[{"data":1,"prerenderedAt":1237},["ShallowReactive",2],{"blog-post-fr-plan-de-situation":3,"blog-alternates-what-is-a-situation-plan":292},{"id":4,"title":5,"articleId":6,"body":7,"category":266,"date":267,"description":268,"extension":269,"lastUpdated":270,"locale":271,"meta":272,"navigation":273,"path":274,"publishDate":267,"readTime":275,"refreshInterval":276,"seo":277,"slug":278,"stem":279,"tags":280,"__hash__":291},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.fr.md","Qu'est-ce qu'un plan de situation ?","what-is-a-situation-plan",{"type":8,"value":9,"toc":254},"minimark",[10,15,33,40,44,51,100,103,107,112,143,147,226,229,233,248],[11,12,14],"h2",{"id":13},"un-plan-au-sol-de-votre-installation-électrique","Un plan au sol de votre installation électrique",[16,17,18,19,23,24,27,28,32],"p",{},"Le plan de situation (néerlandais : ",[20,21,22],"em",{},"situatieschema",", allemand : ",[20,25,26],{},"Situationsplan",") est un plan à l'échelle de votre bâtiment montrant la ",[29,30,31],"strong",{},"position physique"," de tous les composants électriques — prises, interrupteurs, luminaires, tableaux de distribution et chemins de câbles.",[16,34,35,36,39],{},"Contrairement au schéma unifilaire, le plan de situation ne montre pas la hiérarchie logique des circuits, mais ",[29,37,38],{},"où exactement"," tout se trouve.",[11,41,43],{"id":42},"que-dit-le-rgie","Que dit le RGIE ?",[16,45,46,47,50],{},"Selon le RGIE Art. 9.1 (Art. 269 dans l'ancien RGIE, depuis 2020 Art. 9.1), toute installation électrique en Belgique doit disposer de ",[29,48,49],{},"deux documents graphiques obligatoires"," :",[52,53,54,70],"table",{},[55,56,57],"thead",{},[58,59,60,64,67],"tr",{},[61,62,63],"th",{},"Document",[61,65,66],{},"Article RGIE",[61,68,69],{},"Montre",[71,72,73,87],"tbody",{},[58,74,75,81,84],{},[76,77,78],"td",{},[29,79,80],{},"Schéma unifilaire",[76,82,83],{},"Art. 9.1.2 Nr. 1",[76,85,86],{},"Structure logique — dispositifs de protection, circuits, hiérarchie",[58,88,89,94,97],{},[76,90,91],{},[29,92,93],{},"Plan de situation",[76,95,96],{},"Art. 9.1.2 Nr. 2",[76,98,99],{},"Position physique — où tout est installé dans le bâtiment, y compris l'emplacement du compteur et du système de mise à la terre",[16,101,102],{},"Les deux documents doivent être présentés lors de chaque contrôle électrique. Si l'un d'entre eux manque, le contrôle ne sera pas réussi.",[11,104,106],{"id":105},"que-doit-contenir-le-plan-de-situation","Que doit contenir le plan de situation ?",[108,109,111],"h3",{"id":110},"liste-de-vérification","Liste de vérification",[113,114,115,119,122,125,128,131,134,137,140],"ul",{},[116,117,118],"li",{},"Plan à l'échelle de chaque étage",[116,120,121],{},"Position de toutes les prises (simple, double, avec terre)",[116,123,124],{},"Position de tous les interrupteurs (on\u002Foff, va-et-vient, variateur)",[116,126,127],{},"Points lumineux (plafond, mur, extérieur)",[116,129,130],{},"Tableau de distribution et emplacement du compteur",[116,132,133],{},"Appareils fixes (plaque de cuisson, chauffe-eau, borne de recharge)",[116,135,136],{},"Chemins de câbles et zones d'installation",[116,138,139],{},"Numéros de référence des circuits (doivent correspondre au schéma unifilaire)",[116,141,142],{},"Symboles conformes au RGIE (selon le tableau 2.23 du RGIE, chapitre 2.13)",[11,144,146],{"id":145},"plan-de-situation-vs-schéma-unifilaire","Plan de situation vs. schéma