[{"data":1,"prerenderedAt":1290},["ShallowReactive",2],{"blog-post-fr-cable-xvb-vs-vob":3,"blog-alternates-xvb-vs-vob-cable":309},{"id":4,"title":5,"articleId":6,"body":7,"category":288,"date":289,"description":290,"extension":291,"lastUpdated":292,"locale":293,"meta":294,"navigation":295,"path":296,"publishDate":289,"readTime":297,"refreshInterval":298,"seo":299,"slug":300,"stem":301,"tags":302,"__hash__":308},"blog\u002Fblog\u002Fxvb-vs-vob-cable.fr.md","Câble XVB vs. VOB : Lequel choisir pour votre installation ?","xvb-vs-vob-cable",{"type":8,"value":9,"toc":278},"minimark",[10,15,23,28,31,35,42,46,160,164,206,210,221,242,263,267],[11,12,14],"h1",{"id":13},"câble-xvb-vs-vob-lequel-choisir","Câble XVB vs. VOB : Lequel choisir ?",[16,17,18,22],"p",{},[19,20,21],"strong",{},"Le XVB est le câble sous gaine standard pour les installations fixes dans les nouvelles constructions en Belgique."," Il contient plusieurs conducteurs avec une gaine extérieure et peut être posé directement dans les murs, les sols ou les conduits. Le VOB, en revanche, est un fil individuel qui doit toujours être placé dans un tube de protection ou une goulotte.",[24,25,27],"h2",{"id":26},"quest-ce-que-le-xvb","Qu'est-ce que le XVB ?",[16,29,30],{},"Le XVB (p.ex. XVB 3G2,5) est un câble multiconducteur avec isolation PVC et gaine extérieure PVC. La désignation indique le nombre de conducteurs et la section. Le XVB est conçu pour une pose fixe — dans des saignées murales, sous enduit, dans des conduits ou sur des chemins de câbles.",[24,32,34],{"id":33},"quest-ce-que-le-vob","Qu'est-ce que le VOB ?",[16,36,37,38,41],{},"Le VOB (p.ex. VOB 2,5mm²) est un fil souple individuel avec isolation PVC. Il ne peut ",[19,39,40],{},"jamais être posé librement"," et doit toujours être installé dans un tube de protection (conduit) ou une goulotte. Le VOB est moins cher au mètre, mais nécessite le coût supplémentaire du tube de protection.",[24,43,45],{"id":44},"tableau-comparatif","Tableau comparatif",[47,48,49,65],"table",{},[50,51,52],"thead",{},[53,54,55,59,62],"tr",{},[56,57,58],"th",{},"Caractéristique",[56,60,61],{},"XVB",[56,63,64],{},"VOB",[66,67,68,82,95,108,121,134,147],"tbody",{},[53,69,70,76,79],{},[71,72,73],"td",{},[19,74,75],{},"Construction",[71,77,78],{},"Multiconducteur avec gaine",[71,80,81],{},"Fil individuel sans gaine",[53,83,84,89,92],{},[71,85,86],{},[19,87,88],{},"Pose",[71,90,91],{},"Directe dans mur, sol, conduit",[71,93,94],{},"Uniquement dans conduit\u002Fgoulotte",[53,96,97,102,105],{},[71,98,99],{},[19,100,101],{},"Tube requis ?",[71,103,104],{},"Non (optionnel)",[71,106,107],{},"Oui, toujours",[53,109,110,115,118],{},[71,111,112],{},[19,113,114],{},"Prix au mètre",[71,116,117],{},"Plus élevé (~1,50–3,00 €\u002Fm pour 3G2,5)",[71,119,120],{},"Plus bas (~0,30–0,50 €\u002Fm par conducteur)",[53,122,123,128,131],{},[71,124,125],{},[19,126,127],{},"Coût total",[71,129,130],{},"Souvent moins cher (pas de tube)",[71,132,133],{},"Tube + main-d'œuvre = plus cher",[53,135,136,141,144],{},[71,137,138],{},[19,139,140],{},"Flexibilité",[71,142,143],{},"Plus rigide, difficile à courber",[71,145,146],{},"Plus flexible dans le tube",[53,148,149,154,157],{},[71,150,151],{},[19,152,153],{},"Application typique",[71,155,156],{},"Neuf, rénovation",[71,158,159],{},"Rénovation dans conduits existants",[24,161,163],{"id":162},"exigences-rgie","Exigences RGIE",[47,165,166,176],{},[50,167,168],{},[53,169,170,173],{},[56,171,172],{},"Article RGIE",[56,174,175],{},"Exigence",[66,177,178,186],{},[53,179,180,183],{},[71,181,182],{},"Art. 5.2.2",[71,184,185],{},"Les câbles doivent être adaptés au mode de pose ; les