul le différentiel de groupe concerné se déclenche, pas toute l'installation.",[3625,10164],{},[23,10166,10168],{"id":10167},"étape-3-répartition-en-rangées","Étape 3 : Répartition en rangées",[367,10170,10172],{"id":10171},"règle-rgie-max-8-circuits-terminaux-par-différentiel","Règle RGIE : Max. 8 circuits terminaux par différentiel",[16,10174,10175,10176,10179],{},"Selon le RGIE Art. 4.2.4.3b, un maximum de ",[55,10177,10178],{},"8 circuits terminaux"," peut être raccordé derrière un différentiel (RCD). En pratique, 4–6 circuits par différentiel sont recommandés pour une réserve confortable.",[367,10181,10183],{"id":10182},"répartition-typique-des-rangées","Répartition typique des rangées",[28,10185,10186,10196],{},[31,10187,10188],{},[34,10189,10190,10193],{},[37,10191,10192],{},"Rangée",[37,10194,10195],{},"Contenu",[47,10197,10198,10208,10218,10228],{},[34,10199,10200,10205],{},[52,10201,10202],{},[55,10203,10204],{},"Rangée 1",[52,10206,10207],{},"Interrupteur principal, Différentiel principal (300 mA), Parafoudre, évent. transfo sonnerie",[34,10209,10210,10215],{},[52,10211,10212],{},[55,10213,10214],{},"Rangée 2",[52,10216,10217],{},"Différentiel groupe #1 (30 mA) + disjoncteurs associés (éclairage + prises séjour)",[34,10219,10220,10225],{},[52,10221,10222],{},[55,10223,10224],{},"Rangée 3",[52,10226,10227],{},"Différentiel groupe #2 (30 mA) + disjoncteurs associés (cuisine + chambres)",[34,10229,10230,10235],{},[52,10231,10232],{},[55,10233,10234],{},"Rangée 4",[52,10236,10237],{},"Différentiel groupe #3 (30 mA) + disjoncteurs associés (SDB, extérieur, garage, technique)",[3625,10239],{},[23,10241,10243],{"id":10242},"étape-4-prévoir-des-emplacements-de-réserve","Étape 4 : Prévoir des emplacements de réserve",[16,10245,3298,10246,10249],{},[55,10247,10248],{},"20 % d'emplacements de réserve"," — idéalement 30 %. Cela signifie :",[444,10251,10252,10255],{},[447,10253,10254],{},"Pour 20 disjoncteurs nécessaires → au minimum 4–6 emplacements libres.",[447,10256,10257,10258,567],{},"Les emplacements vides sont fermés par des ",[55,10259,10260],{},"obturateurs",[16,10262,10263],{},[55,10264,8169],{},[444,10266,10267,10270,10273],{},[447,10268,10269],{},"Extensions futures (borne de recharge, climatisation, sauna).",[447,10271,10272],{},"Redistribution si un différentiel a trop de circuits.",[447,10274,10275],{},"Éviter un remplacement coûteux du tableau.",[3625,10277],{},[23,10279,10281],{"id":10280},"exemple-tableau-4-rangées-pour-maison-unifamiliale","Exemple : Tableau 4 rangées pour maison unifamiliale",[16,10283,10284],{},"Voici un exemple complet pour une maison belge typique (3 CH, 150 m², sans PV) :",[367,10286,10288],{"id":10287},"rangée-1-alimentation-protection-18-modules","Rangée 1 — Alimentation & protection (18 modules)",[28,10290,10291,10305],{},[31,10292,10293],{},[34,10294,10295,10298,10300,10303],{},[37,10296,10297],{},"Position",[37,10299,9731],{},[37,10301,10302],{},"Modules",[37,10304,8036],{},[47,10306,10307,10320,10332,10344,10357],{},[34,10308,10309,10312,10315,10317],{},[52,10310,10311],{},"1–2",[52,10313,10314],{},"Interrupteur principal 2P",[52,10316,658],{},[52,10318,10319],{},"40A interrupteur principal",[34,10321,10322,10325,10328,10330],{},[52,10323,10324],{},"3–4",[52,10326,10327],{},"Différentiel principal 2P",[52,10329,658],{},[52,10331,10106],{},[34,10333,10334,10337,10339,10341],{},[52,10335,10336],{},"5–8",[52,10338,9794],{},[52,10340,4509],{},[52,10342,10343],{},"Protection contre les surtensions",[34,10345,10346,10349,10352,10354],{},[52,10347,10348],{},"9–10",[52,10350,10351],{},"Transfo sonnerie",[52,10353,658],{},[52,10355,10356],{},"Sonnerie 8V",[34,10358,10359,10362,10365,10367],{},[52,10360,10361],{},"11–18",[52,10363,10364],{},"Réserve",[52,10366,4561],{},[52,10368,10369],{},"Obturateurs",[367,10371,10373],{"id":10372},"rangée-2-groupe-1-éclairage-séjour-18-modules","Rangée 2 — Groupe 1 : Éclairage + séjour (18 modules)",[28,10375,10376,10388],{},[31,10377,10378],{},[34,10379,10380,10382,10384,10386],{},[37,10381,10297],{},[37,10383,9731],{},[37,10385,10302],{},[37,10387,8036],{},[47,10389,10390,10401,10413,10424,10435,10447,10458,10469],{},[34,10391,10392,10394,10397,10399],{},[52,10393,10311],{},[52,10395,10396],{},"Différentiel groupe 30 mA",[52,10398,658],{},[52,10400,8182],{},[34,10402,10403,10405,10408,10410],{},[52,10404,4495],{},[52,10406,10407],{},"Disj. B10A",[52,10409,4469],{},[52,10411,10412],{},"Éclairage RDC",[34,10414,10415,10417,10419,10421],{},[52,10416,4509],{},[52,10418,10407],{},[52,10420,4469],{},[52,10422,10423],{},"Éclairage étage",[34,10425,10426,10428,10430,10432],{},[52,10427,4522],{},[52,10429,10407],{},[52,10431,4469],{},[52,10433,10434],{},"Éclairage cave\u002Fextérieur",[34,10436,10437,10439,10442,10444],{},[52,10438,4535],{},[52,10440,10441],{},"Disj. B16A",[52,10443,4469],{},[52,10445,10446],{},"Prises séjour",[34,10448,10449,10451,10453,10455],{},[52,10450,4548],{},[52,10452,10441],{},[52,10454,4469],{},[52,10456,10457],{},"Prises salle à manger",[34,10459,10460,10462,10464,10466],{},[52,10461,4561],{},[52,10463,10441],{},[52,10465,4469],{},[52,10467,10468],{},"Prises couloir",[34,10470,10471,10474,10476,10478],{},[52,10472,10473],{},"9–18",[52,10475,10364],{},[52,10477,4588],{},[52,10479,10369],{},[367,10481,10483],{"id":10482},"rangée-3-groupe-2-cuisine-chambres-18-modules","Rangée 3 — Groupe 2 : Cuisine + chambres (18 modules)",[28,10485,10486,10498],{},[31,10487,10488],{},[34,10489,10490,10492,10494,10496],{},[37,10491,10297],{},[37,10493,9731],{},[37,10495,10302],{},[37,10497,8036],{},[47,10499,10500,10510,10521,10533,10544,10555,10566,10577],{},[34,10501,10502,10504,10506,10508],{},[52,10503,10311],{},[52,10505,10396],{},[52,10507,658],{},[52,10509,8182],{},[34,10511,10512,10514,10516,10518],{},[52,10513,4495],{},[52,10515,10441],{},[52,10517,4469],{},[52,10519,10520],{},"Prises cuisine",[34,10522,10523,10525,10528,10530],{},[52,10524,4509],{},[52,10526,10527],{},"Disj. B20A",[52,10529,4469],{},[52,10531,10532],{},"Four (dédié)",[34,10534,10535,10537,10539,10541],{},[52,10536,4522],{},[52,10538,10441],{},[52,10540,4469],{},[52,10542,10543],{},"Lave-vaisselle (dédié)",[34,10545,10546,10548,10550,10552],{},[52,10547,4535],{},[52,10549,10441],{},[52,10551,4469],{},[52,10553,10554],{},"Réfrigérateur (dédié)",[34,10556,10557,10559,10561,10563],{},[52,10558,4548],{},[52,10560,10441],{},[52,10562,4469],{},[52,10564,10565],{},"Prises chambre 1",[34,10567,10568,10570,10572,10574],{},[52,10569,4561],{},[52,10571,10441],{},[52,10573,4469],{},[52,10575,10576],{},"Prises chambres 2+3",[34,10578,10579,10581,10583,10585],{},[52,10580,10473],{},[52,10582,10364],{},[52,10584,4588],{},[52,10586,10369],{},[367,10588,10590],{"id":10589},"rangée-4-groupe-3-sdb-extérieur-technique-18-modules","Rangée 4 — Groupe 3 : SDB, extérieur, technique (18 modules)",[28,10592,10593,10605],{},[31,10594,10595],{},[34,10596,10597,10599,10601,10603],{},[37,10598,10297],{},[37,10600,9731],{},[37,10602,10302],{},[37,10604,8036],{},[47,10606,10607,10617,10627,10638,10649,10660,10670,10680],{},[34,10608,10609,10611,10613,10615],{},[52,10610,10311],{},[52,10612,10396],{},[52,10614,658],{},[52,10616,8182],{},[34,10618,10619,10621,10623,10625],{},[52,10620,4495],{},[52,10622,10441],{},[52,10624,4469],{},[52,10626,9990],{},[34,10628,10629,10631,10633,10635],{},[52,10630,4509],{},[52,10632,10441],{},[52,10634,4469],{},[52,10636,10637],{},"Lave-linge (dédié)",[34,10639,10640,10642,10644,10646],{},[52,10641,4522],{},[52,10643,10441],{},[52,10645,4469],{},[52,10647,10648],{},"Sèche-linge (dédié)",[34,10650,10651,10653,10655,10657],{},[52,10652,4535],{},[52,10654,10527],{},[52,10656,4469],{},[52,10658,10659],{},"Boiler (dédié)",[34,10661,10662,10664,10666,10668],{},[52,10663,4548],{},[52,10665,10441],{},[52,10667,4469],{},[52,10669,9999],{},[34,10671,10672,10674,10676,10678],{},[52,10673,4561],{},[52,10675,10441],{},[52,10677,4469],{},[52,10679,10018],{},[34,10681,10682,10684,10686,10688],{},[52,10683,10473],{},[52,10685,10364],{},[52,10687,4588],{},[52,10689,10369],{},[16,10691,10692],{},[55,10693,10694],{},"Total : 18 disjoncteurs + 4 différentiels + parafoudre + interrupteur principal + transfo sonnerie = 34 modules occupés sur 72 → 53 % de réserve",[3625,10696],{},[23,10698,10700],{"id":10699},"erreurs-typiques-de-planification","Erreurs typiques de planification",[28,10702,10703,10716],{},[31,10704,10705],{},[34,10706,10707,10710,10713],{},[37,10708,10709],{},"Erreur",[37,10711,10712],{},"Conséquence",[37,10714,10715],{},"Solution",[47,10717,10718,10729,10740,10751,10762,10773,10784],{},[34,10719,10720,10723,10726],{},[52,10721,10722],{},"Trop peu de rangées",[52,10724,10725],{},"Pas de place pour les extensions",[52,10727,10728],{},"Min. 4 rangées pour maison",[34,10730,10731,10734,10737],{},[52,10732,10733],{},"Pas de parafoudre",[52,10735,10736],{},"Recommandé selon les règles de l'art (Art. 4.5.1)",[52,10738,10739],{},"Prévoir parafoudre (SPD)",[34,10741,10742,10745,10748],{},[52,10743,10744],{},"Plus de 8 circuits terminaux par différentiel",[52,10746,10747],{},"Non-conformité RGIE (Art. 4.2.4.3b)",[52,10749,10750],{},"Ajouter un différentiel de groupe",[34,10752,10753,10756,10759],{},[52,10754,10755],{},"Étiquetage manquant",[52,10757,10758],{},"Remarque lors du contrôle",[52,10760,10761],{},"Étiqueter chaque disjoncteur (n° circuit + fonction)",[34,10763,10764,10767,10770],{},[52,10765,10766],{},"Pas de différentiel principal 300 mA",[52,10768,10769],{},"Sélectivité absente",[52,10771,10772],{},"Toujours prévoir un différentiel principal",[34,10774,10775,10778,10781],{},[52,10776,10777],{},"Mauvais type de différentiel pour borne de recharge",[52,10779,10780],{},"Déclenchement incorrect",[52,10782,10783],{},"Utiliser Type B ou Type A-EV",[34,10785,10786,10789,10792],{},[52,10787,10788],{},"Pas de réserve",[52,10790,10791],{},"Modification coûteuse",[52,10793,10794],{},"Min. 20 % d'emplacements libres",[3625,10796],{},[23,10798,10800],{"id":10799},"étiquetage-et-documentation","Étiquetage et documentation",[16,10802,10803,10804,10807],{},"Chaque disjoncteur doit être ",[55,10805,10806],{},"étiqueté"," avec :",[444,10809,10810,10813,10816],{},[447,10811,10812],{},"Numéro de circuit (identique au schéma unifilaire et au plan de situation)",[447,10814,10815],{},"Fonction (par ex. « Éclairage RDC », « Prises cuisine »)",[447,10817,10818],{},"Optionnel : pièce ou étage",[16,10820,10821,10822,10825],{},"Collez l'étiquette ",[55,10823,10824],{},"dans le couvercle"," du tableau ou utilisez une bandelette d'identification. La plupart des fabricants de tableaux fournissent des inserts inscriptibles.",[3625,10827],{},[23,10829,2178],{"id":2177},[444,10831,10832,10836,10842,10846],{},[447,10833,10834],{},[262,10835,8702],{"href":451},[447,10837,10838],{},[262,10839,10841],{"href":10840},"\u002Ffr\u002Fblog\u002F30ma-rcd-par-prise","Différentiel 30 mA obligatoire par circuit prises",[447,10843,10844],{},[262,10845,4200],{"href":565},[447,10847,10848],{},[262,10849,10850],{"href":1210},"Installation PV dans le schéma",[3625,10852],{},[16,10854,10855],{},[258,10856,10857,10858,10861,10862],{},"Planifiez votre tableau visuellement avec le ",[55,10859,10860],{},"PlanElec Cabinet Editor"," — glissez les modules sur le rail DIN, vérification RGIE automatique incluse. ",[262,10863,10864],{"href":1216},"Essayer maintenant →",{"title":487,"searchDepth":488,"depth":488,"links":10866},[10867,10872,10873,10878,10882,10883,10889,10890,10891],{"id":9691,"depth":488,"text":9692,"children":10868},[10869,10870,10871],{"id":9695,"depth":497,"text":9696},{"id":9710,"depth":497,"text":9711},{"id":9814,"depth":497,"text":9815},{"id":9898,"depth":488,"text":9899},{"id":10061,"depth":488,"text":10062,"children":10874},[10875,10876,10877],{"id":10072,"depth":497,"text":10073},{"id":10082,"depth":497,"text":10083},{"id":10154,"depth":497,"text":10155},{"id":10167,"depth":488,"text":10168,"children":10879},[10880,10881],{"id":10171,"depth":497,"text":10172},{"id":10182,"depth":497,"text":10183},{"id":10242,"depth":488,"text":10243},{"id":10280,"depth":488,"text":10281,"children":10884},[10885,10886,10887,10888],{"id":10287,"depth":497,"text":10288},{"id":10372,"depth":497,"text":10373},{"id":10482,"depth":497,"text":10483},{"id":10589,"depth":497,"text":10590},{"id":10699,"depth":488,"text":10700},{"id":10799,"depth":488,"text":10800},{"id":2177,"depth":488,"text":2178},"2026-04-07","Guide complet pour la planification d'un tableau de distribution. Rail DIN, dispositifs de protection, répartition en rangées et exemple pour une maison unifamiliale.",{},"\u002Fblog\u002Fdistribution-board-planning.fr",{"title":9677,"description":10893},"planifier-tableau-electrique","blog\u002Fdistribution-board-planning.fr",[1573,10900,10901,10902,5231,521,10903,10904],"distribution","rail DIN","RCD","planification","maison unifamiliale","6sSjbnlxwP5v9g02g-ClpSXriJZIUAaMfMCOEw7Z4PU",{"id":10907,"title":10908,"articleId":10909,"body":10910,"category":906,"date":11737,"description":11738,"extension":507,"lastUpdated":2234,"locale":508,"meta":11739,"navigation":510,"path":11740,"publishDate":11737,"readTime":512,"refreshInterval":913,"seo":11741,"slug":11742,"stem":11743,"tags":11744,"__hash__":11749},"blog\u002Fblog\u002Fdraw-situation-plan.fr.md","Dessiner un plan de situation : Guide étape par étape selon le RGIE","draw-situation-plan",{"type":9,"value":10911,"toc":11718},[10912,10915,10922,10938,10941,10943,10947,10951,10954,10958,10980,10984,10987,11090,11092,11096,11107,11273,11280,11282,11286,11289,11293,11326,11330,11350,11354,11374,11378,11381,11405,11409,11428,11430,11434,11441,11446,11457,11462,11476,11493,11495,11499,11502,11528,11530,11532,11619,11621,11625,11688,11690,11692,11706,11708],[12,10913,10908],{"id":10914},"dessiner-un-plan-de-situation-guide-étape-par-étape-selon-le-rgie",[16,10916,10917,10918,10921],{},"Le plan de situation (aussi appelé schéma de position) montre ",[55,10919,10920],{},"où exactement"," chaque composant électrique se trouve dans votre bâtiment. Avec le schéma unifilaire, c'est l'un des deux documents obligatoires pour toute installation électrique en Belgique — sans lui, le contrôle par l'organisme agréé ne sera pas réussi.",[1759,10923,10924],{},[16,10925,10926,10929,10930,10933,10934,10937],{},[55,10927,10928],{},"En bref :"," Tandis que le schéma unifilaire représente le ",[258,10931,10932],{},"raccordement logique"," (quel interrupteur commande quel luminaire, via quel circuit), le plan de situation montre la ",[258,10935,10936],{},"position physique"," de chaque composant sur le plan d'étage.",[16,10939,10940],{},"Dans ce guide, vous apprendrez comment créer un plan de situation conforme aux normes, étape par étape.",[3625,10942],{},[23,10944,10946],{"id":10945},"étape-1-préparer-le-plan-détage","Étape 1 : Préparer le plan d'étage",[367,10948,10950],{"id":10949},"dimensions-et-échelle","Dimensions et échelle",[16,10952,10953],{},"Le plan d'étage constitue la base de votre plan de situation. Vous pouvez le reprendre d'un plan de construction ou le dessiner vous-même.",[16,10955,10956],{},[55,10957,6146],{},[444,10959,10960,10967,10973],{},[447,10961,10962,10963,10966],{},"Utilisez une ",[55,10964,10965],{},"échelle uniforme"," (courante : 1:50 ou 1:100).",[447,10968,10969,10970,567],{},"Dessinez tous les ",[55,10971,10972],{},"murs, portes et fenêtres",[447,10974,10975,10976,10979],{},"Marquez le ",[55,10977,10978],{},"sens d'ouverture"," des portes (quart de cercle) — cela influence la position des interrupteurs.",[367,10981,10983],{"id":10982},"étiqueter-les-pièces","Étiqueter les pièces",[16,10985,10986],{},"Identifiez chaque pièce avec sa désignation et idéalement sa surface :",[28,10988,10989,11002],{},[31,10990,10991],{},[34,10992,10993,10996,10999],{},[37,10994,10995],{},"Abréviation",[37,10997,10998],{},"Pièce",[37,11000,11001],{},"Surface typique",[47,11003,11004,11015,11026,11037,11048,11059,11069,11080],{},[34,11005,11006,11009,11012],{},[52,11007,11008],{},"SÉJ",[52,11010,11011],{},"Séjour",[52,11013,11014],{},"25–40 m²",[34,11016,11017,11020,11023],{},[52,11018,11019],{},"CUI",[52,11021,11022],{},"Cuisine",[52,11024,11025],{},"10–20 m²",[34,11027,11028,11031,11034],{},[52,11029,11030],{},"CH",[52,11032,11033],{},"Chambre",[52,11035,11036],{},"12–18 m²",[34,11038,11039,11042,11045],{},[52,11040,11041],{},"SDB",[52,11043,11044],{},"Salle de bain",[52,11046,11047],{},"5–10 m²",[34,11049,11050,11053,11056],{},[52,11051,11052],{},"COU",[52,11054,11055],{},"Couloir",[52,11057,11058],{},"5–15 m²",[34,11060,11061,11064,11066],{},[52,11062,11063],{},"GAR",[52,11065,10018],{},[52,11067,11068],{},"15–30 m²",[34,11070,11071,11074,11077],{},[52,11072,11073],{},"CAV",[52,11075,11076],{},"Cave",[52,11078,11079],{},"variable",[34,11081,11082,11085,11088],{},[52,11083,11084],{},"EXT",[52,11086,11087],{},"Extérieur",[52,11089,11079],{},[3625,11091],{},[23,11093,11095],{"id":11094},"étape-2-utiliser-les-symboles-rgie","Étape 2 : Utiliser les symboles RGIE",[16,11097,11098,11099,11102,11103,11106],{},"Le RGIE fournit dans le ",[55,11100,11101],{},"Tableau 2.23"," une liste (non exhaustive) des symboles à utiliser. Ceux-ci sont basés sur la norme ",[55,11104,11105],{},"IEC 60617",". Si aucun symbole n'est repris dans le tableau pour un composant, tout autre symbole clairement identifiable peut être utilisé, pour autant qu'il soit défini dans la légende. Voici les 10 symboles les plus importants pour le plan de situation :",[28,11108,11109,11123],{},[31,11110,11111],{},[34,11112,11113,11115,11118,11120],{},[37,11114,4453],{},[37,11116,11117],{},"Symbole",[37,11119,3640],{},[37,11121,11122],{},"Utilisation",[47,11124,11125,11140,11154,11169,11184,11199,11214,11229,11243,11258],{},[34,11126,11127,11129,11132,11137],{},[52,11128,4469],{},[52,11130,11131],{},"⏚ Demi-cercle",[52,11133,11134],{},[55,11135,11136],{},"Prise simple",[52,11138,11139],{},"Marquer position murale",[34,11141,11142,11144,11147,11152],{},[52,11143,658],{},[52,11145,11146],{},"⏚⏚ Double demi-cercle",[52,11148,11149],{},[55,11150,11151],{},"Prise double",[52,11153,11139],{},[34,11155,11156,11158,11161,11166],{},[52,11157,4495],{},[52,11159,11160],{},"○ avec croix",[52,11162,11163],{},[55,11164,11165],{},"Plafonnier",[52,11167,11168],{},"Centre de la pièce\u002Fposition",[34,11170,11171,11173,11176,11181],{},[52,11172,4509],{},[52,11174,11175],{},"─○ avec trait",[52,11177,11178],{},[55,11179,11180],{},"Applique murale",[52,11182,11183],{},"Sur le mur",[34,11185,11186,11188,11191,11196],{},[52,11187,4522],{},[52,11189,11190],{},"Symbole interrupteur",[52,11192,11193],{},[55,11194,11195],{},"Interrupteur unipolaire",[52,11197,11198],{},"À côté de la porte (côté ouverture)",[34,11200,11201,11203,11206,11211],{},[52,11202,4535],{},[52,11204,11205],{},"Symbole interrupteur 2 flèches",[52,11207,11208],{},[55,11209,11210],{},"Interrupteur sériel",[52,11212,11213],{},"Commande 2 luminaires",[34,11215,11216,11218,11221,11226],{},[52,11217,4548],{},[52,11219,11220],{},"Symbole interrupteur avec ligne",[52,11222,11223],{},[55,11224,11225],{},"Interrupteur