unifilaire",[52,148,149,160],{},[55,150,151],{},[58,152,153,156,158],{},[61,154,155],{},"Propriété",[61,157,93],{},[61,159,80],{},[71,161,162,173,184,194,205,216],{},[58,163,164,167,170],{},[76,165,166],{},"Représentation",[76,168,169],{},"Plan au sol physique",[76,171,172],{},"Schéma logique des circuits",[58,174,175,178,181],{},[76,176,177],{},"Montre la position ?",[76,179,180],{},"Oui — emplacement exact",[76,182,183],{},"Non",[58,185,186,189,191],{},[76,187,188],{},"Montre la hiérarchie ?",[76,190,183],{},[76,192,193],{},"Oui — du réseau au consommateur",[58,195,196,199,202],{},[76,197,198],{},"Dispositifs de protection",[76,200,201],{},"Position uniquement",[76,203,204],{},"Calibres, type, coordination",[58,206,207,210,213],{},[76,208,209],{},"Info câbles",[76,211,212],{},"Chemins visibles",[76,214,215],{},"Type et section indiqués",[58,217,218,221,224],{},[76,219,220],{},"À l'échelle",[76,222,223],{},"Oui (1:50 ou 1:100)",[76,225,183],{},[16,227,228],{},"Les deux documents se complètent et sont également obligatoires.",[11,230,232],{"id":231},"articles-connexes","Articles connexes",[113,234,235,242],{},[116,236,237],{},[238,239,241],"a",{"href":240},"\u002Ffr\u002Fblog\u002Fschema-unifilaire","Créer un schéma unifilaire — étape par étape",[116,243,244],{},[238,245,247],{"href":246},"\u002Ffr\u002Fblog\u002Fcout-plan-electrique","Combien coûte un plan électrique en Belgique ?",[16,249,250],{},[238,251,253],{"href":252},"\u002F","Créez votre plan de situation avec PlanElec — gratuit →",{"title":255,"searchDepth":256,"depth":256,"links":257},"",2,[258,259,260,264,265],{"id":13,"depth":256,"text":14},{"id":42,"depth":256,"text":43},{"id":105,"depth":256,"text":106,"children":261},[262],{"id":110,"depth":263,"text":111},3,{"id":145,"depth":256,"text":146},{"id":231,"depth":256,"text":232},"faq","2026-03-06","Le plan de situation montre où tous les composants électriques sont physiquement installés dans votre bâtiment. Découvrez ce qu'il doit contenir et comment il se distingue du schéma unifilaire.","md","2026-06-05","fr",{},true,"\u002Fblog\u002Fwhat-is-a-situation-plan.fr","3 min",12,{"title":5,"description":268},"plan-de-situation","blog\u002Fwhat-is-a-situation-plan.fr",[281,282,283,22,26,284,285,286,287,288,289,290],"AREI","RGIE","plan de situation","situation plan","schéma unifilaire","eendraadschema","Eindrahtschema","contrôle électrique","plan au sol","Belgique","X6ppGJN74AI2FIOg-2CW1sb2MKE2JVCPLfJpt718W18",[293,552,809,986],{"id":294,"title":295,"articleId":6,"body":296,"category":266,"date":267,"description":538,"extension":269,"lastUpdated":270,"locale":539,"meta":540,"navigation":273,"path":541,"publishDate":267,"readTime":275,"refreshInterval":276,"seo":542,"slug":543,"stem":544,"tags":545,"__hash__":551},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.de.md","Was ist ein Situationsplan?",{"type":8,"value":297,"toc":529},[298,302,315,322,326,333,372,379,383,387,420,424,503,506,510,524],[11,299,301],{"id":300},"ein-grundriss-ihrer-elektroinstallation","Ein Grundriss Ihrer Elektroinstallation",[16,303,304,305,307,308,310,311,314],{},"Der Situationsplan (niederländisch: ",[20,306,22],{},", französisch: ",[20,309,283],{},") ist ein maßstabsgetreuer Grundriss Ihres Gebäudes, auf dem die ",[29,312,313],{},"physische Position"," aller elektrischen Komponenten eingezeichnet ist — Steckdosen, Schalter, Leuchten, Verteilerkasten und Kabelwege.",[16,316,317,318,321],{},"Anders als das Eindrahtschema zeigt der Situationsplan nicht die logische