fils individuels (VOB) uniquement dans des tubes ou goulottes d'installation électrique",[53,187,188,191],{},[71,189,190],{},"Art. 5.2.7.2 \u002F 5.2.7.3",[71,192,193,194,197,198,201,202,205],{},"Classe de réaction au feu CPR : câbles posés individuellement au minimum ",[19,195,196],{},"Eca"," (art. 5.2.7.2). En ",[19,199,200],{},"faisceaux, cloisons creuses et cavités constructives"," au minimum ",[19,203,204],{},"Cca"," (art. 5.2.7.3, art. 4.3.3.5b)",[24,207,209],{"id":208},"recommandation","Recommandation",[16,211,212,213,216,217,220],{},"Pour les ",[19,214,215],{},"nouvelles installations",", le XVB est le premier choix : moins d'étapes de travail, pas de tubes de protection nécessaires et conforme au RGIE. Le VOB convient surtout aux ",[19,218,219],{},"rénovations"," où des conduits existent déjà et où des fils individuels doivent être tirés.",[16,222,223,224,226,227,229,230,233,234,237,238,241],{},"Pour les deux types de câbles, veillez à la classe de réaction au feu CPR prescrite — en faisceaux, cloisons creuses et cavités constructives au minimum ",[19,225,204],{}," (art. 5.2.7.3), et pour les câbles posés individuellement dans les murs massifs sous enduit ",[19,228,196],{}," suffit (art. 5.2.7.2). La classification complémentaire à faible émission de fumée et faible acidité (",[19,231,232],{},"s1","\u002F",[19,235,236],{},"a1",") est imposée par l'art. 4.3.3.7 a pour les lieux du tableau 4.10 : voies d'évacuation dans les bâtiments, locaux accessibles au public pouvant recevoir au moins 50 personnes et tunnels. À l'intérieur du logement, elle ne s'applique pas — le tableau 4.10 exclut expressément les installations domestiques. Attention toutefois en immeuble à appartements : les parties communes et locaux techniques d'un immeuble d'habitation ne sont ",[19,239,240],{},"pas"," des installations domestiques selon la partie 2 du RGIE, l'exigence vaut donc bien dans la cage d'escalier. Les câbles plus anciens sans classification CPR ne peuvent plus être utilisés dans les nouvelles installations.",[243,244,245],"blockquote",{},[16,246,247,250,251,254,255,258,259,262],{},[19,248,249],{},"Code couleur (art. 5.1.6.2) :"," Le ",[19,252,253],{},"vert-jaune"," est réservé au conducteur de protection (PE\u002FPEN), le ",[19,256,257],{},"bleu"," au conducteur neutre (N) — ces deux couleurs sont interdites pour les conducteurs actifs (phases). Pour les conducteurs de phase (L1\u002FL2\u002FL3), on utilise donc habituellement le ",[19,260,261],{},"brun\u002Fnoir\u002Fgris",".",[24,264,266],{"id":265},"articles-connexes","Articles connexes",[16,268,269,270,277],{},"Planifiez votre installation électrique avec ",[271,272,276],"a",{"href":273,"rel":274},"https:\u002F\u002Fwww.planelec.be",[275],"nofollow","PlanElec",". L'auto-contrôle peut signaler certaines combinaisons de câble et de protection prises en charge, mais ne remplace pas un calcul professionnel.",{"title":279,"searchDepth":280,"depth":280,"links":281},"",2,[282,283,284,285,286,287],{"id":26,"depth":280,"text":27},{"id":33,"depth":280,"text":34},{"id":44,"depth":280,"text":45},{"id":162,"depth":280,"text":163},{"id":208,"depth":280,"text":209},{"id":265,"depth":280,"text":266},"faq","2026-03-16","Comparaison entre le câble sous gaine XVB et le fil VOB pour les installations électriques belges selon le RGIE.","md","2026-08-18","fr",{},true,"\u002Fblog\u002Fxvb-vs-vob-cable.fr","4 