va-et-vient",[52,11227,11228],{},"Deux points, un luminaire",[34,11230,11231,11233,11236,11240],{},[52,11232,4561],{},[52,11234,11235],{},"Rectangle avec éclair",[52,11237,11238],{},[55,11239,4960],{},[52,11241,11242],{},"Généralement couloir\u002Flocal technique",[34,11244,11245,11247,11250,11255],{},[52,11246,4574],{},[52,11248,11249],{},"⏚ avec PE",[52,11251,11252],{},[55,11253,11254],{},"Prise de terre",[52,11256,11257],{},"Point de mise à la terre",[34,11259,11260,11262,11265,11270],{},[52,11261,4588],{},[52,11263,11264],{},"Cercle avec R",[52,11266,11267],{},[55,11268,11269],{},"Détecteur de fumée",[52,11271,11272],{},"Chaque chambre, couloir, cage d'escalier",[1759,11274,11275],{},[16,11276,11277,11279],{},[55,11278,6240],{}," Utilisez les symboles RGIE du Tableau 2.23 pour les composants courants. Si des symboles différents sont nécessaires, ils doivent être clairement identifiables et expliqués dans la légende — les symboles non définis ou non expliqués seront refusés lors du contrôle.",[3625,11281],{},[23,11283,11285],{"id":11284},"étape-3-dessiner-les-composants","Étape 3 : Dessiner les composants",[16,11287,11288],{},"Placez maintenant les symboles sur le plan d'étage. Les règles suivantes aident au positionnement correct :",[367,11290,11292],{"id":11291},"prises-de-courant","Prises de courant",[444,11294,11295,11302,11308,11314,11320],{},[447,11296,11297,11298,11301],{},"Dessiner ",[55,11299,11300],{},"sur le mur",", à la position réelle.",[447,11303,11304,11307],{},[55,11305,11306],{},"Cuisine :"," plan de travail minimum 4 prises, dont 2 au-dessus du plan de travail. Prises dédiées pour four, lave-vaisselle, réfrigérateur.",[447,11309,11310,11313],{},[55,11311,11312],{},"Pièces de vie :"," Min. 1 prise par tranche de 4 m² entamée (recommandation pratique des associations d'installateurs — le RGIE ne prescrit pas de nombre minimum de prises par surface).",[447,11315,11316,11319],{},[55,11317,11318],{},"Salle de bain :"," Prises basse tension à partir de la zone 2 (uniquement pour les baignoires ; la prise doit être protégée par un dispositif différentiel à très haute sensibilité ≤ 10 mA, ou individuellement par un transformateur de séparation d'une puissance maximale de 100 W) ou hors zones. Pour les douches, la zone 2 n'existe pas (art. 7.1.3.2 n° 3b, art. 7.1.5.2d).",[447,11321,11322,11325],{},[55,11323,11324],{},"Extérieur :"," Si une prise extérieure est installée, elle doit être protégée contre les intempéries (IP44) et sécurisée par son propre différentiel 30mA.",[367,11327,11329],{"id":11328},"interrupteurs","Interrupteurs",[444,11331,11332,11338,11344],{},[447,11333,11334,11337],{},[55,11335,11336],{},"À côté de la porte"," du côté de l'ouverture, à environ 105 cm de hauteur (recommandation pratique — le RGIE ne prescrit pas de hauteur spécifique pour les interrupteurs, mais exige qu'ils soient « facilement accessibles »).",[447,11339,11340,11343],{},[55,11341,11342],{},"Interrupteurs va-et-vient"," pour les pièces à plusieurs entrées ou en début\u002Ffin d'escalier.",[447,11345,11346,11347,567],{},"Reliez les interrupteurs et les luminaires associés par une ",[55,11348,11349],{},"ligne pointillée",[367,11351,11353],{"id":11352},"points-lumineux","Points lumineux",[444,11355,11356,11362,11368],{},[447,11357,11358,11361],{},[55,11359,11360],{},"Plafonniers"," au centre de la pièce ou à la position prévue.",[447,11363,11364,11367],{},[55,11365,11366],{},"Appliques murales"," à la position sur le mur.",[447,11369,11370,11371,567],{},"Chaque pièce nécessite au minimum ",[55,11372,11373],{},"un point lumineux",[367,11375,11377],{"id":11376},"détecteurs-de-fumée","Détecteurs de fumée",[16,11379,11380],{},"Obligatoires selon la législation belge sur la sécurité incendie (varie selon la région) :",[444,11382,11383,11390,11396,11402],{},[447,11384,11385,11386,11389],{},"En ",[55,11387,11388],{},"Flandre :"," Obligatoire dans les voies d'évacuation (couloirs, cages d'escalier) ; dans les chambres recommandé, mais pas obligatoire.",[447,11391,11385,11392,11395],{},[55,11393,11394],{},"Wallonie et Bruxelles"," : des réglementations propres s'appliquent.",[447,11397,11398,11401],{},[55,11399,11400],{},"Couloirs et cages d'escalier"," — au minimum un détecteur de fumée par étage.",[447,11403,11404],{},"Dans la cuisine optionnel (détecteur de chaleur préféré pour éviter les fausses alarmes).",[367,11406,11408],{"id":11407},"consommateurs-spéciaux","Consommateurs spéciaux",[444,11410,11411,11416,11422],{},[447,11412,11413,11415],{},[55,11414,2383],{}," (véhicule électrique) : garage ou mur extérieur, circuit dédié.",[447,11417,11418,11421],{},[55,11419,11420],{},"Chauffe-eau\u002FBoiler :"," Circuit dédié, dessiner la position.",[447,11423,11424,11427],{},[55,11425,11426],{},"Pompe à chaleur\u002FClimatisation :"," Marquer unité extérieure + unité intérieure.",[3625,11429],{},[23,11431,11433],{"id":11432},"étape-4-attribuer-les-numéros-de-circuits","Étape 4 : Attribuer les numéros de circuits",[16,11435,11436,11437,11440],{},"Chaque composant du plan de situation reçoit le ",[55,11438,11439],{},"même numéro de circuit"," que dans le schéma unifilaire. C'est essentiel pour l'attribution lors du contrôle.",[16,11442,11443],{},[55,11444,11445],{},"Comment ça marche :",[937,11447,11448,11451,11454],{},[447,11449,11450],{},"Le RGIE identifie les circuits élémentaires par une lettre majuscule (A, B, C, ...) et les éléments individuels (point lumineux, prise) par un numéro d'ordre — par ex. « A1, A2, ... ».",[447,11452,11453],{},"Inscrivez cet identifiant à côté de chaque composant sur le plan de situation.",[447,11455,11456],{},"Une numérotation simplifiée (par ex. « C1 » ou « 1 ») est courante en pratique, pour autant que le schéma unifilaire et le plan de situation restent cohérents.",[16,11458,11459],{},[55,11460,11461],{},"Exemple :",[444,11463,11464,11467,11470,11473],{},[447,11465,11466],{},"Circuit 1 : Éclairage rez-de-chaussée → Tous les luminaires du RDC reçoivent « 1 ».",[447,11468,11469],{},"Circuit 2 : Prises séjour → Toutes les prises du séjour reçoivent « 2 ».",[447,11471,11472],{},"Circuit 3 : Prises cuisine → Toutes les prises de cuisine reçoivent « 3 ».",[447,11474,11475],{},"Circuit 4 : Dédié four → Une prise avec « 4 ».",[1759,11477,11478,11487],{},[16,11479,11480,11482,11483,11486],{},[55,11481,6146],{}," Les numéros doivent correspondre ",[55,11484,11485],{},"exactement"," entre le schéma unifilaire et le plan de situation. Les incohérences sont l'une des causes les plus fréquentes de remarques lors du contrôle.",[16,11488,11489,11492],{},[55,11490,11491],{},"Obligation de documentation :"," Art. 9.1.2 n° 1 (schéma unifilaire) et art. 9.1.2 n° 2 (plan de situation).",[3625,11494],{},[23,11496,11498],{"id":11497},"étape-5-légende-et-étiquetage","Étape 5 : Légende et étiquetage",[16,11500,11501],{},"Complétez votre plan avec :",[444,11503,11504,11510,11516,11522],{},[447,11505,11506,11509],{},[55,11507,11508],{},"Légende"," avec tous les symboles utilisés et leur signification.",[447,11511,11512,11515],{},[55,11513,11514],{},"Cartouche"," avec : nom du propriétaire, adresse, date, auteur du plan, échelle.",[447,11517,11518,11521],{},[55,11519,11520],{},"Flèche nord"," (optionnel, mais utile).",[447,11523,11524,11527],{},[55,11525,11526],{},"Indication d'étage"," pour les bâtiments à plusieurs niveaux (un plan par étage).",[3625,11529],{},[23,11531,791],{"id":790},[28,11533,11534,11544],{},[31,11535,11536],{},[34,11537,11538,11540,11542],{},[37,11539,10709],{},[37,11541,10712],{},[37,11543,10715],{},[47,11545,11546,11557,11568,11578,11588,11599,11609],{},[34,11547,11548,11551,11554],{},[52,11549,11550],{},"Détecteurs de fumée manquants",[52,11552,11553],{},"Contrôle non réussi",[52,11555,11556],{},"Min. 1 par étage dans les voies d'évacuation (varie selon la région)",[34,11558,11559,11562,11565],{},[52,11560,11561],{},"Prise extérieure non conforme",[52,11563,11564],{},"Remarque, si installée mais non conforme",[52,11566,11567],{},"Si installée : IP44, différentiel 30mA dédié. L'absence de prise extérieure n'est pas un motif de refus",[34,11569,11570,11573,11575],{},[52,11571,11572],{},"Étiquetage \u002F numéros de circuits manquants",[52,11574,7948],{},[52,11576,11577],{},"Numéroter chaque composant",[34,11579,11580,11583,11585],{},[52,11581,11582],{},"Symboles non définis\u002Fnon expliqués",[52,11584,7948],{},[52,11586,11587],{},"Utiliser les symboles RGIE (Tableau 2.23) ; choisir des symboles différents de façon claire et les expliquer dans la légende",[34,11589,11590,11593,11596],{},[52,11591,11592],{},"Interrupteur du mauvais côté de la porte",[52,11594,11595],{},"Non pratique (pas d'infraction RGIE)",[52,11597,11598],{},"Vérifier le sens d'ouverture",[34,11600,11601,11604,11606],{},[52,11602,11603],{},"Prise salle de bain en zone 0 ou 1",[52,11605,11553],{},[52,11607,11608],{},"Prises à partir de la zone 2 (baignoire uniquement) ou hors zones (douche) (art. 7.1.5.2c\u002Fd)",[34,11610,11611,11614,11616],{},[52,11612,11613],{},"Pas de légende",[52,11615,7948],{},[52,11617,11618],{},"Joindre un tableau de symboles",[3625,11620],{},[23,11622,11624],{"id":11623},"checklist-avant-soumission","Checklist avant soumission",[444,11626,11628,11634,11640,11646,11652,11658,11664,11670,11676,11682],{"className":11627},[2111],[447,11629,11631,11633],{"className":11630},[2115],[2117,11632],{"disabled":510,"type":2119}," Toutes les pièces étiquetées",[447,11635,11637,11639],{"className":11636},[2115],[2117,11638],{"disabled":510,"type":2119}," Toutes les prises, interrupteurs, luminaires dessinés",[447,11641,11643,11645],{"className":11642},[2115],[2117,11644],{"disabled":510,"type":2119}," Détecteurs de fumée dans les voies d'évacuation (min. 1 par étage, varie selon la région)",[447,11647,11649,11651],{"className":11648},[2115],[2117,11650],{"disabled":510,"type":2119}," Prises extérieures, si installées, conformes (IP44, différentiel 30mA dédié)",[447,11653,11655,11657],{"className":11654},[2115],[2117,11656],{"disabled":510,"type":2119}," Numéros de circuits sur chaque composant",[447,11659,11661,11663],{"className":11660},[2115],[2117,11662],{"disabled":510,"type":2119}," Les numéros correspondent au schéma unifilaire",[447,11665,11667,11669],{"className":11666},[2115],[2117,11668],{"disabled":510,"type":2119}," Symboles RGIE utilisés (Tableau 2.23)",[447,11671,11673,11675],{"className":11672},[2115],[2117,11674],{"disabled":510,"type":2119}," Légende présente",[447,11677,11679,11681],{"className":11678},[2115],[2117,11680],{"disabled":510,"type":2119}," Cartouche avec nom, adresse, date",[447,11683,11685,11687],{"className":11684},[2115],[2117,11686],{"disabled":510,"type":2119}," Un plan par étage",[3625,11689],{},[23,11691,2178],{"id":2177},[444,11693,11694,11698,11702],{},[447,11695,11696],{},[262,11697,8702],{"href":451},[447,11699,11700],{},[262,11701,8716],{"href":856},[447,11703,11704],{},[262,11705,8707],{"href":463},[3625,11707],{},[16,11709,11710],{},[258,11711,477,11712,11714,11715],{},[55,11713,42],{},", créez votre plan de situation directement à partir du plan d'étage — dessinez les pièces, placez les appareils par glisser-déposer, les symboles RGIE sont utilisés automatiquement. ",[262,11716,11717],{"href":1216},"Essayer gratuitement →",{"title":487,"searchDepth":488,"depth":488,"links":11719},[11720,11724,11725,11732,11733,11734,11735,11736],{"id":10945,"depth":488,"text":10946,"children":11721},[11722,11723],{"id":10949,"depth":497,"text":10950},{"id":10982,"depth":497,"text":10983},{"id":11094,"depth":488,"text":11095},{"id":11284,"depth":488,"text":11285,"children":11726},[11727,11728,11729,11730,11731],{"id":11291,"depth":497,"text":11292},{"id":11328,"depth":497,"text":11329},{"id":11352,"depth":497,"text":11353},{"id":11376,"depth":497,"text":11377},{"id":11407,"depth":497,"text":11408},{"id":11432,"depth":488,"text":11433},{"id":11497,"depth":488,"text":11498},{"id":790,"depth":488,"text":791},{"id":11623,"depth":488,"text":11624},{"id":2177,"depth":488,"text":2178},"2026-03-30","Guide complet pour créer un plan de situation conforme au RGIE. De la préparation du plan d'étage aux symboles RGIE jusqu'au dessin finalisé.",{},"\u002Fblog\u002Fdraw-situation-plan.fr",{"title":10908,"description":11738},"dessiner-plan-situation-guide","blog\u002Fdraw-situation-plan.fr",[519,521,11745,906,11746,11747,11748],"symboles","dessin","plan électrique","plan d'étage","ZMY6g0Zxqhbm9-3KnL6xRq_j9Q3oxLix4YrVJyB0GTw",{"id":11751,"title":11752,"articleId":11753,"body":11754,"category":2574,"date":12029,"description":12030,"extension":507,"lastUpdated":12029,"locale":508,"meta":12031,"navigation":510,"path":12032,"publishDate":12029,"readTime":2579,"refreshInterval":913,"seo":12033,"slug":12034,"stem":12035,"tags":12036,"__hash__":12042},"blog\u002Fblog\u002Fpreflex-vs-open-wiring.fr.md","Preflex vs. pose libre : Quelle méthode de câblage pour votre projet ?","preflex-vs-open-wiring",{"type":9,"value":11755,"toc":12020},[11756,11760,11766,11770,11773,11777,11887,11891,11910,11914,11934,11938,11957,11964,11968,11987,11989,11991,12008,12010],[12,11757,11759],{"id":11758},"preflex-vs-pose-libre-quelle-méthode-convient-à-votre-projet","Preflex vs. pose libre : Quelle méthode convient à votre projet ?",[16,11761,11762,11765],{},[55,11763,11764],{},"Réponse courte :"," Le Preflex est une gaine préfabriquée avec des câbles déjà tirés — idéal pour la construction neuve, où il est directement coulé dans le béton. La pose libre (par ex. XVB en apparent ou en goulotte) convient mieux aux rénovations, où les gaines sont difficiles à installer après coup.",[23,11767,11769],{"id":11768},"quest-ce-que-le-preflex","Qu'est-ce que le Preflex ?",[16,11771,11772],{},"Le Preflex est un tube annelé flexible (gaine d'attente) dans lequel les câbles appropriés sont déjà tirés en usine. En Belgique, cette méthode est extrêmement répandue dans la construction neuve : les gaines sont posées pendant la phase de gros œuvre sur la dalle en béton ou dans la chape, puis coulées. Les câbles sont ainsi entièrement protégés et remplaçables ultérieurement si nécessaire.",[23,11774,11776],{"id":11775},"comparaison-preflex-safe-vs-preflex-normal-vs-pose-libre","Comparaison : Preflex Safe vs. Preflex normal vs. pose libre",[28,11778,11779,11794],{},[31,11780,11781],{},[34,11782,11783,11785,11788,11791],{},[37,11784,39],{},[37,11786,11787],{},"Preflex Safe",[37,11789,11790],{},"Preflex normal",[37,11792,11793],{},"Pose libre (XVB)",[47,11795,11796,11812,11828,11843,11857,11871],{},[34,11797,11798,11803,11806,11809],{},[52,11799,11800],{},[55,11801,11802],{},"Gaine",[52,11804,11805],{},"Sans halogène (LSOH)",[52,11807,11808],{},"PVC standard",[52,11810,11811],{},"Pas de gaine, câble direct",[34,11813,11814,11819,11822,11825],{},[52,11815,11816],{},[55,11817,11818],{},"Classe CPR",[52,11820,11821],{},"Cca-s1,d1,a1 (câble dans conduit)",[52,11823,11824],{},"Eca (câble dans conduit ; la classe CPR se réfère au câble, pas au conduit lui-même)",[52,11826,11827],{},"XVB avec marquage CPR Cca-s1,d2,a1 (exigé dans certains modes de pose pour les nouvelles installations ; les stocks anciens peuvent encore être classés Eca)",[34,11829,11830,11834,11837,11840],{},[52,11831,11832],{},[55,11833,10097],{},[52,11835,11836],{},"Neuf, bâtiments publics",[52,11838,11839],{},"Neuf résidentiel",[52,11841,11842],{},"Rénovation, apparent",[34,11844,11845,11850,11852,11854],{},[52,11846,11847],{},[55,11848,11849],{},"Remplacement câble",[52,11851,150],{},[52,11853,150],{},[52,11855,11856],{},"Non (installation fixe)",[34,11858,11859,11863,11866,11868],{},[52,11860,11861],{},[55,11862,2020],{},[52,11864,11865],{},"Le plus élevé",[52,11867,4374],{},[52,11869,11870],{},"Le plus bas",[34,11872,11873,11878,11881,11884],{},[52,11874,11875],{},[55,11876,11877],{},"Conformité RGIE",[52,11879,11880],{},"Toutes applications",[52,11882,11883],{},"Résidentiel autorisé",[52,11885,11886],{},"Toutes applications (si type de câble correct)",[23,11888,11890],{"id":11889},"avantages-du-preflex","Avantages du Preflex",[444,11892,11893,11899,11905],{},[447,11894,11895,11898],{},[55,11896,11897],{},"Installation soignée :"," Pas de câbles visibles, tout est encastré ou coulé.",[447,11900,11901,11904],{},[55,11902,11903],{},"Pérennité :"," Les câbles peuvent être remplacés ou ajoutés ultérieurement sans casser les murs.",[447,11906,11907,11909],{},[55,11908,5140],{}," La gaine protège contre les dommages mécaniques.",[23,11911,11913],{"id":11912},"inconvénients-du-preflex","Inconvénients du Preflex",[444,11915,11916,11922,11928],{},[447,11917,11918,11921],{},[55,11919,11920],{},"Plus cher"," que la pose directe de câbles (matériel + main-d'œuvre).",[447,11923,11924,11927],{},[55,11925,11926],{},"Uniquement en construction neuve\u002Frénovation lourde"," — difficilement installable lors d'une simple rénovation.",[447,11929,11930,11933],{},[55,11931,11932],{},"Rayons de courbure"," à respecter : des courbes trop serrées compliquent le retirage ultérieur.",[23,11935,11937],{"id":11936},"que-dit-le-rgie","Que dit le RGIE ?",[16,11939,11940,11941,11944,11945,11948,11949,11952,11953,11956],{},"Le RGIE ne prescrit pas de méthode d'installation particulière — les deux sont autorisées. Ce qui compte, c'est la ",[55,11942,11943],{},"classe de réaction au feu"," (règlement CPR) : les câbles posés individuellement doivent avoir au minimum ",[55,11946,11947],{},"Eca"," (art. 5.2.7.2). En ",[55,11950,11951],{},"faisceaux, cloisons creuses et cavités constructives",", la classe minimale ",[55,11954,11955],{},"Cca"," est exigée (art. 5.2.7.3, art. 4.3.3.5b). Attention : les murs à ossature bois (fréquents en rénovation) comptent comme cavité constructive !",[16,11958,11959,11960,11963],{},"Le conduit ne doit pas être rempli à plus de ",[55,11961,11962],{},"40 %"," par des câbles (règle d'installation générale selon les règles de l'art), afin de permettre le retirage ultérieur.",[23,11965,11967],{"id":11966},"quelle-méthode-choisir","Quelle méthode choisir ?",[444,11969,11970,11975,11981],{},[447,11971,11972,11974],{},[55,11973,4583],{}," → Preflex (Safe pour la meilleure protection incendie)",[447,11976,11977,11980],{},[55,11978,11979],{},"Rénovation"," → Câble XVB en goulotte ou en apparent",[447,11982,11983,11986],{},[55,11984,11985],{},"Rénovation partielle"," → Combinaison possible (nouveaux circuits en Preflex, existants conservés)",[3625,11988],{},[23,11990,2178],{"id":2177},[444,11992,11993,11997,12003],{},[447,11994,11995],{},[262,11996,9602],{"href":9601},[447,11998,11999],{},[262,12000,12002],{"href":12001},"\u002Ffr\u002Fblog\u002Fsalle-de-bain-cables-rgie-zones","Électricité salle de bain : Zones et types de câbles",[447,12004,12005],{},[262,12006,12007],{"href":2185},"Ancien bâtiment et RGIE Partie 8",[3625,12009],{},[16,12011,12012],{},[258,12013,12014,12015,12017,12018],{},"Planifiez votre installation électrique avec ",[55,12016,42],{}," — en construction neuve avec Preflex ou en rénovation avec pose libre — puis exportez le schéma unifilaire et le plan de situation. L'auto-contrôle reste