[{"data":1,"prerenderedAt":5681},["ShallowReactive",2],{"help-guide-nl-wat-controleert-de-zelfcontrole":3,"help-alternates-self-check-coverage":821,"help-related-nl":3730},{"id":4,"title":5,"body":6,"category":798,"description":799,"extension":800,"guideId":801,"locale":802,"meta":803,"navigation":804,"order":805,"path":806,"publishedAt":807,"readTime":808,"seo":809,"slug":810,"stem":811,"tags":812,"updatedAt":819,"__hash__":820},"help\u002Fhelp\u002Fself-check-coverage.nl.md","Wat controleert de AREI-zelfcontrole van PlanElec?",{"type":7,"value":8,"toc":780},"minimark",[9,13,16,24,30,35,50,53,58,277,281,335,339,407,411,452,456,523,527,555,559,600,604,707,711,714,720,726,732,738,742,745,770,774,777],[10,11,12],"p",{},"In PlanElec zitten twee verschillende dingen die makkelijk verward worden.",[10,14,15],{},"AREI-verwijzingen worden pas na de gedocumenteerde bron- en vakinhoudelijke vrijgave publiek gelinkt. Praktijkregels en plausibiliteitscontroles maken geen regeltekstclaim.",[10,17,18,19,23],{},"De ",[20,21,22],"strong",{},"automatische zelfcontrole"," dekt daarvan slechts een deel. Deze pagina zegt precies welk deel dat is. Wij vermelden de regels die getoetst worden én de gebieden waar de toepassing geen uitspraak doet, omdat een onvolledige controle die zich als volledig voordoet gevaarlijker is dan helemaal geen controle.",[25,26,27],"blockquote",{},[10,28,29],{},"De zelfcontrole is een voorbereiding. Het officiële oordeel komt uitsluitend van een erkend controleorganisme.",[31,32,34],"h2",{"id":33},"wat-automatisch-getoetst-wordt","Wat automatisch getoetst wordt",[10,36,37,38,41,42,45,46,49],{},"De toepassing kent op dit moment ",[20,39,40],{},"38 controles",". Daarvan verwijzen er ",[20,43,44],{},"25"," naar een concreet AREI-artikel; de overige ",[20,47,48],{},"13"," zijn praktijkregels of plausibiliteitscontroles die wij als zodanig aanduiden en die geen reglementaire verplichting zijn.",[10,51,52],{},"Een controle levert pas een resultaat op wanneer de nodige projectgegevens ingevuld zijn. Ontbreken die, dan markeert het rapport de controle als onvolledig — nooit als geslaagd.",[54,55,57],"h3",{"id":56},"beveiliging","Beveiliging",[59,60,61,80],"table",{},[62,63,64],"thead",{},[65,66,67,71,74,77],"tr",{},[68,69,70],"th",{},"Controle",[68,72,73],{},"Wat er getoetst wordt",[68,75,76],{},"Basis",[68,78,79],{},"Ernst",[81,82,83,98,111,124,137,150,162,176,189,202,214,226,239,251,264],"tbody",{},[65,84,85,89,92,95],{},[86,87,88],"td",{},"Hoofddifferentieelschakelaar",[86,90,91],{},"Aan het hoofd van de installatie moet een differentieelschakelaar van hoogstens 300 mA aanwezig zijn.",[86,93,94],{},"AREI 4.2.4.3",[86,96,97],{},"Fout",[65,99,100,103,106,109],{},[86,101,102],{},"Max. stroomkringen per hooggevoelige differentieel",[86,104,105],{},"Hoogstens 8 eindstroomkringen per hooggevoelige differentieelschakelaar (≤ 30 mA).",[86,107,108],{},"AREI 4.2.4.3.b",[86,110,97],{},[65,112,113,116,119,122],{},[86,114,115],{},"Nominale waarden van rolluikactoren",[86,117,118],{},"Rolluikactoren op DIN-rail vragen een automaat of aardlekautomaat stroomopwaarts; beveiligings- en motorlast blijven binnen de gecatalogiseerde ingangs- en kanaalwaarden.",[86,120,121],{},"Praktijkregel",[86,123,97],{},[65,125,126,129,132,135],{},[86,127,128],{},"Beveiliging van laadpunten (EV-laden)",[86,130,131],{},"Een laadpunt vraagt een eigen stroomkring, een toegewijde differentieelschakelaar en buiten minstens IP44.",[86,133,134],{},"AREI 7.22.4",[86,136,97],{},[65,138,139,142,145,147],{},[86,140,141],{},"Selectiviteit van differentieelschakelaars (praktijkaanbeveling)",[86,143,144],{},"Praktijkadvies: stem gevoeligheid en tijd af tussen boven- en ondergeschikte differentieelschakelaars (IEC 60364-5-53).",[86,146,121],{},[86,148,149],{},"Waarschuwing",[65,151,152,155,158,160],{},[86,153,154],{},"30mA-differentieel voor stopcontactkringen",[86,156,157],{},"Alle stopcontactkringen moeten door een differentieelschakelaar van 30 mA beschermd zijn.",[86,159,108],{},[86,161,97],{},[65,163,164,167,170,173],{},[86,165,166],{},"Overspanningsbeveiliging (SPD)",[86,168,169],{},"Een overspanningsbeveiliging (SPD) wordt beoordeeld op aanwezigheid; het AREI legt geen algemene plicht op.",[86,171,172],{},"AREI 4.5.1",[86,174,175],{},"Informatie",[65,177,178,181,184,187],{},[86,179,180],{},"Hoofdschakelaar min. 40 A",[86,182,183],{},"Een hoofdschakelaar moet aanwezig zijn en in huishoudelijke installaties minstens 40 A bedragen.",[86,185,186],{},"AREI 5.3.5.1.b",[86,188,97],{},[65,190,191,194,197,200],{},[86,192,193],{},"Hoofddifferentieel min. 40 A",[86,195,196],{},"De differentieelschakelaar aan het voedingspunt moet minstens 40 A nominale stroom hebben.",[86,198,199],{},"AREI 5.3.5.3.a",[86,201,97],{},[65,203,204,207,210,212],{},[86,205,206],{},"Verdeelbordindeling",[86,208,209],{},"Verdeelkast: bezetting binnen het aantal modules, een differentieelschakelaar per rij en een reserve van ongeveer 20 %.",[86,211,121],{},[86,213,149],{},[65,215,216,219,222,224],{},[86,217,218],{},"Ingebouwde wandverwarming: differentieel 100 mA",[86,220,221],{},"In wanden ingebouwde verwarmingsweerstanden boven 25 V AC vragen een afzonderlijke differentieelschakelaar van 100 mA.",[86,223,108],{},[86,225,97],{},[65,227,228,231,234,237],{},[86,229,230],{},"Poolconfiguratie van huishoudelijke installatie",[86,232,233],{},"Eenpolige automaten zijn in Belgische woningen met sterschakeling niet toegelaten; gebruik 1P+N.",[86,235,236],{},"AREI 4.4.4.2",[86,238,149],{},[65,240,241,244,247,249],{},[86,242,243],{},"Uitschakelkarakteristiek tegenover belastingstype",[86,245,246],{},"Praktijkadvies: de karakteristiek B, C of D van de automaat moet passen bij het type belasting.",[86,248,121],{},[86,250,149],{},[65,252,253,256,259,262],{},[86,254,255],{},"Back-upbeveiliging van voedingsleidingen tussen verdeelborden",[86,257,258],{},"Een voedingsleiding naar een onderverdeler vraagt een eigen beveiliging in de voedende kast en een consistente koppeling.",[86,260,261],{},"AREI 4.4.1.4",[86,263,97],{},[65,265,266,269,272,275],{},[86,267,268],{},"Uitschakelvermogen tegenover kortsluitstroom",[86,270,271],{},"Het uitschakelvermogen van elke automaat moet de verwachte kortsluitstroom aankunnen; enkel gecontroleerd bij ingevulde waarde.",[86,273,274],{},"AREI 5.3.5.5",[86,276,97],{},[54,278,280],{"id":279},"aarding","Aarding",[59,282,283,295],{},[62,284,285],{},[65,286,287,289,291,293],{},[68,288,70],{},[68,290,73],{},[68,292,76],{},[68,294,79],{},[81,296,297,310,323],{},[65,298,299,302,305,308],{},[86,300,301],{},"Hoofdequipotentiale verbinding",[86,303,304],{},"Er moet een hoofdequipotentiaalverbinding (aardingsrail) aanwezig zijn.",[86,306,307],{},"AREI 4.2.3.2",[86,309,97],{},[65,311,312,315,318,321],{},[86,313,314],{},"Aardingselektrode (aardingslus\u002Faardpen)",[86,316,317],{},"Bij een TT- of IT-net moet een aardingselektrode gedocumenteerd zijn.",[86,319,320],{},"AREI 4.2.3",[86,322,97],{},[65,324,325,328,331,333],{},[86,326,327],{},"Plausibiliteit van aarding en netaansluiting",[86,329,330],{},"Plausibiliteitscontrole: een openbare huishoudelijke 3×230 V-aansluiting met een opgeslagen TN-stelsel vraagt nazicht.",[86,332,121],{},[86,334,149],{},[54,336,338],{"id":337},"kabels-en-dimensionering","Kabels en dimensionering",[59,340,341,353],{},[62,342,343],{},[65,344,345,347,349,351],{},[68,346,70],{},[68,348,73],{},[68,350,76],{},[68,352,79],{},[81,354,355,368,381,394],{},[65,356,357,360,363,366],{},[86,358,359],{},"Kabeldoorsnede",[86,361,362],{},"De kabeldoorsnede moet passen bij de nominale stroom van de beveiliging.",[86,364,365],{},"AREI 5.2.2",[86,367,97],{},[65,369,370,373,376,379],{},[86,371,372],{},"Spanningsval (ΔU)",[86,374,375],{},"Spanningsval berekend uit kabellengte: richtwaarde 3 % voor verlichting en 5 % voor andere eindstroomkringen.",[86,377,378],{},"AREI 5.2.5",[86,380,97],{},[65,382,383,386,389,392],{},[86,384,385],{},"CPR-brandklasse van kabels",[86,387,388],{},"Afzonderlijk geplaatste kabels moeten de eigenschap F1 hebben of minstens CPR-klasse Eca halen; klasse Fca is niet toegestaan.",[86,390,391],{},"AREI 5.2.7.2",[86,393,97],{},[65,395,396,399,402,405],{},[86,397,398],{},"Bekabeling in holle wanden: Cca\u002FPreflex",[86,400,401],{},"Kabels in bouwkundige holle ruimtes lopen in een mantelbuis (Preflex) of halen minstens CPR-klasse Cca.",[86,403,404],{},"AREI 4.3.3.5.b",[86,406,97],{},[54,408,410],{"id":409},"belasting-van-stroomkringen","Belasting van stroomkringen",[59,412,413,425],{},[62,414,415],{},[65,416,417,419,421,423],{},[68,418,70],{},[68,420,73],{},[68,422,76],{},[68,424,79],{},[81,426,427,440],{},[65,428,429,432,435,438],{},[86,430,431],{},"Max. contactpunten per eindstroomkring",[86,433,434],{},"Hoogstens 8 stopcontacten en vaste toestellen per eindstroomkring; zuivere lichtpunten tellen niet mee.",[86,436,437],{},"AREI 5.3.5.2b",[86,439,97],{},[65,441,442,445,448,450],{},[86,443,444],{},"Faseonbalans",[86,446,447],{},"Praktijkadvies: de onbalans tussen de fasen blijft best onder 30 %.",[86,449,121],{},[86,451,149],{},[54,453,455],{"id":454},"ruimtes-en-zones","Ruimtes en zones",[59,457,458,470],{},[62,459,460],{},[65,461,462,464,466,468],{},[68,463,70],{},[68,465,73],{},[68,467,76],{},[68,469,79],{},[81,471,472,485,498,511],{},[65,473,474,477,480,483],{},[86,475,476],{},"30mA-beveiliging voor vochtige ruimten",[86,478,479],{},"Stopcontacten in vochtige ruimtes moeten door een differentieelschakelaar van 30 mA beschermd zijn.",[86,481,482],{},"AREI 4.2.4.4",[86,484,97],{},[65,486,487,490,493,496],{},[86,488,489],{},"30mA-differentieel voor badkamerkringen",[86,491,492],{},"Alle stroomkringen in badkamers en vochtige ruimtes moeten door een differentieelschakelaar van 30 mA beschermd zijn.",[86,494,495],{},"AREI 7.1.4.3",[86,497,97],{},[65,499,500,503,506,509],{},[86,501,502],{},"Badkamerzones 0\u002F1\u002F2: toegelaten materieel",[86,504,505],{},"In badkamervolumes 0, 1 en 2 is enkel bepaald materieel toegelaten; verdeelkasten zijn er verboden.",[86,507,508],{},"AREI 7.1.5.2",[86,510,97],{},[65,512,513,516,519,521],{},[86,514,515],{},"Rookmelderdekking (aanbeveling)",[86,517,518],{},"Niet-bindend advies op basis van de gewestelijke woningregels; het AREI zelf schrijft rookmelders voor woningen niet voor.",[86,520,121],{},[86,522,149],{},[54,524,526],{"id":525},"topologie-en-besturing","Topologie en besturing",[59,528,529,541],{},[62,530,531],{},[65,532,533,535,537,539],{},[68,534,70],{},[68,536,73],{},[68,538,76],{},[68,540,79],{},[81,542,543],{},[65,544,545,548,551,553],{},[86,546,547],{},"Stuurwegen van elektrische rolluiken",[86,549,550],{},"Plausibiliteitscontrole: directe schakelaars, actoringangen, centrale bedieningen en aandrijvingstypes vormen samen een samenhangend besturingstraject.",[86,552,121],{},[86,554,97],{},[54,556,558],{"id":557},"fotovoltaïsche-installatie","Fotovoltaïsche installatie",[59,560,561,573],{},[62,562,563],{},[65,564,565,567,569,571],{},[68,566,70],{},[68,568,73],{},[68,570,76],{},[68,572,79],{},[81,574,575,588],{},[65,576,577,580,583,586],{},[86,578,579],{},"Conformiteit van PV-installatie",[86,581,582],{},"PV-installatie: anti-eilandbedrijf, aarding van de modulekaders, waarschuwingsborden en kenmerking van DC- en AC-geleiders.",[86,584,585],{},"AREI 7.112.2",[86,587,97],{},[65,589,590,593,596,598],{},[86,591,592],{},"Somstroom in verdeelborden met meerdere voedingsbronnen",[86,594,595],{},"Bij een verdeelkast met eigen opwekking worden net- en bronstroom per fase opgeteld op gemeenschappelijk belaste secties.",[86,597,121],{},[86,599,97],{},[54,601,603],{"id":602},"volledigheid-van-het-dossier","Volledigheid van het dossier",[59,605,606,618],{},[62,607,608],{},[65,609,610,612,614,616],{},[68,611,70],{},[68,613,73],{},[68,615,76],{},[68,617,79],{},[81,619,620,632,645,658,670,683,695],{},[65,621,622,625,628,630],{},[86,623,624],{},"Volledige verbindingen",[86,626,627],{},"Elk element in het schema moet aangesloten zijn; losse knooppunten wijzen op een onvolledig model.",[86,629,121],{},[86,631,149],{},[65,633,634,637,640,643],{},[86,635,636],{},"Min. aantal verlichtingskringen",[86,638,639],{},"Praktijkadvies: minstens twee verlichtingsstroomkringen per wooneenheid.",[86,641,642],{},"AREI 5.3.5.2.b",[86,644,97],{},[65,646,647,650,653,656],{},[86,648,649],{},"Afzonderlijke stroomkringen voor grootverbruikers",[86,651,652],{},"Grote toestellen zoals wasmachine, droogkast, vaatwasser, kookplaat en oven vragen elk een eigen stroomkring.",[86,654,655],{},"AREI 4.3.3.3",[86,657,97],{},[65,659,660,663,666,668],{},[86,661,662],{},"Installatiedossier (AREI 9.1.2)",[86,664,665],{},"Het installatiedossier vraagt een eendraadschema, een situatieplan en een volledige cartouche; PV vraagt bijkomende documenten.",[86,667,121],{},[86,669,149],{},[65,671,672,675,678,681],{},[86,673,674],{},"Plaatsing van verbindings-\u002Faftakdozen",[86,676,677],{},"Structurele aftakdozen moeten precies één keer en consistent in het schema voorkomen.",[86,679,680],{},"AREI 3.1.2.3",[86,682,149],{},[65,684,685,688,691,693],{},[86,686,687],{},"Niet-gekoppelde elektrische grondplansymbolen",[86,689,690],{},"Toestellen op het grondplan zonder koppeling aan de elektrische topologie worden als informatie gemeld.",[86,692,121],{},[86,694,175],{},[65,696,697,700,703,705],{},[86,698,699],{},"Plausibiliteit van schakelgroepen",[86,701,702],{},"Plausibiliteitscontrole: een schakelgroep bevat minstens één schakelaar en minstens één geschakelde belasting.",[86,704,121],{},[86,706,149],{},[31,708,710],{"id":709},"wat-de-zelfcontrole-niet-beoordeelt","Wat de zelfcontrole niet beoordeelt",[10,712,713],{},"Deze onderdelen van Boek 1 blijven bewust buiten de automatische toetsing:",[10,715,716,719],{},[20,717,718],{},"Bijzondere installaties en ruimtes (Deel 7)."," Van de veertien hoofdstukken raakt PlanElec er drie, en die telkens gedeeltelijk: ruimtes met bad of douche (7.1), voeding van elektrische wegvoertuigen (7.22) en huishoudelijke fotovoltaïsche installaties (7.112). Niet gedekt zijn zwembaden (7.2), sauna's (7.3), werf- en buiteninstallaties (7.4), enge geleidende ruimtes (7.6), campings (7.8), jachthavens (7.9), foorinstallaties (7.11), fonteinen (7.100), stationerende voertuigen (7.101), explosieve atmosferen (7.102) en industriële accumulatorbatterijen (7.103).",[10,721,722,725],{},[20,723,724],{},"De gelijkstroomzijde."," Het model kent geen afzonderlijke rollen voor de geleiders L+, L-, M, PEM en PEL. Daardoor zijn geleiderkeuze, kleurstelling, gecombineerde beschermingsgeleiders, DC-differentieelgevoeligheid, de bescherming van de M-geleider en permanente isolatiebewaking bij een IT-stelsel niet toetsbaar. Voor PV blijft dat handwerk.",[10,727,728,731],{},[20,729,730],{},"De overgangsbepalingen van artikel 59 en 69."," Of een uitzondering voor een bestaande installatie geldt, hangt af van gegevens die niet uit een eendraadschema af te leiden zijn — onder meer de PEN-doorsnede, het werkelijke begin van de uitvoering ter plaatse en de aanwezigheid van een bewakingstoestel. PlanElec houdt wel rekening met de versoepelingen van Deel 8 door bepaalde bevindingen bij bestaande delen als aanwijzing te tonen in plaats van als fout, maar beslist de uitzondering niet zelf.",[10,733,734,737],{},[20,735,736],{},"Controles van installaties (Deel 6) en de gedragsvoorschriften (Deel 9)"," vallen buiten het bereik van een planningsinstrument. Enkel de samenstelling van het installatiedossier wordt getoetst.",[31,739,741],{"id":740},"wat-software-principieel-niet-kan-vaststellen","Wat software principieel niet kan vaststellen",[10,743,744],{},"Ook na verdere uitbreiding van het model blijven deze punten afhankelijk van meting, inzage of visuele controle ter plaatse:",[746,747,748,752,755,758,761,764,767],"ul",{},[749,750,751],"li",{},"de werkelijke bedrading, de doorverbinding en de polariteit van de geleiders;",[749,753,754],{},"de uitschakelkarakteristieken en de DC-geschiktheid van de effectief geplaatste toestellen;",[749,756,757],{},"de isolatiemeting en de werking van een permanent isolatiebewakingstoestel;",[749,759,760],{},"de mechanische en chemische weerstand en de corrosietoestand van de aarding;",[749,762,763],{},"de doeltreffendheid van de automatische uitschakeling en de reële aardingsimpedantie;",[749,765,766],{},"de