min",12,{"title":5,"description":290},"cable-xvb-vs-vob","blog\u002Fxvb-vs-vob-cable.fr",[303,304,305,306,307],"câble","xvb","vob","installation","rgie","ymobiuj7tzERW5y_4_XnGP97htqbyzdrfAcPhkICmaU",[310,578,841,1028],{"id":311,"title":312,"articleId":6,"body":313,"category":288,"date":289,"description":567,"extension":291,"lastUpdated":292,"locale":568,"meta":569,"navigation":295,"path":570,"publishDate":289,"readTime":297,"refreshInterval":298,"seo":571,"slug":572,"stem":573,"tags":574,"__hash__":577},"blog\u002Fblog\u002Fxvb-vs-vob-cable.de.md","XVB vs. VOB Kabel: Welches ist das richtige für Ihre Installation?",{"type":8,"value":314,"toc":559},[315,319,325,329,332,336,343,347,453,457,495,499,510,528,548,552],[11,316,318],{"id":317},"xvb-vs-vob-kabel-welches-ist-das-richtige","XVB vs. VOB Kabel: Welches ist das richtige?",[16,320,321,324],{},[19,322,323],{},"XVB ist die Standard-Mantelleitung für feste Verlegung in belgischen Neuinstallationen."," Sie enthält mehrere Adern mit Außenmantel und kann direkt in Wänden, Böden oder Leerrohren verlegt werden. VOB hingegen ist eine Einzelader, die immer in einem Schutzrohr oder Kabelkanal geführt werden muss.",[24,326,328],{"id":327},"was-ist-xvb","Was ist XVB?",[16,330,331],{},"XVB (z. B. XVB 3G2,5) ist eine mehradrige Mantelleitung mit PVC-Isolierung und PVC-Außenmantel. Die Bezeichnung gibt die Aderzahl und den Querschnitt an. XVB ist für die feste Verlegung konzipiert — in Mauerschlitzen, unter Putz, in Leerrohren oder auf Kabelpritschen.",[24,333,335],{"id":334},"was-ist-vob","Was ist VOB?",[16,337,338,339,342],{},"VOB (z. B. VOB 2,5mm²) ist eine flexible Einzelader mit PVC-Isolierung. Sie darf ",[19,340,341],{},"niemals frei verlegt"," werden, sondern muss immer in einem Schutzrohr (Leerrohr) oder Kabelkanal installiert werden. VOB ist günstiger pro Meter, erfordert aber den zusätzlichen Aufwand des Schutzrohrs.",[24,344,346],{"id":345},"vergleichstabelle","Vergleichstabelle",[47,348,349,360],{},[50,350,351],{},[53,352,353,356,358],{},[56,354,355],{},"Eigenschaft",[56,357,61],{},[56,359,64],{},[66,361,362,375,388,401,414,427,440],{},[53,363,364,369,372],{},[71,365,366],{},[19,367,368],{},"Aufbau",[71,370,371],{},"Mehradrig mit Außenmantel",[71,373,374],{},"Einzelader ohne Mantel",[53,376,377,382,385],{},[71,378,379],{},[19,380,381],{},"Verlegung",[71,383,384],{},"Direkt in Wand, Boden, Leerrohr",[71,386,387],{},"Nur in Leerrohr\u002FKabelkanal",[53,389,390,395,398],{},[71,391,392],{},[19,393,394],{},"Schutzrohr nötig?",[71,396,397],{},"Nein (optional)",[71,399,400],{},"Ja, immer",[53,402,403,408,411],{},[71,404,405],{},[19,406,407],{},"Preis pro Meter",[71,409,410],{},"Höher (~€1,50–3,00\u002Fm für 3G2,5)",[71,412,413],{},"Niedriger (~€0,30–0,50\u002Fm pro Ader)",[53,415,416,421,424],{},[71,417,418],{},[19,419,420],{},"Gesamtkosten",[71,422,423],{},"Oft günstiger (kein Rohr nötig)",[71,425,426],{},"Rohr + Arbeitszeit = teurer",[53,428,429,434,437],{},[71,430,431],{},[19,432,433],{},"Flexibilität",[71,435,436],{},"Steifer, schwerer zu biegen",[71,438,439],{},"Flexibler im Rohr",[53,441,442,447,450],{},[71,443,444],{},[19,445,446],{},"Typische Anwendung",[71,448,449],{},"Neuinstallation, Renovierung",[71,451,452],{},"Renovierung in bestehendem Leerrohr",[24,454,456],{"id":455},"arei-anforderungen","AREI-Anforderungen",[47,458,459,469],{},[50,460,461],{},[53,462,463,466],{},[56,464,465],{},"AREI Artikel",[56,467,468],{},"Anforderung",[66,470,471,478],{},[53,472,473,475],{},[71,474,182],{},[71,476,477],{},"Kabel müssen für die Verlegeart geeignet sein; Einzeladern (VOB) nur in Elektroinstallationsrohren oder Kabelkanälen",[53,479,480,482],{},[71,481,190],{},[71,483,484,485,487,488,491,492,494],{},"CPR-Brandklasse: Einzeln verlegte Kabel mind. ",[19,486,196],{}," (Art. 5.2.7.2). In ",[19,489,490],{},"Bündeln, Hohlwänden und baulichen Hohlräumen"," mind. ",[19,493,204],{}," (Art. 