indicatif. ",[262,12019,9626],{"href":1216},{"title":487,"searchDepth":488,"depth":488,"links":12021},[12022,12023,12024,12025,12026,12027,12028],{"id":11768,"depth":488,"text":11769},{"id":11775,"depth":488,"text":11776},{"id":11889,"depth":488,"text":11890},{"id":11912,"depth":488,"text":11913},{"id":11936,"depth":488,"text":11937},{"id":11966,"depth":488,"text":11967},{"id":2177,"depth":488,"text":2178},"2026-03-27","Comparaison des gaines Preflex et de la pose libre de câbles en Belgique. Avantages, inconvénients et classes de réaction au feu RGIE.",{},"\u002Fblog\u002Fpreflex-vs-open-wiring.fr",{"title":11752,"description":12030},"preflex-vs-pose-libre","blog\u002Fpreflex-vs-open-wiring.fr",[12037,12038,12039,2241,521,12040,12041],"preflex","câblage","construction neuve","sécurité incendie","XVB","48j9FIfLvdN3Kks8yUI2zJD2hC2yKxhXAJmYWRrJ4js",{"id":12044,"title":12045,"articleId":12046,"body":12047,"category":2574,"date":12327,"description":12328,"extension":507,"lastUpdated":2234,"locale":508,"meta":12329,"navigation":510,"path":12330,"publishDate":12327,"readTime":7442,"refreshInterval":913,"seo":12331,"slug":12332,"stem":12333,"tags":12334,"__hash__":12339},"blog\u002Fblog\u002Frcd-type-a-vs-b.fr.md","Différentiel Type A vs. Type B : Quand ai-je besoin de quel type ?","rcd-type-a-vs-b",{"type":9,"value":12048,"toc":12318},[12049,12052,12058,12062,12161,12165,12172,12192,12196,12199,12219,12223,12267,12271,12274,12294,12297,12301,12308,12310],[12,12050,12045],{"id":12051},"différentiel-type-a-vs-type-b-quand-ai-je-besoin-de-quel-type",[16,12053,12054,12057],{},[55,12055,12056],{},"Le RGIE prescrit au minimum un différentiel (DDR) de Type A."," Le Type B est requis lorsque des courants de défaut continus peuvent apparaître — typiquement avec des bornes de recharge sans détecteur de courant de défaut DC intégré ou des pompes à chaleur avec variateur de fréquence. Le choix du bon type de DDR est déterminant pour la sécurité et la conformité au contrôle.",[23,12059,12061],{"id":12060},"aperçu-de-tous-les-types-de-ddr","Aperçu de tous les types de DDR",[28,12063,12064,12079],{},[31,12065,12066],{},[34,12067,12068,12070,12073,12076],{},[37,12069,9911],{},[37,12071,12072],{},"Détecte",[37,12074,12075],{},"Domaine d'application",[37,12077,12078],{},"Prix (env.)",[47,12080,12081,12097,12113,12129,12145],{},[34,12082,12083,12088,12091,12094],{},[52,12084,12085],{},[55,12086,12087],{},"AC",[52,12089,12090],{},"Uniquement les courants de défaut alternatifs purs",[52,12092,12093],{},"Obsolète, plus autorisé pour les nouvelles installations",[52,12095,12096],{},"~25–40 €",[34,12098,12099,12104,12107,12110],{},[52,12100,12101],{},[55,12102,12103],{},"A",[52,12105,12106],{},"Alternatifs + courants de défaut continus pulsés",[52,12108,12109],{},"Standard pour usage domestique",[52,12111,12112],{},"~40–60 €",[34,12114,12115,12120,12123,12126],{},[52,12116,12117],{},[55,12118,12119],{},"A-SI",[52,12121,12122],{},"Comme Type A, sélectif (temporisé)",[52,12124,12125],{},"DDR principal (300 mA), évite le déclenchement en cascade",[52,12127,12128],{},"~80–120 €",[34,12130,12131,12136,12139,12142],{},[52,12132,12133],{},[55,12134,12135],{},"B",[52,12137,12138],{},"Tous les courants de défaut y compris continu lisse",[52,12140,12141],{},"Borne de recharge, pompe à chaleur avec onduleur",[52,12143,12144],{},"~150–250 €",[34,12146,12147,12152,12155,12158],{},[52,12148,12149],{},[55,12150,12151],{},"F",[52,12153,12154],{},"Comme A + courants de défaut à fréquence variable",[52,12156,12157],{},"Entraînements à fréquence variable (moteurs)",[52,12159,12160],{},"~100–180 €",[23,12162,12164],{"id":12163},"quand-le-type-b-est-il-requis","Quand le Type B est-il requis ?",[16,12166,12167,12168,12171],{},"Le Type B est nécessaire lorsqu'un appareil peut générer des ",[55,12169,12170],{},"courants de défaut continus lisses",". Cela concerne principalement :",[444,12173,12174,12180,12186],{},[447,12175,12176,12179],{},[55,12177,12178],{},"Borne de recharge sans détecteur de courant de défaut DC intégré :"," Les bornes simples sans détection DC 6 mA nécessitent un DDR Type B",[447,12181,12182,12185],{},[55,12183,12184],{},"Pompe à chaleur avec onduleur (variateur de fréquence) :"," Le variateur peut générer des courants de défaut DC",[447,12187,12188,12191],{},[55,12189,12190],{},"Onduleur PV sans transformateur :"," Les onduleurs sans transformateur peuvent injecter des composantes DC dans le réseau",[23,12193,12195],{"id":12194},"quand-le-type-a-suffit-il","Quand le Type A suffit-il ?",[16,12197,12198],{},"Le Type A est suffisant pour :",[444,12200,12201,12207,12213],{},[447,12202,12203,12206],{},[55,12204,12205],{},"Borne de recharge AVEC détecteur de courant de défaut DC intégré (6 mA) :"," Le RGIE (Art. 7.22.4) ne prescrit pas un type de DDR précis, mais une fonction : chaque circuit alternatif séparé doit être protégé par un DDR d'au maximum 30 mA dont le fonctionnement reste assuré même en présence d'une composante continue perturbatrice (réalisable notamment avec un Type B) ou qui est combiné à un dispositif de détection de courant continu résiduel (p.ex. Type A + RDC-DD). Un simple Type A seul ne suffit pas pour une borne — la borne doit disposer d'un capteur DC 6 mA intégré qui détecte les courants de défaut DC à partir de 6 mA et interrompt la charge",[447,12208,12209,12212],{},[55,12210,12211],{},"Appareils ménagers normaux :"," Machine à laver, lave-vaisselle, plaque de cuisson, éclairage",[447,12214,12215,12218],{},[55,12216,12217],{},"Circuits prises de courant :"," DDR standard 30 mA Type A",[23,12220,12222],{"id":12221},"exigences-rgie","Exigences RGIE",[28,12224,12225,12234],{},[31,12226,12227],{},[34,12228,12229,12231],{},[37,12230,4459],{},[37,12232,12233],{},"Exigence",[47,12235,12236,12243,12251,12259],{},[34,12237,12238,12240],{},[52,12239,4475],{},[52,12241,12242],{},"Le DDR est obligatoire pour chaque circuit (système TT)",[34,12244,12245,12248],{},[52,12246,12247],{},"Art. 4.2.4.3_b",[52,12249,12250],{},"Maximum 8 circuits départ par DDR 30 mA",[34,12252,12253,12256],{},[52,12254,12255],{},"Art. 5.3.5.3_a",[52,12257,12258],{},"Dispositifs de protection à courant différentiel résiduel dans les installations domestiques au minimum Type A ; au point d'alimentation au minimum 40 A de courant nominal",[34,12260,12261,12264],{},[52,12262,12263],{},"Art. 7.22",[52,12265,12266],{},"Borne de recharge : circuit dédié avec DDR approprié",[23,12268,12270],{"id":12269},"respecter-la-sélectivité","Respecter la sélectivité",[16,12272,12273],{},"Pour une sélectivité correcte, l'installation doit être structurée comme suit :",[937,12275,12276,12282,12288],{},[447,12277,12278,12281],{},[55,12279,12280],{},"DDR principal :"," 300 mA, Type A-SI (sélectif, temporisé)",[447,12283,12284,12287],{},[55,12285,12286],{},"DDR de groupe :"," 30 mA, Type A (pour les circuits normaux)",[447,12289,12290,12293],{},[55,12291,12292],{},"DDR spécial :"," 30 mA, Type B (pour borne de recharge\u002Fpompe à chaleur, si pas de détecteur DC intégré)",[16,12295,12296],{},"Ainsi, en cas de défaut, seul le DDR de groupe concerné déclenche, pas le DDR principal — le reste de l'installation reste en service.",[23,12298,12300],{"id":12299},"différence-de-prix-et-recommandation","Différence de prix et recommandation",[16,12302,12303,12304,12307],{},"La différence de prix entre Type A (~40–60 €) et Type B (~150–250 €) est considérable. Vérifiez donc toujours d'abord si votre borne de recharge ou pompe à chaleur dispose d'un ",[55,12305,12306],{},"détecteur de courant de défaut DC intégré",". Si oui, un DDR Type A moins coûteux suffit. La documentation du fabricant fournit cette information.",[23,12309,2178],{"id":2177},[16,12311,12312,12313,12317],{},"Planifiez vos dispositifs de protection avec ",[262,12314,42],{"href":12315,"rel":12316},"https:\u002F\u002Fwww.planelec.be",[266],". L'auto-contrôle peut signaler certaines configurations de DDR prises en charge, mais ne remplace pas la sélection par un professionnel.",{"title":487,"searchDepth":488,"depth":488,"links":12319},[12320,12321,12322,12323,12324,12325,12326],{"id":12060,"depth":488,"text":12061},{"id":12163,"depth":488,"text":12164},{"id":12194,"depth":488,"text":12195},{"id":12221,"depth":488,"text":12222},{"id":12269,"depth":488,"text":12270},{"id":12299,"depth":488,"text":12300},{"id":2177,"depth":488,"text":2178},"2026-03-25","Comparaison de tous les types de DDR (AC, A, A-SI, B, F) pour les installations électriques belges selon le RGIE.",{},"\u002Fblog\u002Frcd-type-a-vs-b.fr",{"title":12045,"description":12328},"differentiel-type-a-vs-type-b","blog\u002Frcd-type-a-vs-b.fr",[4291,12335,12336,12337,921,12338],"ddr","type-a","type-b","borne-de-recharge","0v9OQW4K1uhnT-woxuJXtDCpJ3uq0r8akbP2pueXudk",{"id":12341,"title":12342,"articleId":12343,"body":12344,"category":2574,"date":12519,"description":12520,"extension":507,"lastUpdated":2234,"locale":508,"meta":12521,"navigation":510,"path":12522,"publishDate":12519,"readTime":12523,"refreshInterval":913,"seo":12524,"slug":12525,"stem":12526,"tags":12527,"__hash__":12531},"blog\u002Fblog\u002Fmain-switch-mandatory.fr.md","Interrupteur général obligatoire : Que prescrit le RGIE ?","main-switch-mandatory",{"type":9,"value":12345,"toc":12511},[12346,12349,12355,12359,12362,12394,12398,12432,12436,12439,12453,12457,12464,12467,12484,12488,12495,12502,12504],[12,12347,12342],{"id":12348},"interrupteur-général-obligatoire-que-prescrit-le-rgie",[16,12350,12351,12354],{},[55,12352,12353],{},"Oui, un interrupteur général est obligatoire en Belgique."," Selon le RGIE Art. 5.3.5.1b, chaque ensemble d'appareillage principal doit disposer d'un interrupteur-sectionneur principal omnipolaire permettant la coupure simultanée de tous les conducteurs actifs et éventuellement du neutre. Le RGIE prescrit un courant nominal d'au moins 40 A pour les installations domestiques (Art. 5.3.5.1b) ; le minimum général est de 25 A. En pratique, un interrupteur-sectionneur est utilisé comme interrupteur principal. Contrairement à un simple sectionneur, il peut être manoeuvré en charge.",[23,12356,12358],{"id":12357},"exigences-pour-linterrupteur-général","Exigences pour l'interrupteur général",[16,12360,12361],{},"L'interrupteur général doit satisfaire les conditions suivantes :",[444,12363,12364,12370,12376,12382,12388],{},[447,12365,12366,12369],{},[55,12367,12368],{},"Omnipolaire :"," Pour un raccordement monophasé, 2 pôles (phase + neutre) ; pour un raccordement triphasé, 4 pôles (3 phases + neutre)",[447,12371,12372,12375],{},[55,12373,12374],{},"Courant nominal au moins 40 A"," pour les installations domestiques (Art. 5.3.5.1b), adapté à l'installation concernée",[447,12377,12378,12381],{},[55,12379,12380],{},"Couper toute l'installation :"," Une seule manoeuvre doit séparer tous les conducteurs actifs",[447,12383,12384,12387],{},[55,12385,12386],{},"Facilement accessible :"," Hauteur de manoeuvre max. 1,80 m (valeur pratique des organismes de contrôle — le RGIE exige uniquement que les ensembles d'appareillage soient 'facilement accessibles sans moyens particuliers' (Art. 5.3.5.1c), sans préciser de hauteur exacte)",[447,12389,12390,12393],{},[55,12391,12392],{},"À l'entrée de l'installation :"," Avant le tableau de distribution, comme premier organe de coupure après le compteur",[23,12395,12397],{"id":12396},"articles-rgie","Articles RGIE",[28,12399,12400,12408],{},[31,12401,12402],{},[34,12403,12404,12406],{},[37,12405,4459],{},[37,12407,12233],{},[47,12409,12410,12417,12424],{},[34,12411,12412,12414],{},[52,12413,4554],{},[52,12415,12416],{},"Interrupteur-sectionneur principal obligatoire, omnipolaire, sur l'ensemble d'appareillage principal",[34,12418,12419,12421],{},[52,12420,4554],{},[52,12422,12423],{},"Courant nominal au moins 40 A pour les installations domestiques, adapté à l'installation concernée",[34,12425,12426,12429],{},[52,12427,12428],{},"Art. 5.3.5.1c",[52,12430,12431],{},"Les ensembles d'appareillage doivent être facilement accessibles et manoeuvrables",[23,12433,12435],{"id":12434},"pourquoi-linterrupteur-général-est-il-si-important","Pourquoi l'interrupteur général est-il si important ?",[16,12437,12438],{},"L'interrupteur général remplit deux fonctions centrales :",[937,12440,12441,12447],{},[447,12442,12443,12446],{},[55,12444,12445],{},"Coupure d'urgence :"," En cas d'urgence (incendie, inondation, électrocution), tout occupant doit pouvoir couper l'ensemble de l'installation d'une seule manoeuvre — même sans connaissances en électricité.",[447,12448,12449,12452],{},[55,12450,12451],{},"Maintenance :"," Pour les travaux sur l'installation électrique, l'ensemble de l'installation doit pouvoir être mise hors tension en toute sécurité.",[23,12454,12456],{"id":12455},"défaut-fréquent-au-contrôle","Défaut fréquent au contrôle",[16,12458,12459,12460,12463],{},"L'interrupteur général absent ou mal dimensionné est l'un des ",[55,12461,12462],{},"défauts les plus fréquents lors du contrôle électrique"," en Belgique. Surtout dans les anciennes installations, il est souvent totalement absent, ou seul un interrupteur unipolaire est installé, qui ne coupe pas le neutre.",[16,12465,12466],{},"Défauts typiques :",[444,12468,12469,12472,12475,12478,12481],{},[447,12470,12471],{},"Aucun interrupteur général présent",[447,12473,12474],{},"Unipolaire au lieu d'omnipolaire",[447,12476,12477],{},"Courant nominal inférieur à 40 A dans une installation domestique",[447,12479,12480],{},"Monté trop haut (pas facilement accessible)",[447,12482,12483],{},"Pas facilement accessible (derrière des meubles, dans un local fermé)",[23,12485,12487],{"id":12486},"interrupteur-général-vs-disjoncteur-principal","Interrupteur général vs. disjoncteur principal",[16,12489,12490,12491,12494],{},"L'interrupteur général n'est ",[55,12492,12493],{},"pas un disjoncteur"," — il n'a pas de fonction de protection contre les surintensités. Il sert exclusivement d'interrupteur de sectionnement. La protection contre les surintensités est assurée par le gestionnaire de réseau (fusible avant le compteur) et les disjoncteurs en aval dans le tableau.",[16,12496,12497,12498,12501],{},"Cependant, un ",[55,12499,12500],{},"disjoncteur principal"," (p.ex. 40 A) peut combiner les deux fonctions : sectionnement et protection contre les surintensités.",[23,12503,2178],{"id":2177},[16,12505,12506,12507,12510],{},"Planifiez votre tableau avec ",[262,12508,42],{"href":12315,"rel":12509},[266],". L'auto-contrôle peut signaler certaines configurations prises en charge, mais ne remplace pas la vérification professionnelle ou le contrôle officiel.",{"title":487,"searchDepth":488,"depth":488,"links":12512},[12513,12514,12515,12516,12517,12518],{"id":12357,"depth":488,"text":12358},{"id":12396,"depth":488,"text":12397},{"id":12434,"depth":488,"text":12435},{"id":12455,"depth":488,"text":12456},{"id":12486,"depth":488,"text":12487},{"id":2177,"depth":488,"text":2178},"2026-03-23","Pourquoi l'interrupteur général est obligatoire en Belgique et quelles exigences le RGIE Art. 5.3.5.1b impose.",{},"\u002Fblog\u002Fmain-switch-mandatory.fr","4 min",{"title":12342,"description":12520},"interrupteur-general-obligatoire-rgie","blog\u002Fmain-switch-mandatory.fr",[12528,921,12529,12530,4290],"interrupteur-general","obligatoire","tableau","Jb2Cgp2et-0vI5Rp5uoV9DKLsbIvIx1fXlHsQ_gLDe4",{"id":12533,"title":12534,"articleId":12535,"body":12536,"category":2574,"date":12810,"description":12811,"extension":507,"lastUpdated":2234,"locale":508,"meta":12812,"navigation":510,"path":12813,"publishDate":12810,"readTime":12523,"refreshInterval":913,"seo":12814,"slug":12815,"stem":12816,"tags":12817,"__hash__":12820},"blog\u002Fblog\u002Fearthing-tt-vs-tns.fr.md","Mise à la terre en Belgique : système TT vs. TN-S expliqué","earthing-tt-vs-tns",{"type":9,"value":12537,"toc":12800},[12538,12542,12548,12552,12559,12563,12570,12574,12681,12683,12741,12745,12759,12762,12773,12777,12784,12788,12791,12793],[12,12539,12541],{"id":12540},"mise-à-la-terre-en-belgique-tt-vs-tn-s","Mise à la terre en Belgique : TT vs. TN-S",[16,12543,12544,12547],{},[55,12545,12546],{},"En Belgique, le système TT est la norme pour les installations résidentielles."," Chaque bâtiment dispose de sa propre prise de terre (électrode de terre), qui assure la mise à la terre indépendamment du réseau de distribution. Le système TN-S, dans lequel le conducteur de protection est fourni par le gestionnaire de réseau, est principalement utilisé pour les nouvelles constructions et les bâtiments industriels.",[23,12549,12551],{"id":12550},"quest-ce-quun-système-tt","Qu'est-ce qu'un système TT ?",[16,12553,12554,12555,12558],{},"Dans le système TT (Terre-Terre), le réseau de distribution a sa propre électrode de terre au transformateur, et l'installation du consommateur dispose d'une ",[55,12556,12557],{},"électrode de terre locale et séparée"," (typiquement un piquet de terre ou une prise de terre de fondation). Le conducteur de protection (PE) n'est pas connecté au neutre du réseau.",[23,12560,12562],{"id":12561},"quest-ce-quun-système-tn-s","Qu'est-ce qu'un système TN-S ?",[16,12564,12565,12566,12569],{},"Dans le système TN-S (Terre Neutre Séparé), le conducteur de protection (PE) est acheminé par le gestionnaire de réseau depuis le transformateur ",[55,12567,12568],{},"séparément du neutre (N)",". La mise à la terre se fait via la connexion au réseau, pas via une électrode locale.",[23,12571,12573],{"id":12572},"tableau-comparatif","Tableau comparatif",[28,12575,12576,12588],{},[31,12577,12578],{},[34,12579,12580,12582,12585],{},[37,12581,5868],{},[37,12583,12584],{},"Système TT",[37,12586,12587],{},"Système TN-S",[47,12589,12590,12603,12616,12629,12642,12655,12668],{},[34,12591,12592,12597,12600],{},[52,12593,12594],{},[55,12595,12596],{},"Source de terre",[52,12598,12599],{},"Piquet de terre\u002Ffondation propre",[52,12601,12602],{},"Conducteur de protection du GRD",[34,12604,12605,12610,12613],{},[52,12606,12607],{},[55,12608,12609],{},"Prévalence en Belgique",[52,12611,12612],{},"Standard (existant + neuf)",[52,12614,12615],{},"Neuf, industriel",[34,12617,12618,12623,12626],{},[52,12619,12620],{},[55,12621,12622],{},"Différentiel obligatoire",[52,12624,12625],{},"300 mA DDR principal + 30 mA DDR de groupe pour prises\u002Flocaux spéciaux (Art. 4.2.4.3)",[52,12627,12628],{},"Depuis RGIE 2020 : DDR 30 mA pour circuits de prises également obligatoire (Art. 4.2.4.3)",[34,12630,12631,12636,12639],{},[52,12632,12633],{},[55,12634,12635],{},"Résistance de terre",[52,12637,12638],{},"Max. 100 Ω limite absolue (Art. 4.2.3.2) ; 30 Ω est le seuil réglementaire (Art. 4.2.4.3_b) — en cas de dépassement, des DDR supplémentaires sont requis",[52,12640,12641],{},"Garantie par le GRD",[34,12643,12644,12649,12652],{},[52,12645,12646],{},[55,12647,12648],{},"Avantage",[52,12650,12651],{},"Indépendant du réseau",[52,12653,12654],{},"Mise à la terre plus fiable",[34,12656,12657,12662,12665],{},[52,12658,12659],{},[55,12660,12661],{},"Inconvénient",[52,12663,12664],{},"Le piquet doit être entretenu",[52,12666,12667],{},"Dépendant du GRD",[34,12669,12670,12675,12678],{},[52,12671,12672],{},[55,12673,12674],{},"Coupure