Schaltungshierarchie, sondern ",[29,319,320],{},"wo genau"," sich alles befindet.",[11,323,325],{"id":324},"was-sagt-das-arei","Was sagt das AREI?",[16,327,328,329,332],{},"Gemäß AREI Art. 9.1 (Art. 269 im alten AREI, seit 2020 Art. 9.1) muss jede elektrische Installation in Belgien über ",[29,330,331],{},"zwei zeichnerische Pflichtdokumente"," verfügen:",[52,334,335,348],{},[55,336,337],{},[58,338,339,342,345],{},[61,340,341],{},"Dokument",[61,343,344],{},"AREI-Artikel",[61,346,347],{},"Zeigt",[71,349,350,361],{},[58,351,352,356,358],{},[76,353,354],{},[29,355,287],{},[76,357,83],{},[76,359,360],{},"Logische Struktur — Schutzgeräte, Stromkreise, Hierarchie",[58,362,363,367,369],{},[76,364,365],{},[29,366,26],{},[76,368,96],{},[76,370,371],{},"Physische Position — wo ist alles im Gebäude installiert, inkl. Lage des Zählerkastens und der Erdungsanlage",[16,373,374,375,378],{},"Beide Dokumente sind bei jeder elektrischen Abnahme (",[20,376,377],{},"keuring",") vorzulegen. Fehlt eines davon, wird die Abnahme nicht bestanden.",[11,380,382],{"id":381},"was-muss-auf-den-situationsplan","Was muss auf den Situationsplan?",[108,384,386],{"id":385},"checkliste","Checkliste",[113,388,389,392,395,398,401,404,407,410,417],{},[116,390,391],{},"Maßstabsgetreuer Grundriss jeder Etage",[116,393,394],{},"Position aller Steckdosen (Einzel, Doppel, mit Erdung)",[116,396,397],{},"Position aller Schalter (Ein\u002FAus, Wechsel, Dimmer)",[116,399,400],{},"Beleuchtungspunkte (Decke, Wand, Außen)",[116,402,403],{},"Verteilerkasten und Zählerposition",[116,405,406],{},"Festanschlussgeräte (Kochfeld, Boiler, Wallbox)",[116,408,409],{},"Kabelverläufe und Installationszonen",[116,411,412,413,416],{},"Stromkreis-Referenznummern (die Nummerierung muss zwischen Situationsplan und Eindrahtschema ",[29,414,415],{},"identisch"," sein)",[116,418,419],{},"AREI-konforme Symbole (nach AREI Tabelle 2.23, Kapitel 2.13)",[11,421,423],{"id":422},"situationsplan-vs-eindrahtschema","Situationsplan vs. Eindrahtschema",[52,425,426,437],{},[55,427,428],{},[58,429,430,433,435],{},[61,431,432],{},"Eigenschaft",[61,434,26],{},[61,436,287],{},[71,438,439,450,461,471,482,493],{},[58,440,441,444,447],{},[76,442,443],{},"Darstellung",[76,445,446],{},"Physischer Grundriss",[76,448,449],{},"Logisches Schaltbild",[58,451,452,455,458],{},[76,453,454],{},"Zeigt Position?",[76,456,457],{},"Ja — wo genau",[76,459,460],{},"Nein",[58,462,463,466,468],{},[76,464,465],{},"Zeigt Hierarchie?",[76,467,460],{},[76,469,470],{},"Ja — vom Netz bis zum Verbraucher",[58,472,473,476,479],{},[76,474,475],{},"Schutzgeräte",[76,477,478],{},"Nur Position",[76,480,481],{},"Nennwerte, Typ, Koordination",[58,483,484,487,490],{},[76,485,486],{},"Kabelangaben",[76,488,489],{},"Verläufe sichtbar",[76,491,492],{},"Typ und Querschnitt angegeben",[58,494,495,498,501],{},[76,496,497],{},"Maßstab",[76,499,500],{},"Ja (1:50 oder 1:100)",[76,502,460],{},[16,504,505],{},"Beide Dokumente ergänzen sich und sind gleichermaßen Pflicht.",[11,507,509],{"id":508},"verwandte-artikel","Verwandte Artikel",[113,511,512,518],{},[116,513,514],{},[238,515,517],{"href":516},"\u002Fde\u002Fblog\u002Feindrahtschema-erstellen","Eindrahtschema selbst erstellen — Schritt für Schritt",[116,519,520],{},[238,521,523],{"href":522},"\u002Fde\u002Fblog\u002Felektroplan-kosten","Was kostet ein Elektroplan in Belgien?",[16,525,526],{},[238,527,528],{"href":252},"Erstellen Sie jetzt Ihren Situationsplan mit PlanElec — kostenlos →",{"title":255,"searchDepth":256,"depth":256,"links":530},[531,532,533,536,537],{"id":300,"depth":256,"text":301},{"id":324,"depth":256,"text":325},{"id":381,"depth":256,"text":382,"children":534},[535],{"id":385,"depth":263,"text":386},{"id":422,"depth":256,"text":423},{"id":508,"depth":256,"text":509},"Der Situationsplan zeigt, wo alle elektrischen Komponenten in Ihrem Gebäude physisch installiert sind. Erfahren Sie, was drauf muss und wie er sich vom Eindrahtschema unterscheidet.","de",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.de",{"title":295,"description":538},"was-ist-ein-situationsplan","blog\u002Fwhat-is-a-situation-plan.de",[281,282,26,22,283,284,287,546,285,547,548,549,550],"Eendraadschema","Stromabnahme","Keuring","Grundriss","Belgien","OYFr0gn_eQADg4OcSonvSvu9RaTtFqigrjQUgqwDYLY",{"id":553,"title":554,"articleId":6,"body":555,"category":266,"date":267,"description":797,"extension":269,"lastUpdated":270,"locale":798,"meta":799,"navigation":273,"path":800,"publishDate":267,"readTime":275,"refreshInterval":276,"seo":801,"slug":6,"stem":802,"tags":803,"__hash__":808},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.en.md","What Is a Situation Plan?",{"type":8,"value":556,"toc":788},[557,561,574,581,585,592,632,638,642,646,679,683,762,765,769,783],[11,558,560],{"id":559},"a-floor-plan-of-your-electrical-installation","A floor plan of your electrical installation",[16,562,563,564,566,567,569,570,573],{},"A situation plan (Dutch: ",[20,565,22],{},", French: ",[20,568,283],{},") is a scaled floor plan of your building showing the ",[29,571,572],{},"physical location"," of all electrical components — sockets, switches, lights, distribution boards, and cable routes.",[16,575,576,577,580],{},"Unlike a single-line diagram, the situation plan doesn't show the logical circuit hierarchy, but rather ",[29,578,579],{},"exactly where"," everything is located.",[11,582,584],{"id":583},"what-does-the-arei-say","What does the AREI say?",[16,586,587,588,591],{},"According to AREI Art. 9.1 (Art. 269 in the old AREI, since 2020 Art. 9.1), every electrical installation in Belgium must have ",[29,589,590],{},"two mandatory drawing documents",":",[52,593,594,606],{},[55,595,596],{},[58,597,598,600,603],{},[61,599,63],{},[61,601,602],{},"AREI Article",[61,604,605],{},"Shows",[71,607,608,620],{},[58,609,610,615,617],{},[76,611,612],{},[29,613,614],{},"Single-line diagram",[76,616,83],{},[76,618,619],{},"Logical structure — protection devices, circuits, hierarchy",[58,621,622,627,629],{},[76,623,624],{},[29,625,626],{},"Situation plan",[76,628,96],{},[76,630,631],{},"Physical location — where everything is installed in the building, incl. location of the meter board and earthing system",[16,633,634,635,637],{},"Both documents must be presented at every electrical inspection (",[20,636,377],{},"). If either of them is missing, the inspection will not pass.",[11,639,641],{"id":640},"what-must-be-on-the-situation-plan","What must be on the situation plan?",[108,643,645],{"id":644},"checklist","Checklist",[113,647,648,651,654,657,660,663,666,669,676],{},[116,649,650],{},"Scaled floor plan of each storey",[116,652,653],{},"Position of all sockets (single, double, earthed)",[116,655,656],{},"Position of all switches (on\u002Foff, two-way, dimmer)",[116,658,659],{},"Lighting points (ceiling, wall, outdoor)",[116,661,662],{},"Distribution board and meter location",[116,664,665],{},"Fixed appliances (hob, boiler, EV