5.2.7.3, Art. 4.3.3.5b)",[24,496,498],{"id":497},"empfehlung","Empfehlung",[16,500,501,502,505,506,509],{},"Für ",[19,503,504],{},"Neuinstallationen"," ist XVB die erste Wahl: weniger Arbeitsschritte, keine Schutzrohre nötig und AREI-konform. VOB eignet sich vor allem für ",[19,507,508],{},"Renovierungen",", bei denen bereits Leerrohre vorhanden sind und einzelne Adern nachgezogen werden.",[16,511,512,513,515,516,518,519,233,521,523,524,527],{},"Achten Sie bei beiden Kabeltypen auf die vorgeschriebene CPR-Brandklasse — in Bündeln, Hohlwänden und baulichen Hohlräumen mind. ",[19,514,204],{}," (Art. 5.2.7.3), bei einzelner Verlegung in Massivwänden unter Putz reicht ",[19,517,196],{}," (Art. 5.2.7.2). Die zusätzliche rauch- und säurearme Klassifizierung (",[19,520,232],{},[19,522,236],{},") verlangt Art. 4.3.3.7 a für die Orte aus Tabelle 4.10: Fluchtwege in Bauwerken, der Öffentlichkeit zugängliche Räume ab 50 Personen und Tunnel. Innerhalb der Wohnung greift sie nicht — Tabelle 4.10 nimmt hauswirtschaftliche Anlagen ausdrücklich aus. Im Mehrfamilienhaus ist aber Vorsicht geboten: Gemeinschaftliche Teile und Technikräume einer Wohnanlage gelten nach AREI Teil 2 ",[19,525,526],{},"nicht"," als hauswirtschaftliche Anlage, im Treppenhaus ist die Anforderung also sehr wohl einschlägig. Ältere Kabel ohne CPR-Klassifizierung dürfen in Neuinstallationen nicht mehr verwendet werden.",[243,529,530],{},[16,531,532,535,536,539,540,543,544,547],{},[19,533,534],{},"Farbkodierung (Art. 5.1.6.2):"," ",[19,537,538],{},"Grün-Gelb"," ist dem Schutzleiter (PE\u002FPEN) vorbehalten, ",[19,541,542],{},"Blau"," dem Neutralleiter (N) — beide Farben sind für aktive Leiter (Phasen) verboten. Für die Phasenleiter (L1\u002FL2\u002FL3) sind daher üblicherweise ",[19,545,546],{},"Braun\u002FSchwarz\u002FGrau"," in Gebrauch.",[24,549,551],{"id":550},"verwandte-artikel","Verwandte Artikel",[16,553,554,555,558],{},"Planen Sie Ihre Elektroinstallation mit ",[271,556,276],{"href":273,"rel":557},[275],". Der Selbstcheck kann unterstützte Kombinationen von Kabel und Schutzgerät markieren, ersetzt aber keine fachliche Berechnung.",{"title":279,"searchDepth":280,"depth":280,"links":560},[561,562,563,564,565,566],{"id":327,"depth":280,"text":328},{"id":334,"depth":280,"text":335},{"id":345,"depth":280,"text":346},{"id":455,"depth":280,"text":456},{"id":497,"depth":280,"text":498},{"id":550,"depth":280,"text":551},"Vergleich zwischen XVB-Mantelleitung und VOB-Einzelader für belgische Elektroinstallationen nach AREI-Normen.","de",{},"\u002Fblog\u002Fxvb-vs-vob-cable.de",{"title":312,"description":567},"xvb-vs-vob-kabel","blog\u002Fxvb-vs-vob-cable.de",[575,304,305,306,576],"kabel","arei","vTBm8ncHUlTtyCYxYILA5LzOOv5b_l82CbxyWWYbXSs",{"id":579,"title":580,"articleId":6,"body":581,"category":288,"date":289,"description":832,"extension":291,"lastUpdated":292,"locale":833,"meta":834,"navigation":295,"path":835,"publishDate":289,"readTime":297,"refreshInterval":298,"seo":836,"slug":6,"stem":837,"tags":838,"__hash__":840},"blog\u002Fblog\u002Fxvb-vs-vob-cable.en.md","XVB vs. VOB Cable: Which Is Right for Your Installation?",{"type":8,"value":582,"toc":824},[583,587,593,597,600,604,611,615,720,724,761,765,776,794,813,817],[11,584,586],{"id":585},"xvb-vs-vob-cable-which-is-right","XVB vs. VOB Cable: Which Is Right?",[16,588,589,592],{},[19,590,591],{},"XVB is the standard sheathed cable for fixed wiring in Belgian new installations."," It contains multiple conductors with an outer sheath and can be installed directly in walls, floors, or conduits. VOB, on the other hand, is a single-core wire that must always