du courant de défaut",[52,12676,12677],{},"Uniquement via différentiel",[52,12679,12680],{},"Aussi via disjoncteur",[23,12682,12222],{"id":12221},[28,12684,12685,12693],{},[31,12686,12687],{},[34,12688,12689,12691],{},[37,12690,4459],{},[37,12692,12233],{},[47,12694,12695,12703,12710,12718,12726,12733],{},[34,12696,12697,12700],{},[52,12698,12699],{},"Art. 4.2.3.2",[52,12701,12702],{},"La résistance de terre dans les installations domestiques doit être inférieure à 100 Ω (limite absolue)",[34,12704,12705,12707],{},[52,12706,12247],{},[52,12708,12709],{},"30 Ω est le seuil réglementaire : en cas de dépassement, au minimum deux DDR 30 mA avec max. 16 prises chacun sont requis",[34,12711,12712,12715],{},[52,12713,12714],{},"Art. 4.2.3.4_c",[52,12716,12717],{},"Formule R_E ≤ U_L \u002F I_A — avec 300 mA et U_L = 50 V, le maximum est d'env. 166 Ω",[34,12719,12720,12723],{},[52,12721,12722],{},"Art. 6.5.2",[52,12724,12725],{},"Visite de contrôle des installations domestiques tous les 25 ans — maintien de la conformité, incl. mesure de la résistance de terre",[34,12727,12728,12730],{},[52,12729,4475],{},[52,12731,12732],{},"Le DDR (protection différentielle) est obligatoire — en TT et depuis le RGIE 2020 aussi en TN-S pour les circuits de prises",[34,12734,12735,12738],{},[52,12736,12737],{},"Art. 9.1",[52,12739,12740],{},"Le type de système de mise à la terre doit être documenté (obligations de documentation)",[23,12742,12744],{"id":12743},"vérifier-le-piquet-de-terre","Vérifier le piquet de terre",[16,12746,12747,12748,12750,12751,12754,12755,12758],{},"Dans un système TT, la résistance de terre doit être mesurée lors de chaque ",[55,12749,2246],{},". Le RGIE Art. 4.2.3.2 fixe pour les installations domestiques une limite absolue de ",[55,12752,12753],{},"100 Ω",". L'Art. 4.2.3.4_c définit la formule R_E ≤ U_L \u002F I_A (avec un DDR principal de 300 mA et U_L = 50 V, le maximum est d'env. 166 Ω). La valeur de ",[55,12756,12757],{},"30 Ω"," est un seuil réglementaire (Art. 4.2.4.3_b) : en cas de dépassement, le RGIE impose des DDR 30 mA supplémentaires. Si la résistance est trop élevée, un piquet de terre supplémentaire ou une prise de terre profonde peut être nécessaire.",[16,12760,12761],{},"Causes typiques d'une résistance de terre trop élevée :",[444,12763,12764,12767,12770],{},[447,12765,12766],{},"Sol sec et sableux",[447,12768,12769],{},"Piquet de terre corrodé",[447,12771,12772],{},"Piquet trop court (minimum 1,50 m de profondeur recommandé)",[23,12774,12776],{"id":12775},"tt-ou-tn-s-lequel-est-meilleur","TT ou TN-S : lequel est meilleur ?",[16,12778,12779,12780,12783],{},"Les deux systèmes sont sûrs s'ils sont correctement installés. En pratique, le système TT a l'avantage de l'",[55,12781,12782],{},"indépendance"," vis-à-vis du réseau de distribution — un défaut sur le réseau n'affecte pas la mise à la terre locale. Depuis le RGIE 2020, un DDR 30 mA pour les circuits de prises (Art. 4.2.4.3) est également obligatoire en TN-S. L'exemption de l'obligation DDR en TN-S ne s'applique qu'à certaines anciennes installations (Part 8).",[23,12785,12787],{"id":12786},"système-tn-c-s","Système TN-C-S",[16,12789,12790],{},"En Belgique, on rencontre aussi le système TN-C-S (fréquent dans les anciennes installations). Le conducteur PEN y est séparé au point de raccordement en conducteur de protection (PE) et neutre (N).",[23,12792,2178],{"id":2177},[16,12794,12795,12796,12799],{},"Documentez votre système de mise à la terre avec ",[262,12797,42],{"href":12315,"rel":12798},[266]," et exportez le schéma unifilaire et le plan de situation en PDF. L'auto-contrôle est indicatif et ne remplace pas le contrôle officiel.",{"title":487,"searchDepth":488,"depth":488,"links":12801},[12802,12803,12804,12805,12806,12807,12808,12809],{"id":12550,"depth":488,"text":12551},{"id":12561,"depth":488,"text":12562},{"id":12572,"depth":488,"text":12573},{"id":12221,"depth":488,"text":12222},{"id":12743,"depth":488,"text":12744},{"id":12775,"depth":488,"text":12776},{"id":12786,"depth":488,"text":12787},{"id":2177,"depth":488,"text":2178},"2026-03-20","Différences entre les systèmes de mise à la terre TT et TN-S pour les installations électriques belges selon le RGIE Art. 4.2.3.2 et 4.2.4.3.",{},"\u002Fblog\u002Fearthing-tt-vs-tns.fr",{"title":12534,"description":12811},"mise-a-la-terre-tt-tns-belgique","blog\u002Fearthing-tt-vs-tns.fr",[4292,12818,12819,921,4293],"systeme-tt","tn-s","553zvdj307IAZ58VY-gD-VFmADncEOQTWPdDiHPoRW4",{"id":12822,"title":12823,"articleId":12824,"body":12825,"category":2574,"date":13238,"description":13239,"extension":507,"lastUpdated":909,"locale":508,"meta":13240,"navigation":510,"path":13241,"publishDate":13238,"readTime":1235,"refreshInterval":913,"seo":13242,"slug":13243,"stem":13244,"tags":13245,"__hash__":13247},"blog\u002Fblog\u002Fcable-cross-section-breaker.fr.md","Section de câble par disjoncteur : Quel câble pour quel disjoncteur ?","cable-cross-section-breaker",{"type":9,"value":12826,"toc":13229},[12827,12831,12837,12841,12844,12954,12958,12961,12966,13110,13117,13122,13126,13170,13174,13184,13188,13196,13206,13210,13217,13220,13222],[12,12828,12830],{"id":12829},"section-de-câble-par-disjoncteur","Section de câble par disjoncteur",[16,12832,12833,12836],{},[55,12834,12835],{},"Le disjoncteur protège le câble, pas l'appareil."," Si un câble trop fin est raccordé à un disjoncteur trop puissant, le câble peut surchauffer et provoquer un incendie. La bonne correspondance entre la section du câble et le courant nominal du disjoncteur est critique pour la sécurité et obligatoire selon le RGIE.",[23,12838,12840],{"id":12839},"aperçu-rapide-disjoncteur-section-minimale","Aperçu rapide : disjoncteur → section minimale",[16,12842,12843],{},"Cet aperçu lit le tableau 4.11 dans le sens où la question se pose sur chantier : le disjoncteur est fixé, on cherche la plus petite section admissible en cuivre.",[28,12845,12846,12858],{},[31,12847,12848],{},[34,12849,12850,12852,12855],{},[37,12851,5843],{},[37,12853,12854],{},"Section minimale du câble",[37,12856,12857],{},"Application typique",[47,12859,12860,12870,12881,12892,12902,12912,12923,12933,12944],{},[34,12861,12862,12865,12868],{},[52,12863,12864],{},"10 A",[52,12866,12867],{},"1,5 mm² (le tableau 4.11 admet 1 mm², mais le tableau 5.1 n’autorise pas cette section en pose fixe)",[52,12869,9923],{},[34,12871,12872,12875,12878],{},[52,12873,12874],{},"16 A",[52,12876,12877],{},"1,5 mm² selon le tableau 4.11 ; au moins 2,5 mm² pour les circuits avec prises selon 5.2.1.2",[52,12879,12880],{},"Éclairage, circuits sans prises",[34,12882,12883,12886,12889],{},[52,12884,12885],{},"20 A",[52,12887,12888],{},"2,5 mm² comme limite issue du tableau 4.11 ; le mode de pose, l’environnement et la chute de tension peuvent imposer davantage",[52,12890,12891],{},"Circuit terminal dédié",[34,12893,12894,12897,12899],{},[52,12895,12896],{},"25 A",[52,12898,3942],{},[52,12900,12901],{},"Circuit terminal à charge plus élevée",[34,12903,12904,12907,12909],{},[52,12905,12906],{},"32 A",[52,12908,3951],{},[52,12910,12911],{},"Plaque de cuisson, chauffe-eau instantané",[34,12913,12914,12917,12920],{},[52,12915,12916],{},"40 A",[52,12918,12919],{},"6 mm² (minimum RGIE selon Tableau 4.11 : 6 mm² → disjoncteur max. 40 A) ; pour les câbles d'alimentation principaux, le 10 mm² est usuel (réserve, chute de tension)",[52,12921,12922],{},"Interrupteur général, câble d'alimentation",[34,12924,12925,12928,12930],{},[52,12926,12927],{},"63 A",[52,12929,3962],{},[52,12931,12932],{},"Alimentation d’un tableau divisionnaire",[34,12934,12935,12938,12941],{},[52,12936,12937],{},"80 A",[52,12939,12940],{},"16 mm²",[52,12942,12943],{},"Câble d’alimentation, interrupteur général",[34,12945,12946,12949,12952],{},[52,12947,12948],{},"100 A",[52,12950,12951],{},"25 mm²",[52,12953,12943],{},[23,12955,12957],{"id":12956},"le-tableau-411-complet","Le tableau 4.11 complet",[16,12959,12960],{},"Le RGIE présente la correspondance dans l’autre sens : pour chaque section de conducteur, le calibre maximal du dispositif de protection — séparément pour le coupe-circuit à fusible et pour le disjoncteur. Pour un même câble, la limite du fusible se situe donc toujours un calibre en dessous de celle du disjoncteur.",[16,12962,12963],{},[258,12964,12965],{},"Tableau 4.11 — Calibre du dispositif de protection en fonction de la section des conducteurs (RGIE 4.4.1.4)",[28,12967,12968,12983],{},[31,12969,12970],{},[34,12971,12972,12975,12978,12980],{},[37,12973,12974],{},"Section du conducteur",[37,12976,12977],{},"Fusible max.",[37,12979,3915],{},[37,12981,12982],{},"Usage en installation domestique",[47,12984,12985,12999,13012,13024,13036,13047,13057,13067,13078,13088,13098],{},[34,12986,12987,12990,12993,12996],{},[52,12988,12989],{},"0,5 mm²",[52,12991,12992],{},"2 A",[52,12994,12995],{},"4 A",[52,12997,12998],{},"uniquement circuits de commande, contrôle et mesure",[34,13000,13001,13004,13006,13009],{},[52,13002,13003],{},"0,75 mm²",[52,13005,12995],{},[52,13007,13008],{},"6 A",[52,13010,13011],{},"uniquement circuits intégrés dans les tableaux",[34,13013,13014,13017,13019,13021],{},[52,13015,13016],{},"1 mm²",[52,13018,13008],{},[52,13020,12864],{},[52,13022,13023],{},"aucune exception admise par le tableau 5.1",[34,13025,13026,13029,13031,13033],{},[52,13027,13028],{},"1,5 mm²",[52,13030,12864],{},[52,13032,12874],{},[52,13034,13035],{},"circuits sans prises de courant",[34,13037,13038,13040,13042,13044],{},[52,13039,5901],{},[52,13041,12874],{},[52,13043,12885],{},[52,13045,13046],{},"admis de manière générale",[34,13048,13049,13051,13053,13055],{},[52,13050,3942],{},[52,13052,12885],{},[52,13054,12896],{},[52,13056,13046],{},[34,13058,13059,13061,13063,13065],{},[52,13060,3951],{},[52,13062,12906],{},[52,13064,12916],{},[52,13066,13046],{},[34,13068,13069,13071,13074,13076],{},[52,13070,3962],{},[52,13072,13073],{},"50 A",[52,13075,12927],{},[52,13077,13046],{},[34,13079,13080,13082,13084,13086],{},[52,13081,12940],{},[52,13083,12927],{},[52,13085,12937],{},[52,13087,13046],{},[34,13089,13090,13092,13094,13096],{},[52,13091,12951],{},[52,13093,12937],{},[52,13095,12948],{},[52,13097,13046],{},[34,13099,13100,13103,13105,13108],{},[52,13101,13102],{},"35 mm²",[52,13104,12948],{},[52,13106,13107],{},"125 A",[52,13109,13046],{},[16,13111,13112,13113,13116],{},"Les trois premières lignes restent hors d’atteinte dans une installation domestique ordinaire. Le RGIE 5.2.1.2 interdit les conducteurs isolés de moins de 2,5 mm² lorsqu’ils ne font pas partie intégrante d’une machine ou d’un appareil. Seules les exceptions du tableau 5.1 sont admises : 1,5 mm² pour les circuits sans prises, 0,75 mm² pour les circuits intégrés dans un tableau alimentant une prise unique, et 0,5 mm² pour les circuits de commande, de contrôle, de signalisation et de mesure. ",[55,13114,13115],{},"Le 1 mm² ne figure pas au tableau 5.1"," : la valeur « fusible 6 A \u002F disjoncteur 10 A » ne mène donc nulle part pour une pose fixe.",[16,13118,13119,13121],{},[55,13120,6146],{}," le tableau 4.11 indique le calibre maximal du disjoncteur selon la section dans une installation domestique. Il ne démontre pas à lui seul que le câble supporte le courant dans toute condition de pose. L’isolation, la constitution, le mode de pose, la température ambiante et la chute de tension doivent encore être évalués. Le tableau ne s’applique pas aux installations non domestiques : le courant admissible y est calculé selon les règles de l’art.",[23,13123,13125],{"id":13124},"bases-rgie","Bases RGIE",[28,13127,13128,13136],{},[31,13129,13130],{},[34,13131,13132,13134],{},[37,13133,4459],{},[37,13135,8522],{},[47,13137,13138,13146,13154,13162],{},[34,13139,13140,13143],{},[52,13141,13142],{},"Art. 4.4.1.4",[52,13144,13145],{},"Tableau 4.11 : Courant nominal maximal du fusible et du disjoncteur selon la section du conducteur dans une installation domestique",[34,13147,13148,13151],{},[52,13149,13150],{},"Art. 5.2.1.2",[52,13152,13153],{},"Choix des conducteurs électriques : sections inférieures à 2,5 mm² interdites, exceptions selon le tableau 5.1 (1,5 mm² pour circuits sans prises)",[34,13155,13156,13159],{},[52,13157,13158],{},"Tableau 5.1",[52,13160,13161],{},"Conducteurs dont la section peut être inférieure à 2,5 mm² : 1,5 mm², 0,75 mm² et 0,5 mm², chacun avec un domaine d’emploi défini",[34,13163,13164,13167],{},[52,13165,13166],{},"Art. 5.2.5",[52,13168,13169],{},"La variation de tension (chute de tension) dans les conducteurs doit être limitée aux valeurs décrites dans les règles de l'art",[23,13171,13173],{"id":13172},"pourquoi-est-ce-important","Pourquoi est-ce important ?",[16,13175,13176,13177,13180,13181],{},"Un câble avec une section trop petite chauffe en cas de charge élevée. Si le disjoncteur est surdimensionné, il ne déclenche pas à temps — le câble surchauffe et il y a ",[55,13178,13179],{},"risque d'incendie",". C'est pourquoi la règle est toujours : ",[55,13182,13183],{},"Le disjoncteur doit être inférieur ou égal à la capacité de charge du câble.",[23,13185,13187],{"id":13186},"tenir-compte-de-la-chute-de-tension","Tenir compte de la chute de tension",[16,13189,13190,13191,268,13193,13195],{},"Pour les longs trajets (par exemple du tableau à la cave vers le garage), la chute de tension peut devenir importante. Le RGIE 5.2.5 ne donne lui-même aucun pourcentage : il renvoie aux règles de l’art. Pour un prédimensionnement, on utilise couramment ",[55,13192,555],{},[55,13194,558],{},". Une section supérieure à la valeur du tableau peut donc être nécessaire.",[16,13197,13198,13199,13202,13203,567],{},"Découvrez comment la longueur, la charge et le nombre de phases interviennent dans le ",[262,13200,13201],{"href":1199},"calcul de chute de tension et de section",", ou utilisez directement le ",[262,13204,13205],{"href":771},"calculateur gratuit",[23,13207,13209],{"id":13208},"erreur-fréquente-lors-du-contrôle","Erreur fréquente lors du contrôle",[16,13211,13212,13213,13216],{},"L'un des défauts les plus fréquents lors du contrôle électrique : ",[55,13214,13215],{},"disjoncteur trop puissant pour la section de câble installée."," Surtout dans les anciennes installations avec des câbles de 1,5 mm² protégés après coup par des disjoncteurs de 20 A.",[16,13218,13219],{},"Lors du remplacement d’anciens fusibles par des disjoncteurs, il vaut la peine de consulter les deux colonnes : un câble de 1,5 mm² sur un fusible de 10 A est admis, sur un disjoncteur de 16 A également — mais pas sur un disjoncteur de 20 A.",[23,13221,2178],{"id":2177},[16,13223,13224,13225,13228],{},"Consignez les sections et protections avec ",[262,13226,42],{"href":13227},"\u002Ffr",". L’auto-contrôle peut signaler certaines combinaisons prises en charge, mais ne remplace pas un calcul professionnel.",{"title":487,"searchDepth":488,"depth":488,"links":13230},[13231,13232,13233,13234,13235,13236,13237],{"id":12839,"depth":488,"text":12840},{"id":12956,"depth":488,"text":12957},{"id":13124,"depth":488,"text":13125},{"id":13172,"depth":488,"text":13173},{"id":13186,"depth":488,"text":13187},{"id":13208,"depth":488,"text":13209},{"id":2177,"depth":488,"text":2178},"2026-03-18","Sections de câble par disjoncteur selon le RGIE 4.4.1.4 et 5.2.1.2 — avec le tableau 4.11 complet pour le coupe-circuit à fusible et le disjoncteur.",{},"\u002Fblog\u002Fcable-cross-section-breaker.fr",{"title":12823,"description":13239},"section-cable-disjoncteur","blog\u002Fcable-cross-section-breaker.fr",[919,2591,921,13246],"installation-electrique","UX_ML5_sjdGR1d8yIRwAm6JlP1vmr8Dd3jIbyIvmxgA",{"id":13249,"title":13250,"articleId":13251,"body":13252,"category":2574,"date":13495,"description":13496,"extension":507,"lastUpdated":13497,"locale":508,"meta":13498,"navigation":510,"path":13499,"publishDate":13495,"readTime":12523,"refreshInterval":913,"seo":13500,"slug":13501,"stem":13502,"tags":13503,"__hash__":13507},"blog\u002Fblog\u002Fxvb-vs-vob-cable.fr.md","Câble XVB vs. VOB : Lequel choisir pour votre installation ?","xvb-vs-vob-cable",{"type":9,"value":13253,"toc":13487},[13254,13258,13264,13268,13271,13275,13282,13284,13388,13390,13426,13430,13441,13460,13479,13481],[12,13255,13257],{"id":13256},"câble-xvb-vs-vob-lequel-choisir","Câble XVB vs. VOB : Lequel choisir ?",[16,13259,13260,13263],{},[55,13261,13262],{},"Le XVB est le câble sous gaine standard pour les installations fixes dans les nouvelles constructions en Belgique."," Il contient plusieurs conducteurs avec une gaine extérieure et peut être posé directement dans les murs, les sols ou les conduits. Le VOB, en revanche, est un fil individuel qui doit toujours être placé dans un tube de protection ou une goulotte.",[23,13265,13267],{"id":13266},"quest-ce-que-le-xvb","Qu'est-ce que le XVB ?",[16,13269,13270],{},"Le XVB (p.ex. XVB 3G2,5) est un câble multiconducteur avec isolation PVC et gaine extérieure PVC. La désignation indique le nombre de conducteurs et la section. Le XVB est conçu pour une pose fixe — dans des saignées murales, sous enduit, dans des conduits ou sur des chemins de câbles.",[23,13272,13274],{"id":13273},"quest-ce-que-le-vob","Qu'est-ce que le VOB ?",[16,13276,13277,13278,13281],{},"Le VOB (p.ex. VOB 2,5mm²) est un fil souple individuel avec isolation PVC. Il ne peut ",[55,13279,13280],{},"jamais être posé librement"," et doit toujours être installé dans un tube de protection (conduit) ou une goulotte. Le VOB est moins cher au mètre, mais nécessite le coût supplémentaire du tube de protection.",[23,13283,12573],{"id":12572},[28,13285,13286,13297],{},[31,13287,13288],{},[34,13289,13290,13292,13294],{},[37,13291,5868],{},[37,13293,12041],{},[37,13295,13296],{},"VOB",[47,13298,13299,13312,13325,13338,13351,13363,13376],{},[34,13300,13301,13306,13309],{},[52,13302,13303],{},[55,13304,13305],{},"Construction",[52,13307,13308],{},"Multiconducteur avec gaine",[52,13310,13311],{},"Fil individuel sans gaine",[34,13313,13314,13319,13322],{},[52,13315,13316],{},[55,13317,13318],{},"Pose",[52,13320,13321],{},"Directe dans mur, sol, conduit",[52,13323,13324],{},"Uniquement dans conduit\u002Fgoulotte",[34,13326,13327,13332,13335],{},[52,13328,13329],{},[55,13330,13331],{},"Tube requis ?",[52,13333,13334],{},"Non (optionnel)",[52,13336,13337],{},"Oui, toujours",[34,13339,13340,13345,13348],{},[52,13341,13342],{},[55,13343,13344],{},"Prix au mètre",[52,13346,13347],{},"Plus élevé (~1,50–3,00 €\u002Fm pour 3G2,5)",[52,13349,13350],{},"Plus bas (~0,30–0,50 €\u002Fm par conducteur)",[34,13352,13353,13357,13360],{},[52,13354,13355],{},[55,13356,6614],{},[52,13358,13359],{},"Souvent moins cher (pas de tube)",[52,13361,13362],{},"Tube + main-d'œuvre = plus cher",[34,13364,13365,13370,13373],{},[52,13366,13367],{},[55,13368,13369],{},"Flexibilité",[52,13371,13372],{},"Plus rigide, difficile à courber",[52,13374,13375],{},"Plus flexible dans le tube",[34,13377,13378,13382,13385],{},[52,13379,13380],{},[55,13381,12857],{},[52,13383,13384],{},"Neuf, rénovation",[52,13386,13387],{},"Rénovation dans conduits