charger)",[116,667,668],{},"Cable routes and installation zones",[116,670,671,672,675],{},"Circuit reference numbers (numbering must be ",[29,673,674],{},"identical"," between situation plan and single-line diagram)",[116,677,678],{},"AREI-compliant symbols (per AREI Table 2.23, Chapter 2.13)",[11,680,682],{"id":681},"situation-plan-vs-single-line-diagram","Situation plan vs. single-line diagram",[52,684,685,696],{},[55,686,687],{},[58,688,689,692,694],{},[61,690,691],{},"Property",[61,693,626],{},[61,695,614],{},[71,697,698,709,720,730,741,752],{},[58,699,700,703,706],{},[76,701,702],{},"Representation",[76,704,705],{},"Physical floor plan",[76,707,708],{},"Logical circuit diagram",[58,710,711,714,717],{},[76,712,713],{},"Shows position?",[76,715,716],{},"Yes — exact location",[76,718,719],{},"No",[58,721,722,725,727],{},[76,723,724],{},"Shows hierarchy?",[76,726,719],{},[76,728,729],{},"Yes — from grid to consumer",[58,731,732,735,738],{},[76,733,734],{},"Protection devices",[76,736,737],{},"Position only",[76,739,740],{},"Ratings, type, coordination",[58,742,743,746,749],{},[76,744,745],{},"Cable info",[76,747,748],{},"Routes visible",[76,750,751],{},"Type and cross-section listed",[58,753,754,757,760],{},[76,755,756],{},"Scaled",[76,758,759],{},"Yes (1:50 or 1:100)",[76,761,719],{},[16,763,764],{},"Both documents complement each other and are equally mandatory.",[11,766,768],{"id":767},"related-articles","Related articles",[113,770,771,777],{},[116,772,773],{},[238,774,776],{"href":775},"\u002Fen\u002Fblog\u002Fsingle-line-diagram","How to create a single-line diagram — step by step",[116,778,779],{},[238,780,782],{"href":781},"\u002Fen\u002Fblog\u002Felectrical-plan-costs","How much does an electrical plan cost in Belgium?",[16,784,785],{},[238,786,787],{"href":252},"Create your situation plan with PlanElec now — free →",{"title":255,"searchDepth":256,"depth":256,"links":789},[790,791,792,795,796],{"id":559,"depth":256,"text":560},{"id":583,"depth":256,"text":584},{"id":640,"depth":256,"text":641,"children":793},[794],{"id":644,"depth":263,"text":645},{"id":681,"depth":256,"text":682},{"id":767,"depth":256,"text":768},"A situation plan shows where all electrical components are physically installed in your building. Learn what it must include and how it differs from a single-line diagram.","en",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.en",{"title":554,"description":797},"blog\u002Fwhat-is-a-situation-plan.en",[281,282,284,22,26,283,804,286,287,285,805,377,806,807],"single-line diagram","inspection","floor plan","Belgium","EkYxf7K1vxmCFLDvrNBN6L6QtQiUGo1AiBNgIgq3lNY",{"id":4,"title":5,"articleId":6,"body":810,"category":266,"date":267,"description":268,"extension":269,"lastUpdated":270,"locale":271,"meta":983,"navigation":273,"path":274,"publishDate":267,"readTime":275,"refreshInterval":276,"seo":984,"slug":278,"stem":279,"tags":985,"__hash__":291},{"type":8,"value":811,"toc":974},[812,814,822,826,828,832,866,868,870,872,892,894,956,958,960,970],[11,813,14],{"id":13},[16,815,18,816,23,818,27,820,32],{},[20,817,22],{},[20,819,26],{},[29,821,31],{},[16,823,35,824,39],{},[29,825,38],{},[11,827,43],{"id":42},[16,829,46,830,50],{},[29,831,49],{},[52,833,834,844],{},[55,835,836],{},[58,837,838,840,842],{},[61,839,63],{},[61,841,66],{},[61,843,69],{},[71,845,846,856],{},[58,847,848,852,854],{},[76,849,850],{},[29,851,80],{},[76,853,83],{},[76,855,86],{},[58,857,858,862,864],{},[76,859,860],{},[29,861,93