be placed inside a protective conduit or cable trunking.",[24,594,596],{"id":595},"what-is-xvb","What Is XVB?",[16,598,599],{},"XVB (e.g., XVB 3G2.5) is a multi-core sheathed cable with PVC insulation and PVC outer sheath. The designation indicates the number of cores and cross-section. XVB is designed for fixed installation — in wall chases, under plaster, in conduits, or on cable trays.",[24,601,603],{"id":602},"what-is-vob","What Is VOB?",[16,605,606,607,610],{},"VOB (e.g., VOB 2.5mm²) is a flexible single-core wire with PVC insulation. It must ",[19,608,609],{},"never be installed freely"," and always requires a protective conduit (tube) or cable trunking. VOB is cheaper per meter but requires the additional cost of protective tubing.",[24,612,614],{"id":613},"comparison-table","Comparison Table",[47,616,617,628],{},[50,618,619],{},[53,620,621,624,626],{},[56,622,623],{},"Property",[56,625,61],{},[56,627,64],{},[66,629,630,642,655,668,681,694,707],{},[53,631,632,636,639],{},[71,633,634],{},[19,635,75],{},[71,637,638],{},"Multi-core with outer sheath",[71,640,641],{},"Single core without sheath",[53,643,644,649,652],{},[71,645,646],{},[19,647,648],{},"Installation",[71,650,651],{},"Directly in wall, floor, conduit",[71,653,654],{},"Only in conduit\u002Ftrunking",[53,656,657,662,665],{},[71,658,659],{},[19,660,661],{},"Conduit required?",[71,663,664],{},"No (optional)",[71,666,667],{},"Yes, always",[53,669,670,675,678],{},[71,671,672],{},[19,673,674],{},"Price per meter",[71,676,677],{},"Higher (~€1.50–3.00\u002Fm for 3G2.5)",[71,679,680],{},"Lower (~€0.30–0.50\u002Fm per core)",[53,682,683,688,691],{},[71,684,685],{},[19,686,687],{},"Total cost",[71,689,690],{},"Often cheaper (no conduit needed)",[71,692,693],{},"Conduit + labour = more expensive",[53,695,696,701,704],{},[71,697,698],{},[19,699,700],{},"Flexibility",[71,702,703],{},"Stiffer, harder to bend",[71,705,706],{},"More flexible inside conduit",[53,708,709,714,717],{},[71,710,711],{},[19,712,713],{},"Typical use",[71,715,716],{},"New construction, renovation",[71,718,719],{},"Renovation in existing conduits",[24,721,723],{"id":722},"areirgie-requirements","AREI\u002FRGIE Requirements",[47,725,726,736],{},[50,727,728],{},[53,729,730,733],{},[56,731,732],{},"AREI Article",[56,734,735],{},"Requirement",[66,737,738,745],{},[53,739,740,742],{},[71,741,182],{},[71,743,744],{},"Cables must be suitable for the installation method; single-core wires (VOB) only in electrical conduits or cable trunking",[53,746,747,749],{},[71,748,190],{},[71,750,751,752,487,754,757,758,760],{},"CPR fire class: individually installed cables require at least ",[19,753,196],{},[19,755,756],{},"bundles, hollow walls, and building cavities",", at least ",[19,759,204],{}," is required (Art. 5.2.7.3, Art. 4.3.3.5b)",[24,762,764],{"id":763},"recommendation","Recommendation",[16,766,767,768,771,772,775],{},"For ",[19,769,770],{},"new installations",", XVB is the first choice: fewer work steps, no protective conduits needed, and AREI-compliant. VOB is mainly suitable for ",[19,773,774],{},"renovations"," where conduits already exist and individual wires need to be pulled through.",[16,777,778,779,781,782,784,785,233,787,789,790,793],{},"For both cable types, ensure compliance with the required CPR fire class — in bundles, hollow walls, and building cavities at least ",[19,780,204],{}," (Art. 5.2.7.3), and for individually installed cables in solid walls under plaster ",[19,783,196],{}," is sufficient (Art. 5.2.7.2). The additional low-smoke, low-acid classification (",[19,786,232],{},[19,788,236],{},") is required by Art. 4.3.3.7 a for the locations