existants",[23,13389,12222],{"id":12221},[28,13391,13392,13400],{},[31,13393,13394],{},[34,13395,13396,13398],{},[37,13397,4459],{},[37,13399,12233],{},[47,13401,13402,13410],{},[34,13403,13404,13407],{},[52,13405,13406],{},"Art. 5.2.2",[52,13408,13409],{},"Les câbles doivent être adaptés au mode de pose ; les fils individuels (VOB) uniquement dans des tubes ou goulottes d'installation électrique",[34,13411,13412,13415],{},[52,13413,13414],{},"Art. 5.2.7.2 \u002F 5.2.7.3",[52,13416,13417,13418,11948,13420,13422,13423,13425],{},"Classe de réaction au feu CPR : câbles posés individuellement au minimum ",[55,13419,11947],{},[55,13421,11951],{}," au minimum ",[55,13424,11955],{}," (art. 5.2.7.3, art. 4.3.3.5b)",[23,13427,13429],{"id":13428},"recommandation","Recommandation",[16,13431,13432,13433,13436,13437,13440],{},"Pour les ",[55,13434,13435],{},"nouvelles installations",", le XVB est le premier choix : moins d'étapes de travail, pas de tubes de protection nécessaires et conforme au RGIE. Le VOB convient surtout aux ",[55,13438,13439],{},"rénovations"," où des conduits existent déjà et où des fils individuels doivent être tirés.",[16,13442,13443,13444,13446,13447,13449,13450,1216,13453,13456,13457,13459],{},"Pour les deux types de câbles, veillez à la classe de réaction au feu CPR prescrite — en faisceaux, cloisons creuses et cavités constructives au minimum ",[55,13445,11955],{}," (art. 5.2.7.3), et pour les câbles posés individuellement dans les murs massifs sous enduit ",[55,13448,11947],{}," suffit (art. 5.2.7.2). La classification complémentaire à faible émission de fumée et faible acidité (",[55,13451,13452],{},"s1",[55,13454,13455],{},"a1",") est imposée par l'art. 4.3.3.7 a pour les lieux du tableau 4.10 : voies d'évacuation dans les bâtiments, locaux accessibles au public pouvant recevoir au moins 50 personnes et tunnels. À l'intérieur du logement, elle ne s'applique pas — le tableau 4.10 exclut expressément les installations domestiques. Attention toutefois en immeuble à appartements : les parties communes et locaux techniques d'un immeuble d'habitation ne sont ",[55,13458,3209],{}," des installations domestiques selon la partie 2 du RGIE, l'exigence vaut donc bien dans la cage d'escalier. Les câbles plus anciens sans classification CPR ne peuvent plus être utilisés dans les nouvelles installations.",[1759,13461,13462],{},[16,13463,13464,13467,13468,13471,13472,13475,13476,567],{},[55,13465,13466],{},"Code couleur (art. 5.1.6.2) :"," Le ",[55,13469,13470],{},"vert-jaune"," est réservé au conducteur de protection (PE\u002FPEN), le ",[55,13473,13474],{},"bleu"," au conducteur neutre (N) — ces deux couleurs sont interdites pour les conducteurs actifs (phases). Pour les conducteurs de phase (L1\u002FL2\u002FL3), on utilise donc habituellement le ",[55,13477,13478],{},"brun\u002Fnoir\u002Fgris",[23,13480,2178],{"id":2177},[16,13482,12014,13483,13486],{},[262,13484,42],{"href":12315,"rel":13485},[266],". L'auto-contrôle peut signaler certaines combinaisons de câble et de protection prises en charge, mais ne remplace pas un calcul professionnel.",{"title":487,"searchDepth":488,"depth":488,"links":13488},[13489,13490,13491,13492,13493,13494],{"id":13266,"depth":488,"text":13267},{"id":13273,"depth":488,"text":13274},{"id":12572,"depth":488,"text":12573},{"id":12221,"depth":488,"text":12222},{"id":13428,"depth":488,"text":13429},{"id":2177,"depth":488,"text":2178},"2026-03-16","Comparaison entre le câble sous gaine XVB et le fil VOB pour les installations électriques belges selon le RGIE.","2026-08-18",{},"\u002Fblog\u002Fxvb-vs-vob-cable.fr",{"title":13250,"description":13496},"cable-xvb-vs-vob","blog\u002Fxvb-vs-vob-cable.fr",[13504,13505,13506,6762,921],"câble","xvb","vob","ymobiuj7tzERW5y_4_XnGP97htqbyzdrfAcPhkICmaU",{"id":13509,"title":13510,"articleId":13511,"body":13512,"category":2574,"date":13734,"description":13735,"extension":507,"lastUpdated":2234,"locale":508,"meta":13736,"navigation":510,"path":13737,"publishDate":13734,"readTime":12523,"refreshInterval":913,"seo":13738,"slug":13739,"stem":13740,"tags":13741,"__hash__":13750},"blog\u002Fblog\u002Finspection-checklist.fr.md","Que vérifie le contrôleur lors du contrôle électrique ?","inspection-checklist",{"type":9,"value":13513,"toc":13726},[13514,13518,13521,13525,13528,13552,13559,13563,13566,13623,13627,13630,13700,13703,13708,13710,13721],[23,13515,13517],{"id":13516},"trois-domaines-documentation-contrôle-visuel-mesures","Trois domaines : documentation, contrôle visuel, mesures",[16,13519,13520],{},"Le contrôleur vérifie votre installation électrique en trois étapes successives. Si la documentation est déjà manquante, le contrôle s'arrête généralement là — c'est un échec automatique.",[23,13522,13524],{"id":13523},"_1-documentation","1. Documentation",[16,13526,13527],{},"Le contrôleur exige les documents suivants :",[444,13529,13530,13535,13540,13546],{},[447,13531,13532,13534],{},[55,13533,147],{}," — présent, complet et à jour ?",[447,13536,13537,13539],{},[55,13538,159],{}," — plan des pièces avec prises, interrupteurs et luminaires indiqués ?",[447,13541,13542,13545],{},[55,13543,13544],{},"Déclaration de conformité"," de l'installateur ?",[447,13547,13548,13551],{},[55,13549,13550],{},"Fiches techniques"," — tableau de distribution, différentiels, disjoncteurs ?",[1759,13553,13554],{},[16,13555,13556,13558],{},[55,13557,2003],{}," : La raison la plus fréquente d'échec au contrôle est un schéma unifilaire manquant ou erroné. Sans documentation correcte, le contrôleur ne procède dans la plupart des cas pas aux mesures.",[23,13560,13562],{"id":13561},"_2-contrôle-visuel","2. Contrôle visuel",[16,13564,13565],{},"Ensuite, le contrôleur vérifie visuellement l'installation :",[444,13567,13568,13573,13579,13586,13592,13598,13605,13612,13618],{},[447,13569,13570,13572],{},[55,13571,3909],{}," correcte par disjoncteur ? (ex. min. 2,5 mm² pour 16A pour circuits de prises ; pour l'éclairage 1,5 mm² pour 16A suffit)",[447,13574,13575,13578],{},[55,13576,13577],{},"Différentiel 30mA"," présent pour tous les circuits de prises ?",[447,13580,13581,13582,13585],{},"Maximum ",[55,13583,13584],{},"8 circuits par différentiel"," ?",[447,13587,13588,13591],{},[55,13589,13590],{},"Zones de salle de bain"," respectées ? (Zone 0, 1, 2 selon RGIE Art. 7.1, définitions des zones Art. 7.1.3.2)",[447,13593,13594,13597],{},[55,13595,13596],{},"Raccordement de terre"," présent et accessible ?",[447,13599,13600,13601,13604],{},"Toutes les ",[55,13602,13603],{},"boîtes de dérivation"," fermées ?",[447,13606,13607,13608,13611],{},"Câbles correctement ",[55,13609,13610],{},"fixés"," et protégés ?",[447,13613,13614,13617],{},[55,13615,13616],{},"Interrupteur principal"," présent et librement accessible ?",[447,13619,13620,13622],{},[55,13621,5162],{}," présente ? (Art. 4.5.1 exige de manière générale la protection contre les surtensions selon les règles de l'art — en pratique, un SPD Type 2 est recommandé)",[23,13624,13626],{"id":13625},"_3-mesures","3. Mesures",[16,13628,13629],{},"Enfin, le contrôleur effectue des mesures techniques :",[28,13631,13632,13644],{},[31,13633,13634],{},[34,13635,13636,13638,13641],{},[37,13637,9472],{},[37,13639,13640],{},"Limite",[37,13642,13643],{},"Instrument",[47,13645,13646,13656,13667,13678,13689],{},[34,13647,13648,13650,13653],{},[52,13649,12635],{},[52,13651,13652],{},"\u003C 100 Ohm (Art. 4.2.4.3 a\u002Fb) ; au-delà de 30 Ohm, au moins deux différentiels à haute sensibilité requis",[52,13654,13655],{},"Telluromètre",[34,13657,13658,13661,13664],{},[52,13659,13660],{},"Résistance d'isolement",[52,13662,13663],{},"> 0,5 MOhm",[52,13665,13666],{},"Mégohmmètre (Megger)",[34,13668,13669,13672,13675],{},[52,13670,13671],{},"Impédance de boucle",[52,13673,13674],{},"Selon courant nominal MCB",[52,13676,13677],{},"Mesureur d'impédance de boucle",[34,13679,13680,13683,13686],{},[52,13681,13682],{},"Temps de déclenchement différentiel",[52,13684,13685],{},"\u003C 300 ms au courant différentiel nominal I∆n, \u003C 40 ms à 5× I∆n (selon IEC 61008)",[52,13687,13688],{},"Testeur de différentiel",[34,13690,13691,13694,13697],{},[52,13692,13693],{},"Mesure de tension",[52,13695,13696],{},"230V ±10%",[52,13698,13699],{},"Multimètre",[23,13701,1282],{"id":13702},"résultat",[16,13704,4320,13705,13707],{},[55,13706,3609],{},". Pour les nouvelles constructions et les rénovations importantes, le contrôle doit être réussi avant que le gestionnaire de réseau n'active le raccordement électrique. En cas de défauts, vous recevez un délai pour les corrections et devez planifier un nouveau contrôle.",[23,13709,2178],{"id":2177},[444,13711,13712,13716],{},[447,13713,13714],{},[262,13715,3567],{"href":856},[447,13717,13718],{},[262,13719,13720],{"href":2556},"Combien de prises par circuit ? (Limites RGIE)",[16,13722,13723],{},[262,13724,13725],{"href":1216},"Créez votre schéma unifilaire conforme RGIE — gratuit →",{"title":487,"searchDepth":488,"depth":488,"links":13727},[13728,13729,13730,13731,13732,13733],{"id":13516,"depth":488,"text":13517},{"id":13523,"depth":488,"text":13524},{"id":13561,"depth":488,"text":13562},{"id":13625,"depth":488,"text":13626},{"id":13702,"depth":488,"text":1282},{"id":2177,"depth":488,"text":2178},"2026-03-13","Documentation, contrôle visuel, mesures — découvrez point par point ce que le contrôleur vérifie et mesure réellement lors d'un contrôle électrique en Belgique.",{},"\u002Fblog\u002Finspection-checklist.fr",{"title":13510,"description":13735},"checklist-controle","blog\u002Finspection-checklist.fr",[1240,521,7449,13742,518,13743,519,13744,13745,13746,13747,1241,13748,13749],"checklist","eendraadschema","Situationsplan","différentiel","résistance de terre","résistance d'isolement","Eindrahtschema","single-line diagram","nKUUwWFs5PZ-fJa9Ot4DhysXY3c5EQPw_ShH0YK871s",{"id":13752,"title":13720,"articleId":13753,"body":13754,"category":2574,"date":13956,"description":13957,"extension":507,"lastUpdated":2234,"locale":508,"meta":13958,"navigation":510,"path":13959,"publishDate":13956,"readTime":2579,"refreshInterval":913,"seo":13960,"slug":13961,"stem":13962,"tags":13963,"__hash__":13966},"blog\u002Fblog\u002Fsockets-per-circuit.fr.md","sockets-per-circuit",{"type":9,"value":13755,"toc":13948},[13756,13760,13774,13778,13825,13829,13885,13889,13892,13912,13922,13926,13932,13934,13944],[23,13757,13759],{"id":13758},"maximum-8-prises-par-circuit","Maximum 8 prises par circuit",[16,13761,13762,13763,13766,13767,13769,13770,13773],{},"Le RGIE stipule à l'",[55,13764,13765],{},"Art. 5.3.5.2b"," : un maximum de ",[55,13768,10055],{}," peut être installé par circuit terminal. Cette limite de huit points s'applique exclusivement aux prises, pas aux points lumineux. Une règle de comptage importante s'applique — une prise double compte comme ",[55,13771,13772],{},"un"," seul point, pas deux.",[23,13775,13777],{"id":13776},"règles-de-comptage-en-détail","Règles de comptage en détail",[28,13779,13780,13789],{},[31,13781,13782],{},[34,13783,13784,13786],{},[37,13785,1055],{},[37,13787,13788],{},"Compte comme",[47,13790,13791,13798,13804,13811,13818],{},[34,13792,13793,13795],{},[52,13794,11136],{},[52,13796,13797],{},"1 point",[34,13799,13800,13802],{},[52,13801,11151],{},[52,13803,13797],{},[34,13805,13806,13809],{},[52,13807,13808],{},"Prise triple",[52,13810,13797],{},[34,13812,13813,13816],{},[52,13814,13815],{},"Point lumineux",[52,13817,13797],{},[34,13819,13820,13823],{},[52,13821,13822],{},"Raccordement fixe (four, taque)",[52,13824,5126],{},[23,13826,13828],{"id":13827},"câble-et-disjoncteur-par-type-de-circuit","Câble et disjoncteur par type de circuit",[28,13830,13831,13845],{},[31,13832,13833],{},[34,13834,13835,13838,13840,13842],{},[37,13836,13837],{},"Type de circuit",[37,13839,2283],{},[37,13841,5843],{},[37,13843,13844],{},"Max. points",[47,13846,13847,13859,13872],{},[34,13848,13849,13852,13854,13857],{},[52,13850,13851],{},"Prises",[52,13853,6099],{},[52,13855,13856],{},"16A ou 20A",[52,13858,4561],{},[34,13860,13861,13863,13866,13869],{},[52,13862,9923],{},[52,13864,13865],{},"XVB 3G1,5",[52,13867,13868],{},"10A ou 16A",[52,13870,13871],{},"aucun maximum fixe (min. 2 circuits éclairage si >2 pièces)",[34,13873,13874,13877,13880,13883],{},[52,13875,13876],{},"Dédié (four)",[52,13878,13879],{},"XVB 3G4 ou 3G6",[52,13881,13882],{},"20A ou 32A",[52,13884,4469],{},[23,13886,13888],{"id":13887},"exemple-pratique-maison-unifamiliale-typique","Exemple pratique : maison unifamiliale typique",[16,13890,13891],{},"Une maison unifamiliale avec 3 chambres, cuisine, salle de bain et salon nécessite généralement :",[444,13893,13894,13900,13906],{},[447,13895,13896,13899],{},[55,13897,13898],{},"5 à 7 circuits prises"," (pièces de vie, cuisine, chambres)",[447,13901,13902,13905],{},[55,13903,13904],{},"3 à 4 circuits éclairage"," (rez-de-chaussée, étage, éclairage extérieur)",[447,13907,13908,13911],{},[55,13909,13910],{},"3 à 4 circuits dédiés"," (four, taque de cuisson, lave-vaisselle, sèche-linge)",[1759,13913,13914],{},[16,13915,13916,13918,13919,13921],{},[55,13917,2003],{}," : Les cuisines nécessitent souvent des circuits dédiés pour le lave-vaisselle, le four et la taque de cuisson. Ces appareils sont raccordés en fixe et ne comptent ",[55,13920,3209],{}," comme des prises normales — chacun dispose de son propre circuit avec un câble plus fort et un disjoncteur adapté.",[23,13923,13925],{"id":13924},"installations-existantes-rgie-partie-8","Installations existantes (RGIE Partie 8)",[16,13927,13928,13929,13931],{},"Pour les installations existantes construites avant le RGIE actuel, la ",[55,13930,8788],{}," autorise plus de 8 prises par circuit sous certaines conditions — à condition que la puissance des appareils raccordés n'excède pas la puissance admise pour la canalisation et que la section du câble soit suffisamment dimensionnée. Toutefois, en cas de rénovation ou d'extension, les limites actuelles s'appliquent.",[23,13933,2178],{"id":2177},[444,13935,13936,13940],{},[447,13937,13938],{},[262,13939,2551],{"href":2550},[447,13941,13942],{},[262,13943,3567],{"href":856},[16,13945,13946],{},[262,13947,13725],{"href":1216},{"title":487,"searchDepth":488,"depth":488,"links":13949},[13950,13951,13952,13953,13954,13955],{"id":13758,"depth":488,"text":13759},{"id":13776,"depth":488,"text":13777},{"id":13827,"depth":488,"text":13828},{"id":13887,"depth":488,"text":13888},{"id":13924,"depth":488,"text":13925},{"id":2177,"depth":488,"text":2178},"2026-03-11","Maximum 8 points par circuit — mais comment compter correctement ? Découvrez les règles du RGIE pour les prises, l'éclairage et les circuits dédiés.",{},"\u002Fblog\u002Fsockets-per-circuit.fr",{"title":13720,"description":13957},"prises-par-circuit","blog\u002Fsockets-per-circuit.fr",[1240,521,13964,13965,2591,13504,12041,518,13743,2246,5014,1241,13748,519],"prise","circuit","CuP3oufI4QI004jlNTttYMGnVB-HCOAdhV_1ywFgiJw",{"id":13968,"title":13969,"articleId":13970,"body":13971,"category":2574,"date":14337,"description":14338,"extension":507,"lastUpdated":2234,"locale":508,"meta":14339,"navigation":510,"path":14340,"publishDate":14337,"readTime":12523,"refreshInterval":913,"seo":14341,"slug":14342,"stem":14343,"tags":14344,"__hash__":14350},"blog\u002Fblog\u002Fbathroom-cables-arei-zones.fr.md","Quels câbles utiliser dans la salle de bain ? (Zones RGIE)","bathroom-cables-arei-zones",{"type":9,"value":13972,"toc":14326},[13973,13977,13987,13991,13998,14057,14068,14071,14075,14182,14186,14215,14219,14280,14284,14291,14302,14306,14309,14311,14321],[23,13974,13976],{"id":13975},"le-xvb-est-toujours-autorisé-le-vob-sous-conditions","Le XVB est toujours autorisé — le VOB sous conditions",[16,13978,13979,13980,13982,13983,13986],{},"L'installation électrique dans la salle de bain est soumise à des règles particulières en Belgique. La règle de base : le ",[55,13981,6156],{}," (câble sous gaine) est autorisé dans toutes les zones de la salle de bain en dehors de la zone 0. Le ",[55,13984,13985],{},"fil VOB en conduit"," (Preflex) est soumis à des restrictions — notamment dans les cloisons creuses.",[23,13988,13990],{"id":13989},"les-zones-rgie-de-la-salle-de-bain","Les zones RGIE de la salle de bain",[16,13992,13993,13994,13997],{},"Le RGIE définit ",[55,13995,13996],{},"trois zones"," autour de la baignoire et de la douche : zone 0, zone 1, zone 2 (uniquement pour les baignoires) et la zone hors périmètre (art. 7.1.3.2).",[28,13999,14000,14013],{},[31,14001,14002],{},[34,14003,14004,14007,14010],{},[37,14005,14006],{},"Zone",[37,14008,14009],{},"Périmètre",[37,14011,14012],{},"Installation autorisée",[47,14014,14015,14028,14041],{},[34,14016,14017,14022,14025],{},[52,14018,14019],{},[55,14020,14021],{},"Zone 0",[52,14023,14024],{},"Intérieur de la baignoire\u002Fdouche",[52,14026,14027],{},"TBTS ≤ 12V uniquement, IPX7",[34,14029,14030,14035,14038],{},[52,14031,14032],{},[55,14033,14034],{},"Zone 1",[52,14036,14037],{},"Verticalement au-dessus de la zone 0, jusqu'à 2,25 m de hauteur",[52,14039,14040],{},"Appareils fixes ≥ IPX4 ; prises TBTS et interrupteurs TBTS autorisés (art. 7.1.5.2c n° 2 et 4)",[34,14042,14043,14048,14054],{},[52,14044,14045],{},[55,14046,14047],{},"Zone 2",[52,14049,14050,14051],{},"60 cm autour de la zone 1 — ",[55,14052,14053],{},"uniquement pour les baignoires",[52,14055,14056],{},"Prises uniquement avec différentiel à très haute sensibilité (≤ 10 mA) ou transformateur de séparation de 100 W (art. 7.1.5.2d n° 2) ; appareils ≥ IPX4",[1759,14058,14059],{},[16,14060,14061,14063,14064,14067],{},[55,14062,6146],{}," La zone 2 n'est ",[55,14065,14066],{},"pas définie"," pour les douches (art. 7.1.3.2 n° 3b). Pour les douches, la zone 1 est directement suivie de la zone hors périmètre.",[16,14069,14070],{},"En dehors de ces zones, les règles d'installation normales s'appliquent.",[23,14072,14074],{"id":14073},"types-de-câbles-et-leur-admissibilité","Types de câbles et leur admissibilité",[28,14076,14077,14094],{},[31,14078,14079],{},[34,14080,14081,14083,14085,14087,14089,14091],{},[37,14082,6084],{},[37,14084,11818],{},[37,14086,14021],{},[37,14088,14034],{},[37,14090,14047],{},[37,14092,14093],{},"Hors zones",[47,14095,14096,14112,14129,14146,14165],{},[34,14097,14098,14102,14104,14106,14108,14110],{},[52,14099,14100],{},[55,14101,6099],{},[52,14103,11955],{},[52,14105,2911],{},[52,14107,150],{},[52,14109,150],{},[52,14111,150],{},[34,14113,14114,14118,14120,14122,14125,14127],{},[52,14115,14116],{},[55,14117,13865],{},[52,14119,11955],{},[52,14121,2911],{},[52,14123,14124],{},"Oui (éclairage)",[52,14126,150],{},[52,14128,150],{},[34,14130,14131,14136,14138,14140,14142,14144],{},[52,14132,14133],{},[55,14134,14135],{},"VOB en Preflex gris",[52,14137,254],{},[52,14139,2911],{},[52,14141,150],{},[52,14143,150],{},[52,14145,150],{},[34,14147,14148,14153,14155,14157,14160,14163],{},[52,14149,14150],{},[55,14151,14152],{},"VOB en Preflex vert",[52,14154,254],{},[52,14156,2911],{},[52,14158,14159],{},"Non (cloison creuse)",[52,14161,14162],{},"Restreint",[52,14164,150],{},[34,14166,14167,14172,14174,14176,14178,14180],{},[52,14168,14169],{},[55,14170,14171],{},"H07Z1-U (sans