geschiktheid en de certificering van omvormers, batterijen en PV-componenten;",[749,768,769],{},"de zone-indeling, de risicobeoordeling en de omstandigheden ter plaatse.",[31,771,773],{"id":772},"wat-dit-betekent-voor-uw-keuring","Wat dit betekent voor uw keuring",[10,775,776],{},"Gebruik de zelfcontrole om vermijdbare fouten vroeg te vinden: een ontbrekende differentieelschakelaar, een doorsnede die niet bij de beveiliging past, te veel contactpunten op één kring, een onvolledig dossier. Dat zijn precies de bevindingen die anders pas bij de keuring boven water komen.",[10,778,779],{},"Reken er niet op voor de gevallen hierboven. Daar blijven uw vakkennis en het oordeel van het controleorganisme doorslaggevend.",{"title":781,"searchDepth":782,"depth":782,"links":783},"",2,[784,795,796,797],{"id":33,"depth":782,"text":34,"children":785},[786,788,789,790,791,792,793,794],{"id":56,"depth":787,"text":57},3,{"id":279,"depth":787,"text":280},{"id":337,"depth":787,"text":338},{"id":409,"depth":787,"text":410},{"id":454,"depth":787,"text":455},{"id":525,"depth":787,"text":526},{"id":557,"depth":787,"text":558},{"id":602,"depth":787,"text":603},{"id":709,"depth":782,"text":710},{"id":740,"depth":782,"text":741},{"id":772,"depth":782,"text":773},"compliance","De volledige lijst van de regels die PlanElec automatisch toetst — en een even expliciete lijst van wat de zelfcontrole niet beoordeelt.","md","self-check-coverage","nl",{},true,4,"\u002Fhelp\u002Fself-check-coverage.nl","2026-08-17","7 min",{"title":5,"description":799},"wat-controleert-de-zelfcontrole","help\u002Fself-check-coverage.nl",[813,814,815,816,817,818],"AREI","RGIE","zelfcontrole","keuring","dekking","validatie","2026-08-18","PPdQf7GxXuI0xR6wwPeagOSzHElAo3urnvqpxvqGAPc",[822,1589,2353,3115],{"id":823,"title":824,"body":825,"category":798,"description":1575,"extension":800,"guideId":801,"locale":1576,"meta":1577,"navigation":804,"order":805,"path":1578,"publishedAt":807,"readTime":1579,"seo":1580,"slug":1581,"stem":1582,"tags":1583,"updatedAt":819,"__hash__":1588},"help\u002Fhelp\u002Fself-check-coverage.de.md","Was prüft die AREI-Selbstprüfung von PlanElec?",{"type":7,"value":826,"toc":1560},[827,830,833,840,845,849,862,865,869,1073,1077,1129,1133,1197,1201,1241,1245,1309,1313,1341,1345,1385,1389,1489,1493,1496,1502,1508,1514,1520,1524,1527,1550,1554,1557],[10,828,829],{},"In PlanElec stecken zwei Dinge, die leicht verwechselt werden.",[10,831,832],{},"AREI-Verweise werden erst nach der dokumentierten Quellen- und Fachfreigabe öffentlich verlinkt. Praxisregeln und Plausibilitätsprüfungen erheben keinen Regelwerk-Zitatanspruch.",[10,834,835,836,839],{},"Die ",[20,837,838],{},"automatische Selbstprüfung"," deckt davon nur einen Teil ab. Diese Seite sagt genau, welchen. Wir nennen die geprüften Regeln und ebenso die Bereiche, zu denen die Anwendung keine Aussage trifft — denn eine unvollständige Prüfung, die sich als vollständig ausgibt, ist gefährlicher als gar keine Prüfung.",[25,841,842],{},[10,843,844],{},"Die Selbstprüfung ist eine Vorbereitung. Das offizielle Urteil spricht ausschließlich eine zugelassene Kontrollstelle.",[31,846,848],{"id":847},"was-automatisch-geprüft-wird","Was automatisch geprüft wird",[10,850,851,852,855,856,858,859,861],{},"Die Anwendung kennt derzeit ",[20,853,854],{},"38 Prüfungen",". Davon verweisen ",[20,857,44],{}," auf einen konkreten AREI-Artikel; die übrigen ",[20,860,48],{}," sind Praxisregeln oder Plausibilitätsprüfungen, die wir als solche kennzeichnen und die keine regulatorische Pflicht darstellen.",[10,863,864],{},"Eine Prüfung liefert erst dann ein Ergebnis, wenn die nötigen Projektdaten erfasst sind. Fehlen sie, weist der Bericht die Prüfung als unvollständig aus — niemals als bestanden.",[54,866,868],{"id":867},"schutzmaßnahmen","Schutzmaßnahmen",[59,870,871,887],{},[62,872,873],{},[65,874,875,878,881,884],{},[68,876,877],{},"Prüfung",[68,879,880],{},"Was geprüft wird",[68,882,883],{},"Grundlage",[68,885,886],{},"Schweregrad",[81,888,889,902,914,927,939,952,964,977,989,1001,1013,1025,1037,1049,1061],{},[65,890,891,894,897,899],{},[86,892,893],{},"Haupt-Differentialschalter",[86,895,896],{},"Am Kopf der Installation muss ein Differentialschalter mit höchstens 300 mA vorhanden sein.",[86,898,94],{},[86,900,901],{},"Fehler",[65,903,904,907,910,912],{},[86,905,906],{},"Max. Stromkreise pro hochempfindlichem FI",[86,908,909],{},"Höchstens 8 Endstromkreise pro hoch­empfindlichem Differentialschalter (≤ 30 mA).",[86,911,108],{},[86,913,901],{},[65,915,916,919,922,925],{},[86,917,918],{},"Bemessungsgrenzen von Rollladenaktoren",[86,920,921],{},"Rollladenaktoren auf DIN-Schiene brauchen einen vorgeschalteten LS oder FI\u002FLS; Schutzorgan- und Motorlast bleiben innerhalb der katalogisierten Eingangs- und Kanaldaten.",[86,923,924],{},"Praxisregel",[86,926,901],{},[65,928,929,932,935,937],{},[86,930,931],{},"Wallbox-Schutz (EV-Laden)",[86,933,934],{},"Ein Ladepunkt braucht einen eigenen Stromkreis, einen dedizierten Differentialschalter und im Außenbereich mindestens IP44.",[86,936,134],{},[86,938,901],{},[65,940,941,944,947,949],{},[86,942,943],{},"FI-Selektivität (Praxisempfehlung)",[86,945,946],{},"Praxisempfehlung: Empfindlichkeit und Zeit zwischen vor- und nachgeschalteten Differentialschaltern staffeln (IEC 60364-5-53).",[86,948,924],{},[86,950,951],{},"Warnung",[65,953,954,957,960,962],{},[86,955,956],{},"30-mA-FI für Steckdosenstromkreise",[86,958,959],{},"Alle Steckdosenstromkreise müssen durch einen 30-mA-Differentialschalter geschützt sein.",[86,961,108],{},[86,963,901],{},[65,965,966,969,972,974],{},[86,967,968],{},"Überspannungsschutz (SPD)",[86,970,971],{},"Das Vorhandensein eines Überspannungsschutzgeräts (SPD) wird bewertet; das AREI schreibt keine generelle Pflicht vor.",[86,973,172],{},[86,975,976],{},"Information",[65,978,979,982,985,987],{},[86,980,981],{},"Hauptschalter mind. 40 A",[86,983,984],{},"Ein Hauptschalter muss vorhanden sein und in häuslichen Anlagen mindestens 40 A betragen.",[86,986,186],{},[86,988,901],{},[65,990,991,994,997,999],{},[86,992,993],{},"Haupt-FI mind. 40 A",[86,995,996],{},"Der Differentialschalter am Speisepunkt muss mindestens 40 A Nennstrom aufweisen.",[86,998,199],{},[86,1000,901],{},[65,1002,1003,1006,1009,1011],{},[86,1004,1005],{},"Verteiler-Layout",[86,1007,1008],{},"Verteiler: Belegung innerhalb der Modulanzahl, ein Differentialschalter je Reihe und rund 20 % Reserve.",[86,1010,924],{},[86,1012,951],{},[65,1014,1015,1018,1021,1023],{},[86,1016,1017],{},"Wandeinbauheizung: 100-mA-FI",[86,1019,1020],{},"In Wänden eingebaute Heizwiderstände über 25 V AC verlangen eine getrennte 100-mA-Differenzstromeinrichtung.",[86,1022,108],{},[86,1024,901],{},[65,1026,1027,1030,1033,1035],{},[86,1028,1029],{},"Polkonfiguration in Wohnanlagen",[86,1031,1032],{},"Einpolige Automaten sind in belgischen Wohnanlagen mit Sternschaltung nicht zulässig; 1P+N verwenden.",[86,1034,236],{},[86,1036,951],{},[65,1038,1039,1042,1045,1047],{},[86,1040,1041],{},"Auslösecharakteristik gegenüber Lasttyp",[86,1043,1044],{},"Praxisempfehlung: die Kennlinie B, C oder D des Automaten muss zur Lastart passen.",[86,1046,924],{},[86,1048,951],{},[65,1050,1051,1054,1057,1059],{},[86,1052,1053],{},"Feeder-Backup-Schutz zwischen Verteilern",[86,1055,1056],{},"Eine Speiseleitung zu einem Unterverteiler verlangt ein eigenes Schutzorgan im speisenden Verteiler und eine konsistente Zuordnung.",[86,1058,261],{},[86,1060,901],{},[65,1062,1063,1066,1069,1071],{},[86,1064,1065],{},"Ausschaltvermögen gegenüber Kurzschlussstrom",[86,1067,1068],{},"Das Ausschaltvermögen jedes Automaten muss dem erwarteten Kurzschlussstrom standhalten; nur bei erfasstem Wert geprüft.",[86,1070,274],{},[86,1072,901],{},[54,1074,1076],{"id":1075},"erdung","Erdung",[59,1078,1079,1091],{},[62,1080,1081],{},[65,1082,1083,1085,1087,1089],{},[68,1084,877],{},[68,1086,880],{},[68,1088,883],{},[68,1090,886],{},[81,1092,1093,1105,1117],{},[65,1094,1095,1098,1101,1103],{},[86,1096,1097],{},"Hauptpotentialausgleich",[86,1099,1100],{},"Ein Hauptpotentialausgleich (Erdungsschiene) muss vorhanden sein.",[86,1102,307],{},[86,1104,901],{},[65,1106,1107,1110,1113,1115],{},[86,1108,1109],{},"Erdungselektrode (Hauserder\u002FStaberder)",[86,1111,1112],{},"Bei einem TT- oder IT-Netz muss eine Erdungselektrode dokumentiert sein.",[86,1114,320],{},[86,1116,901],{},[65,1118,1119,1122,1125,1127],{},[86,1120,1121],{},"Plausibilität von Erdung und Netzanschluss",[86,1123,1124],{},"Plausibilitätsprüfung: ein öffentlicher häuslicher 3×230-V-Anschluss mit gespeichertem TN-System erfordert Nachprüfung.",[86,1126,924],{},[86,1128,951],{},[54,1130,1132],{"id":1131},"kabel-und-dimensionierung","Kabel und Dimensionierung",[59,1134,1135,1147],{},[62,1136,1137],{},[65,1138,1139,1141,1143,1145],{},[68,1140,877],{},[68,1142,880],{},[68,1144,883],{},[68,1146,886],{},[81,1148,1149,1161,1173,1185],{},[65,1150,1151,1154,1157,1159],{},[86,1152,1153],{},"Kabelquerschnitt",[86,1155,1156],{},"Der Kabelquerschnitt muss zum Nennstrom der Absicherung passen.",[86,1158,365],{},[86,1160,901],{},[65,1162,1163,1166,1169,1171],{},[86,1164,1165],{},"Spannungsfall (ΔU)",[86,1167,1168],{},"Spannungsfall aus der Kabellänge berechnet: Richtwert 3 % für Beleuchtung und 5 % für andere Endstromkreise.",[86,1170,378],{},[86,1172,901],{},[65,1174,1175,1178,1181,1183],{},[86,1176,1177],{},"CPR-Brandschutzklasse von Kabeln",[86,1179,1180],{},"Einzeln verlegte Kabel müssen die Eigenschaft F1 aufweisen oder mindestens CPR-Klasse Eca erreichen; Klasse Fca ist unzulässig.",[86,1182,391],{},[86,1184,901],{},[65,1186,1187,1190,1193,1195],{},[86,1188,1189],{},"Hohlwandverlegung: Cca\u002FPreflex",[86,1191,1192],{},"Kabel in baulichen Hohlräumen werden im Leerrohr (Preflex) geführt oder erreichen mindestens CPR-Klasse Cca.",[86,1194,404],{},[86,1196,901],{},[54,1198,1200],{"id":1199},"stromkreisbelastung","Stromkreisbelastung",[59,1202,1203,1215],{},[62,1204,1205],{},[65,1206,1207,1209,1211,1213],{},[68,1208,877],{},[68,1210,880],{},[68,1212,883],{},[68,1214,886],{},[81,1216,1217,1229],{},[65,1218,1219,1222,1225,1227],{},[86,1220,1221],{},"Max. Steckdosen\u002FGeräte pro Endstromkreis",[86,1223,1224],{},"Höchstens 8 Steckdosen und ortsfeste Geräte pro Endstromkreis; reine Lichtpunkte zählen nicht mit.",[86,1226,437],{},[86,1228,901],{},[65,1230,1231,1234,1237,1239],{},[86,1232,1233],{},"Phasen-Ungleichgewicht",[86,1235,1236],{},"Praxisempfehlung: die Unsymmetrie zwischen den Phasen sollte unter 30 % bleiben.",[86,1238,924],{},[86,1240,951],{},[54,1242,1244],{"id":1243},"räume-und-zonen","Räume und Zonen",[59,1246,1247,1259],{},[62,1248,1249],{},[65,1250,1251,1253,1255,1257],{},[68,1252,877],{},[68,1254,880],{},[68,1256,883],{},[68,1258,886],{},[81,1260,1261,1273,1285,1297],{},[65,1262,1263,1266,1269,1271],{},[86,1264,1265],{},"30-mA-Schutz für Feuchträume",[86,1267,1268],{},"Steckdosen in Feuchträumen müssen durch einen 30-mA-Differentialschalter geschützt sein.",[86,1270,482],{},[86,1272,901],{},[65,1274,1275,1278,1281,1283],{},[86,1276,1277],{},"30-mA-FI für Badezimmerstromkreise",[86,1279,1280],{},"Alle Stromkreise in Badezimmern und Feuchträumen müssen durch einen 30-mA-Differentialschalter geschützt sein.",[86,1282,495],{},[86,1284,901],{},[65,1286,1287,1290,1293,1295],{},[86,1288,1289],{},"Badbereiche 0\u002F1\u002F2: Zulässigkeit von Betriebsmitteln",[86,1291,1292],{},"In den Badezimmervolumen 0, 1 und 2 sind nur bestimmte Betriebsmittel zulässig; Verteiler sind dort verboten.",[86,1294,508],{},[86,1296,901],{},[65,1298,1299,1302,1305,1307],{},[86,1300,1301],{},"Rauchmelder-Abdeckung (Empfehlung)",[86,1303,1304],{},"Unverbindlicher Hinweis auf Basis der regionalen Wohnungsvorschriften; das AREI selbst schreibt Rauchmelder für Wohnungen nicht vor.",[86,1306,924],{},[86,1308,951],{},[54,1310,1312],{"id":1311},"topologie-und-steuerung","Topologie und Steuerung",[59,1314,1315,1327],{},[62,1316,1317],{},[65,1318,1319,1321,1323,1325],{},[68,1320,877],{},[68,1322,880],{},[68,1324,883],{},[68,1326,886],{},[81,1328,1329],{},[65,1330,1331,1334,1337,1339],{},[86,1332,1333],{},"Steuerwege elektrischer Rollläden",[86,1335,1336],{},"Plausibilitätsprüfung: direkte Schalter, Aktoreingänge, zentrale Bedienungen und Antriebsart ergeben zusammen einen widerspruchsfreien Steuerweg.",[86,1338,924],{},[86,1340,901],{},[54,1342,1344],{"id":1343},"photovoltaikanlage","Photovoltaikanlage",[59,1346,1347,1359],{},[62,1348,1349],{},[65,1350,1351,1353,1355,1357],{},[68,1352,877],{},[68,1354,880],{},[68,1356,883],{},[68,1358,886],{},[81,1360,1361,1373],{},[65,1362,1363,1366,1369,1371],{},[86,1364,1365],{},"Konformität der PV-Anlage",[86,1367,1368],{},"PV-Anlage: Anti-Islanding, Erdung der Modulrahmen, Warnschilder und Kennzeichnung der DC- und AC-Leiter.",[86,1370,585],{},[86,1372,901],{},[65,1374,1375,1378,1381,1383],{},[86,1376,1377],{},"Summenstrom in Verteilungen mit Einspeisung",[86,1379,1380],{},"Bei einem Verteiler mit eigener Erzeugung addieren sich Netz- und Quellenstrom je Phase auf gemeinsam belasteten Abschnitten.",[86,1382,924],{},[86,1384,901],{},[54,1386,1388],{"id":1387},"vollständigkeit-der-akte","Vollständigkeit der Akte",[59,1390,1391,1403],{},[62,1392,1393],{},[65,1394,1395,1397,1399,1401],{},[68,1396,877],{},[68,1398,880],{},[68,1400,883],{},[68,1402,886],{},[81,1404,1405,1417,1429,1441,1453,1465,1477],{},[65,1406,1407,1410,1413,1415],{},[86,1408,1409],{},"Vollständige Verbindungen",[86,1411,1412],{},"Jedes Element im Schema muss angeschlossen sein; lose Knoten weisen auf ein unvollständiges Modell hin.",[86,1414,924],{},[86,1416,951],{},[65,1418,1419,1422,1425,1427],{},[86,1420,1421],{},"Mindestanzahl Beleuchtungsstromkreise",[86,1423,1424],{},"Praxisempfehlung: mindestens zwei Beleuchtungsstromkreise pro Wohneinheit.",[86,1426,642],{},[86,1428,901],{},[65,1430,1431,1434,1437,1439],{},[86,1432,1433],{},"Eigene Stromkreise für Großgeräte",[86,1435,1436],{},"Großgeräte wie Waschmaschine, Trockner, Spülmaschine, Kochfeld und Backofen brauchen je einen eigenen Stromkreis.",[86,1438,655],{},[86,1440,901],{},[65,1442,1443,1446,1449,1451],{},[86,1444,1445],{},"Anlagenakte (AREI 9.1.2)",[86,1447,1448],{},"Die Anlagenakte verlangt Eindrahtschema, Situationsplan und vollständige Cartouche; PV erfordert zusätzliche Unterlagen.",[86,1450,924],{},[86,1452,951],{},[65,1454,1455,1458,1461,1463],{},[86,1456,1457],{},"Platzierung von Anschluss-\u002FAbzweigdosen",[86,1459,1460],{},"Strukturelle Abzweigdosen müssen genau einmal und konsistent im Schema erscheinen.",[86,1462,680],{},[86,1464,951],{},[65,1466,1467,1470,1473,1475],{},[86,1468,1469],{},"Unverknüpfte elektrische Grundrisssymbole",[86,1471,1472],{},"Geräte im Grundriss ohne Verknüpfung zur elektrischen Topologie werden als Information gemeldet.",[86,1474,924],{},[86,1476,976],{},[65,1478,1479,1482,1485,1487],{},[86,1480,1481],{},"Plausibilität von Schalter-Steuergruppen",[86,1483,1484],{},"Plausibilitätsprüfung: eine Schaltgruppe enthält mindestens einen Schalter und mindestens eine geschaltete Last.",[86,1486,924],{},[86,1488,951],{},[31,1490,1492],{"id":1491},"was-die-selbstprüfung-nicht-beurteilt","Was die Selbstprüfung nicht beurteilt",[10,1494,1495],{},"Diese Bereiche aus Buch 1 bleiben bewusst außerhalb der automatischen Prüfung:",[10,1497,1498,1501],{},[20,1499,1500],{},"Besondere Anlagen und Räume (Teil 7)."," Von vierzehn Kapiteln berührt PlanElec drei, und diese jeweils teilweise: Räume mit Badewanne oder Dusche (7.1), Speisung elektrischer Straßenfahrzeuge (7.22) und häusliche Photovoltaikanlagen (7.112). Nicht abgedeckt sind Schwimmbäder (7.2), Saunen (7.3), Baustellen- und Außenanlagen (7.4), enge leitfähige Räume (7.6), Campingplätze (7.8), Yachthäfen (7.9), Kirmesanlagen (7.11), Springbrunnen (7.100), abgestellte Fahrzeuge (7.101), explosionsfähige Atmosphären (7.102) und industrielle Akkumulatorenbatterien (7.103).",[10,1503,1504,1507],{},[20,1505,1506],{},"Die Gleichstromseite."," Das Modell kennt keine eigenen Rollen für die Leiter L+, L-, M, PEM und PEL. Leiterwahl, Farbgebung, kombinierte Schutzleiter, DC-Differenzstromempfindlichkeit, der Schutz des M-Leiters und die permanente Isolationsüberwachung im IT-System sind daher nicht prüfbar. Für Photovoltaik bleibt das Handarbeit.",[10,1509,1510,1513],{},[20,1511,1512],{},"Die