],{},[76,863,96],{},[76,865,99],{},[16,867,102],{},[11,869,106],{"id":105},[108,871,111],{"id":110},[113,873,874,876,878,880,882,884,886,888,890],{},[116,875,118],{},[116,877,121],{},[116,879,124],{},[116,881,127],{},[116,883,130],{},[116,885,133],{},[116,887,136],{},[116,889,139],{},[116,891,142],{},[11,893,146],{"id":145},[52,895,896,906],{},[55,897,898],{},[58,899,900,902,904],{},[61,901,155],{},[61,903,93],{},[61,905,80],{},[71,907,908,916,924,932,940,948],{},[58,909,910,912,914],{},[76,911,166],{},[76,913,169],{},[76,915,172],{},[58,917,918,920,922],{},[76,919,177],{},[76,921,180],{},[76,923,183],{},[58,925,926,928,930],{},[76,927,188],{},[76,929,183],{},[76,931,193],{},[58,933,934,936,938],{},[76,935,198],{},[76,937,201],{},[76,939,204],{},[58,941,942,944,946],{},[76,943,209],{},[76,945,212],{},[76,947,215],{},[58,949,950,952,954],{},[76,951,220],{},[76,953,223],{},[76,955,183],{},[16,957,228],{},[11,959,232],{"id":231},[113,961,962,966],{},[116,963,964],{},[238,965,241],{"href":240},[116,967,968],{},[238,969,247],{"href":246},[16,971,972],{},[238,973,253],{"href":252},{"title":255,"searchDepth":256,"depth":256,"links":975},[976,977,978,981,982],{"id":13,"depth":256,"text":14},{"id":42,"depth":256,"text":43},{"id":105,"depth":256,"text":106,"children":979},[980],{"id":110,"depth":263,"text":111},{"id":145,"depth":256,"text":146},{"id":231,"depth":256,"text":232},{},{"title":5,"description":268},[281,282,283,22,26,284,285,286,287,288,289,290],{"id":987,"title":988,"articleId":6,"body":989,"category":266,"date":267,"description":1225,"extension":269,"lastUpdated":270,"locale":1226,"meta":1227,"navigation":273,"path":1228,"publishDate":267,"readTime":275,"refreshInterval":276,"seo":1229,"slug":1230,"stem":1231,"tags":1232,"__hash__":1236},"blog\u002Fblog\u002Fwhat-is-a-situation-plan.nl.md","Wat is een situatieschema?",{"type":8,"value":990,"toc":1216},[991,995,1008,1015,1019,1026,1065,1068,1072,1074,1107,1111,1190,1193,1197,1211],[11,992,994],{"id":993},"een-plattegrond-van-uw-elektrische-installatie","Een plattegrond van uw elektrische installatie",[16,996,997,998,1000,1001,1003,1004,1007],{},"Het situatieschema (Frans: ",[20,999,283],{},", Duits: ",[20,1002,26],{},") is een op schaal getekende plattegrond van uw gebouw met de ",[29,1005,1006],{},"fysieke positie"," van alle elektrische componenten — stopcontacten, schakelaars, verlichtingspunten, verdeelborden en kabelroutes.",[16,1009,1010,1011,1014],{},"In tegenstelling tot het eendraadschema toont het situatieschema niet de logische circuithiërarchie, maar ",[29,1012,1013],{},"waar precies"," alles zich bevindt.",[11,1016,1018],{"id":1017},"wat-zegt-het-arei","Wat zegt het AREI?",[16,1020,1021,1022,1025],{},"Volgens AREI Art. 9.1 (Art. 269 in het oude AREI, sinds 2020 Art. 9.1) moet elke elektrische installatie in België over ",[29,1023,1024],{},"twee verplichte tekeningen"," beschikken:",[52,1027,1028,1040],{},[55,1029,1030],{},[58,1031,1032,1034,1037],{},[61,1033,63],{},[61,1035,1036],{},"AREI-artikel",[61,1038,1039],{},"Toont",[71,1041,1042,1053],{},[58,1043,1044,1048,1050],{},[76,1045,1046],{},[29,1047,546],{},[76,1049,83],{},[76,1051,1052],{},"Logische structuur — beschermingstoestellen, kringen, hiërarchie",[58,1054,1055,1060,1062],{},[76,1056,1057],{},[29,1058,1059],{},"Situatieschema",[76,1061,96],{},[76,1063,1064],{},"Fysieke positie — waar alles in het gebouw is geïnstalleerd, incl. locatie van de meterkast en aardingsinstallatie",[16,1066,1067],{},"Beide