halogène)",[52,14173,11955],{},[52,14175,2911],{},[52,14177,150],{},[52,14179,150],{},[52,14181,150],{},[367,14183,14185],{"id":14184},"notes-importantes-sur-les-types-de-câbles","Notes importantes sur les types de câbles",[444,14187,14188,14193,14203,14209],{},[447,14189,14190,14192],{},[55,14191,12041],{}," (câble sous gaine) : Toujours le choix sûr. Adapté pour l'encastrement, le montage en saillie et les chemins de câbles.",[447,14194,14195,14198,14199,14202],{},[55,14196,14197],{},"Preflex gris"," (conduit standard avec VOB pré-tiré) : Autorisé dans les murs massifs. ",[55,14200,14201],{},"Interdit"," dans les cloisons creuses et faux plafonds.",[447,14204,14205,14208],{},[55,14206,14207],{},"Preflex Safe (vert)"," : Dans les murs massifs, le Preflex Safe (Cca) est autorisé même en zone 1. La restriction concerne les cloisons creuses (construction sèche), pas la zone elle-même.",[447,14210,14211,14214],{},[55,14212,14213],{},"H07Z1-U"," : Fil sans halogène, particulièrement recommandé pour les zones sensibles. Note : le H07Z1-U en tant que fil individuel n'a pas de classe CPR Cca inhérente — la classe se réfère au système de câblage (fil + conduit). Le H07Z1-U en Preflex Safe atteint Cca.",[23,14216,14218],{"id":14217},"tableau-des-sections","Tableau des sections",[28,14220,14221,14232],{},[31,14222,14223],{},[34,14224,14225,14227,14230],{},[37,14226,11122],{},[37,14228,14229],{},"Section min.",[37,14231,5843],{},[47,14233,14234,14242,14250,14260,14269],{},[34,14235,14236,14238,14240],{},[52,14237,9923],{},[52,14239,13028],{},[52,14241,13868],{},[34,14243,14244,14246,14248],{},[52,14245,13851],{},[52,14247,5901],{},[52,14249,13856],{},[34,14251,14252,14255,14257],{},[52,14253,14254],{},"Lave-linge \u002F sèche-linge",[52,14256,5901],{},[52,14258,14259],{},"16A (circuit dédié)",[34,14261,14262,14265,14267],{},[52,14263,14264],{},"Chauffe-eau électrique (sous évier, ≤ 2 kW)",[52,14266,5901],{},[52,14268,3928],{},[34,14270,14271,14274,14277],{},[52,14272,14273],{},"Chauffe-eau instantané (18–27 kW)",[52,14275,14276],{},"6 mm² (32A) ou 10 mm² (40A, triphasé)",[52,14278,14279],{},"32A ou 40A",[23,14281,14283],{"id":14282},"la-protection-différentielle-30ma-est-obligatoire","La protection différentielle 30mA est obligatoire",[16,14285,14286,14287,14290],{},"Selon l'article 7.1.4.3 du RGIE, ",[55,14288,14289],{},"tous les circuits de la salle de bain"," doivent être protégés par un différentiel à haute ou très haute sensibilité (typiquement 30 mA) — à l'exception des circuits TBTS, des circuits à séparation électrique et des installations de sécurité. Cela s'applique aussi bien à l'éclairage qu'aux prises et aux appareils fixes.",[1759,14292,14293],{},[16,14294,14295,14297,14298,14301],{},[55,14296,2003],{}," : Même les circuits qui ne font que ",[258,14299,14300],{},"traverser"," la salle de bain (par exemple, des câbles vers les combles) doivent respecter les exigences des zones s'ils passent à l'intérieur des zones de protection.",[23,14303,14305],{"id":14304},"liaison-équipotentielle-dans-la-salle-de-bain","Liaison équipotentielle dans la salle de bain",[16,14307,14308],{},"Important : le RGIE (art. 7.1.4.4) exige une liaison équipotentielle supplémentaire dans la salle de bain — toutes les parties métalliques simultanément accessibles (conduites d'eau, radiateurs, baignoire, tuyaux d'évacuation) doivent être reliées localement entre elles et aux conducteurs de protection des circuits de la salle de bain. L'absence de liaison équipotentielle est un motif fréquent de non-conformité lors du contrôle.",[23,14310,2178],{"id":2177},[444,14312,14313,14317],{},[447,14314,14315],{},[262,14316,2551],{"href":2550},[447,14318,14319],{},[262,14320,3567],{"href":856},[16,14322,14323],{},[262,14324,14325],{"href":1216},"Planifiez l'électricité de votre salle de bain avec PlanElec — gratuit →",{"title":487,"searchDepth":488,"depth":488,"links":14327},[14328,14329,14330,14333,14334,14335,14336],{"id":13975,"depth":488,"text":13976},{"id":13989,"depth":488,"text":13990},{"id":14073,"depth":488,"text":14074,"children":14331},[14332],{"id":14184,"depth":497,"text":14185},{"id":14217,"depth":488,"text":14218},{"id":14282,"depth":488,"text":14283},{"id":14304,"depth":488,"text":14305},{"id":2177,"depth":488,"text":2178},"2026-03-09","Le XVB est toujours autorisé, le VOB en conduit seulement sous conditions. Découvrez quels types de câbles sont autorisés dans chaque zone RGIE.",{},"\u002Fblog\u002Fbathroom-cables-arei-zones.fr",{"title":13969,"description":14338},"cables-salle-de-bain-rgie","blog\u002Fbathroom-cables-arei-zones.fr",[1240,521,1799,14345,12041,13296,14346,14347,13745,14348,2246,5014,1241,518,13743,519,14349],"zones","Preflex","câbles","30mA","CPR","hc3YRUsC3jb5q4ZpZfM02fE4vg-csXF6E99UgpOx1OM",{"id":14352,"title":458,"articleId":14353,"body":14354,"category":2574,"date":14580,"description":14581,"extension":507,"lastUpdated":2234,"locale":508,"meta":14582,"navigation":510,"path":14583,"publishDate":14580,"readTime":2579,"refreshInterval":913,"seo":14584,"slug":14585,"stem":14586,"tags":14587,"__hash__":14590},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.fr.md","what-is-a-situation-plan",{"type":9,"value":14355,"toc":14571},[14356,14360,14373,14379,14381,14387,14427,14430,14434,14438,14467,14471,14549,14552,14554,14566],[23,14357,14359],{"id":14358},"un-plan-au-sol-de-votre-installation-électrique","Un plan au sol de votre installation électrique",[16,14361,14362,14363,14366,14367,14369,14370,14372],{},"Le plan de situation (néerlandais : ",[258,14364,14365],{},"situatieschema",", allemand : ",[258,14368,13744],{},") est un plan à l'échelle de votre bâtiment montrant la ",[55,14371,10936],{}," de tous les composants électriques — prises, interrupteurs, luminaires, tableaux de distribution et chemins de câbles.",[16,14374,14375,14376,14378],{},"Contrairement au schéma unifilaire, le plan de situation ne montre pas la hiérarchie logique des circuits, mais ",[55,14377,10920],{}," tout se trouve.",[23,14380,11937],{"id":11936},[16,14382,14383,14384,583],{},"Selon le RGIE Art. 9.1 (Art. 269 dans l'ancien RGIE, depuis 2020 Art. 9.1), toute installation électrique en Belgique doit disposer de ",[55,14385,14386],{},"deux documents graphiques obligatoires",[28,14388,14389,14401],{},[31,14390,14391],{},[34,14392,14393,14396,14398],{},[37,14394,14395],{},"Document",[37,14397,4459],{},[37,14399,14400],{},"Montre",[47,14402,14403,14415],{},[34,14404,14405,14409,14412],{},[52,14406,14407],{},[55,14408,147],{},[52,14410,14411],{},"Art. 9.1.2 Nr. 1",[52,14413,14414],{},"Structure logique — dispositifs de protection, circuits, hiérarchie",[34,14416,14417,14421,14424],{},[52,14418,14419],{},[55,14420,159],{},[52,14422,14423],{},"Art. 9.1.2 Nr. 2",[52,14425,14426],{},"Position physique — où tout est installé dans le bâtiment, y compris l'emplacement du compteur et du système de mise à la terre",[16,14428,14429],{},"Les deux documents doivent être présentés lors de chaque contrôle électrique. Si l'un d'entre eux manque, le contrôle ne sera pas réussi.",[23,14431,14433],{"id":14432},"que-doit-contenir-le-plan-de-situation","Que doit contenir le plan de situation ?",[367,14435,14437],{"id":14436},"liste-de-vérification","Liste de vérification",[444,14439,14440,14443,14446,14449,14452,14455,14458,14461,14464],{},[447,14441,14442],{},"Plan à l'échelle de chaque étage",[447,14444,14445],{},"Position de toutes les prises (simple, double, avec terre)",[447,14447,14448],{},"Position de tous les interrupteurs (on\u002Foff, va-et-vient, variateur)",[447,14450,14451],{},"Points lumineux (plafond, mur, extérieur)",[447,14453,14454],{},"Tableau de distribution et emplacement du compteur",[447,14456,14457],{},"Appareils fixes (plaque de cuisson, chauffe-eau, borne de recharge)",[447,14459,14460],{},"Chemins de câbles et zones d'installation",[447,14462,14463],{},"Numéros de référence des circuits (doivent correspondre au schéma unifilaire)",[447,14465,14466],{},"Symboles conformes au RGIE (selon le tableau 2.23 du RGIE, chapitre 2.13)",[23,14468,14470],{"id":14469},"plan-de-situation-vs-schéma-unifilaire","Plan de situation vs. schéma unifilaire",[28,14472,14473,14484],{},[31,14474,14475],{},[34,14476,14477,14480,14482],{},[37,14478,14479],{},"Propriété",[37,14481,159],{},[37,14483,147],{},[47,14485,14486,14497,14507,14517,14528,14539],{},[34,14487,14488,14491,14494],{},[52,14489,14490],{},"Représentation",[52,14492,14493],{},"Plan au sol physique",[52,14495,14496],{},"Schéma logique des circuits",[34,14498,14499,14502,14505],{},[52,14500,14501],{},"Montre la position ?",[52,14503,14504],{},"Oui — emplacement exact",[52,14506,2911],{},[34,14508,14509,14512,14514],{},[52,14510,14511],{},"Montre la hiérarchie ?",[52,14513,2911],{},[52,14515,14516],{},"Oui — du réseau au consommateur",[34,14518,14519,14522,14525],{},[52,14520,14521],{},"Dispositifs de protection",[52,14523,14524],{},"Position uniquement",[52,14526,14527],{},"Calibres, type, coordination",[34,14529,14530,14533,14536],{},[52,14531,14532],{},"Info câbles",[52,14534,14535],{},"Chemins visibles",[52,14537,14538],{},"Type et section indiqués",[34,14540,14541,14544,14547],{},[52,14542,14543],{},"À l'échelle",[52,14545,14546],{},"Oui (1:50 ou 1:100)",[52,14548,2911],{},[16,14550,14551],{},"Les deux documents se complètent et sont également obligatoires.",[23,14553,2178],{"id":2177},[444,14555,14556,14561],{},[447,14557,14558],{},[262,14559,14560],{"href":451},"Créer un schéma unifilaire — étape par étape",[447,14562,14563],{},[262,14564,14565],{"href":2191},"Combien coûte un plan électrique en Belgique ?",[16,14567,14568],{},[262,14569,14570],{"href":1216},"Créez votre plan de situation avec PlanElec — gratuit →",{"title":487,"searchDepth":488,"depth":488,"links":14572},[14573,14574,14575,14578,14579],{"id":14358,"depth":488,"text":14359},{"id":11936,"depth":488,"text":11937},{"id":14432,"depth":488,"text":14433,"children":14576},[14577],{"id":14436,"depth":497,"text":14437},{"id":14469,"depth":488,"text":14470},{"id":2177,"depth":488,"text":2178},"2026-03-06","Le plan de situation montre où tous les composants électriques sont physiquement installés dans votre bâtiment. Découvrez ce qu'il doit contenir et comment il se distingue du schéma unifilaire.",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.fr",{"title":458,"description":14581},"plan-de-situation","blog\u002Fwhat-is-a-situation-plan.fr",[1240,521,519,14365,13744,14588,518,13743,13748,2246,14589,1241],"situation plan","plan au sol","X6ppGJN74AI2FIOg-2CW1sb2MKE2JVCPLfJpt718W18",{"id":14592,"title":2551,"articleId":14593,"body":14594,"category":2574,"date":14757,"description":14758,"extension":507,"lastUpdated":2234,"locale":508,"meta":14759,"navigation":510,"path":14760,"publishDate":14757,"readTime":2579,"refreshInterval":913,"seo":14761,"slug":14762,"stem":14763,"tags":14764,"__hash__":14766},"blog\u002Fblog\u002F30ma-rcd-per-socket.fr.md","30ma-rcd-per-socket",{"type":9,"value":14595,"toc":14749},[14596,14600,14610,14612,14615,14656,14660,14702,14706,14709,14723,14726,14733,14735,14745],[23,14597,14599],{"id":14598},"non-mais-chaque-circuit-de-prises-en-a-besoin","Non — mais chaque circuit de prises en a besoin",[16,14601,14602,14603,14605,14606,14609],{},"Une idée reçue courante : il n'est ",[55,14604,3209],{}," nécessaire d'installer un différentiel 30mA dédié pour chaque prise individuelle. L'exigence du RGIE porte sur les ",[55,14607,14608],{},"circuits",", pas sur les points de connexion individuels. Un seul différentiel 30mA protège généralement plusieurs prises raccordées au même circuit.",[23,14611,11937],{"id":11936},[16,14613,14614],{},"Le RGIE (Règlement Général sur les Installations Électriques) précise dans plusieurs articles quand une protection différentielle 30mA est obligatoire :",[28,14616,14617,14626],{},[31,14618,14619],{},[34,14620,14621,14624],{},[37,14622,14623],{},"Article",[37,14625,12233],{},[47,14627,14628,14637,14646],{},[34,14629,14630,14634],{},[52,14631,14632],{},[55,14633,12247],{},[52,14635,14636],{},"Les circuits de prises (ainsi que l'éclairage, salle de bain\u002Fdouche, lave-linge\u002Fsèche-linge\u002Flave-vaisselle) doivent être protégés par un différentiel 30mA",[34,14638,14639,14643],{},[52,14640,14641],{},[55,14642,12247],{},[52,14644,14645],{},"Maximum 8 circuits départ par différentiel 30mA (ne s'applique pas à la protection 300mA au point d'alimentation)",[34,14647,14648,14653],{},[52,14649,14650],{},[55,14651,14652],{},"Art. 7.1.4.3",[52,14654,14655],{},"Dans la salle de bain, la protection 30mA est toujours obligatoire (Chapitre 7.1 pour les locaux avec baignoire\u002Fdouche)",[367,14657,14659],{"id":14658},"limites-essentielles","Limites essentielles",[28,14661,14662,14670],{},[31,14663,14664],{},[34,14665,14666,14668],{},[37,14667,39],{},[37,14669,13640],{},[47,14671,14672,14679,14687,14694],{},[34,14673,14674,14677],{},[52,14675,14676],{},"Max. circuits par différentiel 30mA",[52,14678,4561],{},[34,14680,14681,14684],{},[52,14682,14683],{},"Max. prises par circuit",[52,14685,14686],{},"8 (obligatoire selon Art. 5.3.5.2_b)",[34,14688,14689,14692],{},[52,14690,14691],{},"Courant nominal circuit prises",[52,14693,13856],{},[34,14695,14696,14699],{},[52,14697,14698],{},"Section min. du câble prises",[52,14700,14701],{},"min. 2,5 mm² (indépendamment de la protection 16 A ou 20 A ; pour l'éclairage 1,5 mm² suffit à 16 A)",[23,14703,14705],{"id":14704},"exemple-pratique","Exemple pratique",[16,14707,14708],{},"Une maison unifamiliale typique possède par exemple 6 circuits de prises. Ceux-ci peuvent être répartis sur deux différentiels 30mA :",[444,14710,14711,14717],{},[447,14712,14713,14716],{},[55,14714,14715],{},"Diff 1"," (30mA, Type A) : prises salon, couloir, chambre 1 — 3 circuits",[447,14718,14719,14722],{},[55,14720,14721],{},"Diff 2"," (30mA, Type A) : prises cuisine, chambre 2, bureau — 3 circuits",[16,14724,14725],{},"Ainsi, si un différentiel se déclenche, toute la maison ne perd pas le courant, et vous restez sous la limite de 8 circuits par différentiel.",[1759,14727,14728],{},[16,14729,14730,14732],{},[55,14731,2003],{}," : Pour les salles de bain (Art. 7.1.4.3), le RGIE prescrit des mesures de protection particulières. Dans les installations domestiques (Art. 4.2.4.3_b), les circuits des locaux avec baignoire et\u002Fou douche doivent être protégés par un dispositif de protection à courant différentiel résiduel à haute sensibilité (30 mA).",[23,14734,2178],{"id":2177},[444,14736,14737,14741],{},[447,14738,14739],{},[262,14740,14560],{"href":451},[447,14742,14743],{},[262,14744,3567],{"href":856},[16,14746,14747],{},[262,14748,13725],{"href":1216},{"title":487,"searchDepth":488,"depth":488,"links":14750},[14751,14752,14755,14756],{"id":14598,"depth":488,"text":14599},{"id":11936,"depth":488,"text":11937,"children":14753},[14754],{"id":14658,"depth":497,"text":14659},{"id":14704,"depth":488,"text":14705},{"id":2177,"depth":488,"text":2178},"2026-03-04","Non — mais par circuit. Découvrez ce que le RGIE exige et quand un différentiel 30mA est obligatoire.",{},"\u002Fblog\u002F30ma-rcd-per-socket.fr",{"title":2551,"description":14758},"30ma-ddr-par-prise","blog\u002F30ma-rcd-per-socket.fr",[1240,521,13745,14765,14348,13964,13965,2246,5014,1241,518,13743,519],"disjoncteur différentiel","e1CShyMiP8BtwT3565CygFmYxzxu0f-FzfKTN4cM3qQ",{"id":14768,"title":14769,"articleId":14770,"body":14771,"category":906,"date":15054,"description":15055,"extension":507,"lastUpdated":2234,"locale":508,"meta":15056,"navigation":510,"path":15057,"publishDate":15058,"readTime":912,"refreshInterval":913,"seo":15059,"slug":15060,"stem":15061,"tags":15062,"__hash__":15065},"blog\u002Fblog\u002Felectrical-plan-costs.fr.md","Combien coûte un plan électrique ? Comparaison des prix 2026","electrical-plan-costs",{"type":9,"value":14772,"toc":15038},[14773,14777,14786,14790,14793,14843,14854,14858,14861,14868,14879,14885,14889,14895,14899,14902,14906,14909,14940,14944,14947,14951,14992,14996,14999,15003,15006,15025,15028,15030,15033],[23,14774,14776],{"id":14775},"combien-coûte-un-plan-électrique-chez-un-électricien","Combien coûte un plan électrique chez un électricien ?",[16,14778,14779,14780,14782,14783,14785],{},"Que vous vendiez un bien immobilier, prépariez un contrôle ou planifiiez une nouvelle installation — vous avez besoin d'un ",[55,14781,518],{}," et d'un ",[55,14784,519],{},". Mais combien cela coûte-t-il réellement ? Nous avons recherché les prix actuels du marché en Belgique.",[23,14787,14789],{"id":14788},"prix-actuels-du-marché-en-belgique-2026","Prix actuels du marché en Belgique (2026)",[16,14791,14792],{},"Le coût de la documentation électrique varie selon le prestataire, la région et la complexité de votre installation :",[28,14794,14795,14805],{},[31,14796,14797],{},[34,14798,14799,14802],{},[37,14800,14801],{},"Service",[37,14803,14804],{},"Fourchette de prix",[47,14806,14807,14815,14822,14829,14835],{},[34,14808,14809,14812],{},[52,14810,14811],{},"Schéma unifilaire + plan de situation (appartement jusqu'à 110 m²)",[52,14813,14814],{},"269 € – 400 €",[34,14816,14817,14820],{},[52,14818,14819],{},"Schéma unifilaire + plan de situation (maison unifamiliale)",[52,14821,2030],{},[34,14823,14824,14827],{},[52,14825,14826],{},"Plan électrique construction neuve (complet)",[52,14828,2030],{},[34,14830,14831,14833],{},[52,14832,3468],{},[52,14834,2048],{},[34,14836,14837,14840],{},[52,14838,14839],{},"Mise en conformité de l'installation",[52,14841,14842],{},"1 000 € – 7 000 €+",[1759,14844,14845],{},[16,14846,14847,14849,14850,14853],{},[55,14848,2003],{}," : Ces prix concernent uniquement la ",[258,14851,14852],{},"documentation"," — pas l'installation électrique elle-même. Un électricien facture séparément la création des plans.",[23,14855,14857],{"id":14856},"quand-avez-vous-besoin-de-quels-documents","Quand avez-vous besoin de quels documents ?",[367,14859,6838],{"id":14860},"vente-immobilière",[16,14862,14863,14864,14867],{},"Lors de la vente d'un bien en Belgique, un ",[55,14865,14866],{},"rapport de conformité"," de l'installation électrique est légalement obligatoire. Vous aurez besoin de :",[444,14869,14870,14873,14876],{},[447,14871,14872],{},"Un schéma unifilaire à jour",[447,14874,14875],{},"Un plan de situation",[447,14877,14878],{},"Le rapport de contrôle",[16,14880,14881,14882,567],{},"Si vos plans existants sont obsolètes ou inexistants (ce qui est fréquent avec les bâtiments anciens), vous devrez les faire refaire — ",[55,14883,14884],{},"coût typique : 269 € – 600 €",[367,14886,14888],{"id":14887},"préparation-au-contrôle","Préparation au contrôle",[16,14890,14891,14892,567],{},"Lors des contrôles périodiques ou de la première réception, l'inspecteur vérifie que votre documentation correspond à l'installation réelle. Des plans manquants ou incorrects sont l'une des ",[55,14893,14894],{},"raisons les plus courantes d'échec",[367,14896,14898],{"id":14897},"nouvelle-installation-ou-rénovation","Nouvelle installation ou rénovation",[16,14900,14901],{},"Pour une construction neuve ou une rénovation majeure, un plan électrique