Übergangsbestimmungen der Artikel 59 und 69."," Ob eine Ausnahme für eine bestehende Anlage greift, hängt von Angaben ab, die sich aus einem Eindrahtschema nicht ableiten lassen — unter anderem vom PEN-Querschnitt, vom tatsächlichen Ausführungsbeginn vor Ort und vom Vorhandensein eines Überwachungsgeräts. PlanElec berücksichtigt zwar die Lockerungen aus Teil 8, indem bestimmte Befunde an Bestandsteilen als Hinweis statt als Fehler erscheinen, entscheidet die Ausnahme aber nicht selbst.",[10,1515,1516,1519],{},[20,1517,1518],{},"Kontrollen von Anlagen (Teil 6) und die Verhaltensvorschriften (Teil 9)"," liegen außerhalb der Reichweite eines Planungswerkzeugs. Geprüft wird lediglich die Zusammensetzung der Anlagenakte.",[31,1521,1523],{"id":1522},"was-software-grundsätzlich-nicht-feststellen-kann","Was Software grundsätzlich nicht feststellen kann",[10,1525,1526],{},"Auch nach weiterem Ausbau des Modells bleiben diese Punkte auf Messung, Unterlagen oder Sichtprüfung vor Ort angewiesen:",[746,1528,1529,1532,1535,1538,1541,1544,1547],{},[749,1530,1531],{},"die tatsächliche Verdrahtung, die Durchgängigkeit und die Polung der Leiter;",[749,1533,1534],{},"die Auslösekennlinien und die DC-Eignung der real eingebauten Geräte;",[749,1536,1537],{},"die Isolationsmessung und die Funktion eines permanenten Isolationsüberwachungsgeräts;",[749,1539,1540],{},"die mechanische und chemische Beständigkeit sowie der Korrosionszustand der Erdung;",[749,1542,1543],{},"die Wirksamkeit der automatischen Abschaltung und die reale Erdungsimpedanz;",[749,1545,1546],{},"die Eignung und die Zertifizierung von Wechselrichtern, Batterien und PV-Komponenten;",[749,1548,1549],{},"die Zoneneinteilung, die Risikobeurteilung und die Bedingungen vor Ort.",[31,1551,1553],{"id":1552},"was-das-für-ihre-kontrolle-bedeutet","Was das für Ihre Kontrolle bedeutet",[10,1555,1556],{},"Nutzen Sie die Selbstprüfung, um vermeidbare Fehler früh zu finden: einen fehlenden Differentialschalter, einen Querschnitt, der nicht zur Absicherung passt, zu viele Kontaktpunkte an einem Stromkreis, eine unvollständige Akte. Genau diese Befunde tauchen sonst erst bei der Abnahme auf.",[10,1558,1559],{},"Verlassen Sie sich nicht darauf bei den oben genannten Fällen. Dort bleiben Ihre Fachkenntnis und das Urteil der Kontrollstelle maßgeblich.",{"title":781,"searchDepth":782,"depth":782,"links":1561},[1562,1572,1573,1574],{"id":847,"depth":782,"text":848,"children":1563},[1564,1565,1566,1567,1568,1569,1570,1571],{"id":867,"depth":787,"text":868},{"id":1075,"depth":787,"text":1076},{"id":1131,"depth":787,"text":1132},{"id":1199,"depth":787,"text":1200},{"id":1243,"depth":787,"text":1244},{"id":1311,"depth":787,"text":1312},{"id":1343,"depth":787,"text":1344},{"id":1387,"depth":787,"text":1388},{"id":1491,"depth":782,"text":1492},{"id":1522,"depth":782,"text":1523},{"id":1552,"depth":782,"text":1553},"Die vollständige Liste der Regeln, die PlanElec automatisch prüft — und eine ebenso ausdrückliche Liste dessen, was die Selbstprüfung nicht beurteilt.","de",{},"\u002Fhelp\u002Fself-check-coverage.de","7 Min.",{"title":824,"description":1575},"was-die-selbstpruefung-kontrolliert","help\u002Fself-check-coverage.de",[813,814,1584,1585,1586,1587],"Selbstprüfung","Kontrolle","Abdeckung","Validierung","qhzmfsmH5xtEXzuRkucSbBy8S82LMdde5STrM98DBYY",{"id":1590,"title":1591,"body":1592,"category":798,"description":2340,"extension":800,"guideId":801,"locale":2341,"meta":2342,"navigation":804,"order":805,"path":2343,"publishedAt":807,"readTime":808,"seo":2344,"slug":2345,"stem":2346,"tags":2347,"updatedAt":819,"__hash__":2352},"help\u002Fhelp\u002Fself-check-coverage.en.md","What does PlanElec's AREI self-check verify?",{"type":7,"value":1593,"toc":2325},[1594,1597,1600,1607,1612,1616,1629,1632,1636,1838,1842,1894,1898,1962,1966,2006,2010,2074,2078,2106,2110,2150,2154,2254,2258,2261,2267,2273,2279,2285,2289,2292,2315,2319,2322],[10,1595,1596],{},"PlanElec contains two things that are easily confused.",[10,1598,1599],{},"AREI\u002FRGIE references are linked publicly only after the documented source and subject-matter approvals. Practice rules and plausibility checks make no claim to quote the regulations.",[10,1601,1602,1603,1606],{},"The ",[20,1604,1605],{},"automatic self-check"," covers only part of it. This page states exactly which part. We list the rules that are checked and, just as plainly, the areas where the application makes no statement — because an incomplete check presenting itself as complete is more dangerous than no check at all.",[25,1608,1609],{},[10,1610,1611],{},"The self-check is preparation. Only an accredited inspection body issues the official assessment.",[31,1613,1615],{"id":1614},"what-is-checked-automatically","What is checked automatically",[10,1617,1618,1619,1622,1623,1625,1626,1628],{},"The application currently holds ",[20,1620,1621],{},"38 checks",". Of these, ",[20,1624,44],{}," point to a specific AREI article; the remaining ",[20,1627,48],{}," are practice rules or plausibility checks, marked as such, carrying no regulatory obligation.",[10,1630,1631],{},"A check only produces a result once the required project data has been entered. Where data is missing, the report marks the check as incomplete — never as passed.",[54,1633,1635],{"id":1634},"protection","Protection",[59,1637,1638,1653],{},[62,1639,1640],{},[65,1641,1642,1645,1648,1650],{},[68,1643,1644],{},"Check",[68,1646,1647],{},"What is verified",[68,1649,76],{},[68,1651,1652],{},"Severity",[81,1654,1655,1668,1680,1693,1705,1718,1730,1742,1754,1766,1778,1790,1802,1814,1826],{},[65,1656,1657,1660,1663,1665],{},[86,1658,1659],{},"Main RCD",[86,1661,1662],{},"A residual current device of at most 300 mA must be present at the head of the installation.",[86,1664,94],{},[86,1666,1667],{},"Error",[65,1669,1670,1673,1676,1678],{},[86,1671,1672],{},"Max. circuits per high-sensitivity RCD",[86,1674,1675],{},"At most 8 final circuits per high-sensitivity residual current device (≤ 30 mA).",[86,1677,108],{},[86,1679,1667],{},[65,1681,1682,1685,1688,1691],{},[86,1683,1684],{},"Shutter actuator ratings",[86,1686,1687],{},"DIN-rail shutter actuators require an upstream MCB or RCBO; protective-device and motor loads stay within the catalogued input and channel ratings.",[86,1689,1690],{},"Practice rule",[86,1692,1667],{},[65,1694,1695,1698,1701,1703],{},[86,1696,1697],{},"Charging-point protection (EV charging)",[86,1699,1700],{},"A charging point requires its own circuit, a dedicated residual current device and at least IP44 outdoors.",[86,1702,134],{},[86,1704,1667],{},[65,1706,1707,1710,1713,1715],{},[86,1708,1709],{},"RCD selectivity (practice recommendation)",[86,1711,1712],{},"Practice recommendation: grade sensitivity and time between upstream and downstream RCDs (IEC 60364-5-53).",[86,1714,1690],{},[86,1716,1717],{},"Warning",[65,1719,1720,1723,1726,1728],{},[86,1721,1722],{},"30 mA RCD for socket circuits",[86,1724,1725],{},"All socket circuits must be protected by a 30 mA residual current device.",[86,1727,108],{},[86,1729,1667],{},[65,1731,1732,1735,1738,1740],{},[86,1733,1734],{},"Surge protection (SPD)",[86,1736,1737],{},"The presence of a surge protective device (SPD) is assessed; the AREI imposes no general obligation.",[86,1739,172],{},[86,1741,976],{},[65,1743,1744,1747,1750,1752],{},[86,1745,1746],{},"Main switch min. 40 A",[86,1748,1749],{},"A main switch must be present and rated at least 40 A in domestic installations.",[86,1751,186],{},[86,1753,1667],{},[65,1755,1756,1759,1762,1764],{},[86,1757,1758],{},"Main RCD min. 40 A",[86,1760,1761],{},"The residual current device at the supply point must be rated at least 40 A.",[86,1763,199],{},[86,1765,1667],{},[65,1767,1768,1771,1774,1776],{},[86,1769,1770],{},"Distribution-board layout",[86,1772,1773],{},"Board: occupancy within the module count, one residual current device per row and roughly 20 % spare capacity.",[86,1775,1690],{},[86,1777,1717],{},[65,1779,1780,1783,1786,1788],{},[86,1781,1782],{},"Embedded wall heating: 100 mA RCD",[86,1784,1785],{},"Heating elements embedded in walls above 25 V AC require a separate 100 mA residual current device.",[86,1787,108],{},[86,1789,1667],{},[65,1791,1792,1795,1798,1800],{},[86,1793,1794],{},"Pole configuration in residential installations",[86,1796,1797],{},"Single-pole breakers are not permitted in Belgian dwellings with a star configuration; use 1P+N.",[86,1799,236],{},[86,1801,1717],{},[65,1803,1804,1807,1810,1812],{},[86,1805,1806],{},"Trip characteristic versus load type",[86,1808,1809],{},"Practice recommendation: the breaker curve B, C or D must match the load type.",[86,1811,1690],{},[86,1813,1717],{},[65,1815,1816,1819,1822,1824],{},[86,1817,1818],{},"Feeder back-up protection between distribution boards",[86,1820,1821],{},"A feeder to a sub-board requires its own protective device in the supplying board and a consistent link.",[86,1823,261],{},[86,1825,1667],{},[65,1827,1828,1831,1834,1836],{},[86,1829,1830],{},"Breaking capacity versus prospective short-circuit current",[86,1832,1833],{},"The breaking capacity of each breaker must withstand the prospective short-circuit current; checked only when the value is recorded.",[86,1835,274],{},[86,1837,1667],{},[54,1839,1841],{"id":1840},"earthing","Earthing",[59,1843,1844,1856],{},[62,1845,1846],{},[65,1847,1848,1850,1852,1854],{},[68,1849,1644],{},[68,1851,1647],{},[68,1853,76],{},[68,1855,1652],{},[81,1857,1858,1870,1882],{},[65,1859,1860,1863,1866,1868],{},[86,1861,1862],{},"Main equipotential bonding",[86,1864,1865],{},"A main equipotential bonding rail must be present.",[86,1867,307],{},[86,1869,1667],{},[65,1871,1872,1875,1878,1880],{},[86,1873,1874],{},"Earth electrode (ring earth\u002Fearth rod)",[86,1876,1877],{},"For a TT or IT system, an earth electrode must be documented.",[86,1879,320],{},[86,1881,1667],{},[65,1883,1884,1887,1890,1892],{},[86,1885,1886],{},"Earthing and supply plausibility",[86,1888,1889],{},"Plausibility check: a public domestic 3×230 V connection recorded as a TN system requires review.",[86,1891,1690],{},[86,1893,1717],{},[54,1895,1897],{"id":1896},"cables-and-sizing","Cables and sizing",[59,1899,1900,1912],{},[62,1901,1902],{},[65,1903,1904,1906,1908,1910],{},[68,1905,1644],{},[68,1907,1647],{},[68,1909,76],{},[68,1911,1652],{},[81,1913,1914,1926,1938,1950],{},[65,1915,1916,1919,1922,1924],{},[86,1917,1918],{},"Cable cross-section",[86,1920,1921],{},"The cable cross-section must match the rating of the protective device.",[86,1923,365],{},[86,1925,1667],{},[65,1927,1928,1931,1934,1936],{},[86,1929,1930],{},"Voltage drop (ΔU)",[86,1932,1933],{},"Voltage drop computed from cable length: guide value 3 % for lighting and 5 % for other final circuits.",[86,1935,378],{},[86,1937,1667],{},[65,1939,1940,1943,1946,1948],{},[86,1941,1942],{},"CPR cable fire-performance class",[86,1944,1945],{},"Individually laid cables must have the F1 property or reach at least CPR class Eca; class Fca is not permitted.",[86,1947,391],{},[86,1949,1667],{},[65,1951,1952,1955,1958,1960],{},[86,1953,1954],{},"Cables in hollow walls: Cca\u002FPreflex",[86,1956,1957],{},"Cables in building cavities run in conduit (Preflex) or reach at least CPR class Cca.",[86,1959,404],{},[86,1961,1667],{},[54,1963,1965],{"id":1964},"circuit-loading","Circuit loading",[59,1967,1968,1980],{},[62,1969,1970],{},[65,1971,1972,1974,1976,1978],{},[68,1973,1644],{},[68,1975,1647],{},[68,1977,76],{},[68,1979,1652],{},[81,1981,1982,1994],{},[65,1983,1984,1987,1990,1992],{},[86,1985,1986],{},"Max. contact points per final circuit",[86,1988,1989],{},"At most 8 sockets and fixed appliances per final circuit; lighting-only points are not counted.",[86,1991,437],{},[86,1993,1667],{},[65,1995,1996,1999,2002,2004],{},[86,1997,1998],{},"Phase imbalance",[86,2000,2001],{},"Practice recommendation: imbalance between phases should stay below 30 %.",[86,2003,1690],{},[86,2005,1717],{},[54,2007,2009],{"id":2008},"rooms-and-zones","Rooms and zones",[59,2011,2012,2024],{},[62,2013,2014],{},[65,2015,2016,2018,2020,2022],{},[68,2017,1644],{},[68,2019,1647],{},[68,2021,76],{},[68,2023,1652],{},[81,2025,2026,2038,2050,2062],{},[65,2027,2028,2031,2034,2036],{},[86,2029,2030],{},"30 mA protection for wet rooms",[86,2032,2033],{},"Sockets in damp rooms must be protected by a 30 mA residual current device.",[86,2035,482],{},[86,2037,1667],{},[65,2039,2040,2043,2046,2048],{},[86,2041,2042],{},"30 mA RCD for bathroom circuits",[86,2044,2045],{},"All circuits in bathrooms and damp rooms must be protected by a 30 mA residual current device.",[86,2047,495],{},[86,2049,1667],{},[65,2051,2052,2055,2058,2060],{},[86,2053,2054],{},"Bathroom zones 0\u002F1\u002F2: permitted equipment",[86,2056,2057],{},"In bathroom volumes 0, 1 and 2 only certain equipment is permitted; distribution boards are prohibited there.",[86,2059,508],{},[86,2061,1667],{},[65,2063,2064,2067,2070,2072],{},[86,2065,2066],{},"Smoke-detector coverage (recommendation)",[86,2068,2069],{},"Non-binding advice based on regional housing rules; the AREI itself does not mandate smoke detectors in dwellings.",[86,2071,1690],{},[86,2073,1717],{},[54,2075,2077],{"id":2076},"topology-and-control","Topology and control",[59,2079,2080,2092],{},[62,2081,2082],{},[65,2083,2084,2086,2088,2090],{},[68,2085,1644],{},[68,2087,1647],{},[68,2089,76],{},[68,2091,1652],{},[81,2093,2094],{},[65,2095,2096,2099,2102,2104],{},[86,2097,2098],{},"Electric shutter control paths",[86,2100,2101],{},"Plausibility check: direct switches, actuator inputs, central controls and drive types together form a consistent control path.",[86,2103,1690],{},[86,2105,1667],{},[54,2107,2109],{"id":2108},"photovoltaic-installation","Photovoltaic installation",[59,2111,2112,2124],{},[62,2113,2114],{},[65,2115,2116,2118,2120,2122],{},[68,2117,1644],{},[68,2119,1647],{},[68,2121,76],{},[68,2123,1652],{},[81,2125,2126,2138],{},[65,2127,2128,2131,2134,2136],{},[86,2129,2130],{},"PV installation compliance",[86,2132,2133],{},"PV installation: anti-islanding, earthing of module frames, warning signs and identification of DC and AC conductors.",[86,2135,585],{},[86,2137,1667],{},[65,2139,2140,2143,2146,2148],{},[86,2141,2142],{},"Combined current in distribution boards with multiple sources",[86,2144,2145],{},"In a board with local generation, grid and source currents add up per phase on jointly loaded sections.",[86,2147,1690],{},[86,2149,1667],{},[54,2151,2153],{"id":2152},"completeness-of-the-file","Completeness of the file",[59,2155,2156,2168],{},[62,2157,2158],{},[65,2159,2160,2162,2164,2166],{},[68,2161,1644],{},[68,2163,1647],{},[68,2165,76],{},[68,2167,1652],{},[81,2169,2170,2182,2194,2206,2218,2230,2242],{},[65,2171,2172,2175,2178,2180],{},[86,2173,2174],{},"Complete connections",[86,2176,2177],{},"Every element in the diagram must be connected; orphan nodes indicate an incomplete model.",[86,2179,1690],{},[86,2181,1717],{},[65,2183,2184,2187,2190,2192],{},[86,2185,2186],{},"Minimum number of lighting circuits",[86,2188,2189],{},"Practice recommendation: at least two lighting circuits per dwelling unit.",[86,2191,642],{},[86,2193,1667],{},[65,2195,2196,2199,2202,2204],{},[86,2197,2198],{},"Dedicated circuits for large appliances",[86,2200,2201],{},"Large appliances such as washing machine, dryer, dishwasher, hob and oven each require a dedicated circuit.",[86,2203,655],{},[86,2205,1667],{},[65,2207,2208,2211,2214,2216],{},[86,2209,2210],{},"Installation dossier (AREI 9.1.2)",[86,2212,2213],{},"The installation file requires a single-line diagram, a situation plan and a complete title block; PV needs additional documents.",[86,2215,1690],{},[86,2217,1717],{},[65,2219,2220,2223,2226,2228],{},[86,2221,2222],{},"Placement of connection\u002Fjunction boxes",[86,2224,2225],{},"Structural junction boxes must appear exactly once and consistently in the diagram.",[86,2227,680],{},[86,2229,1717],{},[65,2231,2232,2235,2238,2240],{},[86,2233,2234],{},"Unlinked electrical floor-plan symbols",[86,2236,2237],{},"Floor-plan devices without a link to the electrical topology are reported for information.",[86,2239,1690],{},[86,2241,976],{},[65,2243,2244,2247,2250,2252],{},[86,2245,2246],{},"Switch-control group plausibility",[86,2248,2249],{},"Plausibility