listed in Table 4.10: escape routes in buildings, publicly accessible spaces holding at least 50 people, and tunnels. Inside the dwelling it does not apply — Table 4.10 explicitly exempts domestic installations. In an apartment building, however, take care: the common parts and technical rooms of a residential building are ",[19,791,792],{},"not"," domestic installations under AREI Part 2, so the requirement does apply in the stairwell. Older cables without CPR classification may no longer be used in new installations.",[243,795,796],{},[16,797,798,535,801,804,805,808,809,812],{},[19,799,800],{},"Colour coding (Art. 5.1.6.2):",[19,802,803],{},"Green-Yellow"," is reserved for the protective conductor (PE\u002FPEN), ",[19,806,807],{},"Blue"," for the neutral conductor (N) — both colours are prohibited for active (phase) conductors. For the phase conductors (L1\u002FL2\u002FL3), ",[19,810,811],{},"Brown\u002FBlack\u002FGrey"," are therefore commonly used.",[24,814,816],{"id":815},"related-articles","Related Articles",[16,818,819,820,823],{},"Plan your electrical installation with ",[271,821,276],{"href":273,"rel":822},[275],". The self-check can flag supported cable and protection combinations but does not replace professional engineering.",{"title":279,"searchDepth":280,"depth":280,"links":825},[826,827,828,829,830,831],{"id":595,"depth":280,"text":596},{"id":602,"depth":280,"text":603},{"id":613,"depth":280,"text":614},{"id":722,"depth":280,"text":723},{"id":763,"depth":280,"text":764},{"id":815,"depth":280,"text":816},"Comparison between XVB sheathed cable and VOB single-core wire for Belgian electrical installations according to AREI\u002FRGIE standards.","en",{},"\u002Fblog\u002Fxvb-vs-vob-cable.en",{"title":580,"description":832},"blog\u002Fxvb-vs-vob-cable.en",[839,304,305,306,576],"cable","TxnkWoJQZlGtAflPfGpMlnlgKWDqemScZVMWlhN3J1U",{"id":4,"title":5,"articleId":6,"body":842,"category":288,"date":289,"description":290,"extension":291,"lastUpdated":292,"locale":293,"meta":1025,"navigation":295,"path":296,"publishDate":289,"readTime":297,"refreshInterval":298,"seo":1026,"slug":300,"stem":301,"tags":1027,"__hash__":308},{"type":8,"value":843,"toc":1017},[844,846,850,852,854,856,860,862,946,948,978,980,986,998,1010,1012],[11,845,14],{"id":13},[16,847,848,22],{},[19,849,21],{},[24,851,27],{"id":26},[16,853,30],{},[24,855,34],{"id":33},[16,857,37,858,41],{},[19,859,40],{},[24,861,45],{"id":44},[47,863,864,874],{},[50,865,866],{},[53,867,868,870,872],{},[56,869,58],{},[56,871,61],{},[56,873,64],{},[66,875,876,886,896,906,916,926,936],{},[53,877,878,882,884],{},[71,879,880],{},[19,881,75],{},[71,883,78],{},[71,885,81],{},[53,887,888,892,894],{},[71,889,890],{},[19,891,88],{},[71,893,91],{},[71,895,94],{},[53,897,898,902,904],{},[71,899,900],{},[19,901,101],{},[71,903,104],{},[71,905,107],{},[53,907,908,912,914],{},[71,909,910],{},[19,911,114],{},[71,913,117],{},[71,915,120],{},[53,917,918,922,924],{},[71,919,920],{},[19,921,127],{},[71,923,130],{},[71,925,133],{},[53,927,928,932,934],{},[71,929,930],{},[19,931,140],{},[71,933,143],{},[71,935,146],{},[53,937,938,942,944],{},[71,939,940],{},[19,941,153],{},[71,943,156],{},[71,945,159],{},[24,947,163],{"id":162},[47,949,950,958],{},[50,951,952],{},[53,953,954,956],{},[56,955,172],{},[56,957,175],{},[66,959,960,966],{},[53,961,962,964],{},[71,963,182],{},[71,965,185],{},[53,967,968,970],{},[71,969,190],{},[71,971,193,972,197,974,201,976,205],{},[19,973,196],{},[19,975,200],{},[19,977,204],{},[24,979,209],{"id":208},[16,981,212,982,216,984,220],{},[19,983,215],{},[19,985,219],{},[16,987,223,988,226,990,229,992,233,994,237,996,241