complet est obligatoire — incluant le calcul des câbles, la disposition du tableau et la validation RGIE.",[23,14903,14905],{"id":14904},"quest-ce-qui-influence-le-prix","Qu'est-ce qui influence le prix ?",[16,14907,14908],{},"Plusieurs facteurs déterminent le coût :",[444,14910,14911,14917,14923,14928,14934],{},[447,14912,14913,14916],{},[55,14914,14915],{},"Taille de l'installation"," — Plus de pièces et de circuits = prix plus élevé",[447,14918,14919,14922],{},[55,14920,14921],{},"Complexité"," — Triphasé, panneaux solaires, borne de recharge, etc.",[447,14924,14925,14927],{},[55,14926,5647],{}," — Les prix varient entre la Flandre, la Wallonie et Bruxelles",[447,14929,14930,14933],{},[55,14931,14932],{},"Urgence"," — Un service express coûte souvent 50 à 100 % de plus",[447,14935,14936,14939],{},[55,14937,14938],{},"Tarif horaire de l'électricien"," — En moyenne 40 à 60 €\u002Fheure",[23,14941,14943],{"id":14942},"lalternative-abordable-créez-vos-plans-vous-même-avec-planelec","L'alternative abordable : créez vos plans vous-même avec PlanElec",[16,14945,14946],{},"Et si vous pouviez créer les plans vous-même — sans compétences CAO, en une fraction du temps et à une fraction du coût ?",[367,14948,14950],{"id":14949},"état-tarifaire-de-planelec","État tarifaire de PlanElec",[28,14952,14953,14962],{},[31,14954,14955],{},[34,14956,14957,14959],{},[37,14958,11122],{},[37,14960,14961],{},"Situation actuelle",[47,14963,14964,14974,14984],{},[34,14965,14966,14969],{},[52,14967,14968],{},"Early Access",[52,14970,14971],{},[55,14972,14973],{},"Actuellement gratuit",[34,14975,14976,14979],{},[52,14977,14978],{},"Paiement",[52,14980,14981],{},[55,14982,14983],{},"Pas encore activé",[34,14985,14986,14989],{},[52,14987,14988],{},"Pilote B2B payant",[52,14990,14991],{},"Prévu ; les conditions seront publiées avant l'activation",[367,14993,14995],{"id":14994},"ce-que-vous-obtenez-avec-planelec","Ce que vous obtenez avec PlanElec",[16,14997,14998],{},"L'Early Access actuel comprend la planification du projet, le plan, la topologie\nélectrique, la planification du tableau, le schéma unifilaire et le plan de situation\nen PDF ainsi qu'un rapport d'auto-contrôle indicatif. La liste de matériel, le dossier\ncomplet et le devis restent sur la feuille de route.",[23,15000,15002],{"id":15001},"exemple-concret-vente-immobilière","Exemple concret : Vente immobilière",[16,15004,15005],{},"Supposons que vous vendiez une maison unifamiliale et que vous ayez besoin de plans électriques mis à jour :",[444,15007,15008,15017,15023],{},[447,15009,15010,15013,15014],{},[55,15011,15012],{},"Chez un électricien"," : Schéma unifilaire + plan de situation = env. ",[55,15015,15016],{},"400 €",[447,15018,15019,15022],{},[55,15020,15021],{},"Avec PlanElec"," : Early Access actuellement sans frais de produit",[447,15024,7306],{},[16,15026,15027],{},"Et le meilleur : vous pouvez mettre à jour vos plans à tout moment si quelque chose change — sans devoir faire appel à un électricien.",[23,15029,6672],{"id":6671},[16,15031,15032],{},"PlanElec est actuellement gratuit pendant l'Early Access. Le rapport d'auto-contrôle ne remplace ni la vérification professionnelle d'un électricien ni le contrôle officiel d'un organisme agréé.",[16,15034,15035],{},[262,15036,15037],{"href":1216},"Commencez gratuitement et vérifiez votre installation →",{"title":487,"searchDepth":488,"depth":488,"links":15039},[15040,15041,15042,15047,15048,15052,15053],{"id":14775,"depth":488,"text":14776},{"id":14788,"depth":488,"text":14789},{"id":14856,"depth":488,"text":14857,"children":15043},[15044,15045,15046],{"id":14860,"depth":497,"text":6838},{"id":14887,"depth":497,"text":14888},{"id":14897,"depth":497,"text":14898},{"id":14904,"depth":488,"text":14905},{"id":14942,"depth":488,"text":14943,"children":15049},[15050,15051],{"id":14949,"depth":497,"text":14950},{"id":14994,"depth":497,"text":14995},{"id":15001,"depth":488,"text":15002},{"id":6671,"depth":488,"text":6672},"2026-02-19","Prix actuels du marché pour les schémas unifilaires et plans de situation en Belgique — et comment PlanElec vous fait économiser jusqu'à 92%.",{},"\u002Fblog\u002Felectrical-plan-costs.fr",null,{"title":14769,"description":15055},"cout-plan-electrique","blog\u002Felectrical-plan-costs.fr",[1240,521,518,13743,519,13744,15063,15064,11747,2246,4662,3608,1241,13748,13749],"coût","prix","oK8H_BIBtnuRzACHQ93wXBZK0qfcHg7XAO1uUJ0Jnos",{"id":15067,"title":15068,"articleId":15069,"body":15070,"category":906,"date":15326,"description":15327,"extension":507,"lastUpdated":2234,"locale":508,"meta":15328,"navigation":510,"path":15329,"publishDate":15058,"readTime":512,"refreshInterval":913,"seo":15330,"slug":4289,"stem":15331,"tags":15332,"__hash__":15336},"blog\u002Fblog\u002Felectrical-inspection.fr.md","Contrôle Électrique en Belgique : Le Guide Complet 2026","electrical-inspection",{"type":9,"value":15071,"toc":15315},[15072,15076,15082,15085,15089,15092,15128,15136,15140,15143,15147,15150,15172,15176,15179,15202,15206,15209,15229,15233,15236,15262,15265,15267,15273,15305,15310],[23,15073,15075],{"id":15074},"quest-ce-quun-contrôle-électrique","Qu'est-ce qu'un Contrôle Électrique ?",[16,15077,15078,15079,15081],{},"En Belgique, toute installation électrique doit être contrôlée par un organisme agréé avant de pouvoir être raccordée au réseau. Ce contrôle vérifie que votre installation est conforme au ",[55,15080,521],{}," (Règlement Général sur les Installations Électriques), également connu sous le nom d'AREI en néerlandais.",[16,15083,15084],{},"Que vous construisiez une nouvelle maison, rénoviez un bien existant ou vendiez votre propriété, un contrôle électrique est obligatoire. Un échec peut retarder votre projet de plusieurs semaines et vous coûter des centaines d'euros en frais supplémentaires.",[23,15086,15088],{"id":15087},"quand-avez-vous-besoin-dun-contrôle","Quand avez-vous besoin d'un contrôle ?",[16,15090,15091],{},"Un contrôle électrique est requis dans les situations suivantes :",[444,15093,15094,15100,15106,15111,15116,15122],{},[447,15095,15096,15099],{},[55,15097,15098],{},"Nouvelles installations"," : Avant le premier raccordement au réseau électrique",[447,15101,15102,15105],{},[55,15103,15104],{},"Rénovations importantes"," : Lorsque vous modifiez ou étendez l'installation existante",[447,15107,15108,15110],{},[55,15109,9217],{}," : Tous les 25 ans pour les bâtiments résidentiels",[447,15112,15113,15115],{},[55,15114,6838],{}," : Visite de contrôle lors de la vente d'une unité d'habitation",[447,15117,15118,15121],{},[55,15119,15120],{},"Après un rapport d'infraction"," : Recontrôle après correction des problèmes identifiés",[447,15123,15124,15127],{},[55,15125,15126],{},"Changement d'affectation"," : Lors du passage d'un usage résidentiel à commercial",[1759,15129,15130],{},[16,15131,15132,15135],{},[55,15133,15134],{},"Bon à savoir"," : Même si vous n'ajoutez que quelques nouveaux circuits, un recontrôle complet peut être déclenché. Vérifiez toujours auprès de votre électricien ou organisme de contrôle au préalable.",[23,15137,15139],{"id":15138},"comment-se-préparer-au-contrôle","Comment se préparer au contrôle",[16,15141,15142],{},"Une bonne préparation est la clé pour réussir votre contrôle électrique du premier coup. Voici ce dont vous avez besoin :",[367,15144,15146],{"id":15145},"_1-documentation-requise","1. Documentation requise",[16,15148,15149],{},"L'inspecteur demandera les documents suivants :",[444,15151,15152,15157,15162,15167],{},[447,15153,15154,15156],{},[55,15155,147],{}," — Un aperçu schématique de tous les circuits, dispositifs de protection et raccordements",[447,15158,15159,15161],{},[55,15160,159],{}," — Indique l'emplacement physique de tous les composants électriques",[447,15163,15164,15166],{},[55,15165,13544],{}," de l'installateur",[447,15168,15169,15171],{},[55,15170,13550],{}," des composants principaux (disjoncteurs, différentiels, etc.)",[367,15173,15175],{"id":15174},"_2-exigences-de-linstallation","2. Exigences de l'installation",[16,15177,15178],{},"Assurez-vous que votre installation répond à ces exigences de base :",[444,15180,15181,15184,15187,15190,15193,15196,15199],{},[447,15182,15183],{},"Tous les circuits sont correctement protégés par des disjoncteurs",[447,15185,15186],{},"Un différentiel de 300mA protège l'ensemble de l'installation",[447,15188,15189],{},"Protection différentielle supplémentaire de 30mA (haute ou très haute sensibilité) pour les circuits de prises de courant, l'éclairage, les pièces humides (salle de bain\u002Fdouche), ainsi que les lave-linge, sèche-linge et lave-vaisselle",[447,15191,15192],{},"Mise à la terre correcte avec une résistance maximale de 30 Ohms (RGIE Art. 4.2.4.3b : en cas de dépassement de 30 Ω, des dispositifs différentiels à haute sensibilité supplémentaires sont requis ; formule générale : R_A × I∆n ≤ 50 V)",[447,15194,15195],{},"Tous les câbles sont correctement fixés et protégés",[447,15197,15198],{},"Les boîtes de dérivation sont accessibles et correctement fermées",[447,15200,15201],{},"Au moins deux circuits d'éclairage séparés pour les appartements de plus de deux pièces (Art. 5.3.5.2b)",[367,15203,15205],{"id":15204},"_3-erreurs-courantes-à-éviter","3. Erreurs courantes à éviter",[16,15207,15208],{},"Selon les statistiques de contrôle, voici les raisons d'échec les plus fréquentes :",[444,15210,15211,15214,15217,15220,15223,15226],{},[447,15212,15213],{},"Schéma unifilaire manquant ou incorrect",[447,15215,15216],{},"Protection différentielle insuffisante",[447,15218,15219],{},"Résistance de terre trop élevée",[447,15221,15222],{},"Câbles mal fixés ou non protégés",[447,15224,15225],{},"Couvercles manquants sur les boîtes de dérivation",[447,15227,15228],{},"Moins de deux circuits d'éclairage séparés pour les appartements de plus de deux pièces",[23,15230,15232],{"id":15231},"que-se-passe-t-il-pendant-le-contrôle","Que se passe-t-il pendant le contrôle ?",[16,15234,15235],{},"Le contrôle dure généralement entre 1 et 3 heures, selon la taille de l'installation. L'inspecteur va :",[937,15237,15238,15244,15250,15256],{},[447,15239,15240,15243],{},[55,15241,15242],{},"Vérifier la documentation"," — S'assurer que le schéma unifilaire et le plan de situation correspondent à l'installation réelle",[447,15245,15246,15249],{},[55,15247,15248],{},"Inspection visuelle"," — Contrôler tous les composants, câbles et connexions visibles",[447,15251,15252,15255],{},[55,15253,15254],{},"Effectuer des mesures"," — Tester la résistance de terre, la résistance d'isolement et l'impédance de boucle",[447,15257,15258,15261],{},[55,15259,15260],{},"Tests fonctionnels"," — Tester tous les différentiels et disjoncteurs",[16,15263,15264],{},"Après le contrôle, vous recevrez un rapport détaillé listant les éventuelles infractions. En cas de réussite, vous obtiendrez un certificat vert valable 25 ans.",[23,15266,4735],{"id":4734},[16,15268,15269,15270,15272],{},"La création de la documentation requise est souvent la partie la plus chronophage de la préparation d'un contrôle électrique. ",[55,15271,42],{}," simplifie considérablement ce processus :",[444,15274,15275,15281,15287,15293,15299],{},[447,15276,15277,15280],{},[55,15278,15279],{},"Générer des schémas unifilaires"," en quelques minutes au lieu de plusieurs heures",[447,15282,15283,15286],{},[55,15284,15285],{},"Conforme au RGIE"," — Tous les symboles et mises en page respectent la réglementation belge",[447,15288,15289,15292],{},[55,15290,15291],{},"Plans de situation automatiques"," basés sur votre agencement de pièces",[447,15294,15295,15298],{},[55,15296,15297],{},"Export en PDF"," pour une soumission facile à l'inspecteur",[447,15300,15301,15304],{},[55,15302,15303],{},"Support multilingue"," — Documentation en néerlandais, français, allemand ou anglais",[1759,15306,15307],{},[16,15308,15309],{},"Arrêtez de vous inquiéter pour la documentation. Concentrez-vous sur votre installation et laissez PlanElec gérer la paperasse.",[16,15311,15312],{},[262,15313,15314],{"href":1216},"Commencez gratuitement votre documentation électrique →",{"title":487,"searchDepth":488,"depth":488,"links":15316},[15317,15318,15319,15324,15325],{"id":15074,"depth":488,"text":15075},{"id":15087,"depth":488,"text":15088},{"id":15138,"depth":488,"text":15139,"children":15320},[15321,15322,15323],{"id":15145,"depth":497,"text":15146},{"id":15174,"depth":497,"text":15175},{"id":15204,"depth":497,"text":15205},{"id":15231,"depth":488,"text":15232},{"id":4734,"depth":488,"text":4735},"2026-01-08","Tout ce que vous devez savoir sur le contrôle électrique — de la préparation à l'inspection finale.",{},"\u002Fblog\u002Felectrical-inspection.fr",{"title":15068,"description":15327},"blog\u002Felectrical-inspection.fr",[1240,521,2246,15333,518,13743,519,13744,15334,13745,15335,4662,1241,13748,13749],"keuring","conformité","mise à la terre","n33qv488-1H37KI-JxLROL4dK4p-AsoGA3YaYkQiF6Q",{"id":15338,"title":15339,"articleId":15340,"body":15341,"category":15798,"date":15799,"description":15800,"extension":507,"lastUpdated":15801,"locale":508,"meta":15802,"navigation":510,"path":15803,"publishDate":15058,"readTime":15804,"refreshInterval":913,"seo":15805,"slug":5530,"stem":15806,"tags":15807,"__hash__":15808},"blog\u002Fblog\u002Fsingle-line-diagram.fr.md","Schéma unifilaire en Belgique : guide RGIE étape par étape","single-line-diagram",{"type":9,"value":15342,"toc":15773},[15343,15350,15354,15362,15365,15367,15370,15402,15409,15413,15416,15419,15442,15446,15472,15476,15495,15499,15503,15506,15531,15535,15538,15567,15570,15574,15577,15591,15595,15598,15623,15627,15634,15637,15641,15645,15648,15652,15655,15659,15662,15676,15680,15683,15687,15719,15723,15726,15740,15745,15749],[1759,15344,15345],{},[16,15346,15347,15349],{},[55,15348,10928],{}," le schéma unifilaire représente la structure électrique de l'installation, du tableau aux circuits et aux récepteurs. En Belgique, il fait partie du dossier utilisé lors du contrôle. Ce guide explique les symboles, les informations à reprendre, la méthode de création et l'export PDF.",[23,15351,15353],{"id":15352},"quest-ce-quun-schéma-unifilaire","Qu'est-ce qu'un schéma unifilaire ?",[16,15355,15356,15357,14366,15359,15361],{},"Un schéma unifilaire (néerlandais : ",[258,15358,13743],{},[258,15360,13748],{},") est un schéma électrique simplifié qui représente la structure de votre installation complète à l'aide de symboles standardisés. Contrairement à un schéma de câblage qui montre chaque conducteur individuel, un schéma unifilaire utilise une seule ligne pour représenter chaque circuit.",[16,15363,15364],{},"Ce document fait partie des pièces demandées en Belgique lors du contrôle électrique selon le RGIE. Il doit être à jour et correspondre à l'installation réelle ; le contrôle officiel reste du ressort d'un organisme agréé.",[23,15366,13173],{"id":13172},[16,15368,15369],{},"Le schéma unifilaire remplit plusieurs fonctions essentielles :",[444,15371,15372,15378,15384,15390,15396],{},[447,15373,15374,15377],{},[55,15375,15376],{},"Obligation légale"," — Obligatoire pour tout contrôle électrique en Belgique",[447,15379,15380,15383],{},[55,15381,15382],{},"Vue d'ensemble de la sécurité"," — Montre tous les dispositifs de protection et leur coordination",[447,15385,15386,15389],{},[55,15387,15388],{},"Référence de maintenance"," — Aide les électriciens à identifier rapidement les circuits et composants",[447,15391,15392,15395],{},[55,15393,15394],{},"Planification des modifications"," — Indispensable pour planifier les changements futurs",[447,15397,15398,15401],{},[55,15399,15400],{},"Documentation immobilière"," — Requis lors de la vente d'un bien",[1759,15403,15404],{},[16,15405,15406,15408],{},[55,15407,2901],{}," : Le schéma unifilaire doit refléter fidèlement l'état actuel de l'installation. Toute modification de l'installation nécessite une mise à jour du schéma.",[23,15410,15412],{"id":15411},"comprendre-les-symboles-rgie","Comprendre les symboles RGIE",[16,15414,15415],{},"Le RGIE prescrit des symboles spécifiques basés sur la norme IEC 60617. Voici les plus importants :",[367,15417,14521],{"id":15418},"dispositifs-de-protection",[444,15420,15421,15426,15431,15437],{},[447,15422,15423,15425],{},[55,15424,5843],{}," — Protège contre les surintensités",[447,15427,15428,15430],{},[55,15429,6407],{}," (differentieelschakelaar) — Protège contre les fuites à la terre",[447,15432,15433,15436],{},[55,15434,15435],{},"Fusible"," (smeltzekering) — Protection traditionnelle contre les surintensités",[447,15438,15439,15441],{},[55,15440,13616],{}," (hoofdschakelaar) — Déconnecte l'ensemble de l'installation",[367,15443,15445],{"id":15444},"consommateurs","Consommateurs",[444,15447,15448,15454,15460,15466],{},[447,15449,15450,15453],{},[55,15451,15452],{},"Prise de courant"," — Représentée par un symbole en demi-cercle",[447,15455,15456,15459],{},[55,15457,15458],{},"Point d'éclairage"," — Cercle avec rayons ou croix",[447,15461,15462,15465],{},[55,15463,15464],{},"Appareil fixe"," — Rectangle avec désignation de l'appareil",[447,15467,15468,15471],{},[55,15469,15470],{},"Moteur"," — Cercle avec désignation M",[367,15473,15475],{"id":15474},"symboles-spéciaux","Symboles spéciaux",[444,15477,15478,15484,15490],{},[447,15479,15480,15483],{},[55,15481,15482],{},"Mise à la terre"," — Trois lignes horizontales de longueur décroissante",[447,15485,15486,15489],{},[55,15487,15488],{},"Liaison équipotentielle"," — Ligne de connexion avec symbole de terre",[447,15491,15492,15494],{},[55,15493,7988],{}," — Ligne en zigzag avec flèche",[23,15496,15498],{"id":15497},"guide-étape-par-étape-avec-planelec","Guide étape par étape avec PlanElec",[367,15500,15502],{"id":15501},"étape-1-définir-votre-installation","Étape 1 : Définir votre installation",[16,15504,15505],{},"Commencez par cartographier votre installation électrique :",[937,15507,15508,15511,15514],{},[447,15509,15510],{},"Ouvrez PlanElec et créez un nouveau projet",[447,15512,15513],{},"Définissez les pièces de votre bâtiment (salon, cuisine, chambres, etc.)",[447,15515,15516,15517],{},"Pour chaque pièce, spécifiez les composants électriques :\n",[444,15518,15519,15522,15525,15528],{},[447,15520,15521],{},"Nombre et type de prises (simple, double, avec broche de terre)",[447,15523,15524],{},"Points d'éclairage (plafond, mur, commuté)",[447,15526,15527],{},"Appareils fixes (four, plaque de cuisson, chauffe-eau, etc.)",[447,15529,15530],{},"Circuits spéciaux (borne de recharge VE, pompe à chaleur, panneaux solaires)",[367,15532,15534],{"id":15533},"étape-2-configurer-les-dispositifs-de-protection","Étape 2 : Configurer les dispositifs de protection",[16,15536,15537],{},"PlanElec suggère automatiquement une protection appropriée :",[444,15539,15540,15550,15556,15562],{},[447,15541,15542,15545,15546,15549],{},[55,15543,15544],{},"Différentiel principal"," — Maximum 300 mA au point d'alimentation (Art. 4.2.4.3b), de préférence ",[55,15547,15548],{},"sélectif (Type S\u002Ftemporisé)"," afin d'assurer la sélectivité avec les différentiels 30 mA situés en aval (état de