check: a control group contains at least one switch and at least one switched load.",[86,2251,1690],{},[86,2253,1717],{},[31,2255,2257],{"id":2256},"what-the-self-check-does-not-assess","What the self-check does not assess",[10,2259,2260],{},"These areas of Book 1 deliberately remain outside the automatic check:",[10,2262,2263,2266],{},[20,2264,2265],{},"Special installations and locations (Part 7)."," Of fourteen chapters, PlanElec touches three, each only in part: rooms containing a bath or shower (7.1), supply of electric road vehicles (7.22) and domestic photovoltaic installations (7.112). Not covered: swimming pools (7.2), saunas (7.3), construction sites and outdoor installations (7.4), conductive confined spaces (7.6), camping sites (7.8), marinas (7.9), fairground installations (7.11), fountains (7.100), stationary vehicles (7.101), explosive atmospheres (7.102) and industrial accumulator batteries (7.103).",[10,2268,2269,2272],{},[20,2270,2271],{},"The direct-current side."," The model has no separate roles for the L+, L-, M, PEM and PEL conductors. Conductor selection, colouring, combined protective conductors, DC residual current sensitivity, protection of the M conductor and permanent insulation monitoring in an IT system are therefore not verifiable. For photovoltaics this remains manual work.",[10,2274,2275,2278],{},[20,2276,2277],{},"The transitional provisions of articles 59 and 69."," Whether an exception applies to an existing installation depends on data that cannot be derived from a single-line diagram — among others the PEN cross-section, the actual start of work on site and the presence of a monitoring device. PlanElec does take the relaxations of Part 8 into account by presenting certain findings on existing parts as indications rather than errors, but does not decide the exception itself.",[10,2280,2281,2284],{},[20,2282,2283],{},"Inspections of installations (Part 6) and the rules of conduct (Part 9)"," fall outside the reach of a planning tool. Only the composition of the installation file is checked.",[31,2286,2288],{"id":2287},"what-software-cannot-establish-in-principle","What software cannot establish in principle",[10,2290,2291],{},"Even after further extension of the model, these points remain dependent on measurement, documentation or visual inspection on site:",[746,2293,2294,2297,2300,2303,2306,2309,2312],{},[749,2295,2296],{},"the actual wiring, continuity and polarity of the conductors;",[749,2298,2299],{},"the tripping characteristics and DC suitability of the devices actually installed;",[749,2301,2302],{},"insulation measurement and the operation of a permanent insulation monitoring device;",[749,2304,2305],{},"the mechanical and chemical resistance and corrosion state of the earthing;",[749,2307,2308],{},"the effectiveness of automatic disconnection and the real earth impedance;",[749,2310,2311],{},"the suitability and certification of inverters, batteries and PV components;",[749,2313,2314],{},"zoning, risk assessment and on-site conditions.",[31,2316,2318],{"id":2317},"what-this-means-for-your-inspection","What this means for your inspection",[10,2320,2321],{},"Use the self-check to catch avoidable mistakes early: a missing residual current device, a cross-section that does not match the protection, too many contact points on one circuit, an incomplete file. These are exactly the findings that otherwise surface only at inspection.",[10,2323,2324],{},"Do not rely on it for the cases listed above. There, your expertise and the judgement of the accredited body remain decisive.",{"title":781,"searchDepth":782,"depth":782,"links":2326},[2327,2337,2338,2339],{"id":1614,"depth":782,"text":1615,"children":2328},[2329,2330,2331,2332,2333,2334,2335,2336],{"id":1634,"depth":787,"text":1635},{"id":1840,"depth":787,"text":1841},{"id":1896,"depth":787,"text":1897},{"id":1964,"depth":787,"text":1965},{"id":2008,"depth":787,"text":2009},{"id":2076,"depth":787,"text":2077},{"id":2108,"depth":787,"text":2109},{"id":2152,"depth":787,"text":2153},{"id":2256,"depth":782,"text":2257},{"id":2287,"depth":782,"text":2288},{"id":2317,"depth":782,"text":2318},"The complete list of rules PlanElec checks automatically — and an equally explicit list of what the self-check does not assess.","en",{},"\u002Fhelp\u002Fself-check-coverage.en",{"title":1591,"description":2340},"what-the-self-check-verifies","help\u002Fself-check-coverage.en",[813,814,2348,2349,2350,2351],"self-check","inspection","coverage","validation","vzS7v_4jTdxIKNrBFeCemo2bOg4FsWZhhPciQ34uh6s",{"id":2354,"title":2355,"body":2356,"category":798,"description":3103,"extension":800,"guideId":801,"locale":3104,"meta":3105,"navigation":804,"order":805,"path":3106,"publishedAt":807,"readTime":808,"seo":3107,"slug":3108,"stem":3109,"tags":3110,"updatedAt":819,"__hash__":3114},"help\u002Fhelp\u002Fself-check-coverage.fr.md","Que vérifie l'autocontrôle RGIE de PlanElec ?",{"type":7,"value":2357,"toc":3088},[2358,2361,2364,2371,2376,2380,2393,2396,2398,2601,2605,2657,2661,2725,2729,2769,2773,2837,2841,2869,2873,2913,2917,3017,3021,3024,3030,3036,3042,3048,3052,3055,3078,3082,3085],[10,2359,2360],{},"PlanElec réunit deux choses qu'il est facile de confondre.",[10,2362,2363],{},"Les références RGIE ne sont liées publiquement qu’après les validations documentées de la source et du fond. Les règles de pratique et contrôles de plausibilité ne prétendent pas citer le règlement.",[10,2365,2366,2367,2370],{},"L'",[20,2368,2369],{},"autocontrôle automatique"," n'en couvre qu'une partie. Cette page indique précisément laquelle. Nous énumérons les règles vérifiées et les domaines où l'application ne se prononce pas, car un contrôle incomplet qui se présente comme complet est plus dangereux qu'une absence de contrôle.",[25,2372,2373],{},[10,2374,2375],{},"L'autocontrôle est une préparation. Seul un organisme de contrôle agréé délivre le jugement officiel.",[31,2377,2379],{"id":2378},"ce-qui-est-vérifié-automatiquement","Ce qui est vérifié automatiquement",[10,2381,2382,2383,2386,2387,2389,2390,2392],{},"L'application compte actuellement ",[20,2384,2385],{},"38 contrôles",". Parmi eux, ",[20,2388,44],{}," renvoient à un article précis du RGIE ; les ",[20,2391,48],{}," autres sont des règles de pratique ou des contrôles de plausibilité, signalés comme tels, sans caractère réglementaire.",[10,2394,2395],{},"Un contrôle ne produit un résultat que si les données de projet nécessaires sont renseignées. À défaut, le rapport marque le contrôle comme incomplet — jamais comme réussi.",[54,2397,1635],{"id":1634},[59,2399,2400,2416],{},[62,2401,2402],{},[65,2403,2404,2407,2410,2413],{},[68,2405,2406],{},"Contrôle",[68,2408,2409],{},"Ce qui est vérifié",[68,2411,2412],{},"Base",[68,2414,2415],{},"Gravité",[81,2417,2418,2431,2443,2456,2468,2481,2493,2505,2517,2529,2541,2553,2565,2577,2589],{},[65,2419,2420,2423,2426,2428],{},[86,2421,2422],{},"Différentiel principal",[86,2424,2425],{},"En tête d'installation, un différentiel de 300 mA au maximum doit être présent.",[86,2427,94],{},[86,2429,2430],{},"Erreur",[65,2432,2433,2436,2439,2441],{},[86,2434,2435],{},"Max. de circuits par différentiel à haute sensibilité",[86,2437,2438],{},"Au maximum 8 circuits terminaux par différentiel à haute sensibilité (≤ 30 mA).",[86,2440,108],{},[86,2442,2430],{},[65,2444,2445,2448,2451,2454],{},[86,2446,2447],{},"Calibres des actionneurs de volets",[86,2449,2450],{},"Les actionneurs de volet sur rail DIN exigent un disjoncteur ou différentiel en amont ; les charges de protection et de moteur restent dans les valeurs d'entrée et de canal du catalogue.",[86,2452,2453],{},"Règle de pratique",[86,2455,2430],{},[65,2457,2458,2461,2464,2466],{},[86,2459,2460],{},"Protection des bornes de recharge (VE)",[86,2462,2463],{},"Un point de charge exige un circuit propre, un différentiel dédié et au moins IP44 à l'extérieur.",[86,2465,134],{},[86,2467,2430],{},[65,2469,2470,2473,2476,2478],{},[86,2471,2472],{},"Sélectivité des différentiels (recommandation pratique)",[86,2474,2475],{},"Recommandation de pratique : échelonner sensibilité et temporisation entre différentiels amont et aval (CEI 60364-5-53).",[86,2477,2453],{},[86,2479,2480],{},"Avertissement",[65,2482,2483,2486,2489,2491],{},[86,2484,2485],{},"Différentiel 30 mA pour les circuits de prises",[86,2487,2488],{},"Tous les circuits de prises doivent être protégés par un différentiel de 30 mA.",[86,2490,108],{},[86,2492,2430],{},[65,2494,2495,2498,2501,2503],{},[86,2496,2497],{},"Protection contre les surtensions (SPD)",[86,2499,2500],{},"La présence d’un parafoudre (SPD) est évaluée ; le RGIE n’impose pas d’obligation générale.",[86,2502,172],{},[86,2504,976],{},[65,2506,2507,2510,2513,2515],{},[86,2508,2509],{},"Interrupteur principal min. 40 A",[86,2511,2512],{},"Un interrupteur général doit être présent et atteindre au moins 40 A dans les installations domestiques.",[86,2514,186],{},[86,2516,2430],{},[65,2518,2519,2522,2525,2527],{},[86,2520,2521],{},"Différentiel principal min. 40 A",[86,2523,2524],{},"Le différentiel au point d’alimentation doit présenter un calibre d’au moins 40 A.",[86,2526,199],{},[86,2528,2430],{},[65,2530,2531,2534,2537,2539],{},[86,2532,2533],{},"Implantation du tableau",[86,2535,2536],{},"Tableau : occupation dans la limite des modules, un différentiel par rangée et une réserve d’environ 20 %.",[86,2538,2453],{},[86,2540,2480],{},[65,2542,2543,2546,2549,2551],{},[86,2544,2545],{},"Chauffage encastré en paroi : différentiel 100 mA",[86,2547,2548],{},"Les résistances chauffantes noyées dans les parois au-delà de 25 V CA exigent un différentiel séparé de 100 mA.",[86,2550,108],{},[86,2552,2430],{},[65,2554,2555,2558,2561,2563],{},[86,2556,2557],{},"Configuration des pôles en installation domestique",[86,2559,2560],{},"Les disjoncteurs unipolaires ne sont pas admis dans les habitations belges en schéma étoile ; utilisez 1P+N.",[86,2562,236],{},[86,2564,2480],{},[65,2566,2567,2570,2573,2575],{},[86,2568,2569],{},"Courbe de déclenchement selon le type de charge",[86,2571,2572],{},"Recommandation de pratique : la courbe B, C ou D du disjoncteur doit correspondre au type de charge.",[86,2574,2453],{},[86,2576,2480],{},[65,2578,2579,2582,2585,2587],{},[86,2580,2581],{},"Protection amont des départs entre tableaux",[86,2583,2584],{},"Une liaison vers un tableau divisionnaire exige une protection propre dans le tableau amont et un couplage cohérent.",[86,2586,261],{},[86,2588,2430],{},[65,2590,2591,2594,2597,2599],{},[86,2592,2593],{},"Pouvoir de coupure par rapport au courant de court-circuit",[86,2595,2596],{},"Le pouvoir de coupure de chaque disjoncteur doit supporter le courant de court-circuit présumé ; vérifié uniquement si la valeur est renseignée.",[86,2598,274],{},[86,2600,2430],{},[54,2602,2604],{"id":2603},"mise-à-la-terre","Mise à la terre",[59,2606,2607,2619],{},[62,2608,2609],{},[65,2610,2611,2613,2615,2617],{},[68,2612,2406],{},[68,2614,2409],{},[68,2616,2412],{},[68,2618,2415],{},[81,2620,2621,2633,2645],{},[65,2622,2623,2626,2629,2631],{},[86,2624,2625],{},"Liaison équipotentielle principale",[86,2627,2628],{},"Une liaison équipotentielle principale (barrette de terre) doit être présente.",[86,2630,307],{},[86,2632,2430],{},[65,2634,2635,2638,2641,2643],{},[86,2636,2637],{},"Prise de terre (boucle\u002Fpiquet)",[86,2639,2640],{},"Pour un réseau TT ou IT, une prise de terre doit être documentée.",[86,2642,320],{},[86,2644,2430],{},[65,2646,2647,2650,2653,2655],{},[86,2648,2649],{},"Cohérence de la mise à la terre et du raccordement",[86,2651,2652],{},"Contrôle de plausibilité : un raccordement domestique public 3×230 V avec un schéma TN enregistré demande vérification.",[86,2654,2453],{},[86,2656,2480],{},[54,2658,2660],{"id":2659},"câbles-et-dimensionnement","Câbles et dimensionnement",[59,2662,2663,2675],{},[62,2664,2665],{},[65,2666,2667,2669,2671,2673],{},[68,2668,2406],{},[68,2670,2409],{},[68,2672,2412],{},[68,2674,2415],{},[81,2676,2677,2689,2701,2713],{},[65,2678,2679,2682,2685,2687],{},[86,2680,2681],{},"Section des câbles",[86,2683,2684],{},"La section du câble doit correspondre au calibre de la protection.",[86,2686,365],{},[86,2688,2430],{},[65,2690,2691,2694,2697,2699],{},[86,2692,2693],{},"Chute de tension (ΔU)",[86,2695,2696],{},"Chute de tension calculée sur la longueur du câble : valeur indicative de 3 % en éclairage et 5 % pour les autres circuits terminaux.",[86,2698,378],{},[86,2700,2430],{},[65,2702,2703,2706,2709,2711],{},[86,2704,2705],{},"Classe de réaction au feu CPR des câbles",[86,2707,2708],{},"Les câbles posés individuellement doivent présenter la propriété F1 ou atteindre au moins la classe CPR Eca ; la classe Fca est interdite.",[86,2710,391],{},[86,2712,2430],{},[65,2714,2715,2718,2721,2723],{},[86,2716,2717],{},"Pose en parois creuses : Cca\u002FPreflex",[86,2719,2720],{},"Les câbles dans les cavités constructives passent en gaine (Preflex) ou atteignent au moins la classe CPR Cca.",[86,2722,404],{},[86,2724,2430],{},[54,2726,2728],{"id":2727},"charge-des-circuits","Charge des circuits",[59,2730,2731,2743],{},[62,2732,2733],{},[65,2734,2735,2737,2739,2741],{},[68,2736,2406],{},[68,2738,2409],{},[68,2740,2412],{},[68,2742,2415],{},[81,2744,2745,2757],{},[65,2746,2747,2750,2753,2755],{},[86,2748,2749],{},"Max. prises\u002Fappareils par circuit terminal",[86,2751,2752],{},"Au maximum 8 prises et appareils fixes par circuit terminal ; les points lumineux seuls ne comptent pas.",[86,2754,437],{},[86,2756,2430],{},[65,2758,2759,2762,2765,2767],{},[86,2760,2761],{},"Déséquilibre des phases",[86,2763,2764],{},"Recommandation de pratique : le déséquilibre entre phases reste de préférence sous 30 %.",[86,2766,2453],{},[86,2768,2480],{},[54,2770,2772],{"id":2771},"locaux-et-volumes","Locaux et volumes",[59,2774,2775,2787],{},[62,2776,2777],{},[65,2778,2779,2781,2783,2785],{},[68,2780,2406],{},[68,2782,2409],{},[68,2784,2412],{},[68,2786,2415],{},[81,2788,2789,2801,2813,2825],{},[65,2790,2791,2794,2797,2799],{},[86,2792,2793],{},"Protection 30 mA des locaux humides",[86,2795,2796],{},"Les prises des locaux humides doivent être protégées par un différentiel de 30 mA.",[86,2798,482],{},[86,2800,2430],{},[65,2802,2803,2806,2809,2811],{},[86,2804,2805],{},"Différentiel 30 mA pour les circuits de salle de bains",[86,2807,2808],{},"Tous les circuits des salles de bains et locaux humides doivent être protégés par un différentiel de 30 mA.",[86,2810,495],{},[86,2812,2430],{},[65,2814,2815,2818,2821,2823],{},[86,2816,2817],{},"Volumes 0\u002F1\u002F2 de salle de bains : admissibilité du matériel",[86,2819,2820],{},"Dans les volumes de salle de bains 0, 1 et 2, seul certain matériel est admis ; les tableaux y sont interdits.",[86,2822,508],{},[86,2824,2430],{},[65,2826,2827,2830,2833,2835],{},[86,2828,2829],{},"Couverture des détecteurs de fumée (recommandation)",[86,2831,2832],{},"Avis non contraignant fondé sur les règles régionales du logement ; le RGIE lui-même n’impose pas de détecteurs de fumée en habitation.",[86,2834,2453],{},[86,2836,2480],{},[54,2838,2840],{"id":2839},"topologie-et-commande","Topologie et commande",[59,2842,2843,2855],{},[62,2844,2845],{},[65,2846,2847,2849,2851,2853],{},[68,2848,2406],{},[68,2850,2409],{},[68,2852,2412],{},[68,2854,2415],{},[81,2856,2857],{},[65,2858,2859,2862,2865,2867],{},[86,2860,2861],{},"Chaînes de commande des volets électriques",[86,2863,2864],{},"Contrôle de plausibilité : interrupteurs directs, entrées d’actionneur, commandes centrales et types de moteur forment un chemin de commande cohérent.",[86,2866,2453],{},[86,2868,2430],{},[54,2870,2872],{"id":2871},"installation-photovoltaïque","Installation photovoltaïque",[59,2874,2875,2887],{},[62,2876,2877],{},[65,2878,2879,2881,2883,2885],{},[68,2880,2406],{},[68,2882,2409],{},[68,2884,2412],{},[68,2886,2415],{},[81,2888,2889,2901],{},[65,2890,2891,2894,2897,2899],{},[86,2892,2893],{},"Conformité de l'installation photovoltaïque",[86,2895,2896],{},"Installation PV : anti-îlotage, mise à la terre des cadres de modules, panneaux d’avertissement et repérage des conducteurs CC et CA.",[86,2898,585],{},[86,2900,2430],{},[65,2902,2903,2906,2909,2911],{},[86,2904,2905],{},"Courant cumulé dans les tableaux à sources multiples",[86,2907,2908],{},"Dans un tableau avec