documenten moeten bij elke elektrische keuring worden voorgelegd. Als er een ontbreekt, wordt de keuring niet goedgekeurd.",[11,1069,1071],{"id":1070},"wat-moet-op-het-situatieschema-staan","Wat moet op het situatieschema staan?",[108,1073,645],{"id":644},[113,1075,1076,1079,1082,1085,1088,1091,1094,1097,1104],{},[116,1077,1078],{},"Op schaal getekende plattegrond van elke verdieping",[116,1080,1081],{},"Positie van alle stopcontacten (enkel, dubbel, geaard)",[116,1083,1084],{},"Positie van alle schakelaars (aan\u002Fuit, wissel, dimmer)",[116,1086,1087],{},"Verlichtingspunten (plafond, wand, buiten)",[116,1089,1090],{},"Verdeelbord en meterpositie",[116,1092,1093],{},"Vast aangesloten toestellen (kookplaat, boiler, laadpaal)",[116,1095,1096],{},"Kabelroutes en installatiezones",[116,1098,1099,1100,1103],{},"Kringreferentienummers (de nummering moet tussen situatieschema en eendraadschema ",[29,1101,1102],{},"identiek"," zijn)",[116,1105,1106],{},"AREI-conforme symbolen (volgens AREI-tabel 2.23, hoofdstuk 2.13)",[11,1108,1110],{"id":1109},"situatieschema-vs-eendraadschema","Situatieschema vs. eendraadschema",[52,1112,1113,1124],{},[55,1114,1115],{},[58,1116,1117,1120,1122],{},[61,1118,1119],{},"Eigenschap",[61,1121,1059],{},[61,1123,546],{},[71,1125,1126,1137,1148,1158,1169,1180],{},[58,1127,1128,1131,1134],{},[76,1129,1130],{},"Weergave",[76,1132,1133],{},"Fysieke plattegrond",[76,1135,1136],{},"Logisch schakelschema",[58,1138,1139,1142,1145],{},[76,1140,1141],{},"Toont positie?",[76,1143,1144],{},"Ja — exacte locatie",[76,1146,1147],{},"Nee",[58,1149,1150,1153,1155],{},[76,1151,1152],{},"Toont hiërarchie?",[76,1154,1147],{},[76,1156,1157],{},"Ja — van net tot verbruiker",[58,1159,1160,1163,1166],{},[76,1161,1162],{},"Beschermingstoestellen",[76,1164,1165],{},"Alleen positie",[76,1167,1168],{},"Waarden, type, coördinatie",[58,1170,1171,1174,1177],{},[76,1172,1173],{},"Kabelinfo",[76,1175,1176],{},"Routes zichtbaar",[76,1178,1179],{},"Type en doorsnede vermeld",[58,1181,1182,1185,1188],{},[76,1183,1184],{},"Op schaal",[76,1186,1187],{},"Ja (1:50 of 1:100)",[76,1189,1147],{},[16,1191,1192],{},"Beide documenten vullen elkaar aan en zijn beide verplicht.",[11,1194,1196],{"id":1195},"gerelateerde-artikelen","Gerelateerde artikelen",[113,1198,1199,1205],{},[116,1200,1201],{},[238,1202,1204],{"href":1203},"\u002Fblog\u002Feendraadschema-maken","Eendraadschema zelf maken — stap voor stap",[116,1206,1207],{},[238,1208,1210],{"href":1209},"\u002Fblog\u002Fkosten-elektriciteitsplan","Wat kost een elektroplan in België?",[16,1212,1213],{},[238,1214,1215],{"href":252},"Maak nu uw situatieschema met PlanElec — gratis →",{"title":255,"searchDepth":256,"depth":256,"links":1217},[1218,1219,1220,1223,1224],{"id":993,"depth":256,"text":994},{"id":1017,"depth":256,"text":1018},{"id":1070,"depth":256,"text":1071,"children":1221},[1222],{"id":644,"depth":263,"text":645},{"id":1109,"depth":256,"text":1110},{"id":1195,"depth":256,"text":1196},"Het situatieschema toont waar alle elektrische componenten fysiek in uw gebouw zijn geïnstalleerd. Ontdek wat erop moet staan en hoe het verschilt van een eendraadschema.","nl",{},"\u002Fblog\u002Fwhat-is-a-situation-plan.nl",{"title":988,"description":1225},"wat-is-een-situatieschema","blog\u002Fwhat-is-a-situation-plan.nl",[281,282,22,1233,283,26,284,286,287,285,377,1234,1235],"situatieplan","plattegrond","België","Bg85rysu29-jX6swnRJm9T-VjPYmLc0_DI_JdN4ZnmU",1787555260523]