la technique)",[447,15551,15552,15555],{},[55,15553,15554],{},"Différentiels 30 mA supplémentaires"," — Pour les prises (hors appareils fixes), l'éclairage, les salles de bains, lave-linge\u002Fsèche-linge\u002Flave-vaisselle (Art. 4.2.4.3b) ; max. 8 circuits terminaux par RCD 30 mA",[447,15557,15558,15561],{},[55,15559,15560],{},"Disjoncteurs"," — Dimensionnés selon la section du câble et le type de circuit",[447,15563,15564,15566],{},[55,15565,10343],{}," — Si requise par votre type d'installation",[16,15568,15569],{},"Vous pouvez ajuster ces suggestions en fonction de vos besoins spécifiques ou des recommandations de votre électricien.",[367,15571,15573],{"id":15572},"étape-3-vérifier-la-topologie","Étape 3 : Vérifier la topologie",[16,15575,15576],{},"PlanElec génère automatiquement la topologie des circuits :",[444,15578,15579,15582,15585,15588],{},[447,15580,15581],{},"Les circuits sont regroupés logiquement (éclairage, prises, circuits dédiés)",[447,15583,15584],{},"Chaque circuit reçoit un identifiant unique (ex. : A1, A2, B1, B2)",[447,15586,15587],{},"La hiérarchie de l'interrupteur principal au consommateur final est clairement visible",[447,15589,15590],{},"Les sections de câble sont indiquées pour chaque circuit",[367,15592,15594],{"id":15593},"étape-4-générer-et-exporter","Étape 4 : Générer et exporter",[16,15596,15597],{},"PlanElec reconstruit le schéma unifilaire à partir des circuits, protections, câbles et récepteurs saisis dans le projet :",[444,15599,15600,15606,15612,15618],{},[447,15601,15602,15605],{},[55,15603,15604],{},"Représentation adaptée au contexte belge"," — Structure lisible du tableau vers les circuits et les récepteurs",[447,15607,15608,15611],{},[55,15609,15610],{},"Catalogue de symboles"," — Symboles électriques pour le contexte de planification belge",[447,15613,15614,15617],{},[55,15615,15616],{},"Étiquetage automatique"," — Références de circuits, types de câbles et valeurs de protection",[447,15619,15620,15622],{},[55,15621,3502],{}," — Sortie documentaire centralisée pour vérification professionnelle",[23,15624,15626],{"id":15625},"exemple-de-schéma-unifilaire-en-pdf","Exemple de schéma unifilaire en PDF",[16,15628,768,15629,15633],{},[262,15630,15632],{"href":15631},"\u002Fexamples\u002Fdossiers\u002Fplanelec-pilot-dossier-fr.pdf","dossier d'exemple PlanElec"," contient un schéma unifilaire issu d'un projet fictif, accompagné du plan de situation et des autres documents actuellement disponibles. Il montre la structure de l'export réel sans constituer un dossier utilisable pour une installation ou un contrôle.",[16,15635,15636],{},"Utilisez cet exemple pour comprendre la hiérarchie du document, les références de circuits et la relation avec le plan de situation. Pour votre propre projet, toutes les données doivent correspondre à l'installation réelle et être vérifiées professionnellement.",[23,15638,15640],{"id":15639},"erreurs-courantes-à-éviter","Erreurs courantes à éviter",[367,15642,15644],{"id":15643},"_1-circuits-incomplets","1. Circuits incomplets",[16,15646,15647],{},"Chaque consommateur doit être traçable jusqu'à l'interrupteur principal via une chaîne claire de dispositifs de protection. Ne laissez aucune connexion \"flottante\".",[367,15649,15651],{"id":15650},"_2-mauvaise-utilisation-des-symboles","2. Mauvaise utilisation des symboles",[16,15653,15654],{},"Utilisez les symboles prescrits pour votre application. Les erreurs courantes incluent d'anciens symboles DIN ou des notations personnelles. Le catalogue PlanElec aide à garder une représentation cohérente ; la responsabilité professionnelle reste celle du créateur.",[367,15656,15658],{"id":15657},"_3-informations-manquantes","3. Informations manquantes",[16,15660,15661],{},"Chaque circuit doit indiquer :",[444,15663,15664,15667,15670,15673],{},[447,15665,15666],{},"Numéro de référence du circuit",[447,15668,15669],{},"Type et section du câble (ex. : XVB 3G2,5)",[447,15671,15672],{},"Valeur nominale du dispositif de protection (ex. : 16A ou 20A ; protection standard pour 2,5 mm² : 20 A — 16 A est admissible mais n'est pas l'attribution standard)",[447,15674,15675],{},"Nombre et type de consommateurs",[367,15677,15679],{"id":15678},"_4-schéma-obsolète","4. Schéma obsolète",[16,15681,15682],{},"Si vous avez apporté des modifications à votre installation, le schéma unifilaire doit être mis à jour en conséquence. Un document qui ne correspond plus à l'installation peut entraîner des remarques lors du contrôle.",[23,15684,15686],{"id":15685},"conseils-pour-un-schéma-parfait","Conseils pour un schéma parfait",[444,15688,15689,15695,15701,15707,15713],{},[447,15690,15691,15694],{},[55,15692,15693],{},"Gardez-le propre"," — Évitez les croisements inutiles et les étiquettes qui se chevauchent",[447,15696,15697,15700],{},[55,15698,15699],{},"Soyez cohérent"," — Utilisez le même style de notation dans tout le document",[447,15702,15703,15706],{},[55,15704,15705],{},"Incluez tous les circuits"," — Même les petits ajouts comme une sonnette ou un éclairage de jardin",[447,15708,15709,15712],{},[55,15710,15711],{},"Datez votre document"," — Incluez toujours la date de création\u002Fmodification",[447,15714,15715,15718],{},[55,15716,15717],{},"Ajoutez vos coordonnées"," — Adresse de l'installation et nom du créateur",[23,15720,15722],{"id":15721},"laissez-planelec-faire-le-travail","Laissez PlanElec faire le travail",[16,15724,15725],{},"PlanElec réunit le plan, la topologie électrique et le tableau dans un même projet, puis en déduit le schéma unifilaire.",[444,15727,15728,15731,15734,15737],{},[447,15729,15730],{},"Aucun logiciel CAO nécessaire",[447,15732,15733],{},"Données de projet centralisées sans double saisie",[447,15735,15736],{},"Auto-contrôle RGIE indicatif avec état des règles au 31.03.2025",[447,15738,15739],{},"Export PDF du schéma unifilaire et du plan de situation",[16,15741,15742],{},[262,15743,15744],{"href":1216},"Créez votre schéma unifilaire maintenant — c'est gratuit →",[23,15746,15748],{"id":15747},"pour-aller-plus-loin","Pour aller plus loin",[444,15750,15751,15757,15762,15767],{},[447,15752,15753],{},[262,15754,15756],{"href":15755},"\u002Ffr\u002Fblog\u002Fdessiner-plan-situation-guide","Dessiner un plan de situation selon le RGIE",[447,15758,15759],{},[262,15760,15761],{"href":463},"Planifier un tableau électrique en Belgique",[447,15763,15764],{},[262,15765,15766],{"href":878},"Documenter une borne de recharge dans le schéma unifilaire",[447,15768,15769],{},[262,15770,15772],{"href":15771},"\u002Ffr\u002Fblog\u002Fchecklist-controle","Préparer les documents du contrôle électrique",{"title":487,"searchDepth":488,"depth":488,"links":15774},[15775,15776,15777,15782,15788,15789,15795,15796,15797],{"id":15352,"depth":488,"text":15353},{"id":13172,"depth":488,"text":13173},{"id":15411,"depth":488,"text":15412,"children":15778},[15779,15780,15781],{"id":15418,"depth":497,"text":14521},{"id":15444,"depth":497,"text":15445},{"id":15474,"depth":497,"text":15475},{"id":15497,"depth":488,"text":15498,"children":15783},[15784,15785,15786,15787],{"id":15501,"depth":497,"text":15502},{"id":15533,"depth":497,"text":15534},{"id":15572,"depth":497,"text":15573},{"id":15593,"depth":497,"text":15594},{"id":15625,"depth":488,"text":15626},{"id":15639,"depth":488,"text":15640,"children":15790},[15791,15792,15793,15794],{"id":15643,"depth":497,"text":15644},{"id":15650,"depth":497,"text":15651},{"id":15657,"depth":497,"text":15658},{"id":15678,"depth":497,"text":15679},{"id":15685,"depth":488,"text":15686},{"id":15721,"depth":488,"text":15722},{"id":15747,"depth":488,"text":15748},"tutorial","2026-01-05","Découvrez comment réaliser un schéma unifilaire en Belgique : symboles RGIE, informations obligatoires, exemple PDF et génération avec PlanElec.","2026-08-11",{},"\u002Fblog\u002Fsingle-line-diagram.fr","12 min",{"title":15339,"description":15800},"blog\u002Fsingle-line-diagram.fr",[1240,521,518,13743,13748,13749,11745,11105,2246,13745,2591,13964,519,1241],"kaGMNrR9gi7ZaDEJh_b3OSBFI1q88VXifHFyWNZIahM",{"id":15810,"title":15811,"articleId":15812,"body":15813,"category":16142,"date":16143,"description":16144,"extension":507,"lastUpdated":2234,"locale":508,"meta":16145,"navigation":510,"path":16146,"publishDate":15058,"readTime":1235,"refreshInterval":1567,"seo":16147,"slug":16148,"stem":16149,"tags":16150,"__hash__":16154},"blog\u002Fblog\u002Farei-regulations-2026.fr.md","Réglementation RGIE 2026 : Les Changements Clés","arei-regulations-2026",{"type":9,"value":15814,"toc":16129},[15815,15819,15826,15829,15833,15837,15840,15866,15874,15878,15889,15909,15912,15916,15919,15944,15948,15951,15978,15982,15988,16002,16010,16014,16024,16035,16038,16042,16088,16092,16095,16121,16124],[23,15816,15818],{"id":15817},"aperçu-des-modifications-2026","Aperçu des modifications 2026",[16,15820,15821,15822,15825],{},"Les réglementations électriques belges — connues sous le nom de RGIE (",[258,15823,15824],{},"Règlement Général sur les Installations Électriques","), ou AREI en néerlandais — sont régulièrement mises à jour pour suivre les avancées technologiques et les exigences de sécurité. L'édition 2026 introduit plusieurs changements importants qui affectent aussi bien les nouvelles installations que les rénovations.",[16,15827,15828],{},"Que vous soyez propriétaire planifiant une rénovation, électricien travaillant sur des projets, ou promoteur immobilier, comprendre ces changements est essentiel pour assurer la conformité.",[23,15830,15832],{"id":15831},"les-changements-clés-en-bref","Les changements clés en bref",[367,15834,15836],{"id":15835},"_1-protection-renforcée-pour-les-bornes-de-recharge-ve","1. Protection renforcée pour les bornes de recharge VE",[16,15838,15839],{},"Avec la croissance rapide des véhicules électriques en Belgique, la réglementation 2026 renforce les exigences pour les installations de recharge :",[444,15841,15842,15848,15854,15860],{},[447,15843,15844,15847],{},[55,15845,15846],{},"Circuit dédié obligatoire"," — Chaque point de charge doit avoir son propre circuit avec une protection appropriée",[447,15849,15850,15853],{},[55,15851,15852],{},"Gestion de charge"," — Les installations avec plusieurs points de charge doivent inclure une gestion intelligente de la charge",[447,15855,15856,15859],{},[55,15857,15858],{},"Dimensionnement des câbles"," — Les sections minimales des câbles pour les circuits de recharge ont été augmentées",[447,15861,15862,15865],{},[55,15863,15864],{},"Différentiel Type B"," — Les installations de recharge nécessitent désormais des différentiels de Type B (ou Type A avec détection DC)",[1759,15867,15868],{},[16,15869,15870,15873],{},[55,15871,15872],{},"Impact"," : Si vous installez une borne de recharge VE, prévoyez un circuit dédié avec une protection appropriée. La mise à niveau d'un circuit existant n'est plus acceptable.",[367,15875,15877],{"id":15876},"_2-protection-contre-les-surtensions-principe-et-bonne-pratique","2. Protection contre les surtensions — principe et bonne pratique",[16,15879,15880,15881,15884,15885,15888],{},"En tant que ",[55,15882,15883],{},"principe",", le RGIE (Art. 4.5.1) impose de protéger les personnes et les biens contre les surtensions « selon les règles de l'art », mais il ne prévoit ",[55,15886,15887],{},"aucune obligation explicite d'un dispositif SPD particulier ni de Type 2",". Dans la pratique, les organismes de contrôle attendent toutefois de plus en plus une protection contre les surtensions (SPD — Surge Protection Device) pour les nouvelles installations et les rénovations majeures. La pratique courante peut se résumer ainsi :",[444,15890,15891,15897,15903,15906],{},[447,15892,15893,15896],{},[55,15894,15895],{},"SPD Type 2"," au tableau de distribution principal : courant\u002Frecommandé",[447,15898,15899,15902],{},[55,15900,15901],{},"SPD Type 3"," recommandé pour les équipements sensibles",[447,15904,15905],{},"Devrait être coordonné avec les dispositifs de protection en amont",[447,15907,15908],{},"Contrôle régulier et remplacement après activation recommandés",[16,15910,15911],{},"Ce changement reflète la sensibilité croissante des équipements électroniques modernes et le risque grandissant de surtensions provenant du réseau.",[367,15913,15915],{"id":15914},"_3-exigences-mises-à-jour-pour-les-installations-solaires","3. Exigences mises à jour pour les installations solaires",[16,15917,15918],{},"Les réglementations pour les installations photovoltaïques (PV) ont été affinées :",[444,15920,15921,15926,15932,15938],{},[447,15922,15923,15925],{},[55,15924,5207],{}," doit être accessible et clairement étiqueté",[447,15927,15928,15931],{},[55,15929,15930],{},"Détection d'arc"," (AFDD) est désormais recommandée pour les circuits DC",[447,15933,15934,15937],{},[55,15935,15936],{},"Systèmes de stockage par batteries"," doivent respecter des exigences spécifiques de ventilation et de protection incendie",[447,15939,15940,15943],{},[55,15941,15942],{},"Documentation du comptage bidirectionnel"," doit être incluse dans le dossier d'installation",[367,15945,15947],{"id":15946},"_4-règles-plus-strictes-pour-les-pièces-humides","4. Règles plus strictes pour les pièces humides",[16,15949,15950],{},"La classification des pièces humides (zones) et leurs exigences de protection ont été mises à jour :",[444,15952,15953,15958,15963,15972],{},[447,15954,15955,15957],{},[55,15956,14021],{}," (dans la baignoire\u002Fdouche) — Seuls les circuits TBTS (Très Basse Tension de Sécurité) autorisés",[447,15959,15960,15962],{},[55,15961,14034],{}," (au-dessus de la baignoire\u002Fdouche) — Minimum IPX4 en zone 1 (IPX5 uniquement en cas de jets d'eau\u002Fnettoyage haute pression)",[447,15964,15965,15967,15968,15971],{},[55,15966,14047],{}," (bande de 0,60 m à partir de la limite extérieure de la zone 1 — uniquement pour les baignoires ; pour les douches, la zone 2 n'est pas définie, on passe directement à la zone hors volumes) — prises uniquement avec un différentiel à ",[55,15969,15970],{},"très haute sensibilité (≤ 10 mA)"," ou un transformateur de séparation individuel ≤ 100 W, IP X4 minimum. La protection différentielle 30mA s'applique de toute façon à tous les circuits de la salle de bain (Art. 7.1.4.3).",[447,15973,15974,15977],{},[55,15975,15976],{},"Zone en dehors des zones"," — Règles d'installation normales, équipement résistant aux éclaboussures recommandé",[367,15979,15981],{"id":15980},"_5-documentation-numérique-acceptée","5. Documentation numérique acceptée",[16,15983,15984,15985,583],{},"Pour la première fois, la réglementation accepte explicitement la ",[55,15986,15987],{},"documentation numérique",[444,15989,15990,15993,15996,15999],{},[447,15991,15992],{},"Les schémas unifilaires peuvent être soumis au format PDF numérique",[447,15994,15995],{},"Les plans de situation peuvent être générés avec des outils numériques (comme PlanElec)",[447,15997,15998],{},"Les signatures numériques sont acceptées sur les déclarations de conformité",[447,16000,16001],{},"L'archivage électronique des rapports de contrôle est autorisé",[1759,16003,16004],{},[16,16005,16006,16009],{},[55,16007,16008],{},"Bonne nouvelle"," : Ce changement valide officiellement l'utilisation d'outils comme PlanElec pour la création de votre documentation électrique.",[23,16011,16013],{"id":16012},"ce-que-cela-signifie-pour-les-installations-existantes","Ce que cela signifie pour les installations existantes",[16,16015,16016,16017,16019,16020,16023],{},"La réglementation 2026 s'applique principalement aux ",[55,16018,13435],{}," et aux ",[55,16021,16022],{},"rénovations majeures",". Les installations existantes ayant réussi le contrôle sous les réglementations précédentes restent valides jusqu'à :",[444,16025,16026,16029,16032],{},[447,16027,16028],{},"Le prochain contrôle périodique (tous les 25 ans)",[447,16030,16031],{},"Une modification majeure de l'installation",[447,16033,16034],{},"La vente du bien immobilier",[16,16036,16037],{},"Cependant, il est recommandé de mettre à jour proactivement votre installation pour répondre aux nouvelles normes, en particulier concernant la protection contre les surtensions et les exigences des pièces humides.",[23,16039,16041],{"id":16040},"calendrier-et-mise-en-œuvre","Calendrier et mise en œuvre",[28,16043,16044,16054],{},[31,16045,16046],{},[34,16047,16048,16051],{},[37,16049,16050],{},"Date",[37,16052,16053],{},"Jalon",[47,16055,16056,16064,16072,16080],{},[34,16057,16058,16061],{},[52,16059,16060],{},"Janvier 2026",[52,16062,16063],{},"Nouvelles réglementations publiées",[34,16065,16066,16069],{},[52,16067,16068],{},"Mars 2026",[52,16070,16071],{},"Période de transition commence",[34,16073,16074,16077],{},[52,16075,16076],{},"Juin 2026",[52,16078,16079],{},"Application complète pour les nouvelles installations",[34,16081,16082,16085],{},[52,16083,16084],{},"Décembre 2026",[52,16086,16087],{},"Application complète pour les rénovations majeures",[23,16089,16091],{"id":16090},"comment-planelec-reste-à-jour","Comment PlanElec reste à jour",[16,16093,16094],{},"PlanElec est continuellement mis à jour pour refléter les dernières réglementations RGIE :",[444,16096,16097,16103,16109,16115],{},[447,16098,16099,16102],{},[55,16100,16101],{},"Bibliothèque de symboles"," mise à jour avec les nouveaux symboles de composants",[447,16104,16105,16108],{},[55,16106,16107],{},"Règles de validation"," vérifient la conformité avec les exigences 2026",[447,16110,16111,16114],{},[55,16112,16113],{},"Modèles"," incluent les nouveaux éléments obligatoires (SPD, circuits VE)",[447,16116,16117,16120],{},[55,16118,16119],{},"Export PDF centralisé"," pour le schéma unifilaire et le plan de situation",[16,16122,16123],{},"PlanElec aide à structurer la documentation et signale certaines erreurs prises en charge. L'état interne des règles date toutefois du 31.03.2025 ; les modifications de 2026 sont encore en cours d'intégration. L'outil ne garantit donc pas la conformité et ne remplace pas un contrôle officiel.",[16,16125,16126],{},[262,16127,16128],{"href":1216},"Mettez à jour votre documentation électrique avec PlanElec →",{"title":487,"searchDepth":488,"depth":488,"links":16130},[16131,16132,16139,16140,16141],{"id":15817,"depth":488,"text":15818},{"id":15831,"depth":488,"text":15832,"children":16133},[16134,16135,16136,16137,16138],{"id":15835,"depth":497,"text":15836},{"id":15876,"depth":497,"text":15877},{"id":15914,"depth":497,"text":15915},{"id":15946,"depth":497,"text":15947},{"id":15980,"depth":497,"text":15981},{"id":16012,"depth":488,"text":16013},{"id":16040,"depth":488,"text":16041},{"id":16090,"depth":488,"text":16091},"news","2026-01-02","Les dernières mises à jour des réglementations électriques belges et ce qu'elles signifient pour votre installation.",{},"\u002Fblog\u002Farei-regulations-2026.fr",{"title":15811,"description":16144},"reglementations-rgie-2026","blog\u002Farei-regulations-2026.fr",[1240,521,16151,16152,2246,518,13743,519,13744,16153,1245,1247,1799,1241],"réglementation 2026","réglementations électriques","surtension","mnwWgh_Uqowvm4QqSzeFgslR2pjforpcTlG83to3EsY",1787555171138]