production propre, courants du réseau et de la source s’additionnent par phase sur les tronçons communs.",[86,2910,2453],{},[86,2912,2430],{},[54,2914,2916],{"id":2915},"complétude-du-dossier","Complétude du dossier",[59,2918,2919,2931],{},[62,2920,2921],{},[65,2922,2923,2925,2927,2929],{},[68,2924,2406],{},[68,2926,2409],{},[68,2928,2412],{},[68,2930,2415],{},[81,2932,2933,2945,2957,2969,2981,2993,3005],{},[65,2934,2935,2938,2941,2943],{},[86,2936,2937],{},"Connexions complètes",[86,2939,2940],{},"Chaque élément du schéma doit être raccordé ; un nœud isolé signale un modèle incomplet.",[86,2942,2453],{},[86,2944,2480],{},[65,2946,2947,2950,2953,2955],{},[86,2948,2949],{},"Nombre minimal de circuits d'éclairage",[86,2951,2952],{},"Recommandation de pratique : au moins deux circuits d’éclairage par unité de logement.",[86,2954,642],{},[86,2956,2430],{},[65,2958,2959,2962,2965,2967],{},[86,2960,2961],{},"Circuits dédiés aux gros appareils",[86,2963,2964],{},"Les gros appareils — lave-linge, sèche-linge, lave-vaisselle, taque et four — exigent chacun un circuit propre.",[86,2966,655],{},[86,2968,2430],{},[65,2970,2971,2974,2977,2979],{},[86,2972,2973],{},"Dossier de l'installation (RGIE 9.1.2)",[86,2975,2976],{},"Le dossier d’installation exige un schéma unifilaire, un plan de situation et un cartouche complet ; le PV demande des documents supplémentaires.",[86,2978,2453],{},[86,2980,2480],{},[65,2982,2983,2986,2989,2991],{},[86,2984,2985],{},"Implantation des boîtes de connexion\u002Fdérivation",[86,2987,2988],{},"Les boîtes de dérivation structurelles doivent apparaître une seule fois et de manière cohérente dans le schéma.",[86,2990,680],{},[86,2992,2480],{},[65,2994,2995,2998,3001,3003],{},[86,2996,2997],{},"Symboles électriques du plan non liés",[86,2999,3000],{},"Les appareils du plan sans lien avec la topologie électrique sont signalés à titre informatif.",[86,3002,2453],{},[86,3004,976],{},[65,3006,3007,3010,3013,3015],{},[86,3008,3009],{},"Plausibilité des groupes de commande",[86,3011,3012],{},"Contrôle de plausibilité : un groupe de commande contient au moins un interrupteur et au moins une charge commandée.",[86,3014,2453],{},[86,3016,2480],{},[31,3018,3020],{"id":3019},"ce-que-lautocontrôle-névalue-pas","Ce que l'autocontrôle n'évalue pas",[10,3022,3023],{},"Ces parties du Livre 1 restent délibérément hors du contrôle automatique :",[10,3025,3026,3029],{},[20,3027,3028],{},"Installations et locaux particuliers (Partie 7)."," Sur quatorze chapitres, PlanElec en touche trois, et chaque fois partiellement : locaux contenant une baignoire ou une douche (7.1), alimentation des véhicules routiers électriques (7.22) et installations photovoltaïques domestiques (7.112). Ne sont pas couverts : les piscines (7.2), les saunas (7.3), les installations de chantier et extérieures (7.4), les enceintes conductrices exiguës (7.6), les campings (7.8), les ports de plaisance (7.9), les installations foraines (7.11), les fontaines (7.100), les véhicules en stationnement (7.101), les atmosphères explosives (7.102) et les batteries d'accumulateurs industrielles (7.103).",[10,3031,3032,3035],{},[20,3033,3034],{},"Le côté courant continu."," Le modèle ne distingue pas les rôles de conducteur L+, L-, M, PEM et PEL. Le choix des conducteurs, les couleurs, les conducteurs de protection combinés, la sensibilité différentielle en continu, la protection du conducteur M et le contrôle permanent d'isolement en schéma IT ne sont donc pas vérifiables. Pour le photovoltaïque, cela reste du travail manuel.",[10,3037,3038,3041],{},[20,3039,3040],{},"Les dispositions transitoires des articles 59 et 69."," L'application d'une exception à une installation existante dépend de données qui ne se déduisent pas d'un schéma unifilaire — notamment la section du PEN, le début effectif des travaux sur place et la présence d'un dispositif de contrôle. PlanElec tient compte des assouplissements de la Partie 8 en présentant certains constats sur les parties existantes comme des indications plutôt que comme des erreurs, mais ne tranche pas lui-même l'exception.",[10,3043,3044,3047],{},[20,3045,3046],{},"Les contrôles des installations (Partie 6) et les prescriptions de comportement (Partie 9)"," sortent du champ d'un outil de planification. Seule la composition du dossier d'installation est vérifiée.",[31,3049,3051],{"id":3050},"ce-quun-logiciel-ne-peut-pas-établir-par-principe","Ce qu'un logiciel ne peut pas établir par principe",[10,3053,3054],{},"Même après extension du modèle, ces points resteront tributaires d'une mesure, d'un document ou d'un contrôle visuel sur place :",[746,3056,3057,3060,3063,3066,3069,3072,3075],{},[749,3058,3059],{},"le câblage réel, la continuité et la polarité des conducteurs ;",[749,3061,3062],{},"les courbes de déclenchement et l'aptitude au continu des appareils effectivement posés ;",[749,3064,3065],{},"la mesure d'isolement et le fonctionnement d'un contrôleur permanent d'isolement ;",[749,3067,3068],{},"la tenue mécanique et chimique ainsi que l'état de corrosion de la mise à la terre ;",[749,3070,3071],{},"l'efficacité de la coupure automatique et l'impédance de terre réelle ;",[749,3073,3074],{},"l'aptitude et la certification des onduleurs, batteries et composants PV ;",[749,3076,3077],{},"le zonage, l'analyse de risque et les conditions du site.",[31,3079,3081],{"id":3080},"ce-que-cela-signifie-pour-votre-contrôle","Ce que cela signifie pour votre contrôle",[10,3083,3084],{},"Utilisez l'autocontrôle pour détecter tôt les erreurs évitables : un différentiel manquant, une section qui ne correspond pas à la protection, trop de points de contact sur un circuit, un dossier incomplet. Ce sont précisément les constats qui, sinon, n'apparaissent qu'à la réception.",[10,3086,3087],{},"N'y comptez pas pour les cas énumérés ci-dessus. Votre expertise et le jugement de l'organisme agréé y restent déterminants.",{"title":781,"searchDepth":782,"depth":782,"links":3089},[3090,3100,3101,3102],{"id":2378,"depth":782,"text":2379,"children":3091},[3092,3093,3094,3095,3096,3097,3098,3099],{"id":1634,"depth":787,"text":1635},{"id":2603,"depth":787,"text":2604},{"id":2659,"depth":787,"text":2660},{"id":2727,"depth":787,"text":2728},{"id":2771,"depth":787,"text":2772},{"id":2839,"depth":787,"text":2840},{"id":2871,"depth":787,"text":2872},{"id":2915,"depth":787,"text":2916},{"id":3019,"depth":782,"text":3020},{"id":3050,"depth":782,"text":3051},{"id":3080,"depth":782,"text":3081},"La liste complète des règles vérifiées automatiquement par PlanElec — et une liste tout aussi explicite de ce que l'autocontrôle n'évalue pas.","fr",{},"\u002Fhelp\u002Fself-check-coverage.fr",{"title":2355,"description":3103},"ce-que-verifie-l-autocontrole","help\u002Fself-check-coverage.fr",[814,813,3111,3112,3113,2351],"autocontrôle","contrôle","couverture","Z5DQlp6JYzKVR97InkvOKuYnzseDlY_C4PO_HR77OU4",{"id":4,"title":5,"body":3116,"category":798,"description":799,"extension":800,"guideId":801,"locale":802,"meta":3727,"navigation":804,"order":805,"path":806,"publishedAt":807,"readTime":808,"seo":3728,"slug":810,"stem":811,"tags":3729,"updatedAt":819,"__hash__":820},{"type":7,"value":3117,"toc":3712},[3118,3120,3122,3126,3130,3132,3140,3142,3144,3310,3312,3358,3360,3416,3418,3454,3456,3512,3514,3540,3542,3578,3580,3666,3668,3670,3674,3678,3682,3686,3688,3690,3706,3708,3710],[10,3119,12],{},[10,3121,15],{},[10,3123,18,3124,23],{},[20,3125,22],{},[25,3127,3128],{},[10,3129,29],{},[31,3131,34],{"id":33},[10,3133,37,3134,41,3136,45,3138,49],{},[20,3135,40],{},[20,3137,44],{},[20,3139,48],{},[10,3141,52],{},[54,3143,57],{"id":56},[59,3145,3146,3158],{},[62,3147,3148],{},[65,3149,3150,3152,3154,3156],{},[68,3151,70],{},[68,3153,73],{},[68,3155,76],{},[68,3157,79],{},[81,3159,3160,3170,3180,3190,3200,3210,3220,3230,3240,3250,3260,3270,3280,3290,3300],{},[65,3161,3162,3164,3166,3168],{},[86,3163,88],{},[86,3165,91],{},[86,3167,94],{},[86,3169,97],{},[65,3171,3172,3174,3176,3178],{},[86,3173,102],{},[86,3175,105],{},[86,3177,108],{},[86,3179,97],{},[65,3181,3182,3184,3186,3188],{},[86,3183,115],{},[86,3185,118],{},[86,3187,121],{},[86,3189,97],{},[65,3191,3192,3194,3196,3198],{},[86,3193,128],{},[86,3195,131],{},[86,3197,134],{},[86,3199,97],{},[65,3201,3202,3204,3206,3208],{},[86,3203,141],{},[86,3205,144],{},[86,3207,121],{},[86,3209,149],{},[65,3211,3212,3214,3216,3218],{},[86,3213,154],{},[86,3215,157],{},[86,3217,108],{},[86,3219,97],{},[65,3221,3222,3224,3226,3228],{},[86,3223,166],{},[86,3225,169],{},[86,3227,172],{},[86,3229,175],{},[65,3231,3232,3234,3236,3238],{},[86,3233,180],{},[86,3235,183],{},[86,3237,186],{},[86,3239,97],{},[65,3241,3242,3244,3246,3248],{},[86,3243,193],{},[86,3245,196],{},[86,3247,199],{},[86,3249,97],{},[65,3251,3252,3254,3256,3258],{},[86,3253,206],{},[86,3255,209],{},[86,3257,121],{},[86,3259,149],{},[65,3261,3262,3264,3266,3268],{},[86,3263,218],{},[86,3265,221],{},[86,3267,108],{},[86,3269,97],{},[65,3271,3272,3274,3276,3278],{},[86,3273,230],{},[86,3275,233],{},[86,3277,236],{},[86,3279,149],{},[65,3281,3282,3284,3286,3288],{},[86,3283,243],{},[86,3285,246],{},[86,3287,121],{},[86,3289,149],{},[65,3291,3292,3294,3296,3298],{},[86,3293,255],{},[86,3295,258],{},[86,3297,261],{},[86,3299,97],{},[65,3301,3302,3304,3306,3308],{},[86,3303,268],{},[86,3305,271],{},[86,3307,274],{},[86,3309,97],{},[54,3311,280],{"id":279},[59,3313,3314,3326],{},[62,3315,3316],{},[65,3317,3318,3320,3322,3324],{},[68,3319,70],{},[68,3321,73],{},[68,3323,76],{},[68,3325,79],{},[81,3327,3328,3338,3348],{},[65,3329,3330,3332,3334,3336],{},[86,3331,301],{},[86,3333,304],{},[86,3335,307],{},[86,3337,97],{},[65,3339,3340,3342,3344,3346],{},[86,3341,314],{},[86,3343,317],{},[86,3345,320],{},[86,3347,97],{},[65,3349,3350,3352,3354,3356],{},[86,3351,327],{},[86,3353,330],{},[86,3355,121],{},[86,3357,149],{},[54,3359,338],{"id":337},[59,3361,3362,3374],{},[62,3363,3364],{},[65,3365,3366,3368,3370,3372],{},[68,3367,70],{},[68,3369,73],{},[68,3371,76],{},[68,3373,79],{},[81,3375,3376,3386,3396,3406],{},[65,3377,3378,3380,3382,3384],{},[86,3379,359],{},[86,3381,362],{},[86,3383,365],{},[86,3385,97],{},[65,3387,3388,3390,3392,3394],{},[86,3389,372],{},[86,3391,375],{},[86,3393,378],{},[86,3395,97],{},[65,3397,3398,3400,3402,3404],{},[86,3399,385],{},[86,3401,388],{},[86,3403,391],{},[86,3405,97],{},[65,3407,3408,3410,3412,3414],{},[86,3409,398],{},[86,3411,401],{},[86,3413,404],{},[86,3415,97],{},[54,3417,410],{"id":409},[59,3419,3420,3432],{},[62,3421,3422],{},[65,3423,3424,3426,3428,3430],{},[68,3425,70],{},[68,3427,73],{},[68,3429,76],{},[68,3431,79],{},[81,3433,3434,3444],{},[65,3435,3436,3438,3440,3442],{},[86,3437,431],{},[86,3439,434],{},[86,3441,437],{},[86,3443,97],{},[65,3445,3446,3448,3450,3452],{},[86,3447,444],{},[86,3449,447],{},[86,3451,121],{},[86,3453,149],{},[54,3455,455],{"id":454},[59,3457,3458,3470],{},[62,3459,3460],{},[65,3461,3462,3464,3466,3468],{},[68,3463,70],{},[68,3465,73],{},[68,3467,76],{},[68,3469,79],{},[81,3471,3472,3482,3492,3502],{},[65,3473,3474,3476,3478,3480],{},[86,3475,476],{},[86,3477,479],{},[86,3479,482],{},[86,3481,97],{},[65,3483,3484,3486,3488,3490],{},[86,3485,489],{},[86,3487,492],{},[86,3489,495],{},[86,3491,97],{},[65,3493,3494,3496,3498,3500],{},[86,3495,502],{},[86,3497,505],{},[86,3499,508],{},[86,3501,97],{},[65,3503,3504,3506,3508,3510],{},[86,3505,515],{},[86,3507,518],{},[86,3509,121],{},[86,3511,149],{},[54,3513,526],{"id":525},[59,3515,3516,3528],{},[62,3517,3518],{},[65,3519,3520,3522,3524,3526],{},[68,3521,70],{},[68,3523,73],{},[68,3525,76],{},[68,3527,79],{},[81,3529,3530],{},[65,3531,3532,3534,3536,3538],{},[86,3533,547],{},[86,3535,550],{},[86,3537,121],{},[86,3539,97],{},[54,3541,558],{"id":557},[59,3543,3544,3556],{},[62,3545,3546],{},[65,3547,3548,3550,3552,3554],{},[68,3549,70],{},[68,3551,73],{},[68,3553,76],{},[68,3555,79],{},[81,3557,3558,3568],{},[65,3559,3560,3562,3564,3566],{},[86,3561,579],{},[86,3563,582],{},[86,3565,585],{},[86,3567,97],{},[65,3569,3570,3572,3574,3576],{},[86,3571,592],{},[86,3573,595],{},[86,3575,121],{},[86,3577,97],{},[54,3579,603],{"id":602},[59,3581,3582,3594],{},[62,3583,3584],{},[65,3585,3586,3588,3590,3592],{},[68,3587,70],{},[68,3589,73],{},[68,3591,76],{},[68,3593,79],{},[81,3595,3596,3606,3616,3626,3636,3646,3656],{},[65,3597,3598,3600,3602,3604],{},[86,3599,624],{},[86,3601,627],{},[86,3603,121],{},[86,3605,149],{},[65,3607,3608,3610,3612,3614],{},[86,3609,636],{},[86,3611,639],{},[86,3613,642],{},[86,3615,97],{},[65,3617,3618,3620,3622,3624],{},[86,3619,649],{},[86,3621,652],{},[86,3623,655],{},[86,3625,97],{},[65,3627,3628,3630,3632,3634],{},[86,3629,662],{},[86,3631,665],{},[86,3633,121],{},[86,3635,149],{},[65,3637,3638,3640,3642,3644],{},[86,3639,674],{},[86,3641,677],{},[86,3643,680],{},[86,3645,149],{},[65,3647,3648,3650,3652,3654],{},[86,3649,687],{},[86,3651,690],{},[86,3653,121],{},[86,3655,175],{},[65,3657,3658,3660,3662,3664],{},[86,3659,699],{},[86,3661,702],{},[86,3663,121],{},[86,3665,149],{},[31,3667,710],{"id":709},[10,3669,713],{},[10,3671,3672,719],{},[20,3673,718],{},[10,3675,3676,725],{},[20,3677,724],{},[10,3679,3680,731],{},[20,3681,730],{},[10,3683,3684,737],{},[20,3685,736],{},[31,3687,741],{"id":740},[10,3689,744],{},[746,3691,3692,3694,3696,3698,3700,3702,3704],{},[749,3693,751],{},[749,3695,754],{},[749,3697,757],{},[749,3699,760],{},[749,3701,763],{},[749,3703,766],{},[749,3705,769],{},[31,3707,773],{"id":772},[10,3709,776],{},[10,3711,779],{},{"title":781,"searchDepth":782,"depth":782,"links":3713},[3714,3724,3725,3726],{"id":33,"depth":782,"text":34,"children":3715},[3716,3717,3718,3719,3720,3721,3722,3723],{"id":56,"depth":787,"text":57},{"id":279,"depth":787,"text":280},{"id":337,"depth":787,"text":338},{"id":409,"depth":787,"text":410},{"id":454,"depth":787,"text":455},{"id":525,"depth":787,"text":526},{"id":557,"depth":787,"text":558},{"id":602,"depth":787,"text":603},{"id":709,"depth":782,"text":710},{"id":740,"depth":782,"text":741},{"id":772,"depth":782,"text":773},{},{"title":5,"description":799},[813,814,815,816,817,818],[3731,4003,4267,4585,5200,5386,5547],{"id":3732,"title":3733,"body":3734,"category":3985,"description":3986,"extension":800,"guideId":3987,"locale":802,"meta":3988,"navigation":804,"order":3989,"path":3990,"publishedAt":3991,"readTime":3992,"seo":3993,"slug":3994,"stem":3995,"tags":3996,"updatedAt":3991,"__hash__":4002},"help\u002Fhelp\u002Fgetting-started.nl.md","Aan de slag: van project tot eerste export",{"type":7,"value":3735,"toc":3976},[3736,3739,3744,3750,3754,3761,3764,3781,3784,3792,3796,3807,3810,3813,3816,3831,3836,3840,3843,3846,3849,3856,3864,3868,3871,3874,3891,3894,3899,3903,3906,3909,3912,3920,3924,3931,3934,3942,3946,3949,3969],[10,3737,3738],{},"PlanElec gebruikt één projectmodel voor het grondplan, de elektrische topologie, de verdeelkast en de documenten. Daardoor werkt u het best in een vaste volgorde: eerst de ruimte en toestellen vastleggen, daarna de elektrische structuur controleren en pas dan exporteren.",[25,3740,3741],{},[10,3742,3743],{},"Gebruikt u PlanElec als eigenaar of bouwheer? Laat keuzes en documenten vóór uitvoering en keuring nakijken door een gekwalificeerde elektricien.",[10,3745,3746],{},[3747,3748],"a",{"id":3749},"project",[31,3751,3753],{"id":3752},"_1-maak-het-project-aan","1. Maak het project aan",[10,3755,3756,3757,3760],{},"Kies in het projectoverzicht ",[20,3758,3759],{},"Project aanmaken",". U kunt starten met de begeleide workflow, een gelokaliseerde projecttemplate of een leeg project.",[10,3762,3763],{},"Vul minstens een herkenbare projectnaam in. In de projectgegevens kunt u later ook deze gegevens bewaren:",[746,3765,3766,3769,3772,3775,3778],{},[749,3767,3768],{},"klant en contactgegevens;",[749,3770,3771],{},"installatieadres;",[749,3773,3774],{},"installateur en eventueel logo;",[749,3776,3777],{},"EAN, installatie- en stroomtype;",[749,3779,3780],{},"erkend controleorganisme en projectnotities.",[10,3782,3783],{},"Deze gegevens worden hergebruikt in titelblokken, het zelfcontrolerapport en het werkdossier. Ontbrekende gegevens blokkeren uitproberen en conceptdownloads niet, maar controleer ze voordat u documenten deelt.",[10,3785,3786,3789],{},[3747,3787],{"id":3788},"floorplan",[3747,3790],{"id":3791},"situation-plan",[31,3793,3795],{"id":3794},"_2-teken-het-grondplan-en-bouw-het-situatieplan-op","2. Teken