],{},[19,989,204],{},[19,991,196],{},[19,993,232],{},[19,995,236],{},[19,997,240],{},[243,999,1000],{},[16,1001,1002,250,1004,254,1006,258,1008,262],{},[19,1003,249],{},[19,1005,253],{},[19,1007,257],{},[19,1009,261],{},[24,1011,266],{"id":265},[16,1013,269,1014,277],{},[271,1015,276],{"href":273,"rel":1016},[275],{"title":279,"searchDepth":280,"depth":280,"links":1018},[1019,1020,1021,1022,1023,1024],{"id":26,"depth":280,"text":27},{"id":33,"depth":280,"text":34},{"id":44,"depth":280,"text":45},{"id":162,"depth":280,"text":163},{"id":208,"depth":280,"text":209},{"id":265,"depth":280,"text":266},{},{"title":5,"description":290},[303,304,305,306,307],{"id":1029,"title":1030,"articleId":6,"body":1031,"category":288,"date":289,"description":1281,"extension":291,"lastUpdated":292,"locale":1282,"meta":1283,"navigation":295,"path":1284,"publishDate":289,"readTime":297,"refreshInterval":298,"seo":1285,"slug":572,"stem":1286,"tags":1287,"__hash__":1289},"blog\u002Fblog\u002Fxvb-vs-vob-cable.nl.md","XVB vs. VOB kabel: Welke is de juiste voor uw installatie?",{"type":8,"value":1032,"toc":1273},[1033,1037,1043,1047,1050,1054,1061,1065,1171,1175,1210,1214,1225,1243,1262,1266],[11,1034,1036],{"id":1035},"xvb-vs-vob-kabel-welke-is-de-juiste","XVB vs. VOB kabel: Welke is de juiste?",[16,1038,1039,1042],{},[19,1040,1041],{},"XVB is de standaard mantelkabel voor vaste bekabeling in Belgische nieuwbouwinstallaties."," De kabel bevat meerdere aders met een buitenmantel en kan rechtstreeks in muren, vloeren of leidingbuizen worden gelegd. VOB daarentegen is een enkeldraad die altijd in een beschermbuis of kabelgoot moet worden geplaatst.",[24,1044,1046],{"id":1045},"wat-is-xvb","Wat is XVB?",[16,1048,1049],{},"XVB (bv. XVB 3G2,5) is een meeraderige mantelkabel met PVC-isolatie en PVC-buitenmantel. De benaming geeft het aantal aders en de doorsnede aan. XVB is ontworpen voor vaste plaatsing — in muursleuven, onder bepleistering, in leidingbuizen of op kabelbanen.",[24,1051,1053],{"id":1052},"wat-is-vob","Wat is VOB?",[16,1055,1056,1057,1060],{},"VOB (bv. VOB 2,5mm²) is een flexibele enkeldraad met PVC-isolatie. Deze mag ",[19,1058,1059],{},"nooit vrij verlegd"," worden en moet altijd in een beschermbuis (leidingbuis) of kabelgoot worden geïnstalleerd. VOB is goedkoper per meter, maar vereist de bijkomende kost van de beschermbuis.",[24,1062,1064],{"id":1063},"vergelijkingstabel","Vergelijkingstabel",[47,1066,1067,1078],{},[50,1068,1069],{},[53,1070,1071,1074,1076],{},[56,1072,1073],{},"Eigenschap",[56,1075,61],{},[56,1077,64],{},[66,1079,1080,1093,1106,1119,1132,1145,1158],{},[53,1081,1082,1087,1090],{},[71,1083,1084],{},[19,1085,1086],{},"Opbouw",[71,1088,1089],{},"Meeraderig met buitenmantel",[71,1091,1092],{},"Enkeldraad zonder mantel",[53,1094,1095,1100,1103],{},[71,1096,1097],{},[19,1098,1099],{},"Plaatsing",[71,1101,1102],{},"Rechtstreeks in muur, vloer, buis",[71,1104,1105],{},"Enkel in buis\u002Fkabelgoot",[53,1107,1108,1113,1116],{},[71,1109,1110],{},[19,1111,1112],{},"Beschermbuis nodig?",[71,1114,1115],{},"Nee (optioneel)",[71,1117,1118],{},"Ja, altijd",[53,1120,1121,1126,1129],{},[71,1122,1123],{},[19,1124,1125],{},"Prijs per meter",[71,1127,1128],{},"Hoger (~€1,50–3,00\u002Fm voor 3G2,5)",[71,1130,1131],{},"Lager (~€0,30–0,50\u002Fm per ader)",[53,1133,1134,1139,1142],{},[71,1135,1136],{},[19,1137,1138],{},"Totale kosten",[71,1140,1141],{},"Vaak goedkoper (geen buis nodig)",[71,1143,1144],{},"Buis + arbeid = duurder",[53,1146,1147,1152,1155],{},[71,1148,1149],{},[19,1150,1151],{},"Flexibiliteit",[71,1153,1154],{},"Stijver, moeilijker te buigen",[71,1156,1157],{},"Flexibeler in