het grondplan en bouw het situatieplan op",[10,3797,3798,3799,3802,3803,3806],{},"Maak eerst een verdieping aan. Teken daarna de buiten- en binnenmuren met het veelhoek-, rechthoek- of lijnwerktuig. Gesloten wandvlakken worden als ruimtes herkend; geef elke ruimte een duidelijke naam, zoals ",[20,3800,3801],{},"Keuken"," of ",[20,3804,3805],{},"Slaapkamer 1",".",[10,3808,3809],{},"Hebt u al een plan als afbeelding, dan kunt u dat als referentie gebruiken. Kalibreer het met een bekende maat voordat u nauwkeurig plaatst. De afbeelding is een onderlegger: muren, openingen en elektrische punten blijven afzonderlijke projectgegevens.",[10,3811,3812],{},"Plaats vervolgens deuren, ramen, trappen en de elektrische symbolen op hun werkelijke locatie. Het resulterende grondplan vormt de basis van het situatieschema dat u later als PDF exporteert.",[10,3814,3815],{},"Praktische controle:",[3817,3818,3819,3822,3825,3828],"ol",{},[749,3820,3821],{},"Zijn alle verdiepingen en ruimtes aanwezig en benoemd?",[749,3823,3824],{},"Staan stopcontacten, schakelaars, lichtpunten en vaste toestellen in de juiste ruimte?",[749,3826,3827],{},"Is de verdeelkast op het plan geplaatst?",[749,3829,3830],{},"Zijn eventuele badkamerzones en bijzondere toestellen correct vastgelegd?",[10,3832,3833],{},[3747,3834],{"id":3835},"devices",[31,3837,3839],{"id":3838},"_3-plaats-en-verbind-elektrische-punten","3. Plaats en verbind elektrische punten",[10,3841,3842],{},"Open het symbolenpalet en plaats de nodige elektrische punten. Sommige hulpmiddelen kunnen voorstellen maken voor stopcontacten, verlichting, standaardtoestellen of een spotraster. Beoordeel en pas die voorstellen aan: ze vervangen uw keuze van aantallen en posities niet.",[10,3844,3845],{},"Koppel schakelaars en lichtpunten in schakelketens. Voor vrije schakelaars en lichten in een ruimte kan PlanElec een keten voorstellen; de volgorde blijft manueel aanpasbaar.",[10,3847,3848],{},"Een symbool op het grondplan en een elektrisch knooppunt horen bij elkaar, maar zijn niet hetzelfde. Controleer daarom onverbonden componenten. Zonder geldige topologie kan een toestel niet betrouwbaar in een stroomkring, kabel- of materiaallijst terechtkomen.",[10,3850,3851,3852,3806],{},"Meer over automatische voorstellen, kabels en stroomkringen leest u in ",[3747,3853,3855],{"href":3854},"\u002Fhelp\u002Fautomatische-planning","Automatische planning gebruiken",[10,3857,3858,3861],{},[3747,3859],{"id":3860},"automatic-planning",[3747,3862],{"id":3863},"cabinet",[31,3865,3867],{"id":3866},"_4-controleer-de-elektrische-topologie-en-verdeelkast","4. Controleer de elektrische topologie en verdeelkast",[10,3869,3870],{},"Gebruik de automatische stroomkringtoewijzing als startvoorstel. PlanElec groepeert standaardverbruikers, maakt voor bijzondere toestellen waar nodig een aparte beveiliging aan en kan lasten over fasen verdelen. Bekijk de preview voordat u de toewijzing toepast.",[10,3872,3873],{},"Open daarna de verdeelkasteditor. Automatisch vullen plaatst bestaande hoofdschakelaars, differentieelschakelaars en automaten op de DIN-rails en houdt ruimte vrij. Controleer vervolgens:",[746,3875,3876,3879,3882,3885,3888],{},[749,3877,3878],{},"de beveiligingsketen en de toegewezen verbruikers;",[749,3880,3881],{},"kabeltype, doorsnede en route;",[749,3883,3884],{},"RCD-groepen en aantallen stroomkringen;",[749,3886,3887],{},"faseverdeling bij een meerfasige installatie;",[749,3889,3890],{},"vrije moduleplaatsen en de werkelijke kastafmetingen.",[10,3892,3893],{},"Alle automatische resultaten blijven bewerkbaar. Een voorstel is geen ontwerpbeslissing of materiaalbestelling.",[10,3895,3896],{},[3747,3897],{"id":3898},"schema",[31,3900,3902],{"id":3901},"_5-bekijk-het-eendraadschema-en-de-zelfcontrole","5. Bekijk het eendraadschema en de zelfcontrole",[10,3904,3905],{},"Het eendraadschema wordt uit dezelfde elektrische topologie opgebouwd. Controleer circuitnamen, beveiligingen, kabelgegevens, verbindingen en symbolen. Los fouten en waarschuwingen op die PlanElec met de beschikbare projectgegevens kan herkennen.",[10,3907,3908],{},"De AREI\u002FRGIE-zelfcontrole ondersteunt een gedocumenteerd deel van de softwarematig controleerbare regels. Een foutloze run betekent alleen dat binnen die ondersteunde regels geen fout is gevonden. Metingen, omstandigheden ter plaatse en niet gemodelleerde regels vallen buiten deze controle.",[10,3910,3911],{},"PlanElec levert dus geen conformiteitsattest en vervangt geen officiële keuring door een erkend controleorganisme.",[10,3913,3914,3917],{},[3747,3915],{"id":3916},"export",[3747,3918],{"id":3919},"exports",[31,3921,3923],{"id":3922},"_6-exporteer-en-beoordeel-de-documenten","6. Exporteer en beoordeel de documenten",[10,3925,3926,3927,3930],{},"In ",[20,3928,3929],{},"Export"," kunt u onder andere het eendraadschema en het situatieschema als PDF genereren. Ook het zelfcontrolerapport en lijsten voor stroomkringen, kabels en materiaal zijn centraal beschikbaar; de gedetailleerde lijsten bevinden zich nog in de pilotworkflow.",[10,3932,3933],{},"U kunt geselecteerde documenten ook samenvoegen tot een werkdossier met voorblad, inhoudsoverzicht en doorlopende paginanummering. Bekijk vóór delen iedere pagina en controleer de projectmetadata.",[10,3935,3936,3937,3941],{},"Zie ",[3747,3938,3940],{"href":3939},"\u002Fhelp\u002Fdocumenten-exporteren","Documenten exporteren"," voor de volledige lijst, statussen en beperkingen.",[31,3943,3945],{"id":3944},"een-bruikbare-eerste-mijlpaal","Een bruikbare eerste mijlpaal",[10,3947,3948],{},"Uw eerste project is goed opgebouwd wanneer:",[746,3950,3951,3954,3957,3960,3963,3966],{},[749,3952,3953],{},"ruimtes en elektrische punten op het situatieplan staan;",[749,3955,3956],{},"alle relevante punten met de elektrische topologie verbonden zijn;",[749,3958,3959],{},"stroomkringen, kabels en kastindeling zijn beoordeeld;",[749,3961,3962],{},"het eendraadschema leesbaar is;",[749,3964,3965],{},"de zelfcontrole is uitgevoerd en resterende bevindingen begrepen zijn;",[749,3967,3968],{},"geëxporteerde documenten visueel en inhoudelijk zijn nagekeken.",[10,3970,3971,3972,3806],{},"Wilt u meteen beginnen? ",[3747,3973,3975],{"href":3974},"\u002Fauth\u002Fregister","Maak gratis een Early Access-account aan",{"title":781,"searchDepth":782,"depth":782,"links":3977},[3978,3979,3980,3981,3982,3983,3984],{"id":3752,"depth":782,"text":3753},{"id":3794,"depth":782,"text":3795},{"id":3838,"depth":782,"text":3839},{"id":3866,"depth":782,"text":3867},{"id":3901,"depth":782,"text":3902},{"id":3922,"depth":782,"text":3923},{"id":3944,"depth":782,"text":3945},"getting_started","Bouw stap voor stap een PlanElec-project op: projectgegevens, grondplan, ruimtes, elektrische punten, verdeelkast, schema en export.","getting-started",{},1,"\u002Fhelp\u002Fgetting-started.nl","2026-07-20","8 min",{"title":3733,"description":3986},"aan-de-slag","help\u002Fgetting-started.nl",[3749,3997,3998,3999,4000,4001,3916],"grondplan","situatieplan","verbruikers","verdeelkast","eendraadschema","y0YexoIxq6iYFBoXVtIjfQB52kgGtd0zn6eLhTijPD8",{"id":4004,"title":4005,"body":4006,"category":4252,"description":4253,"extension":800,"guideId":3860,"locale":802,"meta":4254,"navigation":804,"order":782,"path":4255,"publishedAt":3991,"readTime":4256,"seo":4257,"slug":4258,"stem":4259,"tags":4260,"updatedAt":3991,"__hash__":4266},"help\u002Fhelp\u002Fautomatic-planning.nl.md","Automatische planning gebruiken en controleren",{"type":7,"value":4007,"toc":4242},[4008,4011,4017,4026,4030,4033,4036,4053,4056,4060,4063,4066,4071,4075,4078,4081,4084,4098,4101,4106,4110,4113,4133,4136,4141,4145,4148,4151,4155,4159,4162,4165,4179,4182,4189,4193,4196,4234,4237],[10,4009,4010],{},"De automatische functies van PlanElec zijn bedoeld als bewerkbare voorstellen. Ze nemen repetitief werk over, maar kunnen niet weten welke toestellen werkelijk worden geïnstalleerd, hoe een kabel op de werf loopt of welke productspecificaties uw elektricien kiest.",[10,4012,4013,4014,3806],{},"Werk daarom steeds volgens hetzelfde patroon: ",[20,4015,4016],{},"voorstel maken → preview controleren → toepassen → technisch nakijken",[10,4018,4019,4021,4024],{},[3747,4020],{"id":3860},[3747,4022],{"id":4023},"consumers",[3747,4025],{"id":3835},[31,4027,4029],{"id":4028},"verbruikers-en-lichtpunten-voorstellen","Verbruikers en lichtpunten voorstellen",[10,4031,4032],{},"In het grondplan zijn hulpmiddelen beschikbaar voor automatische stopcontacten, verlichting, standaarduitrusting en spotrasters. De voorstellen gebruiken de getekende ruimtes en geometrie als basis.",[10,4034,4035],{},"Voor een bruikbaar resultaat:",[3817,4037,4038,4041,4044,4047,4050],{},[749,4039,4040],{},"teken gesloten en correct benoemde ruimtes;",[749,4042,4043],{},"stel waar nodig het gewenste aantal of patroon in;",[749,4045,4046],{},"bekijk de voorgestelde posities;",[749,4048,4049],{},"verplaats, voeg toe of verwijder punten volgens het echte ontwerp;",[749,4051,4052],{},"controleer bijzondere zones en vaste toestellen afzonderlijk.",[10,4054,4055],{},"PlanElec voegt niet stilzwijgend ontbrekende toestellen toe. U blijft verantwoordelijk voor het programma van eisen en de uiteindelijke plaatsing.",[54,4057,4059],{"id":4058},"schakelketens-automatisch-opbouwen","Schakelketens automatisch opbouwen",[10,4061,4062],{},"Voor vrije schakelaars en lichtpunten binnen één ruimte kan PlanElec een schakelketen voorstellen. Het startpunt is normaal de vrije schakelaar die het dichtst bij een deur ligt; daarna worden nabijgelegen vrije punten gekoppeld.",[10,4064,4065],{},"Controleer altijd welke schakelaar welk licht bedient en pas de volgorde manueel aan wanneer de werkelijke bediening anders is.",[10,4067,4068],{},[3747,4069],{"id":4070},"cables",[31,4072,4074],{"id":4073},"kabelspecificaties-en-routes-genereren","Kabelspecificaties en routes genereren",[10,4076,4077],{},"Zodra de elektrische topologie bestaat, kan PlanElec voor iedere ouder-kindverbinding een kabelsegment aanmaken. Een echte verbindings- of aftakdoos splitst de verbinding in afzonderlijke segmenten. Een doos die alleen in de buurt staat, wordt niet automatisch elektrisch in het pad opgenomen.",[10,4079,4080],{},"De automatische routering zoekt per verdieping een korte route langs de getekende muren. Zijn start en einde niet via dezelfde wandcomponent bereikbaar, dan gebruikt de router een directe fallback.",[10,4082,4083],{},"Na het routeren:",[746,4085,4086,4089,4092,4095],{},[749,4087,4088],{},"controleer of de route overeenkomt met de beoogde uitvoering;",[749,4090,4091],{},"voeg of verplaats routepunten waar nodig;",[749,4093,4094],{},"controleer kabeltype, doorsnede en installatiewijze;",[749,4096,4097],{},"vul een manuele lengte in wanneer de berekende route de werkelijkheid niet voldoende benadert.",[10,4099,4100],{},"De berekende lengte voedt de materiaallijst, spanningsvalberekening en validatie. Ze is een nettolengte zonder automatisch snijverlies of reservepercentage.",[10,4102,4103],{},[3747,4104],{"id":4105},"circuits",[31,4107,4109],{"id":4108},"verbruikers-automatisch-aan-stroomkringen-toewijzen","Verbruikers automatisch aan stroomkringen toewijzen",[10,4111,4112],{},"De automatische stroomkringtoewijzing maakt een voorstel op basis van de vastgelegde verbruikers en productregels. Onder meer deze keuzes worden ondersteund:",[746,4114,4115,4118,4121,4124,4127,4130],{},[749,4116,4117],{},"standaard licht- en stopcontactpunten worden per ruimte gegroepeerd;",[749,4119,4120],{},"maximaal acht aansluitpunten worden per standaardkring voorzien;",[749,4122,4123],{},"onder andere kookplaat, oven, wasmachine, droogkast, vaatwasser, boiler, warmtepomp en sauna krijgen een toegewijde automaat;",[749,4125,4126],{},"standaardgroepen worden achter 30 mA-differentieelschakelaars geplaatst;",[749,4128,4129],{},"een wallbox krijgt een afzonderlijke 30 mA-RCD en een driefasige automaat; bij gedocumenteerde ingebouwde 6 mA-DC-detectie stelt PlanElec extern type A voor, anders type B;",[749,4131,4132],{},"bij meerdere verdeelkasten kan de toewijzing over boards worden verdeeld.",[10,4134,4135],{},"Bekijk de preview voor u bevestigt. Controleer vooral gemengde kringen, bijzondere toestellen, bestaande handmatige toewijzingen en de toepasbaarheid van de defaults op het concrete project.",[10,4137,4138],{},[3747,4139],{"id":4140},"phases",[31,4142,4144],{"id":4143},"lasten-over-fasen-verdelen","Lasten over fasen verdelen",[10,4146,4147],{},"Voor een driefasig of delta-net kan PlanElec lasten over L1, L2 en L3 verdelen. De faseweergave toont de berekende last per fase en waarschuwt bij een duidelijke onbalans.",[10,4149,4150],{},"Dit blijft een modelberekening op basis van de ingevoerde vermogens. Werkelijke gelijktijdigheid, metingen en netvoorwaarden moeten buiten de software worden beoordeeld.",[10,4152,4153],{},[3747,4154],{"id":3863},[31,4156,4158],{"id":4157},"de-verdeelkast-automatisch-vullen","De verdeelkast automatisch vullen",[10,4160,4161],{},"Automatisch vullen plaatst de bestaande hoofdschakelaar, RCD's en MCB's op vrije DIN-railplaatsen. De standaardvolgorde is hoofd-RCD, groeps-RCD's en vervolgens automaten. De functie houdt standaard ongeveer twintig procent railruimte vrij.",[10,4163,4164],{},"Het verschil met stroomkringtoewijzing is belangrijk:",[746,4166,4167,4173],{},[749,4168,4169,4172],{},[20,4170,4171],{},"Stroomkringtoewijzing"," maakt en koppelt de elektrische beveiligingsstructuur.",[749,4174,4175,4178],{},[20,4176,4177],{},"Automatisch vullen"," rangschikt die bestaande modules fysiek in de kast.",[10,4180,4181],{},"Na automatisch vullen controleert u de gekozen kastgrootte, TE-breedtes, reservecapaciteit, beschermingsketens en verbindingspaden. Expliciete paden via verbindingsdozen worden bij opnieuw vullen bewaard.",[10,4183,4184,4186],{},[3747,4185],{"id":3898},[3747,4187],{"id":4188},"review",[31,4190,4192],{"id":4191},"eindcontrole-van-een-automatisch-voorstel","Eindcontrole van een automatisch voorstel",[10,4194,4195],{},"Loop na elke automatische actie deze punten na:",[3817,4197,4198,4204,4210,4216,4222,4228],{},[749,4199,4200,4203],{},[20,4201,4202],{},"Volledigheid:"," zijn alle werkelijke verbruikers, dozen en verdeelkasten gemodelleerd?",[749,4205,4206,4209],{},[20,4207,4208],{},"Topologie:"," klopt elke ouder-kindverbinding en is niets onverbonden?",[749,4211,4212,4215],{},[20,4213,4214],{},"Beveiliging:"," passen RCD, MCB, poolconfiguratie en kabel bij de toepassing?",[749,4217,4218,4221],{},[20,4219,4220],{},"Ruimte:"," zijn routes en posities uitvoerbaar op de werf?",[749,4223,4224,4227],{},[20,4225,4226],{},"Fasen:"," is de verdeling aannemelijk met de ingevoerde vermogens?",[749,4229,4230,4233],{},[20,4231,4232],{},"Documenten:"," blijven situatieplan en eendraadschema na de wijzigingen leesbaar?",[10,4235,4236],{},"De AREI\u002FRGIE-zelfcontrole helpt bij de ondersteunde, op basis van projectdata beslisbare regels. Ze is geen conformiteitsverklaring en vervangt de beoordeling door een elektricien of een officiële keuring niet.",[10,4238,4239,4240,3806],{},"Ga daarna verder met ",[3747,4241,3940],{"href":3939},{"title":781,"searchDepth":782,"depth":782,"links":4243},[4244,4247,4248,4249,4250,4251],{"id":4028,"depth":782,"text":4029,"children":4245},[4246],{"id":4058,"depth":787,"text":4059},{"id":4073,"depth":782,"text":4074},{"id":4108,"depth":782,"text":4109},{"id":4143,"depth":782,"text":4144},{"id":4157,"depth":782,"text":4158},{"id":4191,"depth":782,"text":4192},"automation","Gebruik PlanElec-voorstellen voor verbruikers, schakelketens, kabelroutes, stroomkringen, fasen en de verdeelkast zonder de technische controle over te slaan.",{},"\u002Fhelp\u002Fautomatic-planning.nl","9 min",{"title":4005,"description":4253},"automatische-planning","help\u002Fautomatic-planning.nl",[4261,3999,4262,4263,4264,4000,4265],"automatische planning","kabelroute","stroomkring","faseverdeling","DIN-rail","YYloXt8Ku2ew2gXNJSN6HIK4S1nkSgIWDZ1eZxMbb88",{"id":4268,"title":4269,"body":4270,"category":3919,"description":4570,"extension":800,"guideId":4571,"locale":802,"meta":4572,"navigation":804,"order":787,"path":4573,"publishedAt":3991,"readTime":3992,"seo":4574,"slug":4575,"stem":4576,"tags":4577,"updatedAt":3991,"__hash__":4584},"help\u002Fhelp\u002Fdocument-exports.nl.md","Documenten