buis",[53,1159,1160,1165,1168],{},[71,1161,1162],{},[19,1163,1164],{},"Typische toepassing",[71,1166,1167],{},"Nieuwbouw, renovatie",[71,1169,1170],{},"Renovatie in bestaande leidingbuizen",[24,1172,1174],{"id":1173},"arei-vereisten","AREI-vereisten",[47,1176,1177,1186],{},[50,1178,1179],{},[53,1180,1181,1183],{},[56,1182,465],{},[56,1184,1185],{},"Vereiste",[66,1187,1188,1195],{},[53,1189,1190,1192],{},[71,1191,182],{},[71,1193,1194],{},"Kabels moeten geschikt zijn voor de wijze van aanleg; enkeldraadkabels (VOB) enkel in elektro-installatibuizen of kabelgoten",[53,1196,1197,1199],{},[71,1198,190],{},[71,1200,1201,1202,487,1204,1207,1208,494],{},"CPR-brandklasse: Afzonderlijk geplaatste kabels minstens ",[19,1203,196],{},[19,1205,1206],{},"bundels, holle wanden en bouwkundige holle ruimtes"," minstens ",[19,1209,204],{},[24,1211,1213],{"id":1212},"aanbeveling","Aanbeveling",[16,1215,1216,1217,1220,1221,1224],{},"Voor ",[19,1218,1219],{},"nieuwbouwinstallaties"," is XVB de eerste keuze: minder werkstappen, geen beschermbuizen nodig en AREI-conform. VOB is vooral geschikt voor ",[19,1222,1223],{},"renovaties"," waarbij reeds leidingbuizen aanwezig zijn en individuele draden moeten worden bijgetrokken.",[16,1226,1227,1228,1230,1231,1233,1234,233,1236,1238,1239,1242],{},"Let bij beide kabeltypes op de voorgeschreven CPR-brandklasse — in bundels, holle wanden en bouwkundige holle ruimtes minstens ",[19,1229,204],{}," (Art. 5.2.7.3), en voor afzonderlijk geplaatste kabels in massieve wanden onder bepleistering volstaat ",[19,1232,196],{}," (Art. 5.2.7.2). De bijkomende rookarme en zuurarme classificatie (",[19,1235,232],{},[19,1237,236],{},") eist art. 4.3.3.7 a voor de plaatsen uit tabel 4.10: vluchtwegen in bouwwerken, voor het publiek toegankelijke ruimtes vanaf 50 personen en tunnels. Binnen de woning geldt ze niet — tabel 4.10 sluit huishoudelijke installaties uitdrukkelijk uit. Let wel op bij een meergezinswoning: gemeenschappelijke delen en technische lokalen van een woongebouw zijn volgens AREI deel 2 ",[19,1240,1241],{},"geen"," huishoudelijke installatie, in het trappenhuis is de eis dus wél van toepassing. Oudere kabels zonder CPR-classificatie mogen in nieuwe installaties niet meer worden gebruikt.",[243,1244,1245],{},[16,1246,1247,535,1250,1253,1254,1257,1258,1261],{},[19,1248,1249],{},"Kleurcodering (Art. 5.1.6.2):",[19,1251,1252],{},"Groen-Geel"," is voorbehouden aan de beschermingsleider (PE\u002FPEN), ",[19,1255,1256],{},"Blauw"," aan de nulgeleider (N) — beide kleuren zijn verboden voor actieve geleiders (fasen). Voor de fasegeleiders (L1\u002FL2\u002FL3) worden daarom gewoonlijk ",[19,1259,1260],{},"Bruin\u002FZwart\u002FGrijs"," gebruikt.",[24,1263,1265],{"id":1264},"gerelateerde-artikelen","Gerelateerde artikelen",[16,1267,1268,1269,1272],{},"Plan uw elektro-installatie met ",[271,1270,276],{"href":273,"rel":1271},[275],". De zelfcontrole kan ondersteunde combinaties van kabel en beveiliging signaleren, maar vervangt geen professionele berekening.",{"title":279,"searchDepth":280,"depth":280,"links":1274},[1275,1276,1277,1278,1279,1280],{"id":1045,"depth":280,"text":1046},{"id":1052,"depth":280,"text":1053},{"id":1063,"depth":280,"text":1064},{"id":1173,"depth":280,"text":1174},{"id":1212,"depth":280,"text":1213},{"id":1264,"depth":280,"text":1265},"Vergelijking tussen XVB-mantelkabel en VOB-enkeldraad voor Belgische elektro-installaties volgens het AREI.","nl",{},"\u002Fblog\u002Fxvb-vs-vob-cable.nl",{"title":1030,"description":1281},"blog\u002Fxvb-vs-vob-cable.nl",[575,304,305,1288,576],"installatie","O_E3yVObn-I1EDHtaBF0gvUVwbMa2-cnnxZ5N-HUZCg",1787555259038]