exporteren en een werkdossier samenstellen",{"type":7,"value":4271,"toc":4559},[4272,4275,4279,4283,4365,4372,4376,4379,4382,4399,4403,4407,4410,4413,4417,4420,4423,4426,4440,4444,4447,4467,4470,4477,4480,4488,4493,4497,4500,4503,4508,4512,4515,4538,4541,4545,4548],[10,4273,4274],{},"De exportwerkruimte brengt de documenten uit hetzelfde projectmodel samen. U kunt documenten afzonderlijk downloaden of geselecteerde onderdelen bundelen in één werkdossier.",[10,4276,4277],{},[3747,4278],{"id":3919},[31,4280,4282],{"id":4281},"status-in-één-oogopslag","Status in één oogopslag",[59,4284,4285,4298],{},[62,4286,4287],{},[65,4288,4289,4292,4295],{},[68,4290,4291],{},"Document",[68,4293,4294],{},"Huidige status",[68,4296,4297],{},"Belangrijk om te weten",[81,4299,4300,4311,4321,4332,4343,4354],{},[65,4301,4302,4305,4308],{},[86,4303,4304],{},"Eendraadschema PDF",[86,4306,4307],{},"Beschikbaar",[86,4309,4310],{},"Meerdere pagina's mogelijk; controleer schaal, symbolen en titelblok.",[65,4312,4313,4316,4318],{},[86,4314,4315],{},"Situatieschema PDF",[86,4317,4307],{},[86,4319,4320],{},"Gebaseerd op het getekende grondplan en de geplaatste symbolen.",[65,4322,4323,4326,4329],{},[86,4324,4325],{},"AREI\u002FRGIE-zelfcontrolerapport",[86,4327,4328],{},"Beschikbaar, adviserend",[86,4330,4331],{},"Geen conformiteitsattest en geen vervanging voor de officiële keuring.",[65,4333,4334,4337,4340],{},[86,4335,4336],{},"Stroomkring-, kabel- en materiaallijst",[86,4338,4339],{},"Pilotworkflow",[86,4341,4342],{},"Modelgebaseerde, fabrikantneutrale lijsten; nog geen bestellingsvrijgave.",[65,4344,4345,4348,4351],{},[86,4346,4347],{},"Verdeelkast-PDF",[86,4349,4350],{},"Feature-flag",[86,4352,4353],{},"Alleen zichtbaar wanneer de functie actief is en kastgegevens aanwezig zijn.",[65,4355,4356,4359,4362],{},[86,4357,4358],{},"Samengevoegd installatiedossier",[86,4360,4361],{},"Pilot\u002Fwerkstatus",[86,4363,4364],{},"Lokale samenstelling; een versioneerbare finale serversnapshot en formele acceptatie blijven open.",[10,4366,4367,4369],{},[3747,4368],{"id":3898},[3747,4370],{"id":4371},"single-line",[31,4373,4375],{"id":4374},"eendraadschema-als-pdf","Eendraadschema als PDF",[10,4377,4378],{},"Het eendraadschema gebruikt de elektrische topologie, beveiligingstoestellen, stroomkringen, kabelgegevens en verbruikers. Grotere installaties worden over meerdere pagina's verdeeld.",[10,4380,4381],{},"Controleer vóór downloaden:",[746,4383,4384,4387,4390,4393,4396],{},[749,4385,4386],{},"of elk verbruikerpad bij de juiste automaat en RCD uitkomt;",[749,4388,4389],{},"of kabeltype, doorsnede en labels ingevuld zijn;",[749,4391,4392],{},"of reservemodules niet als actieve stroomkring verschijnen;",[749,4394,4395],{},"of project- en installateurgegevens in het titelblok kloppen;",[749,4397,4398],{},"of geen inhoud aan een paginarand wordt afgesneden.",[10,4400,4401],{},[3747,4402],{"id":3791},[31,4404,4406],{"id":4405},"situatieschema-als-pdf","Situatieschema als PDF",[10,4408,4409],{},"Het situatieschema toont de getekende ruimtes, openingen en elektrische symbolen op hun locatie. Controleer alle verdiepingen afzonderlijk en let op overlappende labels, ontbrekende apparaten en de leesbaarheid op het gekozen A4- of A3-formaat.",[10,4411,4412],{},"Het situatieschema en eendraadschema delen projectnotities en andere titelblokgegevens. Corrigeer die gegevens in het project in plaats van afzonderlijk in een PDF.",[10,4414,4415],{},[3747,4416],{"id":2348},[31,4418,4325],{"id":4419},"areirgie-zelfcontrolerapport",[10,4421,4422],{},"Het rapport vat de bevindingen samen die PlanElec met de ingevoerde gegevens en de ondersteunde regels kan beoordelen. Het vermeldt ook wanneer een controle niet gestart, onvolledig of buiten de huidige dekking valt.",[10,4424,4425],{},"Een rapport zonder gevonden fout betekent niet dat de installatie AREI\u002FRGIE-conform is. Metingen, bewijsstukken, omstandigheden ter plaatse en niet gemodelleerde regels vallen buiten een softwarecontrole. Alleen een erkend controleorganisme voert de officiële keuring uit.",[10,4427,4428,4431,4434,4437],{},[3747,4429],{"id":4430},"lists",[3747,4432],{"id":4433},"circuit-list",[3747,4435],{"id":4436},"cable-list",[3747,4438],{"id":4439},"material-list",[31,4441,4443],{"id":4442},"stroomkring-kabel-en-materiaallijsten","Stroomkring-, kabel- en materiaallijsten",[10,4445,4446],{},"Deze lijsten zijn in de centrale pilotworkflow beschikbaar:",[746,4448,4449,4455,4461],{},[749,4450,4451,4454],{},[20,4452,4453],{},"Stroomkringenlijst:"," overzicht van de gemodelleerde kringen en beveiligingen.",[749,4456,4457,4460],{},[20,4458,4459],{},"Kabellijst:"," kabelsegmenten met specificatie en berekende of manuele lengte.",[749,4462,4463,4466],{},[20,4464,4465],{},"Materiaallijst:"," fabrikantneutrale hoeveelheden voor onder meer schakelmateriaal, aansluitingen, bescherming, kast, accessoires en nettokabellengtes.",[10,4468,4469],{},"De materiaallijst kan per categorie of ruimte worden bekeken en maakt standaardaannames zichtbaar. Ze bevat geen prijzen of concrete fabrikantartikelen. Nettokabellengtes hebben geen automatisch snijverlies- of reservepercentage. Gebruik de lijst daarom als controle- en offertestartpunt, niet als bestelbon.",[10,4471,4472,4474],{},[3747,4473],{"id":3863},[3747,4475],{"id":4476},"cabinet-pdf",[31,4478,4347],{"id":4479},"verdeelkast-pdf",[10,4481,4482,4483,4487],{},"De PDF-weergave van de verdeelkast is alleen beschikbaar wanneer de ",[4484,4485,4486],"code",{},"cabinet_export","-feature-flag actief is en het project kastgegevens bevat. Als de optie ontbreekt, is dat geen exportfout: de functie is dan niet voor die omgeving vrijgegeven.",[10,4489,4490],{},[3747,4491],{"id":4492},"dossier",[31,4494,4496],{"id":4495},"een-installatiedossier-samenstellen","Een installatiedossier samenstellen",[10,4498,4499],{},"In de dossier-builder selecteert u de gewenste documenten. PlanElec maakt lokaal een voorblad, documentoverzicht en doorlopende paginanummering en voegt de geselecteerde PDF's in een vaste volgorde samen.",[10,4501,4502],{},"Dit is momenteel een werk- en controlestatus. De versioneerbare serversnapshot en formeel beoordeelde praktijkoutputs die voor een finaal dossier nodig zijn, zijn nog niet algemeen vrijgegeven.",[10,4504,4505],{},[3747,4506],{"id":4507},"metadata",[31,4509,4511],{"id":4510},"projectmetadata-controleren","Projectmetadata controleren",[10,4513,4514],{},"Open vanuit de export de projectgegevens en controleer minstens:",[3817,4516,4517,4520,4523,4526,4529,4532,4535],{},[749,4518,4519],{},"klant en installatieadres;",[749,4521,4522],{},"installateur en contactgegevens;",[749,4524,4525],{},"controleorganisme;",[749,4527,4528],{},"Belgische EAN;",[749,4530,4531],{},"woon- of niet-wooninstallatie en AC\u002FDC-aanduiding;",[749,4533,4534],{},"planformaat, revisie en projectnotities;",[749,4536,4537],{},"logo, indien gebruikt.",[10,4539,4540],{},"Een ongeldige EAN wordt niet als geldige nummering uitgevoerd, maar blokkeert in Early Access de download niet automatisch.",[31,4542,4544],{"id":4543},"laatste-controle-vóór-delen","Laatste controle vóór delen",[10,4546,4547],{},"Open het gedownloade bestand buiten PlanElec en bekijk elke pagina. Controleer paginavolgorde, leesbaarheid, metadata, waarschuwingen en ontbrekende onderdelen. Bewaar de projectversie waarmee het document is gemaakt en laat het resultaat beoordelen door de verantwoordelijke elektricien.",[10,4549,4550,4551,4555,4556,3806],{},"Wilt u eerst het projectmodel nalopen? Begin bij ",[3747,4552,4554],{"href":4553},"\u002Fhelp\u002Faan-de-slag","Aan de slag"," of lees hoe u ",[3747,4557,4558],{"href":3854},"automatische planning controleert",{"title":781,"searchDepth":782,"depth":782,"links":4560},[4561,4562,4563,4564,4565,4566,4567,4568,4569],{"id":4281,"depth":782,"text":4282},{"id":4374,"depth":782,"text":4375},{"id":4405,"depth":782,"text":4406},{"id":4419,"depth":782,"text":4325},{"id":4442,"depth":782,"text":4443},{"id":4479,"depth":782,"text":4347},{"id":4495,"depth":782,"text":4496},{"id":4510,"depth":782,"text":4511},{"id":4543,"depth":782,"text":4544},"Bekijk welke PDF-documenten PlanElec maakt, welke outputs beschikbaar of pilot zijn en wat u vóór delen of keuring moet controleren.","document-exports",{},"\u002Fhelp\u002Fdocument-exports.nl",{"title":4269,"description":4570},"documenten-exporteren","help\u002Fdocument-exports.nl",[4578,4001,4579,815,4580,4581,4582,4583],"PDF-export","situatieschema","stroomkringen","kabellijst","materiaallijst","installatiedossier","wAYpphMgOzBVC15J3rkGcyxue3AcUx9lzOZLAuIlp0Y",{"id":4,"title":5,"body":4586,"category":798,"description":799,"extension":800,"guideId":801,"locale":802,"meta":5197,"navigation":804,"order":805,"path":806,"publishedAt":807,"readTime":808,"seo":5198,"slug":810,"stem":811,"tags":5199,"updatedAt":819,"__hash__":820},{"type":7,"value":4587,"toc":5182},[4588,4590,4592,4596,4600,4602,4610,4612,4614,4780,4782,4828,4830,4886,4888,4924,4926,4982,4984,5010,5012,5048,5050,5136,5138,5140,5144,5148,5152,5156,5158,5160,5176,5178,5180],[10,4589,12],{},[10,4591,15],{},[10,4593,18,4594,23],{},[20,4595,22],{},[25,4597,4598],{},[10,4599,29],{},[31,4601,34],{"id":33},[10,4603,37,4604,41,4606,45,4608,49],{},[20,4605,40],{},[20,4607,44],{},[20,4609,48],{},[10,4611,52],{},[54,4613,57],{"id":56},[59,4615,4616,4628],{},[62,4617,4618],{},[65,4619,4620,4622,4624,4626],{},[68,4621,70],{},[68,4623,73],{},[68,4625,76],{},[68,4627,79],{},[81,4629,4630,4640,4650,4660,4670,4680,4690,4700,4710,4720,4730,4740,4750,4760,4770],{},[65,4631,4632,4634,4636,4638],{},[86,4633,88],{},[86,4635,91],{},[86,4637,94],{},[86,4639,97],{},[65,4641,4642,4644,4646,4648],{},[86,4643,102],{},[86,4645,105],{},[86,4647,108],{},[86,4649,97],{},[65,4651,4652,4654,4656,4658],{},[86,4653,115],{},[86,4655,118],{},[86,4657,121],{},[86,4659,97],{},[65,4661,4662,4664,4666,4668],{},[86,4663,128],{},[86,4665,131],{},[86,4667,134],{},[86,4669,97],{},[65,4671,4672,4674,4676,4678],{},[86,4673,141],{},[86,4675,144],{},[86,4677,121],{},[86,4679,149],{},[65,4681,4682,4684,4686,4688],{},[86,4683,154],{},[86,4685,157],{},[86,4687,108],{},[86,4689,97],{},[65,4691,4692,4694,4696,4698],{},[86,4693,166],{},[86,4695,169],{},[86,4697,172],{},[86,4699,175],{},[65,4701,4702,4704,4706,4708],{},[86,4703,180],{},[86,4705,183],{},[86,4707,186],{},[86,4709,97],{},[65,4711,4712,4714,4716,4718],{},[86,4713,193],{},[86,4715,196],{},[86,4717,199],{},[86,4719,97],{},[65,4721,4722,4724,4726,4728],{},[86,4723,206],{},[86,4725,209],{},[86,4727,121],{},[86,4729,149],{},[65,4731,4732,4734,4736,4738],{},[86,4733,218],{},[86,4735,221],{},[86,4737,108],{},[86,4739,97],{},[65,4741,4742,4744,4746,4748],{},[86,4743,230],{},[86,4745,233],{},[86,4747,236],{},[86,4749,149],{},[65,4751,4752,4754,4756,4758],{},[86,4753,243],{},[86,4755,246],{},[86,4757,121],{},[86,4759,149],{},[65,4761,4762,4764,4766,4768],{},[86,4763,255],{},[86,4765,258],{},[86,4767,261],{},[86,4769,97],{},[65,4771,4772,4774,4776,4778],{},[86,4773,268],{},[86,4775,271],{},[86,4777,274],{},[86,4779,97],{},[54,4781,280],{"id":279},[59,4783,4784,4796],{},[62,4785,4786],{},[65,4787,4788,4790,4792,4794],{},[68,4789,70],{},[68,4791,73],{},[68,4793,76],{},[68,4795,79],{},[81,4797,4798,4808,4818],{},[65,4799,4800,4802,4804,4806],{},[86,4801,301],{},[86,4803,304],{},[86,4805,307],{},[86,4807,97],{},[65,4809,4810,4812,4814,4816],{},[86,4811,314],{},[86,4813,317],{},[86,4815,320],{},[86,4817,97],{},[65,4819,4820,4822,4824,4826],{},[86,4821,327],{},[86,4823,330],{},[86,4825,121],{},[86,4827,149],{},[54,4829,338],{"id":337},[59,4831,4832,4844],{},[62,4833,4834],{},[65,4835,4836,4838,4840,4842],{},[68,4837,70],{},[68,4839,73],{},[68,4841,76],{},[68,4843,79],{},[81,4845,4846,4856,4866,4876],{},[65,4847,4848,4850,4852,4854],{},[86,4849,359],{},[86,4851,362],{},[86,4853,365],{},[86,4855,97],{},[65,4857,4858,4860,4862,4864],{},[86,4859,372],{},[86,4861,375],{},[86,4863,378],{},[86,4865,97],{},[65,4867,4868,4870,4872,4874],{},[86,4869,385],{},[86,4871,388],{},[86,4873,391],{},[86,4875,97],{},[65,4877,4878,4880,4882,4884],{},[86,4879,398],{},[86,4881,401],{},[86,4883,404],{},[86,4885,97],{},[54,4887,410],{"id":409},[59,4889,4890,4902],{},[62,4891,4892],{},[65,4893,4894,4896,4898,4900],{},[68,4895,70],{},[68,4897,73],{},[68,4899,76],{},[68,4901,79],{},[81,4903,4904,4914],{},[65,4905,4906,4908,4910,4912],{},[86,4907,431],{},[86,4909,434],{},[86,4911,437],{},[86,4913,97],{},[65,4915,4916,4918,4920,4922],{},[86,4917,444],{},[86,4919,447],{},[86,4921,121],{},[86,4923,149],{},[54,4925,455],{"id":454},[59,4927,4928,4940],{},[62,4929,4930],{},[65,4931,4932,4934,4936,4938],{},[68,4933,70],{},[68,4935,73],{},[68,4937,76],{},[68,4939,79],{},[81,4941,4942,4952,4962,4972],{},[65,4943,4944,4946,4948,4950],{},[86,4945,476],{},[86,4947,479],{},[86,4949,482],{},[86,4951,97],{},[65,4953,4954,4956,4958,4960],{},[86,4955,489],{},[86,4957,492],{},[86,4959,495],{},[86,4961,97],{},[65,4963,4964,4966,4968,4970],{},[86,4965,502],{},[86,4967,505],{},[86,4969,508],{},[86,4971,97],{},[65,4973,4974,4976,4978,4980],{},[86,4975,515],{},[86,4977,518],{},[86,4979,121],{},[86,4981,149],{},[54,4983,526],{"id":525},[59,4985,4986,4998],{},[62,4987,4988],{},[65,4989,4990,4992,4994,4996],{},[68,4991,70],{},[68,4993,73],{},[68,4995,76],{},[68,4997,79],{},[81,4999,5000],{},[65,5001,5002,5004,5006,5008],{},[86,5003,547],{},[86,5005,550],{},[86,5007,121],{},[86,5009,97],{},[54,5011,558],{"id":557},[59,5013,5014,5026],{},[62,5015,5016],{},[65,5017,5018,5020,5022,5024],{},[68,5019,70],{},[68,5021,73],{},[68,5023,76],{},[68,5025,79],{},[81,5027,5028,5038],{},[65,5029,5030,5032,5034,5036],{},[86,5031,579],{},[86,5033,582],{},[86,5035,585],{},[86,5037,97],{},[65,5039,5040,5042,5044,5046],{},[86,5041,592],{},[86,5043,595],{},[86,5045,121],{},[86,5047,97],{},[54,5049,603],{"id":602},[59,5051,5052,5064],{},[62,5053,5054],{},[65,5055,5056,5058,5060,5062],{},[68,5057,70],{},[68,5059,73],{},[68,5061,76],{},[68,5063,79],{},[81,5065,5066,5076,5086,5096,5106,5116,5126],{},[65,5067,5068,5070,5072,5074],{},[86,5069,624],{},[86,5071,627],{},[86,5073,121],{},[86,5075,149],{},[65,5077,5078,5080,5082,5084],{},[86,5079,636],{},[86,5081,639],{},[86,5083,642],{},[86,5085,97],{},[65,5087,5088,5090,5092,5094],{},[86,5089,649],{},[86,5091,652],{},[86,5093,655],{},[86,5095,97],{},[65,5097,5098,5100,5102,5104],{},[86,5099,662],{},[86,5101,665],{},[86,5103,121],{},[86,5105,149],{},[65,5107,5108,5110,5112,5114],{},[86,5109,674],{},[86,5111,677],{},[86,5113,680],{},[86,5115,149],{},[65,5117,5118,5120,5122,5124],{},[86,5119,687],{},[86,5121,690],{},[86,5123,121],{},[86,5125,175],{},[65,5127,5128,5130,5132,5134],{},[86,5129,699],{},[86,5131,702],{},[86,5133,121],{},[86,5135,149],{},[31,5137,710],{"id":709},[10,5139,713],{},[10,5141,5142,719],{},[20,5143,718],{},[10,5145,5146,725],{},[20,5147,724],{},[10,5149,5150,731],{},[20,5151,730],{},[10,5153,5154,737],{},[20,5155,736],{},[31,5157,741],{"id":740},[10,5159,744],{},[746,5161,5162,5164,5166,5168,5170,5172,5174],{},[749,5163,751],{},[749,5165,754],{},[749,5167,757],{},[749,5169,760],{},[749,5171,763],{},[749,5173,766],{},[749,5175,769],{},[31,5177,773],{"id":772},[10,5179,776],{},[10,5181,779],{},{"title":781,"searchDepth":782,"depth":782,"links":5183},[5184,5194,5195,5196],{"id":33,"depth":782,"text":34,"children":5185},[5186,5187,5188,5189,5190,5191,5192,5193],{"id":56,"depth":787,"text":57},{"id":279,"depth":787,"text":280},{"id":337,"depth":787,"text":338},{"id":409,"depth":787,"text":410},{"id":454,"depth":787,"text":455},{"id":525,"depth":787,"text":526},{"id":557,"depth":787,"text":558},{"id":602,"depth":787,"text":603},{"id":709,"depth":782,"text":710},{"id":740,"depth":782,"text":741},{"id":772,"depth":782,"text":773},{},{"title":5,"description":799},[813,814,815,816,817,818],{"id":5201,"title":5202,"body":5203,"category":3985,"description":5369,"extension":800,"guideId":5370,"locale":802,"meta":5371,"navigation":804,"order":5372,"path":5373,"publishedAt":5374,"readTime":808,"seo":5375,"slug":5376,"stem":5377,"tags":5378,"updatedAt":5374,"__hash__":5385},"help\u002Fhelp\u002Ffloorplan-import-calibration.nl.md","Grondplan importeren en kalibreren",{"type":7,"value":5204,"toc":5363},[5205,5212,5217,5221,5232,5252,5255,5260,5264,5290,5293,5319,5322,5326,5329,5332,5346,5349,5353,5356],[10,5206,5207,5208,5211],{},"Een geïmporteerd plan is in PlanElec een ",[20,5209,5210],{},"referentielaag",". Muren, ruimtes en elektrische symbolen tekent u daarboven als bewerkbare PlanElec-gegevens. Daardoor blijft de export leesbaar wanneer u het oorspronkelijke plan later verbergt of vervangt.",[10,5213,5214],{},[3747,5215],{"id":5216},"import",[31,5218,5220],{"id":5219},"een-planreferentie-importeren","Een planreferentie importeren",[10,5222,5223,5224,5227,5228,5231],{},"Open in ",[20,5225,5226],{},"Grondplan"," de ",[20,5229,5230],{},"Galerij"," en kies importeren. U kunt PNG-, JPEG- en WebP-afbeeldingen, afzonderlijke PDF-pagina's en DXF-tekeningen selecteren en aan een verdieping koppelen.",[3817,5233,5234,5237,5240,5243],{},[749,5235,5236],{},"Kies het bestand en de doelverdieping.",[749,5238,5239],{},"Kies bij een PDF de benodigde pagina's; bij een DXF kunt u overbodige tekenlagen uitschakelen.",[749,5241,5242],{},"Rond de import af. Een bestand met een fout kunt u opnieuw proberen.",[749,5244,5245,5246,5249,5250,3806],{},"Kies ",[20,5247,5248],{},"Instellen"," voor een afzonderlijke laag. Na één import opent de lagenwerkbank meteen; na een batch opent u die zelf via ",[20,5251,5248],{},[10,5253,5254],{},"DXF wordt in de browser als referentiebeeld verwerkt. Model Space en de gekozen lagen tellen mee; DWG-bestanden worden niet geïmporteerd. Controleer dus of de uitsnede werkelijk het gewenste grondplan bevat.",[10,5256,5257],{},[3747,5258],{"id":5259},"calibrate",[31,5261,5263],{"id":5262},"schaal-rotatie-en-positie-instellen","Schaal, rotatie en positie instellen",[10,5265,5266,5267,5270,5271,5270,5274,5277,5278,5281,5282,5285,5286,5289],{},"De lagenwerkbank heeft de stappen ",[20,5268,5269],{},"Bijsnijden",", ",[20,5272,5273],{},"Draaien",[20,5275,5276],{},"Schaal"," en ",[20,5279,5280],{},"Positie",". Tijdens het instellen blijven pannen en zoomen beschikbaar, maar tekengereedschappen zijn vergrendeld. Uw wijzigingen zijn een concept tot u ",[20,5283,5284],{},"Gereed"," kiest; ",[20,5287,5288],{},"Annuleren"," verwerpt ze.",[10,5291,5292],{},"Kalibreer een afbeeldings- of PDF-laag met een bekende maat:",[3817,5294,5295,5305,5308,5311,5314],{},[749,5296,5297,5298,5300,5301,5304],{},"Open ",[20,5299,5276],{}," of kies ",[20,5302,5303],{},"Kalibreren"," in de werkbalk.",[749,5306,5307],{},"Zet twee punten op een afstand waarvan u de werkelijke lengte kent.",[749,5309,5310],{},"Voer de lengte in meter in en controleer de preview.",[749,5312,5313],{},"Richt de referentielijn indien nodig horizontaal of verticaal uit.",[749,5315,5316,5317,3806],{},"Bevestig pas na controle met ",[20,5318,5284],{},[10,5320,5321],{},"Bij een DXF neemt PlanElec de schaal eerst uit de tekeneenheid over of toont het een schatting om te kiezen. De bron van de schaal blijft zichtbaar. Kalibreer handmatig na wanneer een bekende maat niet klopt.",[31,5323,5325],{"id":5324},"op-de-referentie-verder-tekenen","Op de referentie verder tekenen",[10,5327,5328],{},"Pas zo nodig dekking en uitsnede aan. Teken vervolgens gesloten buiten- en binnenmuren als polygoon of rechthoek. PlanElec herkent daaruit ruimtes; toestellen en kabelroutes baseren zich op deze bewerkbare muurstructuur, niet op pixels van de referentie.",[10,5330,5331],{},"Controleer vóór u verder plant:",[746,5333,5334,5337,5340,5343],{},[749,5335,5336],{},"Kloppen een of meer bekende maten met de ingestelde schaal?",[749,5338,5339],{},"Staat het plan goed gedraaid en op de juiste plaats?",[749,5341,5342],{},"Zijn alleen relevante lagen zichtbaar?",[749,5344,5345],{},"Zijn buiten- en binnenmuren als PlanElec-muren overgetekend?",[10,5347,5348],{},"Bij meerdere verdiepingen stelt u elke verdieping afzonderlijk in. Uitlijning tussen verdiepingen is een aparte stap en vervangt de kalibratie van een geïmporteerde laag niet.",[31,5350,5352],{"id":5351},"wat-importeren-niet-doet","Wat importeren niet doet",[10,5354,5355],{},"De import herkent geen ruimtes of elektrische installatie automatisch en maakt geen officiële opmeting. Het is een nauwkeurig tekenhulpmiddel. Controleer maten, muurverloop en de werkelijke uitvoering vóór u symbolen plaatst of documenten exporteert.",[10,5357,5358,5359,3806],{},"Volgende stap: ",[3747,5360,5362],{"href":5361},"\u002Fhelp\u002Felektrische-symbolen-plaatsen-en-verbinden","elektrische symbolen plaatsen en met de topologie verbinden",{"title":781,"searchDepth":782,"depth":782,"links":5364},[5365,5366,5367,5368],{"id":5219,"depth":782,"text":5220},{"id":5262,"depth":782,"text":5263},{"id":5324,"depth":782,"text":5325},{"id":5351,"depth":782,"text":5352},"Gebruik een afbeelding, PDF of DXF als schaalvaste referentie, richt de laag uit en teken er het bewerkbare grondplan op.","floorplan-import-calibration",{},5,"\u002Fhelp\u002Ffloorplan-import-calibration.nl","2026-08-21",{"title":5202,"description":5369},"grondplan-importeren-en-kalibreren","help\u002Ffloorplan-import-calibration.nl",[5379,5380,5381,5382,5383,5384],"grondplan importeren","PDF","DXF","kalibreren","schaal","lagenwerkbank","GyLdedrWi1NV2O0_zDOEK7JKL7-pusEHFnJtj2PtB8s",{"id":5387,"title":5388,"body":5389,"category":3985,"description":5531,"extension":800,"guideId":5532,"locale":802,"meta":5533,"navigation":804,"order":5534,"path":5535,"publishedAt":5374,"readTime":3992,"seo":5536,"slug":5537,"stem":5538,"tags":5539,"updatedAt":5374,"__hash__":5546},"help\u002Fhelp\u002Fplace-and-connect-symbols.nl.md","Elektrische symbolen plaatsen en verbinden",{"type":7,"value":5390,"toc":5525},[5391,5398,5403,5407,5412,5426,5429,5433,5443,5453,5456,5461,5465,5468,5471,5474,5498,5501,5505,5519],[10,5392,5393,5394,5397],{},"Een symbool in het grondplan beschrijft eerst zijn ",[20,5395,5396],{},"fysieke plaats",". Pas de koppeling met de elektrische topologie maakt er een toegewezen verbruiker of toestel van voor stroomkring, schema en documenten.",[10,5399,5400],{},[3747,5401],{"id":5402},"place",[31,5404,5406],{"id":5405},"symbolen-uit-het-palet-plaatsen","Symbolen uit het palet plaatsen",[10,5408,5223,5409,5411],{},[20,5410,5226],{}," het gereedschapspalet en kies bijvoorbeeld een stopcontact, schakelaar, lichtpunt, vast toestel, doos of verdeelkast. De gereedschapsiconen staan in het palet; bij aanwijzen toont de toepassing de naam.",[3817,5413,5414,5417,5420,5423],{},[749,5415,5416],{},"Kies het gereedschap voor het symbool.",[749,5418,5419],{},"Plaats wandgebonden toestellen aan de juiste kant van de muur. Stopcontacten en schakelaars klikken op de muur vast.",[749,5421,5422],{},"Plaats vrije lichtpunten of spots in de ruimte.",[749,5424,5425],{},"Controleer na het plaatsen positie, oriëntatie en symboolvariant.",[10,5427,5428],{},"Een symbool kan alleen worden geplaatst waar de editor een geldige positie herkent. De preview toont vóór het bevestigen de echte geometrie. Corrigeer eerst muur of ruimte wanneer het symbool niet op de beoogde plaats vastklikt.",[31,5430,5432],{"id":5431},"gemeenschappelijke-afdekramen-maken","Gemeenschappelijke afdekramen maken",[10,5434,5435,5436,5439,5440,5442],{},"Een installatiegroep is een fysieke combinatie met een gemeenschappelijk twee- tot vijfvoudig afdekraam. Zij is ",[20,5437,5438],{},"geen"," schakelketen en ",[20,5441,5438],{}," stroomkring.",[10,5444,5445,5446,5449,5450,5452],{},"Sleep geschikte toestellen aan dezelfde muurzijde bij elkaar of start het raamgereedschap. In het paneel ",[20,5447,5448],{},"Installatiegroep"," kiest u horizontaal of verticaal en sluit u af met ",[20,5451,5284],{},". Verplaatst u één lid, dan verplaatst de combinatie mee.",[10,5454,5455],{},"Schakelaars, standaardstopcontacten, Ethernet- en coax-aansluitingen kunnen worden gegroepeerd. IP44-stopcontacten blijven vanwege hun afdichtende raam uitgesloten. Passieve data-aansluitingen worden hierdoor geen 230-V-verbruikers.",[10,5457,5458],{},[3747,5459],{"id":5460},"topology",[31,5462,5464],{"id":5463},"met-de-elektrische-topologie-verbinden","Met de elektrische topologie verbinden",[10,5466,5467],{},"Open de eigenschappen van het geplaatste toestel en koppel het aan een typecompatibele knoop in de elektrische topologie. Varianten van stopcontacten, schakelaars en lichtpunten worden als passende families behandeld. Verbindings- en aftakdozen zijn alleen elektrisch werkzaam wanneer ze werkelijk gekoppeld zijn.",[10,5469,5470],{},"Controleer daarna de lijst met niet-verbonden onderdelen. Daarin staan symbolen die wel in het grondplan liggen, maar nog niet bij het elektrische model horen.",[10,5472,5473],{},"Houd dit onderscheid aan:",[746,5475,5476,5481,5486,5492],{},[749,5477,5478,5480],{},[20,5479,5280],{},": waar bevindt het toestel zich?",[749,5482,5483,5485],{},[20,5484,5448],{},": welke inzetten delen een afdekraam?",[749,5487,5488,5491],{},[20,5489,5490],{},"Topologie",": welke elektrische knoop hoort bij het toestel?",[749,5493,5494,5497],{},[20,5495,5496],{},"Stroomkring",": via welk beveiligingstoestel wordt die knoop gevoed?",[10,5499,5500],{},"Een verandering aan het afdekraam verandert geen schakelfunctie of stroomkring. Voor de bediening van verlichting bewerkt u daarna de schakelketen; voor de voeding wijst u toestellen aan een stroomkring toe.",[31,5502,5504],{"id":5503},"controle-vóór-de-volgende-stap","Controle vóór de volgende stap",[746,5506,5507,5510,5513,5516],{},[749,5508,5509],{},"Elk symbool staat op de werkelijk bedoelde plaats.",[749,5511,5512],{},"Wandgebonden toestellen zijn aan de juiste muurzijde uitgelijnd.",[749,5514,5515],{},"Raamcombinaties volgen de geplande montage, niet een veronderstelde bedrading.",[749,5517,5518],{},"Alle elektrische toestellen zijn met de passende topologieknoop gekoppeld.",[10,5520,5358,5521,3806],{},[3747,5522,5524],{"href":5523},"\u002Fhelp\u002Fschakelketens-stroomkringen-en-kabelroutes","schakelketens, stroomkringen en kabelroutes bewerken",{"title":781,"searchDepth":782,"depth":782,"links":5526},[5527,5528,5529,5530],{"id":5405,"depth":782,"text":5406},{"id":5431,"depth":782,"text":5432},{"id":5463,"depth":782,"text":5464},{"id":5503,"depth":782,"text":5504},"Plaats toestellen op de juiste positie, vorm gemeenschappelijke afdekramen en verbind elektrische symbolen met de passende topologie.","place-and-connect-symbols",{},6,"\u002Fhelp\u002Fplace-and-connect-symbols.nl",{"title":5388,"description":5531},"elektrische-symbolen-plaatsen-en-verbinden","help\u002Fplace-and-connect-symbols.nl",[5540,5541,5542,5543,5544,5545],"elektrische symbolen","stopcontacten","schakelaars","verlichting","afdekramen","topologie","Nn5qNlCBUOQPo7aQ1I-pN7iR7m9qQOsocrx8VDKYCEs",{"id":5548,"title":5549,"body":5550,"category":4252,"description":5667,"extension":800,"guideId":5668,"locale":802,"meta":5669,"navigation":804,"order":5670,"path":5671,"publishedAt":5374,"readTime":4256,"seo":5672,"slug":5673,"stem":5674,"tags":5675,"updatedAt":5374,"__hash__":5680},"help\u002Fhelp\u002Fswitch-chains-circuits-cable-routes.nl.md","Schakelketens, stroomkringen en kabelroutes bewerken",{"type":7,"value":5551,"toc":5661},[5552,5566,5571,5575,5582,5585,5588,5592,5596,5605,5608,5611,5616,5620,5634,5637,5640,5644,5658],[10,5553,5554,5555,5558,5559,5558,5562,5565],{},"Deze drie gereedschappen beantwoorden andere vragen: ",[20,5556,5557],{},"welke schakelaar bedient welk lichtpunt?"," ",[20,5560,5561],{},"Welke stroomkring voedt welk toestel?",[20,5563,5564],{},"Waar loopt de kabel ruimtelijk?"," Bewerk ze na elkaar zodat het plan technisch traceerbaar blijft.",[10,5567,5568],{},[3747,5569],{"id":5570},"switch-chains",[31,5572,5574],{"id":5573},"schakelaars-en-lichtpunten-als-keten-verbinden","Schakelaars en lichtpunten als keten verbinden",[10,5576,5577,5578,5581],{},"Kies in het grondplan ",[20,5579,5580],{},"Schakelketen",". Dit gereedschap verbindt schakelaars en de lichtpunten die zij bedienen in een logische volgorde. Voor vrije schakelaars en lichtpunten in een ruimte kan PlanElec een voorstel maken; controleer het altijd tegen de bedoelde bediening.",[10,5583,5584],{},"Bij een manuele keten kiest u de betrokken toestellen bewust. Een geldige keten bevat minstens één schakelaar en één lichtpunt. Een toestel kan niet tegelijk in meerdere schakelketens zitten. Over verschillende verdiepingen blijft de keten projectbreed verbonden; per verdieping ziet u alleen de lokale delen en vervolgmarkeringen.",[10,5586,5587],{},"Schakelfunctie en poolaantal zijn verschillende instellingen. De toepassing kan een enkelpolige, wissel- of kruisschakeling uit de keten afleiden; het poolaantal kiest u uitdrukkelijk. Een serieschakelaar is één fysiek toestel met twee aparte kanalen: wijs elk lichtpunt bewust aan kanaal A of B toe.",[10,5589,5590],{},[3747,5591],{"id":4105},[31,5593,5595],{"id":5594},"toestellen-aan-een-bestaande-stroomkring-toewijzen","Toestellen aan een bestaande stroomkring toewijzen",[10,5597,5245,5598,5601,5602,5604],{},[20,5599,5600],{},"Stroomkring toewijzen",". Selecteer in het paneel eerst de doelstroomkring of automaat en daarna de toestellen, eventueel via de verdiepingskeuze. Met ",[20,5603,5284],{}," neemt PlanElec de selectie samen over.",[10,5606,5607],{},"Nog niet gekoppelde toestellen worden daarbij als verbruikers onder de gekozen automaat aangemaakt en met hun grondsymbool verbonden. Voor een toestel dat al aan een andere automaat hangt, vraagt de toepassing eerst een uitdrukkelijke bevestiging. Annuleren wijzigt geen projectdata; u kunt de volledige bevestiging in één stap ongedaan maken.",[10,5609,5610],{},"De stroomkringtoewijzing beschrijft de elektrische verbondenheid. Zij bepaalt nog geen werkelijk traject door muren, schachten of verdiepingen.",[10,5612,5613],{},[3747,5614],{"id":5615},"cable-routes",[31,5617,5619],{"id":5618},"kabelroute-plannen-en-bijwerken","Kabelroute plannen en bijwerken",[10,5621,5245,5622,5625,5626,5629,5630,5633],{},[20,5623,5624],{},"Kabelroute",". Als kabels in de topologie bestaan, kunt u voor de actieve verdieping ",[20,5627,5628],{},"Alles automatisch routeren"," gebruiken of, na selectie van één kabel, ",[20,5631,5632],{},"Automatisch routeren",". De automatische route volgt zo veel mogelijk de getekende muren; toets die aan de beoogde uitvoering.",[10,5635,5636],{},"Selecteer een kabellijn om manueel te bewerken. Klik op een segment om een routepunt toe te voegen en meteen te verslepen; dubbelklik om een routepunt te verwijderen. Escape heft de selectie op of verlaat de modus. De getoonde lengte wordt gebruikt in materiaallijsten, spanningsvalberekening en exporten, dus controleer elk uitzonderlijk traject.",[10,5638,5639],{},"Voor een kabel tussen verdiepingen kiest u in het kabelroutepaneel uitdrukkelijk een bestaande trap, schacht of stijgweg. PlanElec verzint geen verticale verbinding. Ontbreekt een nodige verbinding of betrouwbare hoogte, dan blijft de route onvolledig in plaats van een schijnlengte te tonen.",[31,5641,5643],{"id":5642},"eindcontrole","Eindcontrole",[746,5645,5646,5649,5652,5655],{},[749,5647,5648],{},"Controleer de schakelketen op de gewenste bediening, niet alleen op nabijheid.",[749,5650,5651],{},"Controleer stroomkring, beveiliging en topologie van elk toestel.",[749,5653,5654],{},"Controleer kabelroute en lengte aan de geplande installatieweg.",[749,5656,5657],{},"Behandel automatische voorstellen als bewerkbare planhulp, niet als uitvoeringsvrijgave.",[10,5659,5660],{},"Daarna kunt u verdeelkast en eendraadschema verder controleren en de ondersteunde zelfcontrole uitvoeren.",{"title":781,"searchDepth":782,"depth":782,"links":5662},[5663,5664,5665,5666],{"id":5573,"depth":782,"text":5574},{"id":5594,"depth":782,"text":5595},{"id":5618,"depth":782,"text":5619},{"id":5642,"depth":782,"text":5643},"Houd lichtbediening, stroomkringtoewijzing en het fysieke kabeltraject apart en gebruik voor elke stap het juiste gereedschap.","switch-chains-circuits-cable-routes",{},7,"\u002Fhelp\u002Fswitch-chains-circuits-cable-routes.nl",{"title":5549,"description":5667},"schakelketens-stroomkringen-en-kabelroutes","help\u002Fswitch-chains-circuits-cable-routes.nl",[5676,5677,4263,5678,4262,5679],"schakelketen","wisselschakeling","automaat","kabellengte","y2npmArx1kUa99KSZHmFwkSOO1M3Kzsit2DwSTPUUGg",1787555185102]